Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “readout systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Operations manual: On Site Monitor (OSM), solar heating and cooling systems

The on-site monitor is a portable device which, when connected to a solar system site data acquisition subsystem; allows readouts of clock and sensor data in voltage or engineering units at instrumented solar heating and cooling sites. The unit is described and procedures for its proper operation are presented.

Source record↗

Wavelength error analysis in a multiple-beam Fizeau laser wavemeter having a linear diode array readout

An estimate of the wavelength accuracy of a laser wavemeter is performed for a system consisting of a multiple-beam Fizeau interferometer and a linear photosensor array readout. The analysis consists of determining the fringe position errors which result when various noise sources are included in the fringe forming and detection process. Two methods of estimating the fringe centers are considered: (1) maximum pixel current location, and (2) average pixel location for two detectors with nearly equal output currents. Wavelength error results for these two methods are compared for some typical wavemeter parameters.

Robinson, D. M.↗

A Temperature Sensor using a Silicon-on-Insulator (SOI) Timer for Very Wide Temperature Measurement

A temperature sensor based on a commercial-off-the-shelf (COTS) Silicon-on-Insulator (SOI) Timer was designed for extreme temperature applications. The sensor can operate under a wide temperature range from hot jet engine compartments to cryogenic space exploration missions. For example, in Jet Engine Distributed Control Architecture, the sensor must be able to operate at temperatures exceeding 150 C. For space missions, extremely low cryogenic temperatures need to be measured. The output of the sensor, which consisted of a stream of digitized pulses whose period was proportional to the sensed temperature, can be interfaced with a controller or a computer. The data acquisition system would then give a direct readout of the temperature through the use of a look-up table, a built-in algorithm, or a mathematical model. Because of the wide range of temperature measurement and because the sensor is made of carefully selected COTS parts, this work is directly applicable to the NASA Fundamental Aeronautics/Subsonic Fixed Wing Program--Jet Engine Distributed Engine Control Task and to the NASA Electronic Parts and Packaging (NEPP) Program. In the past, a temperature sensor was designed and built using an SOI operational amplifier, and a report was issued. This work used an SOI 555 timer as its core and is completely new work.

Patterson, Richard L.↗

PICO - the Probe of Inflation and Cosmic Origins

The Probe of Inflation and Cosmic Origins (PICO) is a NASA-funded study of a Probe-class mission concept. The top-level science objectives are to probe the physics of the Big Bang by measuring or constraining the energy scale of inflation, probe fundamental physics by measuring the number of light particles in the Universe and the sum of neutrino masses, to measure the reionization history of the Universe, and to understand the mechanisms driving the cosmic star formation history, and the physics of the galactic magnetic field. PICO would have multiple frequency bands between 21 and 799 GHz, and would survey the entire sky, producing maps of the polarization of the cosmic microwave background radiation, of galactic dust, of synchrotron radiation, and of various populations of point sources. Several instrument configurations, optical systems, cooling architectures, and detector and readout technologies have been and continue to be considered in the development of the mission concept. We will present a snapshot of the baseline mission concept currently under development.

Bonato, Matteo↗

Heterodyne readout for read-write holographic memories

A heterodyne readout technique for read-write holographic memory systems that reconstruct a virtual image wavefront is described and demonstrated. The conventionally recorded hologram is illuminated simultaneously with a suitable combination of temporally modulated reference and modified object waves for readout. Best performance is obtained for temporal phase modulation. The coupling of the illuminating wavefronts by the hologram is analyzed.

Mezrich, R. S.↗

The continuous readout stream of the MicroBooNE liquid argon time projection chamber for detection of supernova burst neutrinos

The MicroBooNE continuous readout stream is a parallel readout of the MicroBooNE liquid argon time projection chamber (LArTPC) which enables detection of non-beam events such as those from a supernova neutrino burst. The low energies of the supernova neutrinos and the intense cosmic-ray background flux due to the near-surface detector location makes triggering on these events very challenging. Instead, MicroBooNE relies on a delayed trigger generated by SNEWS (the Supernova Early Warning System) for detecting supernova neutrinos. The continuous readout of the LArTPC generates large data volumes, and requires the use of real-time compression algorithms (zero suppression and Huffman compression) implemented in an FPGA (field-programmable gate array) in the readout electronics. In this paper we present the results of the optimization of the data reduction algorithms, and their operational performance. To demonstrate the capability of the continuous stream to detect low-energy electrons, a sample of Michel electrons from stopping cosmic-ray muons is reconstructed and compared to a similar sample from the lossless triggered readout stream.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Machine Learning on Heterogeneous, Edge, and Quantum Hardware for Particle Physics (ML-HEQUPP)

The next generation of particle physics experiments will face a new era of challenges in data acquisition, due to unprecedented data rates and volumes along with extreme environments and operational constraints. Harnessing this data for scientific discovery demands real-time inference and decision-making, intelligent data reduction, and efficient processing architectures beyond current capabilities. Crucial to the success of this experimental paradigm are several emerging technologies, such as artificial intelligence and machine learning (AI/ML) and silicon microelectronics, and the advent of quantum algorithms and processing. Their intersection includes areas of research such as low-power and low-latency devices for edge computing, heterogeneous accelerator systems, reconfigurable hardware, novel codesign and synthesis strategies, readout for cryogenic or high-radiation environments, and analog computing. This white paper presents a community-driven vision to identify and prioritize research and development opportunities in hardware-based ML systems and corresponding physics applications, contributing towards a successful transition to the new data frontier of fundamental science.

Gonski, Julia [SLAC]↗

Real-Time Monitoring of Gas-Phase and Dissolved CO 2 Using a Mixed-Matrix Composite Integrated Fiber Optic Sensor for Carbon Storage Application

Novel chemical sensors that improve detection and quantification of CO 2 are critical to ensuring safe and cost-effective monitoring of carbon storage sites. Fiber optic (FO) based chemical sensor systems are promising field-deployable systems for real-time monitoring of CO 2 in geological formations for long-range distributed sensing. Here, a mixed-matrix composite integrated FO sensor system was developed with a purely optical readout that reliably operates as a detector for gas-phase and dissolved CO 2 . A mixed-matrix composite sensor coating consisting of plasmonic nanocrystals and hydrophobic zeolite embedded in a polymer matrix was integrated on the FO sensor. The mixed-matrix composite FO sensor showed excellent reversibility/stability in a high humidity environment and sensitivity to gas-phase CO 2 over a large concentration range. This remarkable sensing performance was enabled by using plasmonic nanocrystals to significantly enhance the sensitivity and a hydrophobic zeolite to effectively mitigate interference from water vapor. The sensor exhibited the ability to sense CO 2 in the presence of other geologically relevant gases, which is of importance for applications in geological formations. A prototype FO sensor configuration which possesses a robust sensing capability for monitoring dissolved CO 2 in natural water was demonstrated. Reproducibility was confirmed over many cycles, both in a laboratory setting and in the field. More importantly, we demonstrated on-line monitoring capabilities with a wireless telemetry system, which transferred the data from the field to a website. The combination of outstanding CO 2 sensing properties and facile coating processability makes this mixed-matrix composite FO sensor a good candidate suitable for practical carbon storage applications.

54 ENVIRONMENTAL SCIENCES↗

Harnessing Heterologous Bacterial Two-Component Systems as Biosensors to Address Challenges in Fermentation Scale-Up

Scaling up bacterial fermentation from bench to industrial scale often results in unpredictable performance losses, possibly in part due to changes in microenvironmental conditions such as pH. To investigate this, we developed a suite of pH-sensitive biosensors from bacterial two-component systems (TCSs) that provide a dynamic, fluorescent readout in response to extracellular pH changes. TCSs consist of a periplasmic sensor histidine kinase (HK) that, in response to an extracellular stimulus, autophosphorylates intracellularly and subsequently transfers the phosphate to a cognate response regulator (RR) that modulates transcription of target genes. We utilized three pH-responsive TCSs (referred to here as CVJ1, CVJ30, and CVJ79) and linked their output to GFP. This was achieved by placing the RR promoter upstream of GFP or by constructing a chimeric RR composed of the native receiver domain and the DNA-binding domain of another well-characterized RR with a defined promoter. All components - HK, RR (native or chimeric), and GFP under its corresponding promoter - were cloned into a broad-host-range plasmid. Sensors were validated in Escherichia coli and Pseudomonas putida, including the muconic acid-producing strain P. putida TL207. All three biosensors successfully reported pH, with fluorescence (normalized to optical density) correlating strongly with media pH. Among the native sensors, CVJ79 showed the most robust performance while CVJ1 also performed best in its native form; CVJ30 exhibited improved functionality as a chimera, suggesting that modular RR design can enhance compatibility in some heterologous hosts. Further, CVJ79 was activated by alkaline conditions, while CVJ30 responded to acidic environments. Notably, CVJ1 was induced by high pH in wild-type E. coli and P. putida, but low pH in TL207. The observed differences in sensor activation between strains - particularly the divergent response of CVJ1 - suggest that host-specific regulatory pathways may influence how cells perceive and adapt to pH stress. Moving forward, these biosensors can be used to guide the rational design of more robust strains, optimize process conditions in real time, and inform strategies to minimize physiological heterogeneity during scale-up. Integrating these tools into high-throughput screening and bioreactors will be a key step toward improving predictability and performance in industrial bioprocesses.

09 BIOMASS FUELS↗

First results from a high-frame-rate, multi-GHz ionizing particle detection system geared toward accelerator diagnostic applications

An integrated detection system, consists of a thin diamond sensor incorporated into a compact signal loop, coupled in turn to an application-specific integrated circuit readout chip, has been tested for the first time, using ps-duration electron pulses from the Next Linear Collider Test Accelerator at the SLAC National Accelerator Laboratory. For readout frame rates as high as 120 kHz, the detection system is shown to achieve a linear dynamic range of 10 3 and a bandwidth of 4–5 GHz, with no ringing seen on the tail of the output pulse. These results represent the best-performing multi-GHz ionizing particle detection system achieved to date.

Ferezghi, Mohammadreza Mohseni [University of Cali↗

Anode sensitivity calibration of photomultiplier tubes used as a readout of the ELOSS detector

We present and discuss the methodology and results for an anode sensitivity calibration of Photomultiplier Tubes (PMTs) that serve as the optical readout of the Energy Loss Optical Scintillation System (ELOSS). The ELOSS detector, under development at the Facility for Rare Isotope Beams (FRIB), is a gaseous Xe scintillation-based detector designed to identify the atomic number (Z) of nuclear reaction fragments by energy-loss measurement. Variation in the anode sensitivity from tube to tube of commercially available PMTs limits ELOSS from reaching its ultimate Z resolution. A methodical approach to calibrating PMT anode sensitivities to a single target value by systematic PMT gain corrections is presented. Although the calibration process is discussed in terms of its impact on ELOSS performance, the presented method is applicable to any optical detector system composed of a large number of PMTs needing anode sensitivity calibration.

Instrumentation for heavy-ion accelerators↗

Three-Qubit Encoding in Ytterbium-171 Atoms for Simulating 1+1D Quantum Chromodynamics

Simulating nuclear matter described by quantum chromodynamics using quantum computers is notoriously inefficient because of the assortment of quark degrees of freedom such as matter/antimatter, flavor, color, and spin. Here, we propose to address this resource efficiency challenge by encoding three qubits within individual ytterbium-171 atoms of a neutral atom quantum processor. The three qubits are encoded in three distinct sectors: an electronic “clock” transition, the spin-1/2 nucleus, and the lowest two motional states in one radial direction of the harmonic trapping potential. We develop a family of composite sideband pulses and demonstrate a universal gate set and readout protocol for this three-qubit system. We then apply it to single-flavor quantum chromodynamics in 1+1D axial gauge for which the three qubits directly represent the occupancy of quarks in the three colors. We show that two atoms are sufficient to simulate both vacuum persistence oscillations and a screened hadron-number transition. We consider resource requirements and connections to error detection/correction. Our work is a step toward resource-efficient digital simulation of nuclear matter and opens new opportunities for versatile qubit encoding in neutral atom quantum processors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Magnets are Weber Bar Gravitational Wave Detectors

When a gravitational wave (GW) passes through a dc magnetic field, it couples to the conducting wires carrying the currents which generate the magnetic field, causing them to oscillate at the GW frequency. The oscillating currents then generate an ac component through which the GW can be detected-thus forming a resonant mass detector or a nagnetic Weber bar. We quantify this claim and demonstrate that magnets can have exceptional sensitivity to GWs over a frequency range demarcated by the mechanical and electromagnetic resonant frequencies of the system; indeed, we outline why a magnetic readout strategy can be considered an optimal Weber bar design. The concept is applicable to a broad class of magnets, but can be particularly well exploited by the powerful magnets being deployed in search of axion dark matter, for example, by DMRadio and ADMX-EFR. Explicitly, we demonstrate that the MRI magnet that is being deployed for ADMX-EFR can achieve a broadband GW strain sensitivity of ∼10^{-20}/sqrt[Hz] from a few kHz to about 10 MHz, with a peak sensitivity down to ∼10^{-22}/sqrt[Hz] at a kHz exploiting a mechanical resonance.

Domcke, Valerie↗

Experimental advances with the QICK (Quantum Instrumentation Control Kit) for superconducting quantum hardware

The Quantum Instrumentation Control Kit (QICK) is a standalone open-source qubit controller that was first introduced in 2022. In this follow-up work, we present recent upgrades to the QICK and the experimental use cases they uniquely enabled for superconducting qubit systems. These include multiplexed signal generation and readout, mixer-free readout, predistorted fast flux pulses, and phase-coherent pulses for parametric operations, including high-fidelity parametric entangling gates. We explain in detail how the QICK was used to enable these experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic Microcalorimeter (MMC) Gamma-Ray Detectors with Ultra-High Energy Resolution. Comprehensive Technology Readiness Assessment

Magnetic Microcalorimeter (MMC) gamma ray detectors have demonstrated very high energy resolution of 38 eV FWHM for gamma ray energies below 100 keV. This is an order or magnitude better than conventional HPGe detector and can remove most line-overlap problems in NDA by gamma spectroscopy below ~130 keV. Unlike superconducting transition edge sensors (TESs), MMCs have a reproducible and almost perfectly linear response, which greatly simplifies adding spectra from different detector pixels and reduces systematic errors in quantitative assays. The instrument is currently at TRL-5 but could advance to TRL-6 by improving the signal processing software and using the system for the quantitative analysis of a safeguards sample provided by e.g. the IAEA. Making MMC detectors commercially viable and used more widely then depends on making the technology more reliable, specifically by increasing the device uniformity and yield, and by developing commercial software. This situation is often only half-jokingly referred to as the “valley of death” and could be addressed though the SBIR program. Our collaborators at STAR Cryoelectronics LLC are well qualified to further advance MMC development, and XIA LLC is well-positioned to develop the data acquisition system and write the software for MMC readout. In addition, the advance to TRL-6 would be desirable to increase the visibility and showcase the value of MMC spectrometers, e.g. by placing one of them into the Safeguards Analytical Laboratory (SAL) at the IAEA, whose NDA experts have recently started to show interest in cryogenic detector technology. As a result of this LCP, we also now have an instrument at LLNL that we will use for various applications of MMCs in nuclear safeguards and science. We are confident that as the number of high-profile results increases, so will the interest in and commercial viability of this technology.

42 ENGINEERING↗

Magnetic Microcalorimeter (MMC) Gamma-Ray Detectors with Ultra-High Energy Resolution. Comprehensive Technology Readiness Assessment

Magnetic Microcalorimeter (MMC) gamma ray detectors have demonstrated very high energy resolution of 38 eV FWHM for gamma ray energies below 100 keV. This is an order or magnitude better than conventional HPGe detector and can remove most line-overlap problems in NDA by gamma spectroscopy below ~130 keV. Unlike superconducting transition edge sensors (TESs), MMCs have a reproducible and almost perfectly linear response, which greatly simplifies adding spectra from different detector pixels and reduces systematic errors in quantitative assays. The instrument is currently at TRL-5 but could advance to TRL-6 by improving the signal processing software and using the system for the quantitative analysis of a safeguards sample provided by e.g. the IAEA. Making MMC detectors commercially viable and used more widely then depends on making the technology more reliable, specifically by increasing the device uniformity and yield, and by developing commercial software. This situation is often only half-jokingly referred to as the “valley of death” and could be addressed though the SBIR program. Our collaborators at STAR Cryoelectronics LLC are well qualified to further advance MMC development, and XIA LLC is well-positioned to develop the data acquisition system and write the software for MMC readout. In addition, the advance to TRL-6 would be desirable to increase the visibility and showcase the value of MMC spectrometers, e.g. by placing one of them into the Safeguards Analytical Laboratory (SAL) at the IAEA, whose NDA experts have recently started to show interest in cryogenic detector technology. As a result of this LCP, we also now have an instrument at LLNL that we will use for various applications of MMCs in nuclear safeguards and science. We are confident that as the number of high-profile results increases, so will the interest in and commercial viability of this technology.

42 ENGINEERING↗

10 Boron-film-based gas detectors at ESS

The development of detectors for the European Spallation Source is an important parallel element to the effort put into the design and construction of the neutron source and instruments. The 10Boron-film-based detector developments that started over a decade ago as basic detector concepts have now reached technical maturity after intense prototyping work and numerous testing campaigns. Several of the ESS beamlines that will soon enter the commissioning phase started welcoming the detector systems built with the 10 B-film converter technology. The real-size demonstrators evolved in the last 2–3 years into a diverse suite of gas proportional counters for use in diffraction, reflectometry and small-angle scattering studies in spite of the operational complexity posed by the requirements for large-area coverage, low material budget and robustness for operation in the high-flux and high-radiation environment of ESS. The detectors are now being shipped to ESS or undergoing the last performance and calibration tests before being handed over to the instrument teams for installation in the host beamlines. A common feature of these detector systems is the very large number of readout channels that they are instrumented with in order to fulfill the demanding requirements for sensitivity, spatial resolution and count-rate capability. Across all of the detector types that will operate at ESS, the integration, testing and commissioning of the read-out technologies and software tools for data reduction, calibration and analysis are the focus of the detector and integration teams. These will yield a wealth of knowledge about their operation as well as initial results on the in-situ performance, a very important asset to ensure rapid commissioning of the detectors when neutrons from the ESS source become available. In this paper we will give an overview of the 10 B-film-based detector technologies included in the ESS detector suite that are currently facing the transition from the production phase to installation and integration with the other beamline components, which comes with its own specific challenges of both organizational and technical nature.

47 OTHER INSTRUMENTATION↗