Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radionuclide”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Cosmogenic Radionuclides in the Campo Del Cielo Iron Meteorite

Cosmogenic Be-10, Al-26, Cl-36, Ca-41, and Ni-59 were measured in the Campo del Cielo iron meteorite. Our results led us to conclude that the pre-atmospheric radius might have been approximately 2 m. Comparisons with other big bodies are also presented. Additional information is contained in the original extended abstract.

Liberman, R. G.↗

Hit rates and radiation doses to nuclei of bone lining cells from alpha-particle-emitting radionuclides

Factors relating the local concentration of a bone-seeking alpha-particle emitter to the mean hit rate have been determined for nuclei of bone lining cells using a Monte Carlo procedure. Cell nuclei were approximated by oblate spheroids with dimensions and location taken from a previous histomorphometric study. The Monte Carlo simulation is applicable for planar and diffuse labels at plane or cylindrical bone surfaces. Additionally, the mean nuclear dose per hit, the dose mean per hit, the mean track segment length and its second moment, the percentage of stoppers, and the frequency distribution of the dose have been determined. Some basic features of the hit statistics for bone lining cells have been outlined, and the consequences of existing standards of radiation protection with regard to the hit frequency to cell nuclei are discussed.

NASA Discipline Musculoskeletal↗

National Emission Standards for Hazardous Air Pollutants – Radionuclide Emissions Calendar Year 2022

This compliance report is required under 40 CFR 61, Subpart H. It will be submitted by NFO to regulators under NFO Manager signature. STIP needs to be coordinated with NFO review. Previous reports had Kathryn Gladden as the POC for this. While Kathryn should still be on the list of NFO reviewers, Cesar Alfaro (cesar.alfaro@nnsa.doe.gov, 5-4082) is now the NFO POC.

54 ENVIRONMENTAL SCIENCES↗

Systems for producing radionuclides using minimal target material

Among the various aspects of the present disclosure is the provision of systems for producing radioisotopes and improving the specific activity of radioisotopes (e.g., Cu-64 chloride). As described herein, the system includes a target material area or target material shape that matches the proton beam strike area or proton beam strike shape, resulting in optimal thickness with less target material required.

Gaehle, Gregory↗

A Comparison of Groundwater Sampling Technologies, Including Passive Diffusion Sampling, for Radionuclide Contamination - 20205

Using traditional high-flow purge methods for long-term water quality monitoring of deep groundwater wells can be expensive, affect contaminant migration, and produce excessive volumes of discharge water that can be difficult to manage. The use of low-flow pumping methods and depth discrete bailers (DDBs) can reduce the cost of sampling deep groundwater wells. In general, using different pumping methods to obtain reproducible and representative groundwater can be challenging. Passive diffusion samplers (PDSs) have successfully been used in long-term monitoring for volatile organic compounds, major ions, and trace-elements, but application has been limited for stable and radioactive isotopes. Beginning in 2018, the United States Geological Survey (USGS) conducted three sampling events to test the ability of PDSs and DDBs to obtain reproducible and representative groundwater samples. The sampled well is completed in a regional, permeable carbonate aquifer and is one in a set of wells that have historically been used for tritium tracer testing. All samples were obtained at 180 m (590 ft) below land surface (bls) in a 13.97 cm (5.5 inch) uncased well that has a total depth of 202 m (662 ft) bls. The first sampling event deployed a regenerated cellulose dialysis membrane (RCDM) PDS for 14 days with deionized water as the blank. The second sampling event deployed a RCDM for 27 days also with deionized water as the blank. The third sampling event deployed a Dual Membrane (DM) PDS for 65 days using a blank of tritium-dead carbonate water. The DM PDS was used to assess the effect of longer term deployment on tritium concentrations and address whether or not the PDSs reached equilibrium with ambient groundwater. The day after each of the three passive samplers were retrieved a DDB was used to obtain discrete non-integrated groundwater samples. For each DDB sampling day, the bailer was lowered into the well 10 consecutive times to determine if the water chemistry changed from the first to the last bailed sample. Quality assurance samples including blanks and duplicates were obtained during all three sampling events. All blank waters had tritium concentrations less than 21±33 pCi/L. Major ion (e.g. calcium, chloride, sodium, and sulfate) results were compared between all samples obtained with RCDM and DDB. Major ion concentrations showed a coefficient of variation of less than 6% between all RCDM and DDB samples; however, the coefficient of variation between the different deployment times and the two different methods for trace-element concentrations was much larger, particularly for manganese (82%), lead (41%), and zinc (33%). Stable isotope values were compared between the RCDM and DDB samples. The DDB sample results all fell within analytical uncertainty and were considered representative of the formation groundwater. The stable isotope values from the RCDM samples indicated that a longer deployment time was necessary to gain equilibrium and to obtain representative groundwater samples. Tritium results from groundwater samples obtained from the RCDM, DM, and DDB indicate that groundwaters obtained with PDSs produced tritium concentrations 2 to 3 times higher (between 1,426 and 3,060±87 pCi/L) than groundwaters obtained with a DDB (479 to 1,219±51 pCi/L). The longer the passive diffusion samplers were deployed, the higher the tritium concentration, suggesting that equilibrium with tritium was not reached within a 27-day deployment. DDB samples showed tritium results declining from the first to the last bailed sample for all three sampling events. This research suggests that tritium results from groundwater samples obtained from PDSs are more reproducible than samples obtained from DDBs. Also, PDSs likely do not accumulate isotopes of water but rather equilibrate with the ambient groundwater. On the other hand, both PDSs and DDBs were able to provide representative groundwater samples for major ions and have the potential to produce representative groundwater samples for stable isotopes of water (δD and δ{sup 18}O). Utilizing the most effective method for sampling groundwater is important for long-term groundwater monitoring. Quantifying the ability of passive diffusion groundwater samplers to obtain representative radioactive chemistry samples will help determine if these methods can be a useful alternative to pumping and purging wells for long-term monitoring. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Methods for producing radionuclides using minimal targeting material

Among the various aspects of the present disclosure is the provision of methods for producing radioisotopes and improving the specific activity of radioisotopes (e.g., Cu-64 chloride). As described herein, the method includes matching of the target material and the proton beam strike area, resulting in improved specific activity while reducing the amount of target material used.

Gaehle, Gregory↗

Multiaxis sensing system for detection of airborne molecules and radionuclides

Various technologies presented herein relate to a method and equipment for detecting both airborne radioisotope and molecular effluent gases. Multi-Axis Sensing can be conducted by utilizing a pressurized MOF sorbent, such as a scintillating Metal-Organic Frameworks (S-MOFs). These MOFs are crystalline nanoporous materials that have synthetic versatility that allow adjustment of pore size, chemical environment, and luminescence properties. A method for detecting an analyte in a fluid sample is provided that comprises: loading a sorbent with a sample fluid, wherein the sorbent comprises a MOF material; pressurizing the sample fluid to increase the fluid in the sorbent thereby making a pressurized sorbent; and detecting ionizing radiation or a chemical property of the analyte in the pressurized sorbent.

Allendorf, Mark D.↗