Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Single photon X-ray imaging with charge-coupled devices /CCDs/

The paper describes a CCD camera facility designed and built for testing and characterization of CCDs in response to single X-ray photons in the 1-10 keV energy range. Results from the frontside-illuminated Fairchild 211 and 221 area imagers are presented; high quantum efficiency over the 3-6 keV range was verified. In order to avoid the problem of charge spreading at the higher energies, deep-depleted CCDs for soft X-ray imaging have been constructed, and good response was obtained at 6 keV. The present results are a first step toward the demonstration of the CCD as an appropriate device for at least the central part of the focal plane of a large X-ray telescope, e.g., the proposed Advanced X-ray Astrophysics Facility.

Griffiths, R. E.↗

Technical Note: Impact on detective quantum efficiency of edge angle determination method by International Electrotechnical Commission methodology for cardiac x-ray image detectors

Purpose: Cardiac x-ray detectors are used to acquire moving images in real-time for angiography and interventional procedures. Detective quantum efficiency (DQE) is not generally measured on these dynamic detectors; the required “for processing” image data and control of x-ray settings have not been accessible. By 2016, USA hospital physicists will have the ability to measure DQE and will likely utilize the International Electrotechnical Commission (IEC) standard for measuring DQE of dynamic x-ray imaging devices. The current IEC standard requires an image of a tilted tungsten edge test object to obtain modulation transfer function (MTF) for DQE calculation. It specifies the range of edge angles to use; however, it does not specify a preferred method to determine this angle for image analysis. The study aimed to answer the question “will my choice in method impact my results?” Four different established edge angle determination methods were compared to investigate the impact on DQE. Methods: Following the IEC standard, edge and flat field images were acquired on a cardiac flat-panel detector to calculate MTF and noise power spectrum, respectively, to determine DQE. Accuracy of the methods in determining the correct angle was ascertained using a simulated edge image with known angulations. Precision of the methods was ascertained using variability of MTF and DQE, calculated via bootstrapping. Results: Three methods provided near equal angles and the same MTF while the fourth, with an angular difference of 6%, had a MTF lower by 3% at 1.5 mm{sup −1} spatial frequency and 8% at 2.5 mm{sup −1}; corresponding DQE differences were 6% at 1.5 mm{sup −1} and 17% at 2.5 mm{sup −1}; differences were greater than standard deviations in the measurements. Conclusions: DQE measurements may vary by a significant amount, depending on the method used to determine the edge angle when following the IEC standard methodology for a cardiac x-ray detector. The most accurate and precise methods are recommended for absolute assessments and reproducible measurements, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Functionalization of nitrogen vacancy-containing nanodiamonds with a metal-organic framework for quantum sensing applications

Nitrogen vacancy (NV)-containing nanodiamonds (NDs) are an important material in applications such as biological imaging, catalysis, and, in particular, quantum sensing. Careful manipulation of the surface coating on NV NDs is essential for both enhancing quantum sensor performance and for tuning selectivity towards specific sensing targets. Here, we demonstrate a simple synthetic approach for functionalizing NV NDs with the zeolitic imidazole framework-8 (ZIF-8) metal–organic framework (MOF), providing a well-ordered, porous scaffold for immobilizing target analytes near the NV ND surface. The composites were structurally characterized by x-ray diffraction, electron microscopy, and X-ray photoelectron spectroscopy, and these results were all consistent with NV NDs fully encapsulated by ZIF-8. Critically, the luminescent properties of the NV NDs, which are vital for quantum sensing experiments such as optically detected magnetic resonance (ODMR), are unchanged by the MOF coating. Moreover, spin relaxometry experiments indicate that the ZIF-8 coating significantly enhances the NV ND spin longitudinal relaxation time T1, a critical quantum parameter for sensing applications. Given the tremendous structural diversity of MOFs, the NV ND@MOF composites are an exciting material class with exciting implications for the development of high-performance quantum sensors.

Crawford, Scott↗

Final LDRD report : infrared detection and power generation using self-assembled quantum dots.

Alternative solutions are desired for mid-wavelength and long-wavelength infrared radiation detection and imaging arrays. We have investigated quantum dot infrared photodetectors (QDIPs) as a possible solution for long-wavelength infrared (8 to 12 {mu}m) radiation sensing. This document provides a summary for work done under the LDRD 'Infrared Detection and Power Generation Using Self-Assembled Quantum Dots'. Under this LDRD, we have developed QDIP sensors and made efforts to improve these devices. While the sensors fabricated show good responsivity at 80 K, their detectivity is limited by high noise current. Following efforts concentrated on how to reduce or eliminate this problem, but with no clear path was identified to the desired performance improvements.

47 OTHER INSTRUMENTATION↗

In Situ Local Imaging of Ferromagnetism and Superconductivity in RbEuFe 4 As 4

The coexistence of superconductivity and ferromagnetism is an intrinsically interesting research focus in condensed matter physics but the study is limited by low superconducting (T c ) and magnetic (T m ) transition temperatures in related materials. Here, we used a scanning superconducting quantum interference device to image the in-situ diamagnetic and ferromagnetic responses of RbEuFe 4 As 4 with high T c and T m . We observed significant suppression of superfluid density in vicinity of the magnetic phase transition, signifying fluctuation-enhanced magnetic scatterings between Eu spins and Fe 3d conduction electrons. Intriguingly, we observed multiple ferromagnetic domains which should be absent in an ideal magnetic helical phase. The formation of these domains demonstrates a weak c-axis ferromagnetic component probably arising from Eu spin-canting effect, indicative of possible superconductivity-driven domain Meissner and domain vortex-antivortex phases as revealed in EuFe 2 (As 0.79 P 0.21 ) 2 . Finally, our observations highlight RbEuFe 4 As 4 is a unique system which includes multiple interplay channels between superconductivity and ferromagnetism.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantitative geomorphologic studies from spaceborne platforms

Although LANDSAT images of our planet represent a quantum improvement in the availability of a global image-data set for independent or comparative regional geomorphic studies of landforms, such images have several limitations which restrict their suitability for quantitative geomorphic investigations. The three most serious deficiencies are: (1) photogrammetric inaccuracies, (2) two-dimensional nature of the data, and (3) spatial resolution. These deficiencies are discussed, as well as the use of stereoscopic images and laser altimeter data.

Williams, R. S., Jr.↗

WE-E-18A-01: Large Area Avalanche Amorphous Selenium Sensors for Low Dose X-Ray Imaging

Purpose: A large area indirect flat panel imager (FPI) with avalanche gain is being developed to achieve x-ray quantum noise limited low dose imaging. It uses a thin optical sensing layer of amorphous selenium (a-Se), known as High-Gain Avalanche Rushing Photoconductor (HARP), to detect optical photons generated from a high resolution x-ray scintillator. We will report initial results in the fabrication of a solid-state HARP structure suitable for a large area FPI. Our objective is to establish the blocking layer structures and defect suppression mechanisms that provide stable and uniform avalanche gain. Methods: Samples were fabricated as follows: (1) ITO signal electrode. (2) Electron blocking layer. (3) A 15 micron layer of intrinsic a-Se. (4) Transparent hole blocking layer. (5) Multiple semitransparent bias electrodes to investigate avalanche gain uniformity over a large area. The sample was exposed to 50ps optical excitation pulses through the bias electrode. Transient time of flight (TOF) and integrated charge was measured. A charge transport simulation was developed to investigate the effects of varying blocking layer charge carrier mobility on defect suppression, avalanche gain and temporal performance. Results: Avalanche gain of ∼200 was achieved experimentally with our multi-layer HARP samples. Simulations using the experimental sensor structure produced the same magnitude of gain as a function of electric field. The simulation predicted that the high dark current at a point defect can be reduced by two orders of magnitude by blocking layer optimization which can prevent irreversible damage while normal operation remained unaffected. Conclusion: We presented the first solid state HARP structure directly scalable to a large area FPI. We have shown reproducible and uniform avalanche gain of 200. By reducing mobility of the blocking layers we can suppress defects and maintain stable avalanche. Future work will optimize the blocking layers to prevent lag and ghosting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging of super-fast dynamics and flow instabilities of superconducting vortices

Quantized magnetic vortices driven by electric current determine key electromagnetic properties of superconductors. And while the dynamic behavior of slow vortices has been thoroughly investigated, the physics of ultrafast vortices under strong currents remains largely unexplored. Here, we use a nanoscale scanning superconducting quantum interference device to image vortices penetrating into a superconducting Pb film at rates of tens of GHz and moving with velocities of up to tens of km/s, which are not only much larger than the speed of sound but also exceed the pair-breaking speed limit of superconducting condensate. These experiments reveal formation of mesoscopic vortex channels which undergo cascades of bifurcations as the current and magnetic field increase. Our numerical simulations predict metamorphosis of fast Abrikosov vortices into mixed Abrikosov-Josephson vortices at even higher velocities. Our work offers an insight into the fundamental physics of dynamic vortex states of superconductors at high current densities, crucial for many applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Imaging stress and magnetism at high pressures using a nanoscale quantum sensor

Pressure alters the physical, chemical, and electronic properties of matter. The diamond anvil cell enables tabletop experiments to investigate a diverse landscape of high-pressure phenomena. In this work, we introduce and use a nanoscale sensing platform that integrates nitrogen-vacancy (NV) color centers directly into the culet of diamond anvils. We demonstrate the versatility of this platform by performing diffraction-limited imaging of both stress fields and magnetism as a function of pressure and temperature. We quantify all normal and shear stress components and demonstrate vector magnetic field imaging, enabling measurement of the pressure-driven α ↔ ϵ phase transition in iron and the complex pressure-temperature phase diagram of gadolinium. A complementary NV-sensing modality using noise spectroscopy enables the characterization of phase transitions even in the absence of static magnetic signatures.

36 MATERIALS SCIENCE↗

Monte Carlo simulation of a quantum noise limited Čerenkov detector based on air-spaced light guiding taper for megavoltage x-ray imaging

Purpose: Electronic Portal Imaging Devices (EPIDs) have been widely used in radiation therapy and are still needed on linear accelerators (Linacs) equipped with kilovoltage cone beam CT (kV-CBCT) or MRI systems. Our aim is to develop a new high quantum efficiency (QE) Čerenkov Portal Imaging Device (CPID) that is quantum noise limited at dose levels corresponding to a single Linac pulse. Methods: Recently a new concept of CPID for MV x-ray imaging in radiation therapy was introduced. It relies on Čerenkov effect for x-ray detection. The proposed design consisted of a matrix of optical fibers aligned with the incident x-rays and coupled to an active matrix flat panel imager (AMFPI) for image readout. A weakness of such design is that too few Čerenkov light photons reach the AMFPI for each incident x-ray and an AMFPI with an avalanche gain is required in order to overcome the readout noise for portal imaging application. In this work the authors propose to replace the optical fibers in the CPID with light guides without a cladding layer that are suspended in air. The air between the light guides takes on the role of the cladding layer found in a regular optical fiber. Since air has a significantly lower refractive index (∼1 versus 1.38 in a typical cladding layer), a much superior light collection efficiency is achieved. Results: A Monte Carlo simulation of the new design has been conducted to investigate its feasibility. Detector quantities such as quantum efficiency (QE), spatial resolution (MTF), and frequency dependent detective quantum efficiency (DQE) have been evaluated. The detector signal and the quantum noise have been compared to the readout noise. Conclusions: Our studies show that the modified new CPID has a QE and DQE more than an order of magnitude greater than that of current clinical systems and yet a spatial resolution similar to that of current low-QE flat-panel based EPIDs. Furthermore it was demonstrated that the new CPID does not require an avalanche gain in the AMFPI and is quantum noise limited at dose levels corresponding to a single Linac pulse.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dissecting subcycle interference in photoelectron holography

Multipath holographic interference in strong-field quantum tunnel ionization is key to revealing subangstrom attosecond dynamics for molecular movies. This critical subcycle motion is often obscured by longer timescale effects such as ring-shaped patterns that appear in above-threshold ionization (ATI). In the present work, we overcome this problem by combining two techniques in theory and experimental analysis: unit-cell averaging and time-filtering data and simulations. Together these suppress ATI rings and enable an unprecedented highly detailed quantitative match between strong-field ionization experiments in argon and the Coulomb-quantum orbit strong-field approximation (CQSFA) theory. Velocity map images reveal fine modulations on the holographic spiderlike interference fringes that form near the polarization axis. CQSFA theory traces this to the interference of three types of electron pathways. The level of agreement between experiment and theory allows sensitive determination of quantum phase differences and symmetries, providing an important tool for quantitative dynamical imaging in quantum systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

Review – Quantum Dots and Their Application in Lighting, Displays, and Biology

In this review, we focus on the advancement of white light emitting nanocrystals, their usage as the emissive layer in LEDs and display backlights, and examine the increased efficiency and longevity of quantum dots based colored LEDs. In addition, we also explore recent discoveries on quantum dots as biological labels, dynamic trackers, and applications in drug delivery.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

System for Spectral Characterization of Solar Cell Structures

The spectral characterization system presented in this work is one based on a monochromator and it is able to deliver an under - millimeter spot size. The system is fully controlled by computer, shows good repeatability and high accuracy in spectral characterization of photovoltaic devices by the determination of internal quantum efficiency over an extended wavelength range. Two solutions for extended range detectors are explored in this study: pyroelectric and sandwich detectors. Most of the results shown in this abstract were obtained using a pyroelectric detector. The full version of the paper will show a comparison between the two types of detectors. Scanning images (maps) of internal quantum efficiency (IQE) and of external quantum efficiency (QE) can be obtained with high spatial resolution both in AC and DC mode. I-V curves can be obtained in monochromatic or white light in the same location as the IQE curves without a supplemental repositioning. Because IQE curves and I-V curves are obtained in the same location and using the same optics, a full characterization of the photovoltaic device under test is possible in a single run.

14 SOLAR ENERGY↗

Continuous-variable quantum Boltzmann machine

Here, we propose a continuous-variable quantum Boltzmann machine (CVQBM) using a powerful energy-based neural network. It can be realized experimentally on a continuous-variable (CV) photonic quantum computer. We used a CV quantum imaginary time evolution (QITE) algorithm to prepare the essential thermal state and then designed the CVQBM to proficiently generate continuous probability distributions. We applied our method to both classical and quantum data. Using real-world classical data, such as synthetic-aperture radar (SAR) images, we generated probability distributions. For quantum data, we used the output of CV quantum circuits. We obtained high fidelity and low Kullback–Leibler (KL) divergence showing that our CVQBM learns distributions from given data well and generates data sampling from that distribution efficiently. We also discussed the experimental feasibility of our proposed CVQBM. Our method can be applied to a wide range of real-world problems by choosing an appropriate target distribution (corresponding to, e.g., SAR images, medical images, and risk management in finance). Moreover, our CVQBM is versatile and could be programmed to perform tasks beyond generation, such as anomaly detection.

SAR images↗

Modelling the mechanisms of quantum logic using the method of superimposed Fourier holograms based on the nonlinearity of the exposure characteristics of holographic recording media

A Fourier-holography scheme with superimposed holograms and phase conjugation is considered. It is shown that the sub-holograms, arising from the recording of superimposed holograms due to quadratic nonlinearity of the exposure characteristics of holographic recording media, form the connections necessary for the realisation of the quantum-logic mechanism of sequential projection of the input vector onto the subspaces of the recorded images. A classical mechanism of the ‘Linda’ cognitive phenomenon belonging to the category of quantum-like ones is described. An experimental illustration of the self-sustained formation of sub-holograms due to the nonlinearity of the exposure characteristics of holographic recording media is given. (quantum logic)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗