Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

DR-RINS: Digital real-time relative intensity noise suppressor for pump–probe spectroscopy and microscopy

Relative intensity noise (RIN) inherent in fiber lasers poses a serious obstacle to their use in pump–probe spectroscopy and imaging. RIN can be removed through an analog balanced detector, or, as we have previously shown, software adaptive noise cancellation (ANC) on digitized signals. One major drawback to software ANC is the added time required for digitizing and post-processing. In this article, we describe a design for ANC on a field-programmable gate array (FPGA), making use of high-level synthesis tools and fixed-point arithmetic to achieve real-time laser RIN suppression at 25 MHz sample rates. Unlike the software-ANC approach, the FPGA-ANC device can serve as a dedicated drop-in denoiser, placed between the detectors and a commercial lock-in amplifier. We demonstrate its application to transient absorption spectroscopy and microscopy, lowering the noise floor to ~17 dB above the shot noise limit. Furthermore, we demonstrate a dramatic improvement in data acquisition time from ~6 h to ~5 min in a real-time imaging scenario.

47 OTHER INSTRUMENTATION↗

Imaging surface plasmon polaritons using proximal self-assembled InGaAs quantum dots

We present optical investigations of hybrid plasmonic nanosystems consisting of lithographically defined plasmonic Au-waveguides or beamsplitters on GaAs substrates coupled to proximal self-assembled InGaAs quantum dots. We designed a sample structure that enabled us to precisely tune the distance between quantum dots and the sample surface during nano-fabrication and demonstrated that non-radiative processes do not play a major role for separations down to ∼10 nm. A polarized laser beam focused on one end of the plasmonic nanostructure generates propagating surface plasmon polaritons that, in turn, create electron-hole pairs in the GaAs substrate during propagation. These free carriers are subsequently captured by the quantum dots ∼25 nm below the surface, giving rise to luminescence. The intensity of the spectrally integrated quantum dot luminescence is used to image the propagating plasmon modes. As the waveguide width reduces from 5 μm to 1 μm, we clearly observe different plasmonic modes at the remote waveguide end, enabling their direct imaging in real space. This imaging technique is applied to a plasmonic beamsplitter facilitating the determination of the splitting ratio between the two beamsplitter output ports as the interaction length L{sub i} is varied. A splitting ratio of 50:50 is observed for L{sub i}∼9±1 μm and 1 μm wide waveguides for excitation energies close to the GaAs band edge. Our experimental findings are in good agreement with mode profile and finite difference time domain simulations for both waveguides and beamsplitters.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Bianthrone at a metal surface: Conductance switching with a bistable molecule made feasible by image charge effects

Bianthrone is a sterically hindered compound that exists in the form of two non-planar isomers. Our experimental study of single-molecule junctions with bianthrone reveals persistent switching of electric conductance at low temperatures, which can be reasonably associated to molecular isomerization events. Temperature dependence of the switching rate allows for an estimate of the activation energy of the process, on the order of 35–90 meV. Quantum-chemical calculations of the potential surface of neutral bianthrone and its anion, including identification of transition states, yields the isolated molecule isomerization barriers too high vs. the previous estimate, though in perfect agreement with previous experimental studies in solution. Nevertheless, we show that the attraction of the anion in the vicinity of the metal surface by its image charge can significantly alter the energetic landscape, in particular, by reducing the barrier to the values compatible with the observed switching behavior.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Synthesis of silver nanospheroids in silver-containing nanoporous glass under the effect of nanosecond laser pulses

Experimental evidence is presented that nanosecond laser irradiation of nanoporous silicate glass containing subnanometre Ag{sub n} molecular silver clusters leads to the formation of spheroidal silver nanoparticles in the glass pores. Their shape has been confirmed by numerical simulation and electronic-microscopic images. The main processes induced by laser irradiation are local heating and the photoionisation and photofragmentation of the molecular silver clusters, followed by the aggregation of the fragments of the molecular clusters into nanoparticles. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Statistical analysis of AFM topographic images of self-assembled quantum dots

To obtain statistical data on quantum-dot sizes, AFM topographic images of the substrate on which the dots under study are grown are analyzed. Due to the nonideality of the substrate containing height differences on the order of the size of nanoparticles at distances of 1-10 {mu}m and the insufficient resolution of closely arranged dots due to the finite curvature radius of the AFM probe, automation of the statistical analysis of their large dot array requires special techniques for processing topographic images to eliminate the loss of a particle fraction during conventional processing. As such a technique, convolution of the initial matrix of the AFM image with a specially selected matrix is used. This makes it possible to determine the position of each nanoparticle and, using the initial matrix, to measure their geometrical parameters. The results of statistical analysis by this method of self-assembled InAs quantum dots formed on the surface of an AlGaAs epitaxial layer are presented. It is shown that their concentration, average size, and half-width of height distribution depend strongly on the In flow and total amount of deposited InAs which are varied within insignificant limits.

36 MATERIALS SCIENCE↗

Collection of fluorescence from an ion using trap-integrated photonics

Spontaneously emitted photons are entangled with the electronic and nuclear degrees of freedom of the emitting atom, so interference and measurement of these photons can entangle separate matter-based quantum systems as a resource for quantum information processing. Since confinement in a single-mode facilitates the photon interference needed for generating entanglement, the dipole emission patterns relevant in spontaneous emission present a mode-matching challenge. Current demonstrations rely on bulk photon-collection and manipulation optics that suffer from large component size and system-to-system variability—factors that impede scaling to the large numbers of entangled pairs needed for quantum information processing. To address these limitations, we demonstrate a collection method that enables passive phase stability, straightforward photonic manipulation, and intrinsic reproducibility. Specifically, we engineer a waveguide-integrated grating to couple photons emitted from a trapped ion into a single optical mode within a microfabricated ion-trap chip. Using the integrated collection optic, we characterize the collection efficiency, image the ion, and detect the ion’s quantum state. The integrated optic covers 2.18% of the solid angle and collects 1.97 ± 0.3% of the spontaneously emitted light incident on the grating for a total collection efficiency of 0.043% into a single-mode waveguide. This proof-of-principle demonstration lays the foundation for leveraging the inherent stability and reproducibility of integrated photonics to create, manipulate, and measure multipartite quantum states in arrays of quantum emitters.

Optical physics↗

Giant enhancement of nanoscale thermal radiation based on hyperbolic graphene plasmons

Excitation of surface plasmons enables super-Planckian thermal radiation far beyond the blackbody limit. By patterning a single layer of graphene sheet into ribbons, the closed circular dispersion of graphene plasmons is opened to become hyperbolic, leading to broadband singularities of density of states. Extremely high- k evanescent waves can now couple with hyperbolic graphene plasmons. Consequently, a giant enhancement of the near-field radiative heat flux, by more than one order of magnitude, is demonstrated here using rigorous numerical simulations. The findings may open promising pathways for highly efficient thermal management, energy harvesting, and sub-wavelength thermal imaging.

36 MATERIALS SCIENCE↗

Transducer selection and application in magnetoacoustic tomography with magnetic induction

As an acoustic receiver, transducer plays a vital role in signal acquisition and image reconstruction for magnetoacoustic tomography with magnetic induction (MAT-MI). In order to optimize signal acquisition, the expressions of acoustic pressure detection and waveform collection are theoretically studied based on the radiation theory of acoustic dipole and the reception pattern of transducer. Pressure distributions are simulated for a cylindrical phantom model using a planar piston transducer with different radii and bandwidths. The proposed theory is also verified by the experimental measurements of acoustic waveform detection for an aluminum foil cylinder. It is proved that acoustic pressure with sharp and clear boundary peaks can be detected by the large-radius transducer with wide bandwidth, reflecting the differential of the induced Lorentz force accurately, which is helpful for precise conductivity reconstruction. To detect acoustic pressure with acceptable pressure amplitude, peak pressure ratio, amplitude ratio, and improved signal to noise ratio, the scanning radius of 5–10 times the radius of the object should be selected to improve the accuracy of image reconstruction. This study provides a theoretical and experimental basis for transducer selection and application in MAT-MI to obtain reconstructed images with improved resolution and definition.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spontaneous wrinkling of soft matter by energetic deposition of Cr and Au

Wrinkling of stiff thin films deposited on compliant substrates is an effect that has been broadly investigated. However, wrinkling consequent to metal ion implantation has been less studied. In the work described here, we have explored the sub-micron wrinkling phenomena that spontaneously occur when metal ions (Au and Cr) are implanted with energy of a few tens of electron volts (49 eV for Au and 72 eV for Cr) into a compliant material (PDMS). This very low energy ion implantation was performed using a Filtered Cathodic Vacuum Arc technique, a process often referred to as energetic deposition or energetic condensation. For comparison, Au and Cr depositions with similar doses were also done using a sputtering technique (with lower particle energy of approximately 2 eV), and no wrinkle formation was then observed. In this way, we can discuss the role of ion energy in wrinkle formation. Depth profiles of the implanted material were calculated using the Tridyn computer simulation code for each metal, for several implantation doses. UV-vis absorption spectroscopy analysis confirmed the presence of metal nanoparticles. Atomic Force Microscopy imaging with spectral processing was used to compare the wrinkle morphology for each case investigated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sensitivity analysis of a geometric calibration method using projection matrices for digital tomosynthesis systems

Purpose: To study the sensitivity of a geometric calibration method using projection matrices for digital tomosynthesis systems. Methods: A generic geometric calibration method for tomographic imaging systems has been presented in our previous work. The method involves a scan of a calibration phantom with multiple markers. Their locations in projection images are detected and are associated with their 3D coordinates to compute 3x4 projection matrices, which can be used in subsequent image reconstruction. The accuracy of geometric calibration may be affected by errors in the input data of marker positions. The effects of errors may depend on the number of markers and the volume surrounded by them in 3D space. This work analyzed the sensitivity of the calibration method to the above factors. A 6 cm CIRS breast research phantom and a prototype breast tomosynthesis system were used for our tests. A high contrast ring and two small speck groups were reconstructed in various testing cases for comparison. To achieve quantitative assessment, a 15x15 point detection mask was adopted for detecting signals and for computing changes between testing cases and the regular geometric calibration. Results: When 3D coordinates and 2D projections of markers were accurate, all tested numbers of markers, 6-44, provided similar high quality reconstructions of the ring and the two speck groups. Errors in marker positions resulted in image degradations and signal changes, which increased with fewer markers and smaller volume surrounded by markers in the 3D object space. Signal changes of small specks were more significant than those of the ring. Errors in marker projections produced drastic image degradations. Coplanar marker placement caused a failure in projection matrix computation. Conclusions: For practical geometric calibration phantom design, ample markers are desired. They need to have a large volumetric coverage in the 3D space and be far from being coplanar. Precise determination of marker projections on detector planes is crucial for accurate geometric calibration and for small object detection using the reconstructed images.

60 APPLIED LIFE SCIENCES↗

THE BLANCO COSMOLOGY SURVEY: DATA ACQUISITION, PROCESSING, CALIBRATION, QUALITY DIAGNOSTICS, AND DATA RELEASE

The Blanco Cosmology Survey (BCS) is a 60 night imaging survey of {approx}80 deg{sup 2} of the southern sky located in two fields: ({alpha}, {delta}) = (5 hr, -55 Degree-Sign ) and (23 hr, -55 Degree-Sign ). The survey was carried out between 2005 and 2008 in griz bands with the Mosaic2 imager on the Blanco 4 m telescope. The primary aim of the BCS survey is to provide the data required to optically confirm and measure photometric redshifts for Sunyaev-Zel'dovich effect selected galaxy clusters from the South Pole Telescope and the Atacama Cosmology Telescope. We process and calibrate the BCS data, carrying out point-spread function-corrected model-fitting photometry for all detected objects. The median 10{sigma} galaxy (point-source) depths over the survey in griz are approximately 23.3 (23.9), 23.4 (24.0), 23.0 (23.6), and 21.3 (22.1), respectively. The astrometric accuracy relative to the USNO-B survey is {approx}45 mas. We calibrate our absolute photometry using the stellar locus in grizJ bands, and thus our absolute photometric scale derives from the Two Micron All Sky Survey, which has {approx}2% accuracy. The scatter of stars about the stellar locus indicates a systematic floor in the relative stellar photometric scatter in griz that is {approx}1.9%, {approx}2.2%, {approx}2.7%, and {approx}2.7%, respectively. A simple cut in the AstrOmatic star-galaxy classifier spread{sub m}odel produces a star sample with good spatial uniformity. We use the resulting photometric catalogs to calibrate photometric redshifts for the survey and demonstrate scatter {delta}z/(1 + z) = 0.054 with an outlier fraction {eta} < 5% to z {approx} 1. We highlight some selected science results to date and provide a full description of the released data products.

79 ASTRONOMY AND ASTROPHYSICS↗

Delta-Doping at Wafer Level for High Throughput, High Yield Fabrication of Silicon Imaging Arrays

Systems and methods for producing high quantum efficiency silicon devices. A silicon MBE has a preparation chamber that provides for cleaning silicon surfaces using an oxygen plasma to remove impurities and a gaseous (dry) NH3 + NF3 room temperature oxide removal process that leaves the silicon surface hydrogen terminated. Silicon wafers up to 8 inches in diameter have devices that can be fabricated using the cleaning procedures and MBE processing, including delta doping.

Hoenk, Michael E.↗

Phonon-mediated sticking of electrons at dielectric surfaces

We study phonon-mediated temporary trapping of an electron in polarization-induced external surface states (image states) of a dielectric surface. Our approach is based on a quantum-kinetic equation for the occupancy of the image states. It allows us to distinguish between prompt and kinetic sticking. Because the depth of the image potential is much larger than the Debye energy multiphonon processes are important. Taking two-phonon processes into account in cases where one-phonon processes yield a vanishing transition probability, as it is applicable, for instance, to graphite, we analyze the adsorption scenario as a function of potential depth and surface temperature and calculate prompt and kinetic sticking coefficients. We find rather small sticking coefficients, at most on the order of 10{sup -3}, and a significant suppression of the kinetic sticking coefficient due to a relaxation bottleneck inhibiting thermalization of the electron with the surface at short time scales.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A convenient method of preparing gene vector for real time monitoring transfection process based on the quantum dots

Highlights: ► An easy and direct way to prepare QDs–DNA complexes was developed. ► Surface charge of QDs was tuned with different ratio of amino and glycolate. ► Transfection efficiency was dependent on the surface zeta potentials of QDs. ► Cellular toxicity of this gene vectors is much lower than commercial liposome. ► Whole intracellular behavior of QDs–DNA complexes can be monitored in real time. -- Abstract: Nanoparticle carrier has been developed by combining water-soluble quantum dots and plasmid DNA expressed enhanced green fluorescent protein (EGFP) in a convenient and direct way. First the QDs with different surface charges were obtained by coating with amino and carboxyl terminals at different ratios. Then plasmid DNA was conjugated to QDs via electrostatic interaction. The resultant QDs–DNA complexes showed enhanced resistance to DNase I digestion. The following transfection experiments demonstrated that the transfection efficiency was dependent on the surface charges on QDs. The real time imaging of the transfection process showed that the nanoparticles experienced binding, penetrating the cell membrane and entering cytoplasm in the first 6 h of transfection. The green fluorescence of EGFP began to appear after 18 h transfection and plasmid DNA was fully expressed in the following 6 h. This new QDs–DNA platform showed great potential as new gene delivery carrier.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Correlating Superconducting Qubit Performance Losses to Sidewall Near-Field Scattering via Terahertz Nanophotonics

Elucidating dielectric losses, structural heterogeneity, and interface imperfections is critical for improving coherence in superconducting qubits. However, most diagnostics rely on destructive electron microscopy or low-throughput millikelvin quantum measurements. Here, we demonstrate noninvasive terahertz (THz) nano-imaging/-spectroscopy of encapsulated niobium transmon qubits, revealing sidewall near-field scattering that correlates with qubit coherence. We further employ a THz hyperspectral line scan to probe dielectric responses and field participation at Al junction interfaces. These findings highlight the promise of THz near-field methods as a high-throughput proxy characterization tool for guiding material selection and optimizing processing protocols to improve qubit and quantum circuit performance.

Kim, Richard H.J. [Ames Lab]↗

SU-G-IeP3-11: On the Utility of Pixel Variance to Characterize Noise for Image Receptors of Digital Radiography Systems

Purpose: To characterize noise for image receptors of digital radiography systems based on pixel variance. Methods: Nine calibrated digital image receptors associated with nine new portable digital radiography systems (Carestream Health, Inc., Rochester, NY) were used in this study. For each image receptor, thirteen images were acquired with RQA5 beam conditions for input detector air kerma ranging from 0 to 110 µGy, and linearized ‘For Processing’ images were extracted. Mean pixel value (MPV), standard deviation (SD) and relative noise (SD/MPV) were obtained from each image using ROI sizes varying from 2.5×2.5 to 20×20 mm{sup 2}. Variance (SD{sup 2}) was plotted as a function of input detector air kerma and the coefficients of the quadratic fit were used to derive structured, quantum and electronic noise coefficients. Relative noise was also fitted as a function of input detector air kerma to identify noise sources. The fitting functions used least-squares approach. Results: The coefficient of variation values obtained using different ROI sizes was less than 1% for all the images. The structured, quantum and electronic coefficients obtained from the quadratic fit of variance (r>0.97) were 0.43±0.10, 3.95±0.27 and 2.89±0.74 (mean ± standard deviation), respectively, indicating that overall the quantum noise was the dominant noise source. However, for one system electronic noise coefficient (3.91) was greater than quantum noise coefficient (3.56) indicating electronic noise to be dominant. Using relative noise values, the power parameter of the fitting equation (|r|>0.93) showed a mean and standard deviation of 0.46±0.02. A 0.50 value for this power parameter indicates quantum noise to be the dominant noise source whereas values around 0.50 indicate presence of other noise sources. Conclusion: Characterizing noise from pixel variance assists in identifying contributions from various noise sources that, eventually, may affect image quality. This approach may be integrated during periodic quality assessments of digital image receptors.

60 APPLIED LIFE SCIENCES↗

Real-Time Vehicle-Mounted Multistatic Ground Penetrating Radar Imaging System for Buried Object Detection

A multistatic ground penetrating radar system is described, capable of real-time imaging and object detection. The radar consists of 16 transmitter and receiver pairs mounted across the front of a vehicle. The transmitters operate sequentially with all receivers activated for each transmit pulse. The resulting frame of 256 multistatic time signals is processed into an image using a tomographic reconstruction technique. In this paper we describe the system architecture, signal conditioning, and reconstruction algorithm for producing a sequence of images in real time as the vehicle travels across the ground. We demonstrate a robust image post-processing method that separates the bright spot corresponding to the dominant buried object in an image frame from the background. This is essential before calculating an energy-based statistic for automatic detection of buried objects. This spot ratio detection statistic, based on energy both inside and outside the spot, is shown to be not only more stationary than spot energy (i.e. mostly free of localized trends due to changing ground conditions), but also more powerful as a detection statistic. Finally, we demonstrate that multistatic imaging significantly improves the detection performance over more conventional monostatic array processing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗