Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quality installation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Metrication report to the Congress. 1991 activities and 1992 plans

During 1991, NASA approved a revised metric use policy and developed a NASA Metric Transition Plan. This Plan targets the end of 1995 for completion of NASA's metric initiatives. This Plan also identifies future programs that NASA anticipates will use the metric system of measurement. Field installations began metric transition studies in 1991 and will complete them in 1992. Half of NASA's Space Shuttle payloads for 1991, and almost all such payloads for 1992, have some metric-based elements. In 1992, NASA will begin assessing requirements for space-quality piece parts fabricated to U.S. metric standards, leading to development and qualification of high priority parts.

Source record↗

Breadboard Facility

In the sixties, Chrysler was NASA's prime contractor for the Saturn I and IB test launch vehicles. The company installed and operated at Huntsville what was known as the Saturn I/IB Development Breadboard Facility. "Breadboard," means an array of electrical and electronic equipment for performing a variety of development and test functions. This work gave Chrysler a broad capability in computerized testing to assure quality control in development of solid-state electronic systems. Today that division is manufacturing many products not destined for NASA, most of them being associated with the company's automotive line. A major project is production and quality-control testing of the "lean-burn" engine, one that has a built-in Computer to control emission timing, and allow the engine to run on a leaner mixture of fuel and air. Other environment-related products include vehicle emission analyzers. The newest of the line is an accurate, portable solid state instrument for testing auto exhaust gases. The exhaust analyzers, now being produced for company dealers and for service

Source record↗

JSC Case Study: Fleet Experience with E-85 Fuel

JSC has used E-85 as part of an overall strategy to comply with Presidential Executive Order 13423 and the Energy Policy Act. As a Federal fleet, we are required to reduce our petroleum consumption by 2 percent per year, and increase the use of alternative fuels in our vehicles. With the opening of our onsite dispenser in October 2004, JSC became the second federal fleet in Texas and the fifth NASA center to add E-85 fueling capability. JSC has a relatively small number of GSA Flex Fuel fleet vehicles at the present time (we don't include personal vehicles, or other contractor's non-GSA fleet), and there were no reasonably available retail E-85 fuel stations within a 15-minute drive or within five miles (one way). So we decided to install a small 1000 gallon onsite tank and dispenser. It was difficult to obtain a supplier due to our low monthly fuel consumption, and our fuel supplier contract has changed three times in less than five years. We experiences a couple of fuel contamination and quality control issues. JSC obtained good information on E-85 from the National Ethanol Vehicle Coalition (NEVC). We also spoke with Defense Energy Support Center, (DESC), Lawrence Berkeley Laboratory, and US Army Fort Leonard Wood. E-85 is a liquid fuel that is dispensed into our Flexible Fuel Vehicles identically to regular gasoline, so it was easy for our vehicle drivers to make the transition.

Hummel, Kirck↗

A Method For The Verification Of Wire Crimp Compression Using Ultrasonic Inspection

The development of a new ultrasonic measurement technique to assess quantitatively wire crimp terminations is discussed. The amplitude change of a compressional ultrasonic wave propagating at right angles to the wire axis and through the junction of a crimp termination is shown to correlate with the results of a destructive pull test, which is a standard for assessing crimp wire junction quality. To demonstrate the technique, the case of incomplete compression of crimped connections is ultrasonically tested, and the results are correlated with pull tests. Results show that the nondestructive ultrasonic measurement technique consistently predicts good crimps when the ultrasonic transmission is above a certain threshold amplitude level. A quantitative measure of the quality of the crimped connection based on the ultrasonic energy transmitted is shown to respond accurately to crimp quality. A wave propagation model, solved by finite element analysis, describes the compressional ultrasonic wave propagation through the junction during the crimping process. This model is in agreement within 6% of the ultrasonic measurements. A prototype instrument for applying this technique while wire crimps are installed is also presented. The instrument is based on a two-jaw type crimp tool suitable for butt-splice type connections. A comparison of the results of two different instruments is presented and shows reproducibility between instruments within a 95% confidence bound.

Cramer, K. E.↗

Thermodynamic Vent System for an On-Orbit Cryogenic Reaction Control Engine

A report discusses a cryogenic reaction control system (RCS) that integrates a Joule-Thompson (JT) device (expansion valve) and thermodynamic vent system (TVS) with a cryogenic distribution system to allow fine control of the propellant quality (subcooled liquid) during operation of the device. It enables zero-venting when coupled with an RCS engine. The proper attachment locations and sizing of the orifice are required with the propellant distribution line to facilitate line conditioning. During operations, system instrumentation was strategically installed along the distribution/TVS line assembly, and temperature control bands were identified. A sub-scale run tank, full-scale distribution line, open-loop TVS, and a combination of procured and custom-fabricated cryogenic components were used in the cryogenic RCS build-up. Simulated on-orbit activation and thruster firing profiles were performed to quantify system heat gain and evaluate the TVS s capability to maintain the required propellant conditions at the inlet to the engine valves. Test data determined that a small control valve, such as a piezoelectric, is optimal to provide continuously the required thermal control. The data obtained from testing has also assisted with the development of fluid and thermal models of an RCS to refine integrated cryogenic propulsion system designs. This system allows a liquid oxygenbased main propulsion and reaction control system for a spacecraft, which improves performance, safety, and cost over conventional hypergolic systems due to higher performance, use of nontoxic propellants, potential for integration with life support and power subsystems, and compatibility with in-situ produced propellants.

Hurlbert, Eric A.↗

Stream discharge and temperature data collected within the East and Taylor Watershed, Colorado for the Lawrence Berkeley National Laboratory Watershed Function Science Focus Area (water years 2019 to 2025)

This dataset contains stream discharge and temperature data for water years 2019 to 2025 from the East and Taylor Watersheds in Colorado, United States. This data was collected to understand hydrological processes occurring in the East River and Taylor River Watersheds, Colorado, which is part of the Lawrence Berkeley National Laboratory Watershed Function Scientific Focus Area. Data includes instantaneous observed discharge using salt dilution and acoustic doppler velocimeter techniques, raw pressure transducer downloaded data, sub-hourly temperature as well as corrected water level and associated stream discharge and mean daily values. Notes on water level corrections, rating curve development and metadata provided. A rating curve is the translation of depth to streamflow. The rating curve can be used as a quantitative measure of the “quality of the data.” Data within this dataset is formatted using ESS-DIVE’s Hydrological Monitoring Reporting Format. This data package contains (1) a zip file (Stream_Discharge_Data_WY19-WY25.zip) containing stream discharge and temperature data organized by location; (2) an InstallationMethods file (InstallationMethods.csv) describing metadata about the installation; (3) a file-level metadata (flmd.csv) file that lists each file contained in the dataset with associated metadata; (4) a data dictionary (dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; (5) a locations metadata file (locations.csv); (6) and a sensor metadata file (sensors.csv). All data files are in non-proprietary formats (csv, png, or pdf formats). Please contact Rosemary Carroll, Curtis Beutler, or Austin Shirley for any support in accessing the files. Update on 2023-05-12: Additional data from WYs 2021 and 2022 were added. Additionally, the dataset was converted using ESS-DIVE’s Hydrological Monitoring Reporting Format. Data files were reformatted to match reporting format guidance, new metadata files were added, and files were converted from excel to CSV. Update on 2025-05-16: Additional data from WYs 2022 (for locations not previously included), 2023, and 2024 were added. An additional descriptive PDF (WFSFA_Streamflow_Hydrograph_Disclaimer.pdf) was added. Metadata files were updated to reflect the addition of new data and locations. Update on 2026-05-18: Additional data from WY 2025 were added, including a new location Upper Trail Creek (TR-TCG2). Metadata files were updated to reflect the addition of new data.

54 ENVIRONMENTAL SCIENCES↗

Specific conductivity, pH, dissolved oxygen, water temperature, alkalinity and sulfide in-situ data; Slate River floodplain, Crested Butte, CO; May 2020-October 2020

This data package includes a time-series of field measurements from May to October 2020 in groundwater and surface water from the Slate River floodplain in Crested Butte, CO, a focus field site for the SLAC Floodplain Hydro-Biogeochemistry SFA. The data was generated as part of the work targeting the overarching research question for the SLAC SFA: How do ubiquitous subsurface interfaces mediate molecular-scale biogeochemical processes and groundwater quality in floodplains and watersheds? The data packade includes 6 data files, one for each measured variable: specific conductivity, pH, dissolved oxygen, water temperature, alkalinity and sulfide. All measurements were recorded in the field immediately after water sampling. Groundwater samples were extracted from a network of installed rhizons (Rhizosphere Research Products, part no. 19.60.21F, 0.6 micrometer mesh size) and piezometer wells within the floodplain. In addition to the data files, there is a terminology file explaining the terms used, a file level metadata file, and a sensor file with metadata about the sensors used.All files are in csv format.

54 ENVIRONMENTAL SCIENCES↗

Comprehensive helicopter rotor instrumentation - A retrofit approach using miniature transducers

This paper reports an approach used to retrofit a set of full-scale main rotor blades with 290 miniature pressure transducers, 46 strain gages, and 24 miniature accelerometers. Normally, in order to avoid disturbing the aerodynamics of the rotor flow field, the pressure instrumentation must be integrally built into the body of the rotor blades. However, using a method developed with NASA, miniature pressure transducers are mounted to the blade exterior surface without degrading the quality of the blade aerodynamics. Moreover, it is estimated that this approach reduced costs by more than 50 percent over building a set of pressure instrumented blades. The aerodynamic measurement objectives are presented as are instrumentation design considerations, type of instrumentation used, assembly process, and the installed instrumentation characteristics.

Jacklin, Stephen A.↗

A New Forced Oscillation Capability for the Transonic Dynamics Tunnel

A new forced oscillation system has been installed and tested at NASA Langley Research Center's Transonic Dynamics Tunnel (TDT). The system is known as the Oscillating Turntable (OTT) and has been designed for the purpose of oscillating, large semispan models in pitch at frequencies up to 40 Hz to acquire high-quality unsteady pressure and loads data. Precisely controlled motions of a wind-tunnel model on the OTT can yield unsteady aerodynamic phenomena associated with flutter, limit cycle oscillations, shock dynamics, and non-linear aerodynamic effects on many vehicle configurations. This paper will discuss general design and components of the OTT and will present test data from performance testing and from research tests on two rigid semispan wind-tunnel models. The research tests were designed to challenge the OTT over a wide range of operating conditions while acquiring unsteady pressure data on a small rectangular supercritical wing and a large supersonic transport wing. These results will be presented to illustrate the performance capabilities, consistency of oscillations, and usefulness of the OTT as a research tool.

Piatak, David J.↗

Diagnostic Techniques Used to Study Chemical-Vapor-Deposited Diamond Films

The advantages and utility of chemical-vapor-deposited (CVD) diamond as an industrial ceramic can only be realized if the price and quality are right. Until recently, this technology was of interest only to the academic and basic research community. However, interest has grown because of advances made by leading CVD diamond suppliers: 1) Reduction of the cost of CVD polycrystalline diamond deposition below $5/carat ($8/sq cm); 2) Installation of production capacity; 3) Epitaxial growth of CVD single-crystal diamond. Thus, CVD diamond applications and business are an industrial reality. At present, CVD diamond is produced in the form of coatings or wafers. CVD diamond film technology offers a broader technological potential than do natural and high-pressure synthetic diamonds because size, geometry, and eventually cost will not be as limiting. Now that they are cost effective, diamond coatings - with their extreme properties - can be used in a variety of applications. Diamond coatings can improve many of the surface properties of engineering substrate materials, including erosion, corrosion, and wear resistance. Examples of actual and potential applications, from microelectromechanical systems to the wear parts of diamond coatings and related superhard coatings are described. For example, diamond coatings can be used as a chemical and mechanical barrier for the space shuttles check valves, particularly on the guide pins and seat assemblies.

Miyoshi, Kazuhisa↗

In-Flight Performance of Wide Field Camera 3

Wide Field Camera 3 (WFC3), a powerful new UVNisible/IR imager, was installed into HST during Servicing Mission 4. After a successful commissioning in the Servicing Mission Orbital Verification program, WFC3 has been engaged in an exciting program of scientific observations. I review here the in-flight scientific performance of the instrument, addressing such topics as image quality, sensitivity, detector performance, and stability.

Kimble, Randy↗

Bearing tester data compilation analysis, and reporting and bearing math modeling

Integration of heat transfer coefficients, modified to account for local vapor quality, into the 45 mm bearing model has been completed. The model has been evaluated with two flow rates and subcooled and saturated coolant. The evaluation showed that by increasing the flow from 3.6 to 7.0 lbs/sec the average ball temperature was decreased by 102 F, using a coolant temperature of -230 F. The average ball temperature was decreased by 63 F by decreasing the inlet coolant temperature from saturated to -230 F at a flow rate of 7.0 lbs/sec. Since other factors such as friction, cage heating, etc., affect bearing temperatures, the above bearing temperature effects should be considered as trends and not absolute values. The two phase heat transfer modification has been installed in the 57 mm bearing model and the effects on bearing temperatures have been evaluated. The average ball temperature was decreased by 60 F by increasing the flow rate from 4.6 to 9.0 lbs/sec for the subcooled case. By decreasing the inlet coolant temperature from saturation to -24 F, the average ball temperature was decreased 57 F for a flow rate of 9.0 lbs/sec. The technique of relating the two phase heat transfer coefficient to local vapor quality will be applied to the tester model and compared with test data.

Cody, J. C.↗

NASIS data base management system - IBM 360/370 OS MVT implementation. 1: Installation standards

The installation standards for the NASA Aerospace Safety Information System (NASIS) data base management system are presented. The standard approach to preparing systems documentation and the program design and coding rules and conventions are outlined. Included are instructions for preparing all major specifications and suggestions for improving the quality and efficiency of the programming task.

Source record↗

Low frequency, 100–600 MHz, searches with axion cavity haloscopes

We investigate reentrant and dielectric loaded cavities for the purpose of extending the range of axion cavity haloscopes to lower masses, below the range where the Axion Dark Matter experiment (ADMX) has already searched. Reentrant and dielectric loaded cavities were simulated numerically to calculate and optimize their form factors and quality factors. A prototype reentrant cavity was built and its measured properties were compared with the simulations. We estimate the sensitivity of axion dark matter searches using reentrant and dielectric loaded cavities inserted in the existing ADMX magnet at the University of Washington and a large magnet being installed at Fermilab. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alpha Spectrometry Results for Groundwater Samples Collected in Northern Iraq and a Summary of the Environmental Setting of the Adaya Burial Site

The Radiation Protection Center (RPC) of the Iraqi Ministry of Environment continues to evaluate the potential health impacts associated with the Adaya Burial Site, which is located 33 kilometers (20.5 miles) southwest of Mosul. This report documents the radiological analyses of 16 groundwater samples collected from wells located in the vicinity of the Adaya Burial Site and at other sites in northern Iraq. The Adaya Burial Site is a high-risk dump site because a large volume of radioactive material and contaminated soil is located on an unsecure hillside above the village of Tall ar Ragrag. The uranium activities for the 16 water samples in northern Iraq are considered to be naturally occurring and do not indicate artificial (man-made) contamination. With one exception, the alpha spectrometry results for the 16 wells that were sampled in 2019 indicate that the water quality concerning the three uranium isotopes (Uranium-233/234, Uranium-235/236, and Uranium-238) was acceptable for potable purposes (drinking and cooking). However, Well 7 in Mosul had a Uranium-233/234 activity concentration that slightly exceeded the World Health Organization guidance level. Eight of the 16 wells are located in the villages of Tall ar Ragrag and Adaya and had naturally occurring uranium concentrations. Wells in the villages of Tall ar Ragrag and Adaya are located near the Adaya Burial Site and should be sampled on an annual schedule. The list of groundwater analytes should include metals, total uranium, isotopic uranium, gross alpha/beta, gamma spectroscopy, organic compounds, and standard water quality parameters. Our current understanding of the hydrogeologic setting in the vicinity of the Adaya Burial Site is solely based on villager's domestic wells, topographic maps, and satellite imagery. To better understand the hydrogeologic setting, a Groundwater Monitoring Program needs to be developed and should include the installation of twelve groundwater monitoring wells in the vicinity of Tall ar Ragrag and the Adaya Burial Site. Characterization of the limestone aquifer and overlying alluvium is needed. RPC should continue to support health assessments for the villagers in Tall ar Ragrag and Adaya. Collecting samples for surface water (storm water), airborne dust, vegetation, and washway sediment should be conducted on a routine basis. Human access to the Adaya Burial Site needs to be strictly limited. Livestock access on or near the burial site needs to be eliminated. The surface-water exposure pathway is likely a greater threat than the groundwater exposure pathway. Installation of a surface-water diversion or collection system is recommended in order to reduce the potential for humans and livestock to come in contact with contaminated water and sediment. To reduce exposure to villagers, groundwater treatment should be considered if elevated uranium or other contaminants are detected in drinking water. Installing water-treatment systems would likely be quicker to accomplish than remediation and excavation of the Adaya Burial Site. The known potential for human exposure to uranium and metals (such as arsenic, chromium, selenium, and strontium) at the Adaya Burial Site is serious. Additional characterization , mitigation, and remediation efforts should be given a high priority.

54 ENVIRONMENTAL SCIENCES↗

Preliminary SnowSAR Results from SnowEx 2017

SnowEx 2017 was the first in a multi-year series of airborne remote sensing campaigns, designed to address gaps in snow retrieval techniques in preparation for a future snow satellite mission. A variety of sensor types were flown to collect multi-sensor airborne data. In combination with detailed ground truth, this multi-sensor dataset enables critical trade studies to determine optimum sensor-plus-model combinations for different snow conditions and confounding factors. Up to half of terrestrial snow-covered areas are forested, and forests are a major confounding factor for global snow retrievals. Therefore, the main focus of SnowEx 2017 was evaluating the performance of the various sensing techniques to retrieve snow water equivalent (SWE) under steadily increasing amounts of forest cover. The primary site of Grand Mesa, Colorado, USA was selected for its natural gradients of forest density and SWE with a minimum of other factors. Radar retrievals of SWE relying on volume scattering have been studied for three decades, using a variety of frequencies, with varying degrees of success. The most recent volume scattering algorithms have focused on using 2 to 3 frequencies and both co- and cross-polarizations in the 9—18 GHz range (X through Ku bands). As such, one of the primary SnowEx 2017 airborne sensors was a dual-band (X & Ku) radar, the SnowSAR. Earlier versions of SnowSAR were used in 2011 and 2012 campaigns in Finland as well as a 2013 campaign in Canada. For SnowEx 2017, SnowSAR was installed on a P-3 aircraft from the US Naval Research Laboratory. Challenges associated with the aircraft, the installation, schedule, and flying weather all contrived to limit the amount of data collected. However, months of painstaking processing has yielded data that should be of value to the original objectives of SnowEx 2017. This paper will describe in detail the SnowSAR data that were collected, and provide quality assessments of the backscatter coefficient in terms of date, time, location, frequency, polarization, snow conditions, overlap with ground truth sites, forest density, etc. The challenges as well as potential remedies/caveats will be described in order to help guide users and maximize exploitation of this valuable data.

airborne sensors↗

Interpreting forest and grassland biome productivity utilizing nested scales of image resolution and biogeographical analysis

Data acquisition, initial site characterization, image and geographic information methods available, and brief evaluations of first-year for NASA's Thematic Mapper (TM) working group are presented. The TM and other spectral data are examined in order to relate local, intensive ecosystem research findings to estimates of carbon cycling rates over wide geographic regions. The effort is to span environments ranging from dry to moist climates and from good to poor site quality using the TM capability, with and without the inclusion of geographic information system (GIS) data, and thus to interpret the local spatial pattern of factors conditioning biomass or productivity. Twenty-eight TM data sets were acquired, archived, and evaluated. The ERDAS image processing and GIS system were installed on the microcomputer (PC-AT) and its capabilities are being investigated. The TM coverage of seven study areas were exported via ELAS software on the Prime to the ERDAS system. Statistical analysis procedures to be used on the spectral data are being identified.

Iverson, L. R.↗

Programmable Positioner For Spot Welding

Welding station mechanized by installing preset indexing system and gear drive. Mechanism includes a low-cost, versatile, single-axis motion control and motor drive to provide fully-automatic weld sequencing and spot-to-spot spacing. Welding station relieves operator of some difficult, tedious tasks and increases both productivity and quality of welds. Results in welds of higher quality and greater accuracy, fewer weld defects, and faster welding operation.

Roden, William A.↗