International Space Station Active Thermal Control Sub-System On-Orbit Pump Performance and Reliability Using Liquid Ammonia as a Coolant

The International Space Station (ISS) contains two Active Thermal Control Sub-systems (ATCS) that function by using a liquid ammonia cooling system collecting waste heat and rejecting it using radiators. These subsystems consist of a number of heat exchangers, cold plates, radiators, the Pump and Flow Control Subassembly (PFCS), and the Pump Module (PM), all of which are Orbital Replaceable Units (ORU's). The PFCS provides the motive force to circulate the ammonia coolant in the Photovoltaic Thermal Control Subsystem (PVTCS) and has been in operation since December, 2000. The Pump Module (PM) circulates liquid ammonia coolant within the External Active Thermal Control Subsystem (EATCS) cooling the ISS internal coolant (water) loops collecting waste heat and rejecting it through the ISS radiators. These PM loops have been in operation since December, 2006. This paper will discuss the original reliability analysis approach of the PFCS and Pump Module, comparing them against the current operational performance data for the ISS External Thermal Control Loops.

Morton, Richard D.↗

Maturing Pump Technology for EVA Applications in a Collaborative Environment

The transition from low earth orbit Extravehicular Activity (EVA) for construction and maintenance activities to planetary surface EVA on asteroids, moons, and, ultimately, Mars demands a new spacesuit system. NASA's development of that system has resulted in dramatically different pumping requirements from those in the current spacesuit system. Hamilton Sundstrand, Cascon, and NASA are collaborating to develop and mature a pump that will reliably meet those new requirements in space environments and within the design constraints imposed by spacesuit system integration. That collaboration, which began in the NASA purchase of a pump prototype for test evaluation, is now entering a new phase of development. A second generation pump reflecting the lessons learned in NASA's testing of the original prototype will be developed under Hamilton Sundstrand internal research funding and ultimately tested in an integrated Advanced Portable Life Support System (APLSS) in NASA laboratories at the Johnson Space Center. This partnership is providing benefit to both industry and NASA by supplying a custom component for EVA integrated testing at no cost to the government while providing test data for industry that would otherwise be difficult or impossible to duplicate in industry laboratories. This paper discusses the evolving collaborative process, component requirements and design development based on early NASA test experience, component stand alone test results, and near term plans for integrated testing at JSCs.

Hodgson, Edward↗

Passively Q-switched side pumped monolithic ring laser

Disclosed herein are systems and methods for generating a side-pumped passively Q-switched non-planar ring oscillator. The method introduces a laser into a cavity of a crystal, the cavity having a round-trip path formed by a reflection at a dielectrically coated front surface, a first internal reflection at a first side surface of the crystal at a non-orthogonal angle with the front, a second internal reflection at a top surface of the crystal, and a third internal reflection at a second side surface of the crystal at a non-orthogonal angle with the front. The method side pumps the laser at the top or bottom surface with a side pump diode array beam and generates an output laser emanating at a location on the front surface. The design can include additional internal reflections to increase interaction with the side pump. Waste heat may be removed by mounting the crystal to a heatsink.

Li, Steven X.↗

Evaluation of Dry, Rough Vacuum Pumps

This document provides information on the testing and evaluation of thirteen dry rough vacuum pumps of various designs and from various manufacturers. Several types of rough vacuum pumps were evaluated, including scroll, roots, and diaphragm pumps. Tests included long term testing, speed curve generation, voltage variance, vibrations emissions and susceptibility, electromagnetic interference emissions and susceptibility, static leak rate, exhaust restriction, response/recovery time tests, and a contamination analysis for scroll pumps. Parameters were found for operation with helium, which often is not provided from the manufacturer

Hunter, Brian↗

Liquid Rocket Engine with Hybrid Electric Motor Driven Pump

A nuclear thermal rocket with a superconducting electric motor driven boost pump submerged within a tank of liquid hydrogen, where the boost pump is driven by both an electric motor and a turbine. The boost pump can be submerged in liquid hydrogen so that the electric motor operates as a superconducting motor. Also, a turbopump for a rocket engine can include both a turbine and an electric motor to drive the liquid oxidizer and liquid fuel pumps of the turbopump.

Pinera, Alejandro↗

A Comparison of System Architectures for a Mechanically Pumped Two-Phase Thermal Control System

The NASA Jet Propulsion Laboratory is developing a mechanically pumped two-phase fluid loop thermal control system to enable novel mission designs and greater science return. Pumped two-phase fluid loops have the potential to provide robust and effective thermal control that combine the best aspects of passive two-phase systems (heat pipes) and mechanically pumped single-phase fluid loops. The current program requirements include the development of a system with multiple 1 sq.m evaporators, each of which is capable of remaining spatially and temporally isothermal while accommodating heat loads of up to 500 W and local fluxes of up to 5 W/sq.cm. The goal is to attain this using less than 5 W of power. Such a system would be able to accommodate the next generation of payload and bus electronics while using minimal resources. This paper compares two different mechanically pumped two-phase fluid loop architectures in the context of these requirements. A mixed flow and separated flow architecture are compared on a theoretical and experimental basis. Test data from sub-scale, single evaporator/single condenser, mixed flow and separated flow testbeds are presented. In addition, a model is introduced to better understand separated flow systems and some expressions for the theoretical performance limits of such systems are developed. To date, the investigation suggests that a separated flow architecture is better suited to the program requirements. Separated flow systems have the potential to accommodate an isothermalizing two-phase evaporator while using lower levels of power than would be required for a mixed flow system. In addition, it is argued that separated flow systems are more robust and amenable to analysis than mixed flow systems, since they significantly reduce the occurrence of two-phase flow by separating phases in the evaporator. Future work will include developing a full-scale testbed that includes multiple evaporators and condensers in a representative flight configuration.

Furst, Benjamin↗

Thermal Design Challenges Posed by the Four Bed CO2 Scrubber COTS Air-Save Pump

The Four Bed Carbon Dioxide (4BCO2) scrubber Air-Save Pump (ASP) operates as part of the adsorbent bed regeneration cycle. The ASP removes residual air from the bed for return to the cabin prior to heat and vacuum exposure which drives out the CO2 regenerating the bed. 4BCO2 employs a Commercial Off-the-Shelf (COTS) scroll type air pump, repackaged in an acoustically insulated enclosure to reduce noise and mounted to a cold plate. The International Space Station (ISS) Low Temperature Loop (LTL) flow (operating between 38°F and 50°F) first cools the process air, and then flows through the cold plate, cooling the pump. This results in competing ASP thermal design goals: (1) to keep the pump and motor sufficiently cool and (2) to avoid forming condensation due to over-cooling. Surfaces below 60°F typically warrant careful consideration of condensation. A test-calibrated thermal model demonstrates such a balanced design is feasible with temperatures above 60°F. A separate, coupled fluid model predicts the potential for condensation formation, allowing risk assessment of flying with the unmodified design.

Daniel P Popok↗

Propellant Delivery via VDC Driven Pump

The SMART (Scalable Mobile Autonomous Rocket engine Test) testbed system initiative at SSC was conceived to attempt to address many of the principal cost drivers in developing and maintaining a rocket engine test facility. The system (optimized to test engines and components generating up to 10K lbf nominal thrust) is serving as a testbed for innovative technologies and processes to provide lower cost test services with a rapid test cadence and expedient turnaround times. The system can also potentially be used as a testbed to test other related technologies relevant to surface situations (e.g., moon, Mars associated with crogenic fluid management, engine/component testing, autonomous operations, etc.). This FY20 CIF project, being conducted as part of the SMART testbed system, is developing and testing a propellant delivery system via electrically driven centrifugal pumps (obviating dependence upon Multi-Layer Pressure Vessels) with configuration and operation by a minimal number of personnel. During FY20 the team identified the requirements and worked with P3 and Masten Space Systems to develop the long lead (9 months after receipt of order) items, the 400 VDC pumps, for delivery in mid FY21. Since control of the 400 VDC pump motor is not well developed the team has established heuristics to control flows in LN2 at off nominal shaft speeds to allow deep throttling of the pump in flow test scenarios. Various test scenarios including nominal i.e. high flow high pressure, high flow low pressure, low flow high pressure, low flow low pressure, minimum throttle step change, and low inlet pressure cavitation testing were developed ahead of the anticipated hardware delivery and test. FY20 COVID Stage 3 conditions restricted access to the center and hindered lab work, so efforts focused on the system design and testing plans along with the project procurement paperwork for the hardware... now with its anticipated delivery in spring FY21. Some limited access to the center is expected by spring/summer FY21 for the continuing second year (FY21) CIF project effort meant to be focused upon system integration and initial testing.

Aaron Head↗

Tribology Induced Water Pump Bearing Failure

NASA’s In-Space Propulsion facility experienced two infant mortality water pump bearing failures during a recent refurbishment campaign, the cause or causes of which were unclear. A forensic failure study was undertaken that included site visits, collection and examination of physical evidence and a bearing and pump design review. The pumps are large (2000 hp) vertical turbine design machines that utilize metallic sleeve bearings cooled and lubricated by the pumped fluid (water). Though initial possible root cause for the failures were attributed to improper fabrication and debris contamination, detailed examination of failure surfaces combined with bearing design revealed that the failure mode was thermal seizure brought on by inadequate cooling flow. An unusual contributing factor was that the use of grease as an assembly lubricant, as opposed to a fluid like oil, appears to have exacerbated the rather than alleviated the thermal runaway by blocking water flow. Resolution of the problem was achieved through the design and installation of dedicated bearing lubrication water feed system.

bearings↗

Fakir fuel pump

In designing the Fakir fuel pump, the fundamental idea was to obtain a simple and reliable method of conveying the fuel from a low tank to the carburetor, with the avoidance of the faults of all former methods and the simultaneous warming of the fuel by means of the heat of compression generated. The principle of the Fakir fuel pump rests on the well-known principle of the diaphragm pump, which must be suitably adapted to the present purpose.

PUMPS, FUEL↗

Bleed Cycle Propellant Pumping in a Gas-Core Nuclear Rocket Engine System

The performance of ideal and real staged primary propellant pumps and bleed-powered turbines was calculated for gas-core nuclear rocket engines over a range of operating pressures from 500 to 5000 atm. This study showed that for a required engine operating pressure of 1000 atm the pump work was about 0.8 hp/(lb/sec), the specific impulse penalty resulting from the turbine propellant bleed flow as about 10 percent; and the heat required to preheat the propellant was about 7.8 MW/(lb/sec). For a specific impulse above 2400 sec, there is an excess of energy available in the moderator due to the gamma and neutron heating that occurs there. Possible alternative pumping cycles are the Rankine or Brayton cycles.

Gas-core↗

Design of Accumulators and Liquid/Gas Charging of Single Phase Mechanically Pumped Fluid Loop Heat Rejection Systems

For single phase mechanically pumped fluid loops used for thermal control of spacecraft, a gas charged accumulator is typically used to modulate pressures within the loop. This is needed to accommodate changes in the working fluid volume due to changes in the operating temperatures as the spacecraft encounters varying thermal environments during its mission. Overall, the three key requirements on the accumulator to maintain an appropriate pressure range throughout the mission are: accommodation of the volume change of the fluid due to temperature changes, avoidance of pump cavitation and prevention of boiling in the liquid. The sizing and design of such an accumulator requires very careful and accurate accounting of temperature distribution within each element of the working fluid for the entire range of conditions expected, accurate knowledge of volume of each fluid element, assessment of corresponding pressures needed to avoid boiling in the liquid, as well as the pressures needed to avoid cavitation in the pump. The appropriate liquid and accumulator strokes required to accommodate the liquid volume change, as well as the appropriate gas volumes, require proper sizing to ensure that the correct pressure range is maintained during the mission. Additionally, a very careful assessment of the process for charging both the gas side and the liquid side of the accumulator is required to properly position the bellows and pressurize the system to a level commensurate with requirements. To achieve the accurate sizing of the accumulator and the charging of the system, sophisticated EXCEL based spreadsheets were developed to rapidly come up with an accumulator design and the corresponding charging parameters. These spreadsheets have proven to be computationally fast and accurate tools for this purpose. This paper will describe the entire process of designing and charging the system, using a case study of the Mars Science Laboratory (MSL) fluid loops, which is en route to Mars for an August 2012 landing.

HRS↗

Progress Towards Modeling a Rapid Cycle Adsorption Pump for CO2 Compression

A Rapid Cycle Adsorption Pump (RCAP) is a competitive technology for capturing and pressuring CO2 within a Martian In-Situ Resource Utilization (ISRU) system. In an ISRU plant, CO2 from the Martian atmosphere at ~0.69-0.925kPa must first be pressured to ~101-500kPa to produce O2 and/or CH4. A RCAP pressurizes CO2 by imposing fast temperature swings on an adsorbent bed low pressure CO2 is adsorbed onto the cooled bed, and higher pressure CO2 is desorbed from the heated bed. To aid the design of a RCAP for NASA's Advanced Exploration Systems (AES) ISRU project, a finite difference thermal model of a single stack RCAP was developed in Thermal Desktop. The stack consists of one gas passage sandwiched between two sorbent beds and two cold plates (for heating/cooling each bed). The model implements adsorption/desorption physics via a linear driving force approximation in order to predict both temperature and pressure swings in the pump. The modeling approach is presented along with a discussion of its results and the current design. The model was also used to trade cooling speed when constructing the RCAP with 3D printed high thermal conductivity copper (GRCop-84) verses 3D printed aluminum (AlSi10mg). A wide assembly was modeled to predict the performance of multiple stacks in parallel. Major performance drivers were identified to be 1) the contact heat transfer to the sorbent bed, and 2) the pump's thermal mass.

Modeling↗

Integrated Pump Assembly - An Active Cooling System for Mars Pathfinder Thermal Control

The Mars Pathfinder spacecraft which will be launched in December 1996 features an active cooling system for controlling the temperature of the spacecraft. This will be the first time that such a mechanical pump cooling system is used on an interplanetary or long duration flight (over two weeks) in space. The major element of the cooling system is the Integrated Pump Assembly (IPA). It uses centrifugal pumps to circulate liquid Freon to transfer heat from spacecraft electronics to an external radiator. This paper describes the design, fabrication, assembly, and testing of the IPA.

cooling↗

Mechanical Pumped Cooling Loop for Spacecraft Thermal Control

The Mars Pathfinder (MPF) spacecraft, scheduled for a December '96 launch to Mars, uses a mechanically pumped loop to transfer dissipated heat from the insulated lander electronics to an external radiator. This paper discusses the tradeoffs performed before choosing a mechanically pumped loop as the thermal control system for MPF. It describes the analysis, design, and predicted performance of this system. The various development tests performed are discussed along with the current status of this cooling system. Finally, some thoughts on the development of mechanically pumped loops for future spacecraft are presented.

Mars↗

(abstract) Mars Pathfinder Active Thermal Control System: Ground and Flight Performance of a Mechanically Pumped Cooling Loop

A key element of the Mars Pathfinder thermal control system is the Heat Rejection System (HRS). The HRS of Mars Pathfinder is designed to actively control the temperatures of the various parts of the spacecraft.This is achieved by mechanically circulating single-phase Freon 11 liquid through the lander and cruise electronics box heat exchangers and transferring the heat to an external radiator on the cruise stage. This is the first time in spacecraft history that a mechanically pumped cooling loop has been used on a long duration spacecraft mission. Many lessons have been learned during the testing and ground and flight operation of the HRS. This paper will present the performance of the mechanically pumped cooling loop during the ground and flight operations. Based on the lessons learned from this experience, recommendations on the design and operation of the pumped cooling loops for future space missions will be made.

Mars↗

Experimental Results of a Rapidly Cycled Temperature Swing Adsorption Pump in a Terrestrial Environment

To improve the increasing CO 2 levels on Earth, technology for carbon capture and utilization must be efficient and cost effective. One major contributor of atmospheric CO 2 is post-combustion flue gas, which can contain up to 20% CO 2 . Scrubbing this CO 2 could reduce the environmental impact of this common industrial process. In off-Earth environments, capturing and utilizing CO 2 from space resources is useful for crewed spaceflight life support. Specifically, the Bosch process, which produces water and carbon powder by reacting CO 2 and hydrogen, is a possible in-situ resource utilization (ISRU) architecture for the Moon and Mars. The Rapid Cycle Temperature Swing Adsorption (RC-TSA) pump is an innovative technology designed to capture CO 2 efficiently. The RC-TSA leverages a stacked plate geometry to cycle multiple zeolite-coated beds. The thin layers allow for rapid heat transfer of the zeolite coating, which improves performance over previously tested pump designs. The design is favorable for scalability and manufacturability, which are forward work. Initial testing of the sorption pump using a simulated flue gas environment shows favorable breakthrough capacities and reduced cycle times. Results show promise for on- and off-Earth applications, such as a Martian surface and crewed spaceflight environments.