Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “propane”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Elucidating the Competitive Hydrodeoxygenation of Lignin-Derived Oxygenates over Bulk MoO 3 Catalyst through Kinetic Analysis

Ambient pressure hydrodeoxygenation (HDO) of lignin-derived oxygenates over molybdenum oxide-based catalysts is an effective strategy to produce chemicals that can be directly integrated into our existing petrochemical infrastructure. Complexities pertaining to the simultaneous kinetic and mechanistic analysis of HDO have limited research endeavors to single-compound systems. Although valuable insight into the catalytic reaction has been gained through this approach, it provides limited understanding of the competitive adsorption behavior manifest in a realistic multioxygenate reaction environment. To address this shortcoming, simultaneous gas-phase acetone and anisole HDO was performed at 330 °C and ≤1 bar H 2 partial pressure over bulk MoO 3 . Propene, propane, and benzene were the HDO products formed, showing a similar product distribution to the single-compound system. Selectivity to propene and propane was ∼14 times higher than benzene, even at three times higher anisole partial pressure compared to acetone. A negative anisole HDO (−0.97 ± 0.22) rate order with varying acetone partial pressure suggested a strong inhibition effect on anisole HDO by acetone. Conversely, with increasing anisole partial pressure, a rate order of −0.07 ± 0.12 was observed for acetone HDO, implying a weak impact of anisole cofeed on acetone HDO. A kinetic-driven approach was taken to estimate the relative adsorption constants of the oxygenates. Acetone exhibited a 6.4 times higher adsorption propensity on the HDO active site than anisole. Relative adsorption constants for phenolics increased with increasing basicity of the oxygenate but decreased for aliphatic molecules, suggesting a volcano-shaped relationship. The results suggest the possibility of an optimal electron density around the molecule’s oxygen atom to maximize the molecule’s adsorption strength.

acid sites↗

Acid Catalysis over Low-Silica Faujasite Zeolites

We report low-silica faujasite (FAU) zeolites (with Si/Al ratio of ca. 1.2–1.8) sustain framework integrity and porosity upon moderate ion exchange (0.01 M NH 4 NO 3 solution for 1 h at ambient temperature), which introduces two kinds of protons, distinctive in reactivity and coordination to the zeolite framework, within supercages (H SUP ). Moderate ion exchange limited within supercages transpires while maintaining full occupancy of Na + cations within associated sodalite cages; this in turn helps stabilize the framework of low-silica H-FAU zeolites. Protons located on site II (H 3630 ) and site III (H 3650 ) within supercages on low-silica FAU zeolites can be classified and enumerated by virtue of infrared spectroscopy, providing an opportunity to compare reactivities of these distinct protons for monomolecular protolytic reactions of propane. Protons on site II exhibit prominently higher reactivity for monomolecular propane dehydrogenation and cracking than protons on site III. Low-silica proton-form FAU zeolites (zeolite X) upon moderate ion exchange possess protons on site III that are unavailable on high-silica FAU zeolites (zeolite Y) and limit ion exchange within supercages, providing unprecedented high-temperature structural and chemical stability (>773 K) and enabling their application as solid-acid catalysts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transition-state correlations for predicting thermochemistry of adsorbates and surface reactions

Estimating thermochemical properties from linear correlations may provide a pathway to circumvent expensive density functional theory (DFT) calculations for quantities such as pre-exponentials and temperature corrections to DFT energies. Here, in this work, we construct thermochemical scaling relations between C 1 –C 6 n-alkanes in the gas phase and adsorbed alkyl chains extending from several transition metal surfaces, and examine changes in the slope and fit between metals and adsorption sites. We subsequently add –OH, –NH 2 , C$=$O, and C$=$C functional groups to the C 1 –C 6 molecules and demonstrate strong linear correlations for thermochemistry across all species. We broaden the correlations to incorporate transition states of C 1 –C 6 n-alkane dehydrogenation reactions, where thermochemistry for computationally prohibitive transition-state calculations can be quickly assessed. Additionally, we rationalize the linearity of thermochemical correlations based on the composition of the homologous series and theoretical assessments. As an application of the correlations, we estimate pre-exponentials for elementary surface reactions of ethane and propane hydrogenolysis on Ru(0001), which is of relevance to plastic hydrogenolysis. Depending on kinetically important steps, entropic contributions may be necessary to include in certain reaction mechanisms; in contrasting examples, entropies are found to be relatively insignificant for ethane hydrogenolysis but pertinent for propane hydrogenolysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Machine learning using host/guest energy histograms to predict adsorption in metal–organic frameworks: Application to short alkanes and Xe/Kr mixtures

A machine learning (ML) methodology that uses a histogram of interaction energies has been applied to predict gas adsorption in metal–organic frameworks (MOFs) using results from atomistic grand canonical Monte Carlo (GCMC) simulations as training and test data. In this work, the method is first extended to binary mixtures of spherical species, in particular, Xe and Kr. In addition, it is shown that single-component adsorption of ethane and propane can be predicted in good agreement with GCMC simulation using a histogram of the adsorption energies felt by a methyl probe in conjunction with the random forest ML method. Here, the results for propane can be improved by including a small number of MOF textural properties as descriptors. We also discuss the most significant features, which provides physical insight into the most beneficial adsorption energy sites for a given application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transient mixing behavior of a supercritical fluid injected into supercritical and subcritical environments

Transient, near-field mixing of a supercritical fluid injected into supercritical and subcritical environments is investigated experimentally. Fuel (propane) from a 100 μm diameter Bosch diesel injector is injected into a high-pressure test rig with a steady flow of heated, low-velocity nitrogen to control the ambient pressure and temperature. The fuel supply pressure is approximately 190 bar, allowing short injections lasting 3–4 ms to be performed in quick succession to acquire statistically significant datasets to represent the unsteady fuel–air mixing. Two test cases with the same ambient density and injector inlet pressure and temperature were chosen in an attempt to isolate effects of mixture phase behavior. Microscopic rainbow Schlieren deflectometry (RSD) is used for visualization and quantitative data acquisition. In the case of the supercritical ambient, the injector inlet and exit and ambient conditions are all supercritical. The RSD analysis reveals a mixing process similar to the single phase fluid mixing, though condensation is also observed locally, and can be explained by the adiabatic mixing theory presented in the paper. For the subcritical ambient case, the injector inlet is supercritical, but the injector exit and ambient conditions are both subcritical. The results show a rapid expansion in the near-field promoting mixing between propane and nitrogen. At downstream locations, significant condensation is also observed as predicted by the adiabatic mixing theory. As a result, the supercritical ambient case exhibited longer and narrower jet penetration compared to the subcritical ambient case.

02 PETROLEUM↗

Zeolitic Imidazolate Framework Membranes: Novel Synthesis Methods and Progress Toward Industrial Use

In the last decade, zeolitic imidazolate frameworks (ZIFs) have been studied extensively for their potential as selective separation membranes. In this review, we highlight unique structural properties of ZIFs that allow them to achieve certain important separations, like that of propylene from propane, and summarize the state of the art in ZIF thin-film deposition on porous substrates and their modification by postsynthesis treatments. We also review the reported membrane performance for representative membrane synthesis approaches and attempt to rank the synthesis methods with respect to potential for scalability. To compare the dependence of membrane performance on membrane synthesis methods and operating conditions, we map out fluxes and separation factors of selected ZIF-8 membranes for propylene/propane separation. Finally, we provide future directions considering the importance of further improvements in scalability, cost effectiveness, and stable performance under industrially relevant conditions.

Chemistry↗

Chemically Amplified, Dry-Develop Poly(aldehyde) Photoresist

The catalytic decomposition of poly(phthalaldehyde) with a photoacid generator can be used as dry-develop photoresist, where the exposed film depolymerizes into small molecules to allow the development of features via controlled vaporization. Higher temperatures enabled shorter dry-development times, but also promoted faster photoacid diffusion that compromised pattern fidelity. Trihexylamine was used as a base quencher to counteract acid diffusion in a phthalaldehyde-propanal co-polymer photoresist. The propanal co-monomer in the polymer improves the vaporization rate because it has a higher vapor pressure than phthalaldehyde. Addition of the base quencher was found to improve the contrast, pattern fidelity, and ease-of-handling of the dry-develop resist in a direct-write UV lithography tool. The dry-development of 4 μ m features was achieved with no appreciable residue. For large area features, a spatially variable exposure method was used to direct the residue away from the exposed area. The gradient exposure method was used to produce 100 μ m features. Plasma etching after dry-development was also used to achieve residue-free dry-developed patterns. These results show the benefits of incorporating base additives into a dry-develop depolymerizable resist system and highlight the need for addressing residue formation.

Materials Science↗

Hydrogen Plus Other Alternative Fuels Risk Assessment Models (HyRAM+) (Technical Reference Manual V.4)

The HyRAM+ software toolkit provides a basis for conducting quantitative risk assessment and consequence modeling for hydrogen, methane, and propane infrastructure and transportation systems. HyRAM+ is designed to facilitate the use of state-of-the-art science and engineering models to conduct robust, repeatable assessments of safety, hazards, and risk. HyRAM+ includes generic probabilities for equipment failures, probabilistic models for the impact of heat flux on humans and structures, and experimentally validated first-order models of release and flame physics. HyRAM+ integrates deterministic and probabilistic models for quantifying accident scenarios, predicting physical effects, and characterizing hazards (thermal effects from jet fires, overpressure effects from delayed ignition), and assessing impact on people and structures. HyRAM+ is developed at Sandia National Laboratories to support the development and revision of national and international codes and standards. HyRAM+ is a research software in active development and thus the models and data may change. This report will be updated at appropriate developmental intervals. This document provides a description of the methodology and models contained in HyRAM+ version 4.0. The most significant change for HyRAM+ version 4.0 from HyRAM version 3.1 is the incorporation of other alternative fuels, namely methane (as a proxy for natural gas) and propane into the toolkit. This change necessitated significant changes to the installable graphical user interface as well as changes to the back-end Python models. A second major change is the inclusion of physics models for the overpressure associated with the delayed ignition of an unconfined jet/plume of flammable gas.

02 PETROLEUM↗

Hydrogen Plus Other Alternative Fuels Risk Assessment Models (HyRAM+) Version 5.0 Technical Reference Manual

The HyRAM+ software toolkit provides a basis for conducting quantitative risk assessment and consequence modeling for hydrogen, natural gas, and autogas systems. HyRAM+ is designed to facilitate the use of state-of-the-art models to conduct robust, repeatable assessments of safety, hazards, and risk. HyRAM+ integrates deterministic and probabilistic models for quantifying leak sizes and rates, predicting physical effects, characterizing hazards (thermal effects from jet fires, overpressure effects from delayed ignition), and assessing impacts on people. HyRAM+ is developed at Sandia National Laboratories to support the development and revision of national and international codes and standards, and to provide developed models in a publicly-accessible toolkit usable by all stakeholders. This document provides a description of the methodology and models contained in HyRAM+ version 5.0. The most significant change for HyRAM+ version 5.0 from HyRAM+ version 4.1 is the ability to model blends of different fuels. HyRAM+ was previously only suitable for use with hydrogen, methane, or propane, with users having the ability to use methane as a proxy for natural gas and propane as a proxy for autogas/liquefied petroleum gas. In version 5.0, real natural gas or autogas compositions can be modeled as the fuel, or even blends of natural gas with hydrogen. These blends can be used in the standalone physics models, but not yet in the quantitative risk assessment mode of HyRAM+.

03 NATURAL GAS↗

Operational Energy Life Cycle Data Development for the National Institute of Standards And Technology (NIST) Building Industry Reporting and Design for Sustainability (BIRDS) Neutral Environmental Software Tool (NEST)

For this analysis, regionalized life cycle assessment (LCA) results for environmental impacts (using the Tool for Reduction and Assessment of Chemicals and Other Environmental Impacts [TRACI] 2.1) and cumulative energy demand (using the Federal Life Cycle Analysis Commons Elementary Flow List [FEDEFL] Inventory Methods v1.0.0) were evaluated for the production and utilization of electricity, natural gas, fuel oil, and propane as commodities within residential and commercial buildings. These results can used as a framework for future research into net zero, high-performance buildings, such as done here for the Building Industry Reporting and Design for Sustainability (BIRDS) database by the National Institute of Standards and Technology (NIST) Engineering Laboratory. The geographical results were assigned to each United States (U.S.) Zone Improvement Plan (ZIP) code based on the ZIP code location and corresponding Balancing Authority Area, natural gas basin, and Petroleum Administration for Defense Districts (PADDs). Additionally, previously developed models were utilized to develop future life cycle profiles. Projections were based on data available from the U.S. Energy Information Administration Annual Energy Outlook 2022 through 2050 (AEO 2022). Electricity LCA models were updated based on AEO 2022 projected annual generation mixes, while the natural gas baseline model was updated based on projected shares of natural gas types (conventional, shale, tight, and coalbed methane). Projections of crude oil production rates and export rates were applied to the petroleum baseline model in five-year increments to investigate their effects on the life cycle profile of fuel oil and propane. While only 100-year Global Warming Potential (GWP-100) with climate carbon feedback (CC-FB) and Cumulative Energy Demand are shown in Section 4: Results, the complete results, including Acidification Potential, Eutrophication Potential, Freshwater Ecotoxicity Potential, GWP-100 without inclusion of CC-FB, Human Health Impacts Potentials (Cancer, Non-Cancer), Ozone Depletion Potential, Particulate Matter Formation Potential, and Photochemical Smog Formation Potential, are tabulated for each ZIP code in the Excel worksheets that accompany this analysis. For the Excel spreadsheet tools associated with this report, please go to https://www.netl.doe.gov/energy-analysis/details?id=f8890fac-be55-44ac-aaa9-e2888bfabe93

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single heating, ventilation, and air-conditioning (HVAC) end-use savings shape measure - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation. This measure replaces existing multi-zone variable air volume (VAV) systems or single-zone rooftop units (RTU) with a VRF HR system coupled with a DOAS that includes an energy/heat recovery ventilator (E/HRV). The measure covers 53% of exisiting building stock's floor area and is not applicable to HVAC system types using district heating or cooling or buildings/spaces that include high-ventilation spaces such as kitchens where the amount of exhaust air is large. A DOAS with E/HRV is used to provide required outdoor ventilation air to spaces since ventilation air is generally not supplied by a VRF HR system. An exhaust air energy recovery ventilator (ERV ) with sensible and latent heat exchange is added to humid climate zones while a heat recovery ventilator (HRV ) with sensible only exchange is added to drier climate zones. The ERV is modeled as a fixed membrane plate counterflow heat exchanger, while the HRV is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and minimum exhaust temperature control for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: LED Lighting

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a timeseries profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - LED lighting. The LED lighting measure replaces interior lights with LEDs where applicable. The measure resulted in 1.25 TBtu energy savings across the building stock, with the majority of savings occurring in retail and warehouse buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Economizers

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Boiler Replacement with Air-Source Heat Pump Boiler and Electric Boiler Backup

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock TM and ComStock TM models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure—boiler replacement by air-source heat pump boiler. This measure replaces space heating natural gas boilers by air-source heat pump boilers when applicable and helps quantify the decarbonization as well as the energy savings potential from the replacement. The measure resulted higher savings in natural gas consumption compared to the increase in electricity consumption, with a ratio of 2.9. The total natural gas energy consumption was reduced by 20%, whereas the total electricity consumption was increased by 2.5%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Boiler Replacement with Air-Source Heat Pump Boiler and Natural Gas Boiler Backup

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock (™) and ComStock (™) models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - boiler replacement with air-source heat pump boiler with natural gas boiler backup. This measure replaces natural gas boilers for HVAC application by air-source heat pump boilers when applicable and use natural gas boiler backup when the heat pump boiler could not operate due to outdoor air conditions which are below its cutoff temperature. This measure helps to quantify the decarbonization as well as the energy savings potential from the replacement. The measure resulted higher savings in natural gas consumption compared to the increase in electricity consumption, with a ratio of 3. The total natural gas energy consumption was reduced by 41%, whereas the total electricity consumption was increased by 5.3%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Console Water-to-Air Geothermal Heat Pump

Executive Summary Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models over the past several years, the objective of this work is to produce national datasets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover most of the high-impact, market-ready (or nearly market-ready) measures. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. This measure models the conversion of an existing heating, ventilating, and air-conditioning (HVAC) system to a series of “console” water-to-air heat pumps served by a ground heat exchanger. Console water-to-air geothermal heat pumps (GHP) are all-in-one packages that have no or minimal ductwork and serve individual spaces. Properly designed ground heat exchanger-coupled systems can offer benefits in energy efficiency relative to “conventional” HVAC systems, as well as facilitating beneficial electrification. Console GHPs can be coupled to a ground loop on the source side and can directly replace electric baseboard heaters or air-source packaged terminal heat pumps. Console GHPs can also bring in outdoor air for ventilation. This measure will be referred to throughout the document as the “Console GHP” upgrade.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar Energy Extension Project

The town of Stratford plans to develop and own a 6 kilowatt (kW) solar array on the roof of a municipal-owned public pavilion on the town green. A SolarEdge level 2 EV charging station will be installed at the pavilion to be used by the public. The charging station will have one charging port. The town will install 3 air source heat pumps in the library located adjacent to the pavilion to reduce the use of propane to heat the library. The town will install 4 air source heat pumps in the Town Hall to reduce the use of #2 heating oil to heat the facility. The 6 kW solar array will provide electricity to the library to offset electricity usage, and when an EV plugs into the charging station the solar will provide electricity to the charging station. There is no ground disturbance or ground trenching associated with this project. The 6 kW solar array on the roof of the pavilion will include 20 (390) watt all black panels. A SolarEdge level 2 EV charger will be installed at the pavilion with the 240 V inverter. The solar array will provide electricity to the library and when a vehicle plugs into the EV charger the solar array will switch to power the charger. Any excess electricity that is generated by the array and not used by the library or the EV charger will be fed onto the grid and the town will receive a net metering credit applied towards future consumption. There is no ground disturbance associated with the EV charger or solar array, and the town will install signage to direct the public to the charger. The library will install 2 (18,000) BTU ductless air source heat pumps and 1 (24,000) BTU unit. This will significantly reduce the amount of propane required to heat the library. The Town Hall will install 2 (36,000) BTU ductless air source heat pumps and 2 (9,000) BTU units to reduce the amount of #2 heating oil required to heat the building.

14 SOLAR ENERGY↗

UT-GOM2-2 Preliminary Report: Terrebonne Basin Northern Gulf of Mexico, 30 July-28 September 2023

In the summer and fall of 2023, the Gulf of Mexico Deepwater Hydrate Coring Expedition (UT-GOM2-2) drilled, cored, made downhole measurements, and analyzed samples from the seafloor to the base of the gas hydrate stability zone in one location (Site H, WR313) in the Terrebonne basin, deepwater Gulf of Mexico. Analyses of data and samples from the expedition will inform biological, geochemical, and geomechanical models to constrain the role of gas hydrates in the carbon cycle and the potential for gas hydrates as an energy resource. Pressure and conventional cores were collected continuously to a depth of 155.1 meters below the seafloor (mbsf). At deeper depths, cores were taken periodically from hydrate-bearing sands and their bounding muds to a total depth of 861.3 mbsf. 162.6 m of conventional core and 54.8 m of pressure core were obtained. Twelve temperature measurements were made between 27.1 and 144.5 mbsf to determine the geothermal gradient. At the seafloor, more than 4 m of sandy silt of unknown origin was encountered. Beneath this sand, to a depth of ~200 mbsf, the section was composed of interbedded mud and biogenic carbonate ooze. The biogenic ooze correlated to low density and high porosity intervals observed in the previously acquired logging while drilling (LWD) data and as measured. Calcareous nannofossil biostratigraphy constrains the entire record to the Pleistocene (< 0.91 million years) with a pronounced increase in sedimentation rate with depth. Beneath 200 mbsf, the section was predominantly composed of mud with two thicker, hydrate-bearing coarse-grained intervals, which are commonly known as the Blue and Orange sands. The dissolved gas concentration was quantified from pressure cores. In the shallow section, dissolved methane concentration increased below the sulfate-methane transition zone (SMTZ) and reaches saturation (the limit of solubility for methane) at 147 mbsf. Gas expansion was very common in conventional and depressurized pressure (conventionalized) cores below the SMTZ. At deeper depths, the methane concentration within muds bounding the Blue and Orange reservoirs was generally found to be less than saturation. The dissolved and hydrate gas composition is consistent with a microbial source, containing greater than 99.99% methane and only trace concentrations of ethane, propane, and butane. The methane to ethane ratio (C 1 /C 2 ) and the methane to ethane plus propane (C 1 /(C 2 +C 3 )) decrease with depth down to at least 678 mbsf, mainly driven by the increase in ethane with depth. It is unclear if this trend continues through the Orange sand interval. The δ 13 C isotopic signature of methane ranges between -69.9 and -78.5 ‰ Vienna Pee Dee Belemnite (VPDB). Pressure core recovery of all sandy intervals was poor. However, pressure core logs of the Orange sand show intervals of low density and high velocity, which are indicative of high hydrate saturation. One core from within the Orange sand was composed of interbedded graded sandy silt and mud. The sandy silts from this core are composed of mainly quartz and feldspar with some lithics. Most of the recovered pressure core samples are maintained at near in-situ pressure and temperature (within the hydrate stability field) at the University of Texas Pressure Core Center awaiting analysis. In the shallow section, samples will be used to determine the flux of organic carbon through the basin system, find the rate at which that carbon was consumed, and understand the microbial population responsible for these processes. In the deeper section, samples from in and around the hydrate reservoirs will be used to determine the petrophysical properties of the reservoir and bounding seals in these systems.

03 NATURAL GAS↗