Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “power distribution network”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Companion Assisted Software Based Remote Attestation in SCADA Networks

Critical infrastructure such as power generation and water distribution systems have become a priority target in cyber warfare because of their recent computerization and introduction to the internet. As a result, Supervisory Control and Data Acquisition (SCADA) system security has become a hot topic in academic and industrial research. Among these topics, Remote Attestation is a security method intended to detect the presence of fileless malware in remote devices as they continue to operate. This allows for the detection of malware in the absence of long-term storage artifacts before symptoms of compromise begin to appear. In general, a trusted device (the verifier) makes a request for evidence of innocence from the untrusted device (the prover). In software-based schemes, the verifier can then measure the delay between its request and the prover’s response. If this delay is greater than the known computational time of the evidence gathering algorithm performed by the prover, then evidence may have been forged. Multi-hop networks often introduce too much network jitter to allow accurate measurement of prover response time, which limits the effectiveness of software based Remote Attestation in a real-world setting. In this work, we introduce a companion device that the verifier can trust to perform a subset of attestation, thereby removing any network jitter. This device is a Field Programmable Gate Array (FPGA) that is physically connected to the prover. We provide a communication protocol between the verifier, prover, and companion. To evaluate our scheme, we simulate it in a common SCADA network environment under normal and heavy traffic loads. Our simulations are performed in the discrete event network simulator NS-3, and we perform statistical analysis over our results to show that our scheme allows for tight timing constraints to be placed on the prover such that the verifier can more easily determine the validity of the evidence that it receives.

Johnson, William A.↗

SuperLab 2.0 Showcase: Connecting Five Labs to Tackle Grid Complexity and Unlock Unique Grid Asset Potential

SuperLab 2.0 (5-Lab Demo) is a collaborative, national-scale experiment showcasing the coordination of geographically distributed energy assets in real time. The demonstration integrates 25 physical and digital assets, spanning wind, PV, batteries, electrolyzers, DC fast chargers, microgrid controllers, building automation systems, small modular reactor (SMR), control centers, and gas turbines, across five DOE national laboratories-NLR, INL, NETL, LBNL, and SNL. These assets are unified using Energy Sciences Network (ESnet), a low-latency, high-performance U.S. Department of Energy's (DOE) network, and controlled via a centralized energy controller hosted at NLR's ARIES facility. The demonstration validates the ability to stress-test hybrid energy systems under dynamic scenarios to de-risk advanced control strategies for greater resilience and flexibility. SuperLab 2.0 (5-Lab Demo) showcased a major advancement in federated national laboratory collaboration, enabling real-time, cross-laboratory experimentation to coordinate geographically dispersed distributed energy resources (DERs) using various communication protocols and networks. SuperLab 2.0 (5-Lab Demo) built on previous demonstrations conducted between NLR-PNNL and NLR-INL connecting diverse assets including distant protection devices, a SMR simulator, and a high temperature electrolyzer (HTE). Previous demos were based on a single connection between two labs with minimal coordination challenges. The 5-Lab demo with a centralized controller, distributed testbeds across different geographical locations, and use of protocols-based communication represents a scenario closer to real-world grid operations that coordinate resources across a region to meet system needs. This experiment studied how local DER controllers interact with a centralized energy controller during normal and abnormal events to maintain reliability. The SuperLab team across the five labs implemented a notional power system model equivalent of transmission and distribution lines, represented by the data networks interconnecting the labs. Each lab continuously exchanged local parameters (such as P and Q) from its Hardware-In-Loop (CHIL) and Power Hardware-In-Loop (PHIL) assets through centralized energy controller at NLR, enabling real-time interaction and coordination across sites. By leveraging ESnet as the communication backbone, the team successfully operated the distributed assets as a unified power system, with each bus represented by a different laboratory. This setup mirrors how assets interact in real-world power systems across dispersed locations with various protocols and latencies. At each lab site, assets were operated using their own local controllers which were coordinated through an overarching operation and control layer of centralized energy controller, equivalent to how an energy management system (EMS) orchestrates assets across a regional or national grid. SuperLab's federated connectivity utilized a Digital Real-Time Simulators (DRTS)-type gateway to connect Controller Hardware-In-Loop (CHIL) and PHIL assets between labs. To enable this federated connection through ESnet, a deterministic network was established where latency variations were consistent. This consistency allowed the development of digital filters for the power system assets across CHIL and PHIL interfaces to avoid unstable and unreliable grid conditions. This report provides an overview of the cross-laboratory configuration and offers insights into interconnecting geographically distributed research assets to test them as if they were co-located. This experiment represents a step toward linking nine DOE national laboratories, enabling nation-wide simulations that can address utility-driven challenges with grid resilience, flexibility, and modernization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A computational-grid based system for continental drainage network extraction using SRTM digital elevation models

We describe a new effort for the computation of elevation derivatives using the Shuttle Radar Topography Mission (SRTM) results. Jet Propulsion Laboratory's (JPL) SRTM has produced a near global database of highly accurate elevation data. The scope of this database enables computing precise stream drainage maps and other derivatives on Continental scales. We describe a computing architecture for this computationally very complex task based on NASA's Information Power Grid (IPG), a distributed high performance computing network based on the GLOBUS infrastructure. The SRTM data characteristics and unique problems they present are discussed. A new algorithm for organizing the conventional extraction algorithms [1] into a cooperating parallel grid is presented as an essential component to adapt to the IPG computing structure. Preliminary results are presented for a Southern California test area, established for comparing SRTM and its results against those produced using the USGS National Elevation Data (NED) model.

stream extraction↗

Voltage profile program for the Kennedy Space Center electric power distribution system

The Kennedy Space Center voltage profile program computes voltages at all busses greater than 1 Kv in the network under various conditions of load. The computation is based upon power flow principles and utilizes a Newton-Raphson iterative load flow algorithm. Power flow conditions throughout the network are also provided. The computer program is designed for both steady state and transient operation. In the steady state mode, automatic tap changing of primary distribution transformers is incorporated. Under transient conditions, such as motor starts etc., it is assumed that tap changing is not accomplished so that transformer secondary voltage is allowed to sag.

Source record↗

Solar Dynamic Power System Stability Analysis and Control

The objective of this research is to conduct dynamic analysis, control design, and control performance test of solar power system. Solar power system consists of generation system and distribution network system. A bench mark system is used in this research, which includes a generator with excitation system and governor, an ac/dc converter, six DDCU's and forty-eight loads. A detailed model is used for modeling generator. Excitation system is represented by a third order model. DDCU is represented by a seventh order system. The load is modeled by the combination of constant power and constant impedance. Eigen-analysis and eigen-sensitivity analysis are used for system dynamic analysis. The effects of excitation system, governor, ac/dc converter control, and the type of load on system stability are discussed. In order to improve system transient stability, nonlinear ac/dc converter control is introduced. The direct linearization method is used for control design. The dynamic analysis results show that these controls affect system stability in different ways. The parameter coordination of controllers are recommended based on the dynamic analysis. It is concluded from the present studies that system stability is improved by the coordination of control parameters and the nonlinear ac/dc converter control stabilize system oscillation caused by the load change and system fault efficiently.

Momoh, James A.↗

The Use of Software Agents for Autonomous Control of a DC Space Power System

In order to enable manned deep-space missions, the spacecraft must be controlled autonomously using on-board algorithms. A control architecture is proposed to enable this autonomous operation for an spacecraft electric power system and then implemented using a highly distributed network of software agents. These agents collaborate and compete with each other in order to implement each of the control functions. A subset of this control architecture is tested against a steadystate power system simulation and found to be able to solve a constrained optimization problem with competing objectives using only local information.

autonomous control↗

Optimal Demand Response Incorporating Distribution LMP with PV Generation Uncertainty

The utilization of aggregated demand-side flexibility via demand response (DR) has become a promising pathway for the integration of renewable energy resources in power systems. Nowadays, there are several management strategies for DR such as the price-based transactive control strategies. However, many of such existing price-based control strategies neglect the physics and operational constraints of the underlying distribution networks when computing the price, raising concerns regarding their theoretical and practical values. This paper studies this issue and investigates optimal DR (ODR) by incorporating the distribution locational marginal price (DLMP). In particular, we discuss DR in connection with DLMPs and propose a multiperiod bilevel optimization problem to find the ODR strategy. Here, the objective is to minimize the peak load, load fluctuation, and payments of load aggregators. In addition, a robust bilevel ODR model is formulated to provide a robust ODR strategy while minimizing operating costs under the worst-case realization of uncertainties; this mitigates the impact of forecasting errors on renewable energy resources. Then, we propose an efficient solution approach by employing the Karush-Kuhn-Tucker conditions and strong duality. Simulation results are presented to illustrate the mutual impacts of the interaction between DR and DLMP and the benefits of the robust ODR strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Topological Machine Learning Methods for Power System Responses to Contingencies

While deep learning tools, coupled with the emerging machinery of topological data analysis, are proven to deliver various performance gains in a broad range of applications, from image classification to biosurveillance to blockchain fraud detection, their utility in areas of high societal importance such as power system modeling and, particularly, resilience quantification in the energy sector yet remains untapped. To provide fast acting synthetic regulation and contingency reserve services to the grid while having minimal disruptions on customer quality of service, we propose a new topology-based system that depends on a neural network architecture for impact metric classification and prediction in power systems. This novel topology-based system allows one to evaluate the impact of three power system contingency types, in conjunction with transmission lines, transformers, and transmission lines combined with transformers. We show that the proposed new neural network architecture equipped with local topological measures facilitates more accurate classification of unserved load as well as the amount of unserved load. In addition, we are able to learn more about the complex relationships between electrical properties and local topological measurements on their simulated response to contingencies for the NREL-SIIP power system.

contingency analysis↗

Stirling Power Conversion for Lunar Applications

NASA is developing Stirling power convertors for use in nuclear power systems that would provide electricity to users on the lunar surface. NASA’s Radioisotope Power Systems (RPS) Program is maturing advanced dynamic convertor technologies that would increase the efficiency beyond the heritage systems for missions to the Moon and other solar system bodies of interest. Development efforts have focus on Stirling and Brayton designs that meet reliability and robustness requirements for operation in the lunar environment. GRC is also maturing low power convertors in the range of 1-40 watts to power micro-spacecraft or a network of distributed probes and include basic demonstration of in-house designs for convertors and controllers. In addition to RPS applications, conceptual fission systems have been demonstrated using Stirling convertors in multiple electrically heated tests and one test heated by a nuclear reactor. The Stirling convertors used in these fission system concepts include 100 We convertors to enable a 1 kWe system, 1 kWe convertors to enable a 10 kWe system, and 6 kWe convertors to enable a 40 kWe system. The maturation of Stirling power convertors for nuclear applications includes verification of performance in relevant environments and validation of the design with a focus on high reliability and robustness. Over 1 million hours of testing has been accumulated on dozens of convertors since 1999 in the Stirling Research Laboratory at the NASA Glenn Research Center located in Cleveland Ohio, where the longest running convertor is the work record holder at 137,000 hours, or 15.5 years. These maturation efforts have been instrumental in increasing the technology readiness level of Stirling technologies for space applications.

S. Wilson↗

Simulation test beds for the space station electrical power system

NASA Lewis Research Center and its prime contractor are responsible for developing the electrical power system on the space station. The power system will be controlled by a network of distributed processors. Control software will be verified, validated, and tested in hardware and software test beds. Current plans for the software test bed involve using real time and nonreal time simulations of the power system. This paper will discuss the general simulation objectives and configurations, control architecture, interfaces between simulator and controls, types of tests, and facility configurations.

Sadler, Gerald G.↗

Simulation test beds for the Space Station electrical power system

NASA Lewis Research Center and its prime contractor are respnsible for developing the electrical power system on the Space Station. The power system will be controlled by a network of distributed processors. Control software will be verified, validated, and tested in hardware and software test beds. Current plans for the software test bed involve using real time and nonreal time simulations of the power system. This paper will discuss the general simulation objectives and configurations, control architecture, interfaces between simulator and controls, types of tests, and facility configurations.

Sadler, Gerald G.↗

Smart Meter Pinging and Reading Through AMI Two-Way Communication Networks to Monitor Grid Edge Devices and DERs

Today’s power distribution system is changing to a power-electronics-enabled distribution system, especially with the increasing penetration of distributed energy resources (DERs). To monitor and manage those electronic devices and DERs at the grid edge, the advanced metering infrastructure (AMI) with two-way communications presents great potential. At present, extensive research explores the upstream communication from smart meters to electric utilities (e.g., meter reading) but few examine the downstream communication from the utilities to smart meters (e.g., meter pinging). This article discusses the AMI two-way communication and its recent industrial practice in the U.S., especially for applying the smart meter pinging functionality to monitor grid-edge devices and DERs. This paper then develops the two-way communication model and the network calculus method to quantify the impact of the two-way communication on the AMI network. In the end, the proposed method is validated with ns-3 simulation using the modified 13-node test feeder and real-world feeder systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimization of the deep neural network parameters for generating homogenized fuel assembly data for nodal codes

Homogenized fuel assembly (FA) data is a typical input data for nodal codes. Generating that data, however, could be time-consuming. One of promising ways to mitigate the computational burden of generating macroscopic cross-sections is to use trained artificial neural network (ANN) models for predicting nuclear data. However, there is a challenge to make the model support variable FA geometry. In this work, two most common types of FA were combined in one ANN model. Since there could be multiple ways of converting 2-dimensional FA data into 1-dimensional input vector for ANN, three different approaches of data flattening were evaluated. The input parameters included each fuel pin enrichment, fuel temperature, moderator temperature and boron concentration. The output parameters were 2-group macroscopic cross-sections (XS) and pin power distribution (HFF). A fully connected deep neural network (DNN) model was trained and tested using pre-generated data obtained with lattice physics code STREAM. The results of this study showed no statistically significant difference in the accuracy of XS and HFF generation for all 3 tested input vector orders. This means that fully connected DNN for XS generation demonstrated input sequence invariance. Results of comparing predicted XS data with reference solutions were found sufficiently close considering the reduction of computation time offered by ANN. Mean relative difference (MRD) for all output XS parameters was found below 0.7%, while HFF MRD was found higher compared to XS values, in some cases slightly exceeding 1%, mostly near guide tube locations. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Multi-agent voltage control in distribution systems using GAN-DRL-based approach

Active distribution grids can experience voltage fluctuations and violations due to the high penetration of variable distributed energy resources (DERs). These problems might occur because of the uncertain and variable generation natures of these resources, especially solar photovoltaic resources, during panel shadowing scenarios. Volt-VAR control (VVC) is an efficient method that controls the reactive power set-points of the inverters to regulate the voltage of distribution grids. Although several VVC approaches have been proposed recently, the performance of these approaches degrades significantly if behind-the-meter solar generation data are unobservable/missing. Therefore, it is necessary to impute missing/unobservable PV data accurately to be utilized in VVC approaches. Further, this paper proposes a model-free, data-driven, centrally trained, and decentrally executed multi-agent deep reinforcement learning-based VVC architecture to regulate the voltage of distribution networks. A generative adversarial network (GAN) is incorporated to impute the unobservable PV data accurately, which improves the performance of the proposed control architecture. The proposed multi-agent-soft-actor–critic algorithm (MASAC)-based VVC technique utilizes the actual PV dataset as well as the imputed dataset from the GAN framework to learn the optimal coordinated control policy for controlling the optimal reactive power set-points of PV inverters. The effectiveness of the proposed approach is analyzed on a modified IEEE 34-bus test case with added PV inverters. The results are compared and analyzed with a base case model with no VVC and VVC with a local droop control approach, genetic algorithm optimization, and a centralized soft actor–critic-based approach. Moreover, the performance of the proposed approach is compared with that of a multi-agent VVC framework without using the PV generation data and load information as the system state. The results illustrate that the proposed method with more state input improves the voltage profile and reduces the power loss of the network across various loading and PV generation scenarios.

14 SOLAR ENERGY↗

Dynamic Temporal Graph Sequence Data for Resilience-Oriented Distribution Network Reconfiguration

This dataset comprises temporal dynamic graph sequences generated from power grid simulations focused on grid reconfiguration to enhance resilience. The simulations model failure propagation under varying conditions, with nodes assigned distinct failure probabilities. For each time step, the dataset captures the evolution of node states (functional or failed) and features critical to grid operations, such as pv_output, load_profile, load_dispatch, dg_output, loss, and voltage. Node types include sources, normal loads, and nodes with specific equipment like PVs, micro turbines, or shunt capacitors. The dataset is structured to support the training of dynamic graph neural networks, facilitating research on node feature prediction and edge dynamics under failure scenarios. Three distinct configurations are included, providing a robust foundation for modeling power grid resilience.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Open solutions to distributed control in ground tracking stations

The advent of high speed local area networks has made it possible to interconnect small, powerful computers to function together as a single large computer. Today, distributed computer systems are the new paradigm for large scale computing systems. However, the communications provided by the local area network is only one part of the solution. The services and protocols used by the application programs to communicate across the network are as indispensable as the local area network. And the selection of services and protocols that do not match the system requirements will limit the capabilities, performance, and expansion of the system. Proprietary solutions are available but are usually limited to a select set of equipment. However, there are two solutions based on 'open' standards. The question that must be answered is 'which one is the best one for my job?' This paper examines a model for tracking stations and their requirements for interprocessor communications in the next century. The model and requirements are matched with the model and services provided by the five different software architectures and supporting protocol solutions. Several key services are examined in detail to determine which services and protocols most closely match the requirements for the tracking station environment. The study reveals that the protocols are tailored to the problem domains for which they were originally designed. Further, the study reveals that the process control model is the closest match to the tracking station model.

Heuser, William Randy↗

Deep Reinforcement Learning based Model-free On-line Dynamic Multi-Microgrid Formation to Enhance Resilience

Multi-microgrid formation (MMGF) is a promising solution for enhancing power system resilience. This paper proposes a new deep reinforcement learning (RL) based model-free on-line dynamic MMGF scheme. Additionally, the dynamic MMGF problem is formulated as a Markov decision process, and a complete deep RL framework is specially designed for the topologytransformable micro-grids. In order to reduce the large action space caused by flexible switch operations, a topology transformation method is proposed and an action-decoupling Q-value is applied. Then, a convolutional neural network (CNN) based multi-buffer double deep Q-network (CM-DDQN) is developed to further improve the learning ability of the original DQN method. The proposed deep RL method provides real-time computing to support the on-line dynamic MMGF scheme, and the scheme handles a long-term resilience enhancement problem using an adaptive on-line MMGF to defend changeable conditions. The effectiveness of the proposed method is validated using a 7-bus system and the IEEE 123-bus system. The results show strong learning ability, timely response for varying system conditions and convincing resilience enhancement.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Online Optimization for Networked Distributed Energy Resources With Time-Coupling Constraints

This paper proposes a Lyapunov optimization-based online distributed (LOOD) algorithmic framework for active distribution networks (ADNs) with numerous photovoltaic inverters and inverter air conditionings (IACs). In the proposed scheme, ADNs can track an active power setpoint reference at the substation in response to transmission-level requests while concurrently minimizing the social utility loss and ensuring the security of voltages. Conventional distributed optimization methods are rarely feasible to track the optimal solutions in fast variable environments using a fine-grained sampling interval where the underlying optimization problem evolves with the iterations of the algorithms. In contrast, based on the framework of online convex optimization (OCO), the developed approach uses a distributed algebraic update to compute the next round decisions relying on the current feedback of measurements. Notably, the time-coupling constraints of IACs are decoupled for online implementation with Lyapunov optimization technique. An incentive scheme is tailored to coordinate the customer-owned assets in lieu of the direct control from network operators. Optimality and convergency are characterized analytically. Finally, we corroborate the proposed method on a modified version of 33-node test feeder. Benchmark tests show that the proposed method is computationally and economically efficient, and outperforming existing algorithms.

active distribution networks↗