Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “plug”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Flight velocity effects on jet noise of several variations of a 48-tube suppressor installed on a plug nozzle

Because of the relatively high takeoff speeds of supersonic transport aircraft, it is important to know if the flight velocity affects the noise level of suppressor nozzles. To investigate this, a modified F-106B aircraft was used to conduct a series of flyover and static tests on a 48-tube suppressor installed on an uncooled plug nozzle. Comparison of flyover and static spectra indicated that flight velocity had little effect on the noise suppression of the 48-tube suppressor configuration. However, flight velocity adversely affected noise suppression of the 48-tube suppressor with an acoustic shroud and plug installed.

Burley, R. R.↗

A stochastic model of turbulent mixing with chemical reaction: Nitric oxide formulation in a plug-flow burner

A stochastic model of turbulent mixing was developed for a reactor in which mixing is represented by n-body fluid particle interactions. The model was used to justify the assumption (made in previous investigations of the role of turbulent mixing on burner generated thermal nitric oxide and carbon monoxide emissions) that for a simple plug flow reactor, composition nonuniformities can be described by a Gaussian distribution function in the local fuel:air equivalence ratio. Recent extensions of this stochastic model to include the combined effects of turbulent mixing and secondary air entrainment on thermal generation of nitric oxide in gas turbine combustors are discussed. Finally, rate limited upper and lower bounds of the nitric oxide produced by thermal fixation of molecular nitrogen and oxidation of organically bound fuel nitrogen are estimated on the basis of the stochastic model for a plug flow burner; these are compared with experimental measurements obtained using a laboratory burner operated over a wide range of test conditions; good agreement is obtained.

Flagan, R. C.↗

Cold-flow performance of several variations of a ram-air-cooled plug nozzle for supersonic-cruise aircraft

Experimental data were obtained with a 21.59 cm (8.5 in.) diameter cold-flow model in a static altitude facility to determine the thrust and pumping characteristics of several variations of a ram-air-cooled plug nozzle. Tests were conducted over a range of nozzle pressure ratios simulating supersonic cruise and takeoff conditions. Primary throat area was also varied to simulate afterburner on and off. Effect of plug size, outer shroud length, primary nozzle geometry, and varying amounts of secondary flow were investigated. At a supersonic cruise pressure ratio of 27, nozzle efficiencies were 99.7 percent for the best configurations.

Harrington, D. E.↗

Thrust performance of isolated 36-chute suppressor plug nozzles with and without ejectors at Mach numbers from 0 to 0.45

Plug nozzles with chute-type noise suppressors were tested with and without ejector shrouds at free-stream Mach numbers from 0 to 0.45 and over a range of nozzle pressure ratios from 2 to 4. A 36-chute suppressor nozzle with an ejector had an efficiency of 94.6 percent at an assumed takeoff pressure ratio of 3.0 and a Mach number of 0.36. This represents only a 3.4 percent performance penalty when compared with the 98 percent efficiency obtained with a previously tested unsuppressed plug nozzle.

Harrington, D. E.↗

Thrust performance of isolated, two-dimensional suppressed plug nozzles with and without ejectors at Mach numbers from 0 to 0.45

A series of two-dimensional plug nozzles was tested with and without ejector shrouds at free stream Mach numbers from 0 to 0.45 and over a range of nozzle pressure ratios from 2 to 4. These nozzles were also tested with and without chute noise suppressors. A two-dimensional plug nozzle has an efficiency of 96.1 percent at an assumed takeoff pressure ratio of 3.0 and Mach 0.36. A 12-chute suppressed nozzle with sidewalls has an efficiency of 81.0 percent (15.1 percent below the unsuppressed nozzle).

Harrington, D. E.↗

Cylindrical diffuser performance using a truncated plug nozzle

Cylindrical diffuser performance for a truncated plug nozzle without external flow was tested in a blowdown wind tunnel. The nozzle was designed for an exit Mach number of 1.9 and the plug was conical in shape from the throat and converged to the axis of symmetry at an angle of 10 degrees. The diffuser section was fashioned into two 13.97 cm lengths to facilitate boring of the duct diameter and to allow for testing of two different duct lengths. A slotted hypotube was installed in the base of the diffuser to measure pressure distribution down the centerline of the diffuser. The data obtained included: the typical centerline and sidewall pressure ratio variation along the diffuser, cell pressure ratio vs overall pressure ratio for long and short diffusers and a comparison of minimum experimental cell pressure ratio vs area ratio.

Galanga, F. L.↗

Wind tunnel performance tests of coannular plug nozzles

Wind tunnel performance test results and data analyses are presented for dual-flow plug nozzles applicable to supersonic cruise aircraft during takeoff and low-speed flight operation. Outer exhaust stream pressure ratios from 1.5 to 3.5 were tested; inner exhaust stream conditions were varied from very low, or bleed flow rates, up to a pressure ratio of 3.5. Mach numbers tested ranged from zero to 0.45. Measured thrust coefficients for the eight model configurations, operating at an external Mach number of 0.36 and an outer flow pressure ratio of 2.5, varied from 0.95 to 0.974 for high inner flow rates. At low inner flow, the performance ranged from 0.88 to 0.97 for the same operating conditions. The primary design variables influencing the performance levels were the annular height of the inner and outer nozzle throats (denoted by radius ratio - the ratio of inner-to-outer flowpath diameter at the nozzle throat), the plug geometry, and the inner stream flow rate.

Staid, P. S.↗

An experimental study on porous plug jet noise suppressor

This paper contains a description of the configuration and operating characteristics of a porous center body plug nozzle jet noise suppressor that provides shock free flow over a wide range of nozzle pressure ratios. The elimination of the 'shock associated noise' and 'screeching' is accomplished by equalization of pressure along the jet axis. Because of the geometrical features of the porous plug nozzle, shear noise reductions are also observed at all subsonic and supersonic flow conditions tested. Additional benefits are the localization of the noise sources in the flow and the reduction of the spatial scale of the structure of the jet flow, which enhance the performance of an acoustic shield or baffle.

Maestrello, L.↗

VCE early acoustic test results of General Electric's high-radius ratio coannular plug nozzle

Results of variable cycle engine (VCE) early acoustic engine and model scale tests are presented. A summary of an extensive series of far field acoustic, advanced acoustic, and exhaust plume velocity measurements with a laser velocimeter of inverted velocity and temperature profile, high radius ratio coannular plug nozzles on a YJ101 VCE static engine test vehicle are reviewed. Select model scale simulated flight acoustic measurements for an unsuppressed and a mechanical suppressed coannular plug nozzle are also discussed. The engine acoustic nozzle tests verify previous model scale noise reduction measurements. The engine measurements show 4 to 6 PNdB aft quadrant jet noise reduction and up to 7 PNdB forward quadrant shock noise reduction relative to a fully mixed conical nozzle at the same specific thrust and mixed pressure ratio. The influences of outer nozzle radius ratio, inner stream velocity ratio, and area ratio are discussed. Also, laser velocimeter measurements of mean velocity and turbulent velocity of the YJ101 engine are illustrated. Select model scale static and simulated flight acoustic measurements are shown which corroborate that coannular suppression is maintained in forward speed.

Knott, P. R.↗

Jet noise suppression by porous plug nozzles

Jet noise suppression data presented earlier by Maestrello for porous plug nozzles have been supplemented by the testing of a family of nozzles having an equivalent throat diameter of 11.77 cm. Two circular reference nozzles and eight plug nozzles having radius ratios of either 0.53 or 0.80 were tested at total pressure ratios of 1.60 to 4.00. Data were taken both with and without a forward motion of coannular flow jet, and some tests were made with a heated jet. Jet thrust was measured. The data were analyzed to show the effects of suppressor geometry on nozzle propulsive efficiency and jet noise. Jet noise reductions in overall sound pressure level of up to 15 dB were obtained with a 3.5 percent reduction in thrust, but reductions of 10 dB were obtained at thrust reductions on the order of 0.3 percent. The noise reductions for subsonic pressure ratios were much less than those for supersonic pressure ratios.

Bauer, A. B.↗

Quasi-Porous Plug With Vortex Chamber

Pressure-letdown valve combines quasi-porous-plug and vortex-chamber in one controllable unit. Valve useful in fossil-energy plants for reducing pressures in such erosive two-phase process streams as steam/water, coal slurries, or combustion gases with entrained particles. Quasi-Porous Plug consists of plenums separated by perforated plates. Number or size of perforations increases with each succeeding stage to compensate for expansion. In Vortex Chamber, control flow varies to control swirl and therefore difference between inlet and outlet pressures.

Walsh, J. V.↗

Sintered plug flow modulation of a vapor-liquid phase separator for a helium II vessel

Presented is a system for modulation of a superfluid (helium II) flow in a vapor-liquid phase separator, for use in cryogenic storage tanks in future space missions. The system consists of a semicircular mechanically operated shutter, downstream of the separator plug, rotated at 0.1 rpm to control the operational surface area of the separator. The mass flow rate was varied from 10 to 22 mg/s. Pressure gradients across the plug are also discussed.

Frederking, T. H. K.↗

Performance characteristics of an isolated coannular plug nozzle at transonic speeds

The Langley 16-Foot Transonic Tunnel was used to evaluate the performance characteristics of a coannular plug nozzle at static conditions (Mach number of 0) and at Mach numbers from 0.65 to 1.20. Jet total pressure ratio was varied from 1.0 (jet off) to 10.0. Thirty-seven configurations generated by the combination of three geometric variables - plug angle, shroud boattail length (fixed exit radius), and shroud extension length - were tested.

Mercer, C. E.↗

Double-O-Ring Plug For Leak Tests

Pressure plug features redundant O-ring bore seals and axial port opening laterally into space between O-rings to enable testing of seals. Axial passage in plug connected through radial passage to space between O-rings. Opening used to test O-rings, then sealed with smaller O-ring compressed by machine screw. Useful to seal test or cleanout holes normally kept closed in hydraulic actuators, pumps, and other pressurized systems.

Greene, James H.↗

Plug Would Collimate X Rays

Device creates narrow, well-defined beam for radiographic measurements of thickness. Cylindrical plug collimates and aligns X rays with respect to through holes in parts. Helps in determination of wall thickness by radiography. Lead absorbs X rays that do not pass axially through central hole. Lead/vinyl seals prevent off-axis rays from passing along periphery of plug.

Anders, Jeffrey E.↗

A combined Eulerian-Lagrangian two-phase flow analysis of SSME HPOTP nozzle plug trajectories. I - Methodology

A computer code has been developed for the analysis of SSME (Space Shuttle Main Engine) HPOTP (High Pressure Oxidizer Turbo Pump) nozzle plug trajectories in the turnaround duct downstream of the turbine. The algorithm is based on a combined Eulerian-Lagrangian analysis originally developed for the study of two-phase flows. The Lagrangian part of this analysis has been enhanced to include three-dimensional particle motion and the effect of particle-wall collisions in complex geometries (with a large number of boundaries). The sensitivity of the nozzle plug trajectories to a variety of parameters has been determined, via the qualitative analysis of a select number of computed trajectories. The results of extensive parametric studies have been reported in a companion paper.

De Jong, Frederik J.↗

Performance effects resulting from plugged liquid oxygen posts of the Space Shuttle Main Engine Injector

The paper discusses the performance effects resulting from plugged LOX posts of the Space Shuttle Main Engine Injector. The simulation was performed with the REFLEQS 2-D code. Analysis was performed axisymmetrically and injector surface was divided into several regions to account for the mixture ratio variation on the injector surface. The reduction of vaccum specific impulse was approximately 0.01 second per plugged LOX post. This reduction is an order of magnitude higher than the result of Space Shuttle flight reconstruction data. It is presumed that this overprediction is due to the axisymmetric simulation that smears local effects.

Kim, S.↗