Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “peaking capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Operando detection of Li plating during fast charging of Li-ion batteries using incremental capacity analysis

A major challenge that limits fast charging of Li-ion batteries is lithium (Li) plating on the graphite electrode. Furthermore, it remains challenging to detect and diagnose Li plating in operando during charging. In this work, incremental capacity (IC) analysis is applied while charging graphite-NMC pouch cells over a range of rates from C/2 to 4C. Three-electrode pouch cell measurements and post-mortem SEM imaging was performed to demonstrate that the onset of Li plating is correlated with a specific IC peak. IC analysis was also applied to study the fast-charge performance of multi-layer pouch cells with 3-D anode architectures. The results demonstrate that: 1) IC curves have a characteristic peak that is an indicator of Li plating during fast charging, which grows in magnitude as charging rate increases; 2) the plating IC peak correlates with the voltage minimum of the graphite anode, indicating a transition from intercalation to plating; 3) the plating IC peak is sensitive to small amounts of Li plating; 4) IC analysis can be applied to study Li plating in novel cell architectures; 5) the plating IC peak evolves during extended fast-charge cycling, which is a result of reduced Li plating as the Li inventory decreases.

25 ENERGY STORAGE↗

Coupled machine learning–ecosystem ensemble models substantially improve predictions of nitrous oxide (N 2 O) fluxes from US croplands

Nitrous oxide (N 2 O) is a potent and persistent greenhouse gas, with rising atmospheric concentrations driven in part by inefficient use of synthetic nitrogen (N) fertilizers in agriculture. Predicting soil N 2 O emissions is challenging due to high spatial and temporal variability arising from complex soil biogeochemical processes. Process-based ecosystem models and standalone machine learning (ML) approaches without extensive site-specific calibration often miss high-emission episodes. Here, we show how an Ensemble Modeling System (EMS) based on outputs from an ensemble of ecosystem models coupled to an ensemble of ML models can improve predictions and understanding of N 2 O fluxes from US cropland. Trained and validated on ~12,000 N 2 O chamber measurements at 17 US Midwest sites (six crops, 35 management practices), the EMS accurately predicted daily fluxes of N 2 O at both training (R 2 = 0.84, RMSE = 16.4 g N ha −1 d −1 ) and held-out testing sites (R 2 = 0.84, RMSE = 6.2 g N ha −1 d −1 ). Analyses identified six dominant N 2 O drivers: soil organic carbon (SOC), NH 4 + , NO 3 - , water-filled pore space, temperature, and aboveground biomass production. Wet, warm soils produced large N 2 O peaks only with sufficient SOC and mineral N; in low-SOC soils, fluxes remained low. Incorporating these drivers into process-based models might significantly improve their predictive capacity. The EMS demonstrates a strong potential to predict N 2 O fluxes at unseen sites, enabling more reliable regional inventories, improved gap-filling where measurements are sparse, and enhanced understanding of mechanisms to advance targeted mitigation strategies in food, feed, and bioenergy crops.

AI↗

Structure and magnetism of the triangular lattice material YbBO 3

Abstract YbBO 3 is a member of the orthoborate family of materials which contains a triangular arrangement of Yb 3+ ions. Here we study the physical properties of YbBO 3 with neutron diffraction, inelastic neutron scattering, specific heat, and ac susceptibility measurements. The neutron diffraction measurements confirm that our samples of YbBO 3 crystallize in the monoclinic space group C 2 / c (#15) which contains two crystallographically distinct Yb 3+ sites decorating a slightly distorted triangular lattice. Heat capacity and ac susceptibility measurements indicate a potential transition to magnetic order at 0.4 K. In agreement with these observations, neutron diffraction measurements at 0.044 K observe magnetic Bragg peaks which can be indexed by a propagation vector of (0 0 1). Although determining a unique spin configuration corresponding to the observed magnetic Bragg peaks is not possible, model refinements indicate that the ordered moments are likely in the range of 0.4–0.9 μ B and, notably, require moments on both Yb sites. In addition to the magnetic Bragg peaks, diffuse scattering at low Q is observed indicating that the transition does not correspond to complete long range magnetic order. The two-site picture for YbBO 3 is further evidenced by the number of crystal field excitations observed by inelastic neutron scattering measurements. Together these results show that YbBO 3 is a two-site triangular lattice material with signatures of long-range order as well as shorter ranged spin correlations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Data from: Coupled machine learning-ecosystem ensemble models substantially improve predictions of nitrous oxide (N 2 O) fluxes from US croplands

Nitrous oxide (N₂O) is a potent and persistent greenhouse gas, with rising atmospheric concentrations driven in part by inefficient use of synthetic nitrogen (N) fertilizers in agriculture. Predicting soil N₂O emissions is challenging due to high spatial and temporal variability arising from complex soil biogeochemical processes. Process-based ecosystem models and standalone machine learning (ML) approaches without extensive site-specific calibration often miss high emission episodes. Here, we show how an Ensemble Modeling System (EMS) based on outputs from an ensemble of ecosystem models coupled to an ensemble of ML models can improve predictions and understanding of N2O fluxes from US cropland. Trained and validated on approximately 12,000 N2O chamber measurements at 17 U.S. Midwest sites (six crops, 35 management practices), the EMS accurately predicted daily fluxes of N2O at both training (R² = 0.84, RMSE = 16.4 g N ha⁻¹ d⁻¹) and held-out testing sites (R² = 0.84, RMSE = 6.2 g N ha⁻¹ d⁻¹). Analyses identified six dominant N₂O drivers: soil organic carbon (SOC), NH₄⁺, NO₃⁻, water-filled pore space (WFPS), soil temperature, and biomass production. Wet, warm soils produced large N₂O peaks only with sufficient SOC and mineral N; in low-SOC soils, fluxes remained low. Incorporating these drivers into process-based models might significantly improve their predictive capacity. The EMS demonstrates a strong potential to predict N₂O fluxes at unseen sites, enabling more reliable regional inventories, improved gap-filling where measurements are sparse, and enhanced understanding of mechanisms to advance targeted mitigation strategies in food, feed, and bioenergy crops.

agricultural sciences↗

Historical Evidence of Importance to the Industrialization of Flat-plate Silicon Photovoltaic Systems, Volume 2

Problems which may arise as the low cost silicon solar array (LSSA) project attempts to industrialize the production technologies are defined. The charge to insure an annual production capability of 500 MW peak for the photovoltaic supply industry by 1986 was critically examined, and focused on one of the motivations behind this goal-concern over the timely development of industrial capacity to supply anticipated demand. Conclusions from the analysis are utilized in a discussion of LSSA's industrialization plans, particularly the plans for pilot, demonstration and commercial scale production plants. Specific recommendations for the implementation of an industrialization task and the disposition of the project quantity goal were derived.

Smith, J. L.↗

Computer simulation of immobilized pH gradients at acidic and alkaline extremes - A quest for extended pH intervals

Computer simulations of the concentration profiles of simple biprotic ampholytes with Delta pKs 1, 2, and 3, on immobilized pH gradients (IPG) at extreme pH values (pH 3-4 and pH 10-11) show markedly skewed steady-state profiles with increasing kurtosis at higher Delta pK values. Across neutrality, all the peaks are symmetric irrespective of their Delta pK values, but they show very high contribution to the conductivity of the background gel and significant alteration of the local buffering capacity. The problems of skewness, due to the exponential conductivity profiles at low and high pHs, and of gel burning due to a strong electroosmotic flow generated by the net charges in the gel matrix, also at low and high pHs, are solved by incorporating in the IPG gel a strong viscosity gradient. This is generated by a gradient of linear polyacrylamide which is trapped in the gel by the polymerization process.

Mosher, Richard A.↗

Fast Data Acquisition For Mass Spectrometer

New equipment has speed and capacity to process time-of-flight data. System relies on fast, compact waveform digitizer with 32-k memory coupled to personal computer. With digitizer, system captures all mass peaks on each 25- to 35-microseconds cycle of spectrometer.

Lincoln, K. A.↗

Solid-State Transformer and Hybrid Transformer With Integrated Energy Storage in Active Distribution Grids: Technical and Economic Comparison, Dispatch, and Control

Solid-state transformer (SST) and hybrid transformer (HT) are promising alternatives to the line-frequency transformer (LFT) in smart grids. The SST features medium-frequency isolation, full controllability for voltage regulation, reactive power compensation, and the capability of battery energy storage system (BESS) integration with multiport configuration. The HT has a partially-rated converter for fractional controllability and can integrate a small BESS. Fast grid-edge voltage fluctuations from increased solar photovoltaic (PV) and electric vehicle (EV) penetration are difficult to manage for mechanical load tap changers. Hence, along with the trend towards more BESS in the grid, the controllability and the storage integration capability of the SST and HT are of strong interest. However, a review of literature shows existing SST and HT research is mostly at converter level, while system-level assessments are scarce. Assessing technical and economic impacts is critical to understanding the benefits and role of the SST and HT to guide future research, which is presented for the first time in this article. Experimental results from medium-voltage (MV) SST and MV HT prototypes are shown to confirm equipment-level feasibility, where the voltage controllability waveforms of a MV HT prototype are reported for the first time. Comparative simulations are performed on a modified IEEE 34-bus system. Here, a grid-model-less decentralized grid-edge voltage control method and a day-ahead BESS dispatch method are proposed for the SST and HT. The simulations show that the SST and HT with integrated storage can host more PV, achieve peak shaving, mitigate voltage fluctuation and reverse power flow, and support energy arbitrage for operational cost reduction, as compared to the LFT. Moreover, comprehensive analyses of net present value (NPV) and internal rate of return (IRR) are performed under different installed PV capacities, HT’s partial converter ratings, and BESS capacities. Sensitivities to future cost reductions of the PV and BESS are studied. Although the NPV and IRR are currently negative, 60% capital cost reduction or 150% revenue increase will make the SST and HT economically viable in the use case studied.

14 SOLAR ENERGY↗

Illinois Compressed Air Energy Storage

Compressed Air Storage Energy (CAES) is one of the few mid- technology readiness level (TRL) energy storage technologies that can address the long-duration infrastructure needed for dealing with variable electric output from renewable energy sources and be reliable backup source for replacing natural gas during supply interruptions. In CAES the goal is to capture and store compressed air in subsurface sedimentary strata when off-peak power is available, or there is a need for grid balancing. The stored high-pressure air is returned to the surface and used to power turbines during reductions in either renewable energy or supply issues with fossil fuels. The Illinois CAES project evaluates the feasibility of capturing surplus electrical energy from renewable sources and off-peak energy at a fossil fuel power plant at the University of Illinois Urbana - Champaign (UIUC) campus. The UIUC Abbott Power Plant uses natural gas and coal to generate electricity (capacity: 35 MWe by coal and 49 MWe by NG). UIUC receives additional electricity from on campus solar farm, and off-campus wind farm. Also, UIUC offsets electricity usage by integrating geothermal energy systems into building heating Also, UIUC offsets steam, hot and chilled water usage by integrating geothermal energy systems into building heating and cooling systems. Furthermore, the two UIUC solar farms (Solar Farm 1 is 21 acres and Solar Farm 2 is 54 acres) to generate 4.68 megawatts (MW) and 12.1 MW, respectively. Campus receives 8.6% of the wind-generated electricity from the Rail Splitter Wind Farm. The project objectives were to design an integrated system to 1) capture surplus electrical energy from renewable sources and the Abbott Power Plant using a CAES system, 2) store both the compressed air and the thermal heat generated by compression in the subsurface as part of an adiabatic system, 3) simulate the movement of the air and heat in the subsurface, 4) recover the compressed air and stored thermal heat to rotate turbine generators during sustained interruption due to weather events or fossil fuel disruptions.

03 NATURAL GAS↗

Structural optimization of turbine blade firtrees

On the basis of the present optimization equation for the structural capacity of a turbine blade attachment firtree, the optimum of the lobe circular fillet radius in the blade and in the turbine disk is determined. In order to further diminish peak stress in firtree design, an elliptical fillet radius is selected in place of the circular one. Two-dimensional stress analysis results for a three-lobe firtree with elliptical radius shows a 14-percent stress reduction in the blade necks (where cracking has been experienced) over the current, four-lobe firtree design.

Lee, R. L.↗

Evaluation of phase change thermal storage in a cascade heat pump

Here this study proposes a low-global warming potential cascade heat pump system with integrated phase change material (PCM) for combined space heating and cooling. PCM is embedded in the intermediate heat exchanger that couples an outdoor R290 refrigerant circuit and an indoor CO 2 circuit. We used a clustering method to develop seasonally representative load and ambient temperature profiles for residential buildings in Minneapolis, Minnesota. We simulated the system peak shaving performance on the selected representative days, assuming three different PCM options including ice (0 °C), tetradecane (5.6 °C), and a commercially available PCM, SP9 (10.5 °C). The baseline was the same cascade system without thermal storage. We investigated the effect of both thermal energy storage capacity (kWh th ) and PCM transition temperature on system performance. The results show that higher thermal energy storage capacity shaves more electric energy until it reaches a maximum value set by the load characteristics of the building. SP9, with the highest transition temperature, shaves the most electric energy, while ice shaves the least. Moreover, ice has the highest charging cost, especially in the cooling season when the outdoor circuit has to operate at an evaporating temperature lower than 0 °C to make ice. Our results show that SP9 presents the lowest levelized cost of storage, closely followed by ice. A lower off-peak electricity rate benefits ice more than SP9 or tetradecane because ice has the largest charging cost penalty.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A simple and fast algorithm for estimating the capacity credit of solar and storage

Energy storage is a leading option to enhance the resource adequacy contribution of solar energy. Detailed analysis of the capacity credit of solar energy and energy storage is limited in part due to the data intensive and computationally complex nature of probabilistic resource adequacy assessments. This paper presents a simple algorithm for calculating the capacity credit of energy-limited resources that, due to the low computational and data needs, is well suited to exploratory analysis. Validation against benchmarks based on probabilistic techniques shows that it can yield similar insights. The method is used to evaluate the impact of different solar and storage configurations, particularly with respect to the strategy for coupling storage and solar photovoltaic systems. Furthermore, application of the method to a case study of utilities in Florida, where solar is rapidly growing and demand peaks in the winter and summer, demonstrates that it can improve on rules of thumb used in practice by some utilities. If storage is required to charge only from solar, periods of high demand driven by cold weather events accompanied by lower solar production can result in a capacity credit of solar and storage that is less than the capacity credit of storage alone.

14 SOLAR ENERGY↗

Economic Case for Replacing High-Emitting Peaker Plants with Fuel Cells for Automotive Applications

The identification of clean and cost-effective solutions to replace high-emitting peaker plants and support a just transition is a challenge faced by utilities across the US today. However, falling costs of hydrogen production as well as the widespread availability of fuel cells for automotive applications have made them an attractive option for a zero-emission peak power supply. This study evaluates the techno-economics, operation, and environmental justice impacts of siting a peaker plant based on fuel cells for automotive applications through the lens of the existing Intermountain Power Plant, in order to supply peak power to the Los Angeles basin. Compared to the fossil fuel-fired peakers in operation today, the fuel cell peaker would be lower-cost up to a 17% capacity factor with Inflation Reduction Act incentives while also reducing air pollution in environmental justice communities. With corresponding transmission upgrades, the Intermountain site could host up to a 5 GW fuel cell peaker in the future.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Wave

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wave energy conversion device. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen. While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the wave energy, NLR used a wave energy converter model from PacWave. These devices can be equipped with accumulators and pressure relief values to smooth the power output by storing and releasing hydraulic energy. Using a peak power output of 10 MW, the model created two 25-minute profiles: one with and one without the accumulators and pressure relief valves. To down select the profile data from the native resolution of 20 Hz to 1 Hz, NLR took the mean of every 20 data points. NLR experimented with two simulated wave energy power plants: one that peaks at 10 MW, and one that peaks at 5 MW. These profiles were scaled for the physical 1.25 MW electrolyzer by multiplying the original profiles by one eighth and one quarter, respectively. The first profile matches the capacity rating of eight of the 1.25 MW electrolyzers, while the second matches four electrolyzers. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wave electrolysis experiment and is formatted as follows: {technology}-{accumulator?}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “wavePacWave-Noacc_4-400.zip” represents the 25 minute-long experiment using the PacWave’s wave energy converter model, equipped with no accumulator, connected to four 1.25-MW electrolyzers with their power supplies set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. An experiment, labeled “characterization_200.zip”, demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all wave profiles combined into one dataset labeled "combined_wave_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis.

08 HYDROGEN↗

A baseline maritime satellite communication system

This paper describes a baseline system for maritime communications via satellite during the 1980s. The system model employs three geostationary satellites with global coverage antennas. Access to the system is controlled by a master station; user access is based on time-ordered polling or random access. Each Thor-Delta launched satellite has an RF power of 100 W (spinner) or 250 W (three-axis stabilized), and provides 10 equivalent duplex voice channels for up to 1500 ships with average waiting times of approximately 2.5 minutes. The satellite capacity is bounded by the available bandwidth to 50 such channels, which can serve up to 10,000 ships with an average waiting time of 5 minutes. The ships must have peak antenna gains of approximately 15.5 dB or 22.5 dB for the two cases (10 or 50 voice channels) when a spinner satellite is used; the required gains are 4 dB lower if a three-axis stabilized satellite is used. The ship antenna requirements can be reduced by 8 to 10 dB by employing a high-gain multi-beam phased array antenna on the satellite.

Durrani, S. H.↗

Techno-Economic Analysis for a Potential Geothermal District Heating System in Tuttle, Oklahoma: Preprint

Geothermal deep direct use (DDU) has potential across a wide swath of the United States but is underutilized due to challenging project economics associated with developing a deep geothermal resource for a large-scale and variable heat demand. The National Renewable Energy Laboratory (NREL) and University of Oklahoma evaluated the feasibility of a geothermal district heating (GDH) and cooling system in two schools and 250 houses by utilizing existing oil and gas (O&G) wells in Tuttle, Oklahoma. Heating and cooling demand in the two schools and a typical single-family house were modeled using EnergyPlus building energy simulation software. The modeling results indicated that annual heating demand in two schools and 250 houses is approximately 2.61 GWhth, and cooling demand in the two schools is approximately 2.65 GWhth. In this scope, the techno-economic analysis (TEA) was conducted using the GEOPHIRES tool combined with the TOUGH2 reservoir simulator. The reservoir performance, including geothermal heat production capacity, was modeled by the reservoir simulator TOUGH2. Then, levelized cost of heat (LCOH) was calculated using GEOPHIRES version 3.0, which includes new features such as hourly heat load optimization and peak performance evaluation. Geothermal reservoir temperature was estimated as 90.5 degrees C at a total depth of 3.3 km by the regional average temperature gradient of 22.8 degrees C/km and validated by cation geothermometer calculations. Four production scenarios with two different well configurations and two different heat load profiles have been developed for well flow rates ranging between 3.1 kg/s and 9.3 kg/s. The LCOH of the district heating and cooling system was calculated between $95 and $210/MWh ($28/MMBtu to $62/MMBtu) for four different production scenarios. Typical natural gas prices for residential customers in Oklahoma have ranged from 9 to 19 $/MMBtu over the past decade, which indicates a challenge for deployment of such a GDH system.

deep direct-use↗

Techno-Economic Analysis for a Potential Geothermal District Heating System in Tuttle, Oklahoma

Geothermal deep direct use (DDU) has potential across a wide swath of the United States but is underutilized due to challenging project economics associated with developing a deep geothermal resource for a large-scale and variable heat demand. The National Renewable Energy Laboratory (NREL) and University of Oklahoma evaluated the feasibility of a geothermal district heating (GDH) and cooling system in two schools and 250 houses by utilizing existing oil and gas (O&G) wells in Tuttle, Oklahoma. Heating and cooling demand in the two schools and a typical single-family house were modeled using EnergyPlus building energy simulation software. The modeling results indicated that annual heating demand in two schools and 250 houses is approximately 2.61 GWhth, and cooling demand in the two schools is approximately 2.65 GWhth. In this scope, the techno-economic analysis (TEA) was conducted using the GEOPHIRES tool combined with the TOUGH2 reservoir simulator. The reservoir performance, including geothermal heat production capacity, was modeled by the reservoir simulator TOUGH2. Then, levelized cost of heat (LCOH) was calculated using GEOPHIRES version 3.0, which includes new features such as hourly heat load optimization and peak performance evaluation. Geothermal reservoir temperature was estimated as 90.5 degrees C at a total depth of 3.3 km by the regional average temperature gradient of 22.8 degrees C/km and validated by cation geothermometer calculations. Four production scenarios with two different well configurations and two different heat load profiles have been developed for well flow rates ranging between 3.1 kg/s and 9.3 kg/s. The LCOH of the district heating and cooling system was calculated between $95 and $210/MWh ($28/MMBtu to $62/MMBtu) for four different production scenarios. Typical natural gas prices for residential customers in Oklahoma have ranged from 9 to 19 $/MMBtu over the past decade, which indicates a challenge for deployment of such a GDH system.

deep direct-use↗