Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “parameter calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Hand-Eye Calibration of Robonaut

NASA's Human Space Flight program depends heavily on Extra-Vehicular Activities (EVA's) performed by human astronauts. EVA is a high risk environment that requires extensive training and ground support. In collaboration with the Defense Advanced Research Projects Agency (DARPA), NASA is conducting a ground development project to produce a robotic astronaut's assistant, called Robonaut, that could help reduce human EVA time and workload. The project described in this paper designed and implemented a hand-eye calibration scheme for Robonaut, Unit A. The intent of this calibration scheme is to improve hand-eye coordination of the robot. The basic approach is to use kinematic and stereo vision measurements, namely the joint angles self-reported by the right arm and 3-D positions of a calibration fixture as measured by vision, to estimate the transformation from Robonaut's base coordinate system to its hand coordinate system and to its vision coordinate system. Two methods of gathering data sets have been developed, along with software to support each. In the first, the system observes the robotic arm and neck angles as the robot is operated under external control, and measures the 3-D position of a calibration fixture using Robonaut's stereo cameras, and logs these data. In the second, the system drives the arm and neck through a set of pre-recorded configurations, and data are again logged. Two variants of the calibration scheme have been developed. The full calibration scheme is a batch procedure that estimates all relevant kinematic parameters of the arm and neck of the robot The daily calibration scheme estimates only joint offsets for each rotational joint on the arm and neck, which are assumed to change from day to day. The schemes have been designed to be automatic and easy to use so that the robot can be fully recalibrated when needed such as after repair, upgrade, etc, and can be partially recalibrated after each power cycle. The scheme has been implemented on Robonaut Unit A and has been shown to reduce mismatch between kinematically derived positions and visually derived positions from a mean of 13.75cm using the previous calibration to means of 1.85cm using a full calibration and 2.02cm using a suboptimal but faster daily calibration. This improved calibration has already enabled the robot to more accurately reach for and grasp objects that it sees within its workspace. The system has been used to support an autonomous wrench-grasping experiment and significantly improved the workspace positioning of the hand based on visually derived wrench position. estimates.

Nickels, Kevin↗

Which calibration-pulse location method is robust?

The Threshold method, with high threshold and contiguous-block parameter values, was found to be a robust method of locating calibration pulses in the presence of light-leak and shutter-edge pulses within the calibration window. Tests used digitized calibration-window background and light-pulse data from the Landsat-5 Thematic Mapper (TM) instrument, analyzed by special software on an Apple II+ personal computer and on a VAX 11/780 minicomputer.

Gunther, F. J.↗

Roughness Parameter Optimization of the McClain Model in GlennICE

Aircraft icing remains a significant threat to aviation safety. Software that predicts the impingement and ice accretion on full aircraft geometries and aircraft components are in demand and NASA Glenn is committed to produce software that meets this need. One of the key parameters affecting an accurate prediction of iced geometry is the effect of ice roughness on the heat transfer coefficient. While many efforts have been made to implement the roughness in the flow solver, this report takes a correlation for roughness height distribution that is based on experimental measurements and demonstrates how to relate those measurements to an augmentation to the heat transfer coefficient provided by the flow solution. The outcome of this effort was the calibration of defaults for user supplied parameters to this correlation through comparison with 95 large glaze conditions from experiment by adjusting user-supplied parameters in the roughness augmentation equation.

Aircraft Icing↗

Overview of Aqua MODIS 10-year On-orbit Calibration and Performance

Since launch in May 2002, Aqua MODIS has successfully operated for nearly 10 years, continuously collecting global datasets for scientific studies of key parameters of the earth's land, ocean, and atmospheric properties and their changes over time. The quality of these geophysical parameters relies on the input quality of sensor calibrated radiances. MODIS observations are made in 36 spectral bands with wavelengths ranging from visible (VIS) to longwave infrared (LWIR). Its reflective solar bands (RSB) are calibrated using data collected from its on-board solar diffuser and regularly scheduled lunar views. The thermal emissive bands (TEB) are calibrated using an on-board blackbody (BB). The changes in the sensor's spectral and spatial characteristics are monitored by an on-board spectroradiometric calibration assembly (SRCA). This paper presents an overview of Aqua MODIS 10-year on-orbit operation and calibration activities, from launch to present, and summarizes its on-orbit radiometric, spectral, and spatial calibration and characterization performance. In addition, it will illustrate and discuss on-orbit changes in sensor characteristics and corrections applied to continuously maintain the sensor level 1B (L1B) data quality, as well as lessons learned that could benefit future calibration efforts.

Xiong, X.↗

Approach to derivation of SIR-C science requirements for calibration

Many of the experiments proposed for the forthcoming SIR-C mission require calibrated data, for example those which emphasize (1) deriving quantitative geophysical information (e.g., surface roughness and dielectric constant), (2) monitoring daily and seasonal changes in the Earth's surface (e.g., soil moisture), (3) extending local case studies to regional and worldwide scales, and (4) using SIR-C data with other spaceborne sensors (e.g., ERS-1, JERS-1, and Radarsat). There are three different aspects to the SIR-C calibration problem: radiometric and geometric calibration, which have been previously reported, and polarimetric calibration. The study described in this paper is an attempt at determining the science requirements for polarimetric calibration for SIR-C. A model describing the effect of miscalibration is presented first, followed by an example describing how to assess the calibration requirements specific to an experiment. The effects of miscalibration on some commonly used polarimetric parameters are also discussed. It is shown that polarimetric calibration requirements are strongly application dependent. In consequence, the SIR-C investigators are advised to assess the calibration requirements of their own experiment. A set of numbers summarizing SIR-C polarimetric calibration goals concludes this paper.

Dubois, Pascale C.↗

Model Calibration for Cancer Risk Projections According to Uncertain Data

This paper presents forward and inverse formulations for the calibration of computational models according to uncertain data. Uncertainty in the data might be caused by a poor metrology system, measurement noise, missing or uncontrollable input variables, or by the inability to directly measure the inputs and/or outputs of interest. The forward approach performs the calibration in the space of the model’s output thereby requiring repeated model simulations. Conversely, the inverse approach leverages an ensemble of solutions to an inverse problem in order to perform the calibration in the space of the model’s parameters. As such, the computational demands of the inverse approach are considerably lower. These strategies are applied to the calibration of a radiation model that in-forms cancer risk projections for future deep space missions.

uncertainty quantification↗

Calibration of the Airborne Visible/Infrared Imaging Spectrometer in the Laboratory

Imaging spectrometry data must be spectrally, radiometrically and geometrically calibrated in order to: 1) derive physical parameters from measured spectral radiance, 2) compare data acquired from different regions and at different times, 3) compare and analyze the imaging spectrometry data with data acquired from other calibrated sensors, and 4) compare and analyze data with results from computer models. The calibration of AVIRIS data is the process by which laboratory characterization data are applied to raw instrument data (digitized number versus spectral channels) to produce quantitative spectra (radiance versus wavelength) for each image pixel in units of spectral radiance. The AVIRIS sensor and calibration process are described by Vane and the application of the calibration data to the raw digital data is described by Green. This calibration process is validated for in-flight performance of the sensor using a rigorous ground-truth campaign. This workshop paper reviews the laboratory characterization data set that is used in the AVIRIS calibration process. The laboratory measurements used to acquire the calibration data are divided into three classes: 1) spectral calibration, 2) radiometric calibration, and 3) spatial calibration.

Green Robert O.↗

Calibration and Validation of a Finite ELement Model of THor-K Anthropomorphic Test Device for Aerospace Safety Applications

The THOR anthropomorphic test device (ATD) has been developed and continuously improved by the National Highway Traffic Safety Administration to provide automotive manufacturers an advanced tool that can be used to assess the injury risk of vehicle occupants in crash tests. Recently, a series of modifications were completed to improve the biofidelity of THOR ATD [1]. The updated THOR Modification Kit (THOR-K) ATD was employed at Wright-Patterson Air Base in 22 impact tests in three configurations: vertical, lateral, and spinal [2]. Although a computational finite element (FE) model of the THOR had been previously developed [3], updates to the model were needed to incorporate the recent changes in the modification kit. The main goal of this study was to develop and validate a FE model of the THOR-K ATD. The CAD drawings of the THOR-K ATD were reviewed and FE models were developed for the updated parts. For example, the head-skin geometry was found to change significantly, so its model was re-meshed (Fig. 1a). A protocol was developed to calibrate each component identified as key to the kinematic and kinetic response of the THOR-K head/neck ATD FE model (Fig. 1b). The available ATD tests were divided in two groups: a) calibration tests where the unknown material parameters of deformable parts (e.g., head skin, pelvis foam) were optimized to match the data and b) validation tests where the model response was only compared with test data by calculating their score using CORrelation and Analysis (CORA) rating system. Finally, the whole ATD model was validated under horizontal-, vertical-, and lateral-loading conditions against data recorded in the Wright Patterson tests [2]. Overall, the final THOR-K ATD model developed in this study is shown to respond similarly to the ATD in all validation tests. This good performance indicates that the optimization performed during calibration by using the CORA score as objective function is not test specific. Therefore confidence is provided in the ATD model for uses in predicting response in test conditions not performed in this study such those observed in the spacecraft landing. Comparison studies with ATD and human models may also be performed to contribute to future changes in THOR ATD design in an effort to improve its biofidelity, which has been traditionally based on post-mortem human subject testing and designer experience.

Putnam, J. B.↗

MODIS Pre-launch and On-orbit Calibration

Two nearly identical MODIS instruments are currently operated on-orbit: one on-board the EOS Terra spacecraft launched in December 1999 and the other on-board the Aqua spacecraft launched in May 2002. Both sensors went through extensive pre-launch calibration and characterization activities that had provided many critically important parameters and sensor characteristics in support of their on-orbit operation and calibration. On-orbit each MODIS instrument is calibrated and characterized via a set of on-board calibrators (OBC) that include a solar diffuser (SD), a solar diffuser stability monitor (SDSM), a blackbody (BB), and a spectroradiometric calibration assembly (SRCA). This paper provides an overview of MODIS calibration and characterization methodologies and measurements performed, pre-launch and on-orbit, for both the reflective solar bands (RSB) and thermal emissive bands (TEB). It discusses issues on the calibration transfer from ground to on-board and from pre-launch to on-orbit, and illustrates the calibration consistency between Terra and Aqua MODIS. Examples in three key areas, radiometric, spatial, and spectral, are presented. Also addressed in the paper are the challenges and lessons learned during MODIS pre-launch and on-orbit calibration and performance.

Xiong, X.↗

C-band radar calibration using GEOS-3

The various methods of determining tracking radar measurement error parameters are described, along with the projected accuracy of results. Typical examples and results for calibration of radars tracking the GEOS-3 satellite are presented.

Krabill, W. B.↗

The Badhwar-O'Neill 2020 Model

The Badhwar-O'Neill (BON) model has been used for some time to describe the galactic cosmic ray (GCR) environment encountered in deep space by astronauts and sensitive electronics. The most recent version of the model, BON2014, was calibrated to available measurements to reduce model errors for particles and energies of significance to astronaut exposure. Although subsequent studies showed the model to be reasonably accurate for such applications, modifications to the sunspot number (SSN) classification system and a large number of new high precision measurements suggested the need to develop an improved and more capable model. In this work, the BON2020 model is described. The new model relies on daily integral flux from the Advanced Composition Explorer Cosmic Ray Isotope Spectrometer (ACE/CRIS) to describe solar activity. For time periods not covered by ACE/CRIS, the updated international SSN database is used. Parameters in the new model are calibrated to available data, which includes the new Alpha Magnetic Spectrometer (AMS-02) and Payload for Antimatter Matter Exploration and Light-nuclei Astrophysics (PAMELA) high-precision measurements. It is found that the BON2020 model is a significant improvement over BON2014. Systematic errors associated with BON2014 have been removed. The average relative error of the BON2020 model compared to all available measurements is found to be <1%, and BON2020 is found to be within ±15% of a large fraction of the available measurements (26,269 of 27,646 → 95%).

Slaba, Tony C.↗

The Badhwar-O'Neill 2020 Model

The Badhwar-O’Neill (BON) model has been used for some time to describe the galactic cosmic ray (GCR) environment encountered in deep space by astronauts and sensitive electronics. The most recent version of the model, BON2014, was calibrated to available measurements to reduce model errors for particles and energies of significance to astronaut exposure. Although subsequent studies showed the model to be reasonably accurate for such applications, modifications to the sunspot number (SSN) classification system and a large number of new high-precision measurements suggested the need to develop an improved and more capable model. In this work, the BON2020 model is described. The new model relies on daily integral flux from the Advanced Composition Explorer Cosmic Ray Isotope Spectrometer (ACE/CRIS) to describe solar activity. For time periods not covered by ACE/CRIS, the updated international SSN database is used. Parameters in the new model are calibrated to available data, which includes the new Alpha Magnetic Spectrometer (AMS-02) and Payload for Antimatter Matter Exploration and Light-nuclei Astrophysics (PAMELA) high-precision measurements. It is found that the BON2020 model is a significant improvement over BON2014. Systematic errors associated with BON2014 have been removed. The average relative error of the BON2020 model compared to all available measurements is found to be <1%, and BON2020 is found to be within +15% of a large fraction of the available measurements (26,269 of 27,646  95%.

T C Slaba↗

Tracking system analytic calibration activities for the Mariner Mars 1971 mission

This report describes the functions of the Tracking System Analytic Calibration activity for Mariner Mars 1971 (MM'71), its objectives for this and future missions, and the support provided to the MM'71 Navigation Team during operations. The support functions encompass calibration of tracking data by estimating physical parameters whose uncertainties represent limitations to navigational accuracy, and detailed analysis of the tracking data to uncover and resolve any anomalies. Separate articles treat the activities and results of producing calibrations for the various error sources: Deep Space Station Locations, timing and polar motion, charged particles, and the troposphere. Two other articles are also included dis- - cussing the effects of the media error sources on orbit determination and the merits of the smoothing technique used for DRIVID.

Facilities↗

The tracking system analytic calibration activity for Mariner Mars 1971: Its function and scope

The functions of the Tracking System Analytic Calibration activity for Mariner Mars 1971 (MM'71), its objectives for this and future missions, and the support provided to the MM'71 Navigation Team during operations are described. Support functions encompass calibration of tracking data by estimating physical parameters whose uncertainties represent limitations to navigational accuracy, and detailed analysis of the tracking data to uncover and resolve any anomalies. Separate articles treat the activities and results of producing calibrations for the various error sources: Deep Space Station Locations, timing and polar motion, charged particles, and the troposphere. Two other articles are also included discussing the effects of the media error sources on orbit determination and the merits of the smoothing technique used for DRIVID.

Madrid, G. A.↗

Automated Probabilistic Finite Element Model Calibration Tool Based on Uncertainty Quantification and Machine Learning

Qualification and certification of safety critical parts is a hurdle to the adoption of metallic additively manufactured components for aerospace vehicle applications. Challenges include variability in part properties due to inconsistent defect distribution and microstructure. Understanding of the process through finite element modeling (FEM), and process control through in-situ monitoring, may result in significant improvements; however, solutions useful to manufacturers will require large volumes of data and automated data utilization. Toward this end, a generalizable automated FEM calibration paradigm is developed. This paradigm leverages existing and novel tools from machine learning and uncertainty quantification to enable the automatic calibration of FEMs without requiring prior knowledge of the model performance across input parameter space, including meshing and solver settings, which can require time consuming manual model probing or cause noisy and inconsistent predictions. The result is a probabilistic distribution of calibrated and validated FEM input parameters targeting measured data.

Additive manufacturing model calibration finite el↗

Labyrinth Seal Flutter Analysis and Test Validation in Support of Robust Rocket Engine Design

High energy-density turbomachines, like the SSME turbopumps, utilize labyrinth seals, also referred to as knife-edge seals, to control leakage flow. The pressure drop for such seals is order of magnitude higher than comparable jet engine seals. This is aggravated by the requirement of tight clearances resulting in possible unfavorable fluid-structure interaction of the seal system (seal flutter). To demonstrate these characteristics, a benchmark case of a High Pressure Oxygen Turbopump (HPOTP) outlet Labyrinth seal was studied in detail. First, an analytical assessment of the seal stability was conducted using a Pratt & Whitney legacy seal flutter code. Sensitivity parameters including pressure drop, rotor-to-stator running clearances and cavity volumes were examined and modeling strategies established. Second, a concurrent experimental investigation was undertaken to validate the stability of the seal at the equivalent operating conditions of the pump. Actual pump hardware was used to construct the test rig, also referred to as the (Flutter Rig). The flutter rig did not include rotational effects or temperature. However, the use of Hydrogen gas at high inlet pressure provided good representation of the critical parameters affecting flutter especially the speed of sound. The flutter code predictions showed consistent trends in good agreement with the experimental data. The rig test program produced a stability threshold empirical parameter that separated operation with and without flutter. This empirical parameter was used to establish the seal build clearances to avoid flutter while providing the required cooling flow metering. The calibrated flutter code along with the empirical flutter parameter was used to redesign the baseline seal resulting in a flutter-free robust configuration. Provisions for incorporation of mechanical damping devices were introduced in the redesigned seal to ensure added robustness

El-Aini, Yehia↗

Pre-Launch Performance Trending of Joint Polar Satellite System (JPSS) Advanced Technology Microwave Sounder (ATMS)

The Advanced Technology Microwave Sounder (ATMS) microwave radiometer instrument is utilized on-board NOAA’s Joint Polar Satellite System (JPSS) fleet of spacecraft to perform temperature and water vapor soundings of Earth’s atmosphere. Consisting of 22 channels over a frequency range from 22 to 183 GHz, ATMS provides high-impact observations for numerical weather prediction (NWP) models. A general description of the ATMS instrument is discussed in [1]. There are five ATMS flight units in the polar-orbiting JPSS program; three are currently on-orbit and two are pending launch. The first ATMS was flown on the Suomi National Polar-orbiting Partnership (SNPP) satellite, launched in 2011. The second ATMS was launched on the NOAA-20 (previously JPSS-1) satellite in 2017. The third ATMS was launched on the NOAA-21 (previously JPSS-2) satellite in 2022. The SNPP and NOAA-20 ATMS units are operational. The NOAA-21 ATMS unit is completing on-orbit commissioning and checkout, having achieved provisional maturity status in December 2022 with validated maturity expected in May 2023 [2]. The fourth and fifth ATMS units are planned for the JPSS-3 (launch ~2028) and JPSS-4 (launch ~2032) satellites [3]. This paper will focus on trending performance characteristics of each JPSS ATMS build from the pre-launch activities. Pre-launch trending of some parameters have been previously published up to the JPSS-3 mission [4][5]. This paper differs from and expands the scope of the prior work as it will include all five of the JPSS ATMS builds. The entire suite of JPSS ATMS units have completed their pre-ship instrument-level I&T and verification activities. These activities include a radiometric performance characterization of each instrument. In addition to comparing the performance across builds, the performance will also be compared to requirements and specifications where applicable. The on-orbit performance of the launched units will be excluded from the scope of this paper in order to focus on evaluations that are common across all builds. The post-launch performance of SNPP ATMS is detailed in [1][6][7][8]. The post-launch performance of NOAA-20 ATMS is detailed in [6][8][9]. The pre-launch characterization of the ATMS occurs at both subassembly-level and instrument-level testing. The antenna subsystem is tested at Northrop Grumman’s Compact Antenna Test Range (CATR) in Azusa, CA [9]. This testing characterizes the antenna pattern and the pointing performance of the scan drive mechanism and antenna subsystem. Trended parameters from this evaluation will include beam pointing accuracy, beamwidth, and beam efficiency. These parameters are captured in each instrument’s Calibration Data Book [10]. Instrument-level radiometric performance evaluation is primarily done during thermal vacuum (TVAC) calibration testing at Northrop Grumman’s Azusa, CA facility [9]. A general description of the calibration activities is presented in [1][9]. The testing involves inferring a scene target brightness temperature (TB) and comparing it to the actual scene TB while the instrument is at flight-like temperature and pressure environmental conditions. Trended parameters from this activity will include Noise Equivalent Delta Temperature (NEDT), nonlinearity, radiometric accuracy, gain stability, striping, and inter-channel noise correlation. The trending evaluation will allow for a direct comparison of the ATMS performance across builds. The paper will highlight observed performance improvements.

Edward J Kim↗

Status of Terra MODIS Operation, Calibration, and Performance

Since launch in December 1999, Terra MODIS has successfully operated for nearly 15 years, making continuous observations. Data products derived from MODIS observations have significantly contributed to a wide range of studies of key geophysical parameters of the earth's eco-system of land, ocean, and atmosphere, and their changes over time. The quality of MODIS data products relies on the dedicated effort to monitor and sustain instrument health and operation, to calibrate and update sensor parameters and properties, and to improve calibration algorithms. MODIS observations are made in 36 spectral bands, covering wavelengths from visible to long-wave infrared. The reflective solar bands (1-19 and 26) are primarily calibrated by a solar diffuser (SD) panel and regularly scheduled lunar observations. The thermal emissive bands (20-25 and 27- 36) calibration is referenced to an on-board blackbody (BB) source. On-orbit changes in the sensor spectral and spatial characteristics are monitored by a spectroradiometric calibration assembly (SRCA). This paper provides an overview of Terra MODIS on-orbit operation and calibration activities and implementation strategies. It presents and summarizes sensor on-orbit performance using nearly 15 years of data from its telemetry, on-board calibrators, and lunar observations. Also discussed in this paper are changes in sensor characteristics, corrections applied to maintain MODIS level 1B (L1B) data quality, and efforts for future improvements.

Terra↗