Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical interference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Performance comparison of fiber tips in interferometric displacement mesurements

Fiber optic displacement sensors have many potential advantages over traditional displacement measurement techniques, including small size, immunity to electromagnetic interference, electrical isolation, and high resolution. In this report, we focus on an interferometric fiber optic sensor, where the gap between the fiber tip and the device under test forms a Fabry-Perot resonant cavity. An optical interrogator measures the reflected intensity at wavelengths ranging from 1510 to 1590 nm. The spacing between resonant frequencies allows us to determine the distance from the tip to the device under test. We consider ferrule connector angled physical contact (FC/APC), ferrule connector ultra physical contact (FC/UPC) and unpolished cleaved tips and compare their influence on sensor performance. A plane wave propagation model is proposed for predicting tip effects. Comparisons are made on the basis of sensor measurement range, resolution, and sensitivity to changes in test conditions. In this paper, we discuss the experimental setup, detail our analysis, and present test results with recommendations for the applications of each tip.

42 ENGINEERING↗

Confocal simultaneous phase-shifting interferometry

In order to implement the ultraprecise measurement with large range and long working distance in confocal microscopy, confocal simultaneous phase-shifting interferometry (C-SPSI) has been presented. Four channel interference signals, with {pi}/2 phase shift between each other, are detected simultaneously in C-SPSI. The actual surface height is then calculated by combining the optical sectioning with the phase unwrapping in the main cycle of the interference phase response, and the main cycle is determined using the bipolar property of differential confocal microscopy. Experimental results showed that 1 nm of axial depth resolution was achieved for either low- or high-NA objective lenses. The reflectivity disturbance resistibility of C-SPSI was demonstrated by imaging a typical microcircuit specimen. C-SPSI breaks through the restriction of low NA on the axial depth resolution of confocal microscopy effectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent phase-modulation transfer in counterpropagating parametric down-conversion

Distributed positive feedback established by a counterpropagating three-wave mixing process in a submicrometer structured second-order nonlinear medium leads to mirrorless parametric oscillation with unusual spectral properties. In this work, we demonstrate experimentally and theoretically that the phase modulation of the pump is coherently transferred to the co-propagating parametric wave, while the counterpropagating wave retains a narrow bandwidth and high coherence. The main mechanisms responsible for these properties are the maximized convective separation between the counterpropagating waves and the associated phase-locking between the pump and the co-propagating parametric wave. This suggests that mirrorless optical parametric oscillators can be pumped with incoherent light and still generate highly coherent backward-propagating radiation.

74 ATOMIC AND MOLECULAR PHYSICS↗

Kinetics of atoms in a bichromatic field formed by elliptically polarised waves

The kinetics of atoms in a bichromatic field formed by waves with an arbitrary elliptical polarisation is considered. Analytical expressions are derived for the force and the friction and diffusion coefficients within the model of an atom with the j {sub g} = 1/2 → j {sub e} = 3/2 optical transition. These expressions are presented in the general form as an expansion in gradients of light field parameters. Some specific features of the kinetics of atoms are found, which are due to the interference contributions to the friction and diffusion coefficients. The kinetics of atoms in the field of an optical lattice formed as a result of the interference of a wave with a uniform elliptical polarisation and a nonuniformly polarised dissipative field is analysed. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Self referencing attosecond interferometer with zeptosecond precision

In this work we demonstrate the generation of two intense, ultrafast laser pulses that allow a controlled interferometric measurement of higher harmonic generation pulses with 12.8 attoseconds in resolution (half the atomic unit of time) and a precision as low as 680 zeptoseconds (10–21 seconds). We create two replicas of a driving femtosecond pulse which share the same optical path except at the focus where they converge to two foci. An attosecond pulse train emerges from each focus through the process of high harmonic generation. The two attosecond pulse trains from each focus interfere in the far field producing a clear interference pattern in the extreme ultraviolet region. By controlling the relative optical phase (carrier envelope phase for pulsed fields) between the two driving laser pulses we are able to actively influence the delay between the pulses and are able to perform very stable and precise pump-probe experiments. Because of the phase shaping operation occurs homogeneously across the entire spatial profile, we effectively create two indistinguishable intense laser pulses or a common path interferometer for attosecond pulses. Commonality across the two beams means that they are extremely stable to environmental and mechanical fluctuations up to a Rayleigh range from the focus. In our opinion this represents an ideal source for homodyne and heterodyne spectroscopic measurements with sub-attosecond precision.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A new white beam x-ray microdiffraction setup on the BM32 beamline at the European Synchrotron Radiation Facility

A white beam microdiffraction setup has been developed on the bending magnet source BM32 at the European Synchrotron Radiation Facility. The instrument allows routine submicrometer beam diffraction to perform orientation and strain mapping of polycrystalline samples. The setup features large source to optics distances allowing large demagnification ratios and small beam sizes. The optics of the beamline is used for beam conditioning upstream a secondary source, suppressing any possible interference of beam conditioning on beam size and position. The setup has been designed for an easy and efficient operation with position control tools embedded on the sample stage, a high magnification large aperture optical microscope, and fast readout detectors. Switching from the white beam mode to the monochromatic mode is made easy by an automatic procedure and allows the determination of both the deviatoric and hydrostatic strain tensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interference of Temporally Distinguishable Photons Using Frequency-Resolved Detection

Here, we demonstrate quantum interference of three photons that are distinguishable in time by resolving them in the conjugate parameter frequency. We show that the multiphoton interference pattern in our setup can be manipulated by tuning the relative delays between the photons, without the need for reconfiguring the optical network. Furthermore, we observe that the symmetries of our optical network and the spectral amplitude of the input photons are manifested in the interference pattern. We also demonstrate time-reversed Hong-Ou-Mandel-like interference in the spectral correlations using time-bin entangled photon pairs. By adding a time-varying dispersion using a phase modulator, our setup can be used to realize dynamically reconfigurable and scalable boson sampling in the time domain as well as frequency-resolved multiboson correlation sampling.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PSF and MTF Measurement Methods for Thick CCD Sensor Characterization

Knowledge of the point spread function (PSF) of the sensors to be used in the Large Synoptic Survey Telescope (LSST) camera is essential for optimal extraction of subtle galaxy shape distortions caused by gravitational weak lensing. We have developed a number of techniques for measuring the PSF of candidate CCD sensors to be used in the LSST camera, each with its own strengths and weaknesses. The two main optical PSF measurement techniques that we use are the direct Virtual Knife Edge (VKE) scan as developed by Karcher, et al. and the indirect interference fringe method after Andersen and Sorensen that measures the modulation transfer function (MTF) directly. The PSF is derived from the MTF by Fourier transform. Other non-optical PSF measurement techniques that we employ include {sup 55}Fe x-ray cluster image size measurements and statistical distribution analysis, and cosmic ray muon track size measurements, but are not addressed here. The VKE technique utilizes a diffraction-limited spot produced by a Point-Projection Microscope (PPM) that is scanned across the sensor with sub-pixel resolution. This technique closely simulates the actual operating condition of the sensor in the telescope with the source spot size having an f/number close to the actual telescope design value. The interference fringe method uses a simple equal-optical-path Michelson-type interferometer with a single-mode fiber source that produces interference fringes with 100% contrast over a wide spatial frequency range sufficient to measure the MTF of the sensor directly. The merits of each measurement technique and results from the various measurement techniques on prototype LSST sensors are presented and compared.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interference effects in the high-order harmonic amplification process in the active medium of a plasma-based X-ray laser modulated by an optical field

We study the process of propagation of high harmonics of optical radiation in an active medium of a plasma-based X-ray laser, simultaneously irradiated by an intense optical field of fundamental frequency. It is shown that for moderate plasma dispersion of the active medium at the frequency of the modulating optical field, the energy and relative amplitudes of the harmonics at the output of the medium are determined by their phases at the entrance to the medium, as well as by the time-delay of the harmonics with respect to the modulating field. These dependences are due to interference of high-order harmonics with a set of multi-frequency fields generated by each of the harmonics in the process of coherent scattering in a modulated active medium. The possibilities of using these effects to increase the efficiency of harmonic amplification, to control the harmonic spectrum, and determine the relative phases at the entrance to the medium are discussed on the example of the active medium of hydrogen-like Li{sup 2+} ions (with a 13.5 nm wavelength of an inverted transition). (paper)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical bandgap of single- and multi-layered amorphous germanium ultra-thin films

Accurate optical methods are required to determine the energy bandgap of amorphous semiconductors and elucidate the role of quantum confinement in nanometer-scale, ultra-thin absorbing layers. Here, we provide a critical comparison between well-established methods that are generally employed to determine the optical bandgap of thin-film amorphous semiconductors, starting from normal-incidence reflectance and transmittance measurements. First, we demonstrate that a more accurate estimate of the optical bandgap can be achieved by using a multiple-reflection interference model. We show that this model generates more reliable results compared to the widely accepted single-pass absorption method. Second, we compare two most representative methods (Tauc and Cody plots) that are extensively used to determine the optical bandgap of thin-film amorphous semiconductors starting from the extracted absorption coefficient. Analysis of the experimental absorption data acquired for ultra-thin amorphous germanium (a-Ge) layers demonstrates that the Cody model is able to provide a less ambiguous energy bandgap value. Finally, we apply our proposed method to experimentally determine the optical bandgap of a-Ge/SiO{sub 2} superlattices with single and multiple a-Ge layers down to 2 nm thickness.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhancement of the resolution of full-field optical coherence tomography by using a colour image sensor

The influence of white balance in a colour image detector on the resolution of a full-field optical coherence tomograph (FFOCT) is studied. The change in the interference pulse width depending on the white balance tuning is estimated in the cases of a thermal radiation source (incandescent lamp) and a white light emitting diode. It is shown that by tuning white balance of the detector in a certain range, the FFOCT resolution can be increased by 20 % as compared to the resolution, attained with the use of a monochrome detector. (optical coherence tomography)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multimodal hard x-ray nanoprobe facility by nested Montel mirrors aimed for 40nm resolution at Taiwan Photon Source

The hard X-ray nanoprobe facility at Taiwan Photon Source (TPS) provides multimodal X-ray detections, including XRF, XAS, XEOL, projection microscope, CDI, etc. Resulting from the large numerical aperture obtained by utilizing nested Montel mirrors, the beamline with a moderate length 75 meters can conduct similar performance with those beamlines longer than 100 meters. The mirrors are symmetrically placed with a 45 degrees cut. The beamline optics is thus designed to take the advantage of the symmetry of mirrors such that a round focal spot is accomplished. The size and the divergence of the focus spot are simulated around 40 nm and 6.29 mrad, respectively. The whole facility including the beamline and the stations will be operated under vacuum to preserve the photon coherence as well as to prevent the system from unnecessary environmental interference. A SEM in close cooperation with laser interferometers is equipped to precisely locate the position of the sample. This endstation is scheduled to be commissioned in the fall of 2016.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent optical transients observed in rubidium atomic line filtered Doppler velocimetry experiments

We report the first successful results from our novel Rubidium Atomic Line Filtered (RALF) Doppler velocimetry apparatus, along with unanticipated oscillatory signals due to coherent optical transients generated within pure Rb vapor cells. RALF is a high-velocity and high-acceleration extension of the well-known Doppler Global Velocimetry (DGV) technique for constructing multi-dimensional flow velocity vector maps in aerodynamics experiments [H. Komine, U.S. Patent No. 4,919,536 (24 April 1990)]. RALF exploits the frequency dependence of pressure-broadened Rb atom optical absorptions in a heated Rb/N{sub 2} gas cell to encode the Doppler shift of reflected near-resonant (λ{sub 0} ≈ 780.24 nm) laser light onto the intensity transmitted by the cell. The present RALF apparatus combines fiber optic and free-space components and was built to determine suitable operating conditions and performance parameters for the Rb/N{sub 2} gas cells. It yields single-spot velocities of thin laser-driven-flyer test surfaces and incorporates a simultaneous Photonic Doppler Velocimetry (PDV) channel [Strand et al., Rev. Sci. Instrum. 77, 083108 (2006)] for validation of the RALF results, which we demonstrate here over the v = 0 to 1 km/s range. Both RALF and DGV presume the vapor cells to be simple Beer's Law optical absorbers, so we were quite surprised to observe oscillatory signals in experiments employing low pressure pure Rb vapor cells. We interpret these oscillations as interference between the Doppler shifted reflected light and the Free Induction Decay (FID) coherent optical transient produced within the pure Rb cells at the original laser frequency; this is confirmed by direct comparison of the PDV and FID signals. We attribute the different behaviors of the Rb/N{sub 2} vs. Rb gas cells to efficient dephasing of the atomic/optical coherences by Rb-N{sub 2} collisions. The minimum necessary N{sub 2} buffer gas density ≈0.3 amagat translates into a smallest useful velocity range of 0 to 2 km/s, which can readily be extended to cover the 0 to 10 km/s range, and beyond. The recognition that coherent optical transients can be produced within low pressure vapor cells during velocimetry experiments may offer new insights into some quantitative discrepancies reported in earlier DGV studies. Future plans include “line-RALF” experiments with streak camera detection, and two-dimensional surface velocity mapping using pulsed laser illumination and/or gated intensified CCD camera detection.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An electron impact emission spectroscopy flux sensor for monitoring deposition rate at high background gas pressure with improved accuracy

Electron impact emission spectroscopy (EIES) has been proven to be a critical tool for film composition control during codeposition processes for the fabrication of multicomponent thin film materials including the high-efficiency copper-indium-gallium-diselenide photovoltaic cells. This technique is highly specific to atomic species because the emission spectrum of each element is unique, and the typical width of atomic emission lines is very narrow. Noninterfering emission lines can generally be allocated to different atomic species. However, the electron impact emission spectra of many molecular species are often broadband in nature. When the optical emission from an EIES sensor is measured by using a wavelength selection device with a modest resolution, such as an optical filter or monochromator, the emissions from common residual gases may interfere with that from the vapor flux and cause erroneous flux measurement. The interference is most pronounced when measuring low flux density with the presence of gases such as in reactive deposition processes. This problem is solved by using a novel EIES sensor that has two electron impact excitation sources in separate compartments but with one common port for optical output. The vapor flux is allowed to pass through one compartment only. Using a tristate excitation scheme and appropriate signal processing technique, the interfering signals from residual gases can be completely eliminated from the output signal of the EIES monitor for process control. Data obtained from Cu and Ga evaporations with the presence of common residual gases such as CO{sub 2} and H{sub 2}O are shown to demonstrate the improvement in sensor performance. The new EIES sensor is capable of eliminating the effect of interfering residual gases with pressure as high as in the upper 10{sup -5} Torr range.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Flat-lens focusing of electrons on the surface of a topological insulator

We propose the implementation of an electronic Veselago lens on the conducting surface of a three-dimensional topological insulator (such as Bi{sub 2}Te{sub 3}). The negative refraction needed for such a flat lens results from the sign change in the curvature of the Fermi surface, changing from a circular to a snowflakelike shape across a sufficiently large electrostatic potential step. No interband transition (as in graphene) is needed. For this reason, and because the topological insulator provides protection against backscattering, the potential step is able to focus a broad range of incident angles. We calculate the quantum interference pattern produced by a point source, generalizing the analogous optical calculation to include the effect of a noncircular Fermi surface (having a nonzero conic constant).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Metal-embedded fiber optic sensor packaging and signal demodulation scheme towards high-frequency dynamic measurements in harsh environments

Optical fiber-based sensors are commonly used for industrial monitoring and control processes due to their small size, resistance to electromagnetic interference, and ability to perform a wide variety of high-precision measurements. However, implementing optical fiber sensors in harsh environments is challenging because they are small and fragile. Proper packaging of fiber-optic sensors could extend their use to harsh environments, including at high temperature and under high radiation. Furthermore, conventional fiber optic-based measurement systems often use computationally expensive signal processing algorithms which hinder their use in high-frequency dynamic applications. This work reports on the design of an optical fiber-pressure sensor system based on low-coherence interferometry that uses a metal-embedded optical fiber to provide a robust sensor package. Additionally, a novel phase demodulation scheme is proposed to extract length changes from the deformation of a thin diaphragm within a Fabry–Pérot cavity to measure pressure. The sensor has been tested to ±100 kPa, has a theoretical linear response over a 270 kPa dynamic range (24 dB maximum signal-to-noise ratio), and can resolve pressure transients up to 3910 kPa/s. Sampling at 100 kHz, the present sensor can resolve 2 kPa dynamic pressures at frequencies up to 2 kHz. Faster transients on the order of tens to hundreds of kHz can theoretically be resolved at the expense of decreasing the maximum resolvable amplitude. A methodology for designing a LCI pressure sensor for a given application is outlined based on the limitations imposed by the Nyquist criterion, the diaphragm's resonant frequency, the LCI optoelectronics, and the phase demodulation scheme. The sensor is the first to implement a low-coherence light source and a Fabry–Pérot interferometer designed to provide real-time high-fidelity pressure measurements using a metal-embedded optical fiber. The demonstrated sensor provides a platform for sensing in harsh conditions such as in nuclear and energy applications.

47 OTHER INSTRUMENTATION↗

Time-normalized correlation function of ultracold atomic gas released from an optical lattice

The time-correlation function of ultracold atomic gas is theoretically investigated. Atoms are initially confined in an optical lattice and in a Mott insulator regime. We consider the effect of gravity on the time correlation among atomic wave functions when the atomic cloud is released from the optical lattice. The time-correlation function in this process displays sharp peaks, a feature that is analogous to the spatial-normalized correlation observed in recent experiments. The origin and properties of the interference pattern are theoretically investigated in detail. Similar to the spatial correlation, the time correlation in expanding atomic clouds reveals the ordering of indistinguishable particles in an optical lattice. Experimental detection scheme and its potential use in the measurement of gravitational acceleration are briefly discussed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Magneto-optical measurement of magnetic field and electrical current on a short pulse high energy pulsed power accelerator

We describe a direct magneto-optical approach to measuring the magnetic field driven by a narrow pulse width (<10 ns), 20 kA electrical current flow in the transmission line of a high energy pulsed power accelerator. The magnetic field and electrical current are among the most important operating parameters in a pulsed power accelerator and are critical to understanding the properties of the radiation output. However, accurately measuring these fields and electrical currents using conventional pulsed power diagnostics is difficult due to the strength of ionizing radiation and electromagnetic interference. Our approach uses a fiber coupled laser beam with a rare earth element sensing crystal sensor that is highly resistant to electromagnetic interference and does not require external calibration. Here, we focus on device theory, operating parameters, results from an experiment on a high energy pulsed power accelerator, and comparison to a conventional electrical current shunt sensor.

42 ENGINEERING↗