Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

The Single-Volume Scatter Camera

The multi-institution Single-Volume Scatter Camera (SVSC) collaboration led by Sandia National Laboratories (SNL) is developing a compact, high-efficiency double-scatter neutron imaging system. Kinematic emission imaging of fission-energy neutrons can be used to detect, locate, and spatially characterize special nuclear material. Neutron-scatter cameras, analogous to Compton imagers for gamma ray detection, have a wide field of view, good event-by-event angular resolution, and spectral sensitivity. Existing systems, however, suffer from large size and/or poor efficiency. We are developing high-efficiency scatter cameras with small form factors by detecting both neutron scatters in a compact active volume. This effort requires development and characterization of individual system components, namely fast organic scintillators, photodetectors, electronics, and reconstruction algorithms. In this presentation, we will focus on characterization measurements of several SVSC candidate scintillators. The SVSC collaboration is investigating two system concepts: the monolithic design in which isotropically emitted photons are detected on the sides of the volume, and the optically segmented design in which scintillation light is channeled along scintillator bars to segmented photodetector readout. For each of these approaches, we will describe the construction and performance of prototype systems. We will conclude by summarizing lessons learned, comparing and contrasting the two system designs, and outlining plans for the next iteration of prototype design and construction.

Manfredi, Juan↗

Generation of realistic input parameters for simulating atmospheric point-spread functions at astronomical observatories

High-fidelity simulated astronomical images are an important tool in developing and measuring the performance of image-processing algorithms, particularly for high precision measurements of cosmic shear – correlated distortions of images of distant galaxies due to weak gravitational lensing caused by the large-scale mass distribution in the Universe. For unbiased measurements of cosmic shear, all other sources of correlated image distortions must be modeled or removed. One such source is the correlated blurring of images due to optical turbulence in the atmosphere, which dominates the point-spread function (PSF) for ground-based instruments. In this work, we leverage data from weather forecasting models to produce wind speeds and directions, and turbulence parameters, that are realistically correlated with altitude. To study the resulting correlations in the size and shape of the PSF, we generate simulated images of the PSF across a ~10 square-degree field of view – the size of the camera focal plane for the Vera C. Rubin Observatory in Chile – using weather data and historical seeing for a geographic location near the Observatory. We make quantitative predictions for two-point correlation functions (2PCF) that are used in analyses of cosmic shear. We observe a strong anisotropy in the two-dimensional 2PCF, which is expected based on observations in real images, and study the dependence of the orientation of the anisotropy on dominant wind directions near the ground and at higher altitudes.

79 ASTRONOMY AND ASTROPHYSICS↗

Multi-camera imaging to characterize jet and liner uniformity on the Plasma Liner Experiment (PLX)

At Plasma Liner Experiment, a set of 36 coaxial plasma guns are deployed quasi-uniformly over a 9 ft diameter spherical chamber and are used to form a high-Z spherically compressive plasma liner. Simulations indicate that for the concept to ultimately achieve optimal target density and temperature, a high degree of timing uniformity is required between all guns. Therefore, to aid in quantifying and correcting gun-to-gun nonuniformities, a key diagnostic will consist of up to six fisheye-view CCD cameras positioned inside the main chamber such that each has all plasma guns within its view. The individual cameras can be triggered at different times to determine each plasma jet’s muzzle velocity and structure for different operating conditions. This camera array is currently under development, and the implementation needs and challenges for this camera array are discussed here. Additionally, we detail the analysis methodology for determining jet-to-jet uniformity deviations and how we can correct them, thereby improving overall liner uniformity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimizing the sensitivity of high repetition rate broadband transient optical spectroscopy with modified shot-to-shot detection

A major limitation of transient optical spectroscopy is that relatively high laser fluences are required to enable broadband, multichannel detection with acceptable signal-to-noise levels. Under typical experimental conditions, many condensed phase and nanoscale materials exhibit fluence-dependent dynamics, including higher order effects such as carrier–carrier annihilation. With the proliferation of commercial laser systems, offering both high repetition rates and high pulse energies, have come new opportunities for high sensitivity pump-probe measurements at low pump fluences. However, experimental considerations needed to fully leverage the statistical advantage of these laser systems have not been fully described. Here, we demonstrate a high repetition rate, broadband transient spectrometer capable of multichannel shot-to-shot detection at 90 kHz. Importantly, we find that several high-speed cameras exhibit a time-domain fixed pattern noise resulting from interleaved analog-to-digital converters, which is particularly detrimental to the conventional “ON/OFF” modulation scheme used in pump-probe spectroscopy. Using a modified modulation and data processing scheme, we achieve a noise level of 10−5 in 4 s for differential transmission, an order of magnitude lower than for commercial 1 kHz transient spectrometers for the same acquisition time. We leverage the high sensitivity of this system to measure the differential transmission of monolayer graphene at low pump fluence. We show that signals on the order of 10−6 OD can be measured, enabling a new data acquisition regime for low-dimensional materials.

47 OTHER INSTRUMENTATION↗

Time-refraction near the critical angle and angular streaking with attosecond resolution [Invited]

We study the time-refraction of optical waves as they propagate through a time-varying slab and find the frequency shift associated with the abrupt change in the refractive index. We discover a geometrical mechanism responsible for an ultrafast blueshift followed by a redshift, occurring while the refractive index is increased monotonically. Furthermore, we find high sensitivity to incident angles near the traditional critical angle and unravel a new critical angle that varies in time. Finally, we introduce an innovative concept of a streak camera design that utilizes ultrafast nonlinearities in time-varying media and offers attosecond resolution capabilities.

Fruhling, Colton (ORCID:0000000282968802)↗

3D velocity map imaging of electrons with TPX3CAM

In this report we demonstrate three-dimensional velocity map imaging of low energy electrons using a TPX3CAM, where the three-dimensional momentum information [$p_x, p_y, p_z$] is encoded in position and timing [x, y, t] of hits on the camera sensor. We make use of the camera sensor for the [x, y] information and a constant fraction discriminator and fast time to digital converter in the camera for the time information. We illustrate the capabilities of our apparatus by presenting above threshold ionization measurements of xenon, which produces well defined structures in the momentum resolved photoelectron yield.

79 ASTRONOMY AND ASTROPHYSICS↗

Fringing Analysis and Simulation for the Vera C. Rubin Observatory’s Legacy Survey of Space and Time

Abstract The presence of fringing in astronomical Charge-Coupled Device (CCD) images will have an impact on photometric quality and measurements. Yet its impact on the Vera C. Rubin Observatory’s Legacy Survey of Space and Time (LSST) has not been fully studied. We present a detailed study on fringing for CCDs already implemented on the Rubin Observatory LSST Camera’s focal plane. After making physical measurements and knowing the compositions, we developed a model for the e2v CCDs. We present a method to fit for the internal height variation of the epoxy layer within the sensors based on fringing measurements in a laboratory setting. This method is generic enough that it can be easily modified to work for other CCDs. Using the derived fringing model, we successfully reproduce comparable fringing amplitudes that match the observed levels in images taken by existing telescopes with different optical designs. This model is then used to forecast the expected level of fringing in a single LSST y -band sky background exposure with Rubin telescope optics in the presence of a realistic time-varying sky spectrum. The predicted fringing amplitude in LSST images ranges from 0.04% to 0.2% depending on the location of a CCD on the focal plane. We find that the predicted variation in surface brightness caused by fringing in LSST y -band sky background images is about 0.6 μ Jy arcsec − 2 , which is 40 times larger than the current measurement error. We conclude that it is necessary to include fringing correction in the Rubin’s LSST image processing pipeline.

Astronomy & Astrophysics↗

GEMINI Case Study

Sandia's GEMINI-Scout Mine Rescue Robot is an unmanned ground vehicle designed to enter potentially hazardous environments to explore, assess, and evaluate dangerous situations first responders may face when conducting a rescue mission. GEMINI is approximately four feet long and two feet tall, which enables the robot to maneuver through small locations on rough terrains caused by earthquakes, fires, or radiological incidents. GEMINI uses track propulsion to climb stairs, travel through gravel and sand pits, pivot in place, and traverse 45-degree climbs with few problems. Furthermore, the vehicle's dual tracked-chassis design allows it to operate in hostile, dark, muddy, high-temperature, and explosive debris-strewn environments, while maintaining efficient ground mobility. The mobility and modularity of the vehicle allow for easy integration of sensors to conduct gas and temperature sensing and offers pan/tilt, zoom color, and thermal camera video streaming capabilities. The vehicle is also able to carry a payload of about 50 pounds of batteries and can handle an additional 200 pounds of payload, whether for additional diagnostics, supplies, or clothing for those trapped in an effected area. GEMINI is remotely operated through a wireless connection and an onboard computer running a customized embedded control application, which directly communicates to all onboard components except for the audio and video systems. When line of sight is not possible, operators use a shockresistant fiber optic cable to ensure continuous functionality of the vehicle. This allows for direct local control of the vehicle, which streams collected data back to the operator for enhanced situational awareness. In addition, the vehicle incorporates safety features such as explosion proof housing to ensure safe electronic operations in hazardous gas or flooded environments; a four-channel video link and two-way audio to ensure located survivors can communicate with operators; and an MSHA-approved multi-gas sensor to monitor air quality.

42 ENGINEERING↗

The Spectroscopic Data Processing Pipeline for the Dark Energy Spectroscopic Instrument

Abstract We describe the spectroscopic data processing pipeline of the Dark Energy Spectroscopic Instrument (DESI), which is conducting a redshift survey of about 40 million galaxies and quasars using a purpose-built instrument on the 4 m Mayall Telescope at Kitt Peak National Observatory. The main goal of DESI is to measure with unprecedented precision the expansion history of the universe with the baryon acoustic oscillation technique and the growth rate of structure with redshift space distortions. Ten spectrographs with three cameras each disperse the light from 5000 fibers onto 30 CCDs, covering the near-UV to near-infrared (3600–9800 Å) with a spectral resolution ranging from 2000 to 5000. The DESI data pipeline generates wavelength- and flux-calibrated spectra of all the targets, along with spectroscopic classifications and redshift measurements. Fully processed data from each night are typically available to the DESI collaboration the following morning. We give details about the pipeline’s algorithms, and provide performance results on the stability of the optics, the quality of the sky background subtraction, and the precision and accuracy of the instrumental calibration. This pipeline has been used to process the DESI Survey Validation data set, and has exceeded the project’s requirements for redshift performance, with high efficiency and a purity greater than 99% for all target classes.

79 ASTRONOMY AND ASTROPHYSICS↗

Polarization Angle Swings in Blazars Detected in the Millimeter-wave with the South Pole Telescope

We present the first systematic search for electric vector position angle (EVPA) swings in the millimeter-wave (mm-wave) emission of blazars, using five years of observations from the South Pole Telescope SPT-3G camera at 95 and 150 GHz, and investigate their connection to gamma-ray flares. Of the 168 bright sources in the ~1500 square degrees SPT-3G Main Field, eight have sufficient polarization signal-to-noise for reliable EVPA measurement, four of which have continuous Fermi LAT gamma-ray detections. We detect EVPA swings in all four gamma-ray-active blazars and in none of the remaining four, consistent with the established connection between EVPA swings and high-energy emission seen at optical wavelengths. The observed swing amplitudes and rotation rates are smaller than those found in optical studies, consistent with mm-wave EVPA variability being slower than at shorter wavelengths. Random walk simulations of the polarization angle using a multi-cell model fail to reproduce both the number, amplitude, and duration of the observed swings, suggesting that this mechanism is insufficient to explain the observed swing population. Analysis of EVPA variability on one-week timescales is consistent with the anti-correlation between polarization degree and EVPA rotation rate previously observed at optical wavelengths. Of the 14 detected swings, eight are within 30 days of a gamma-ray flare. While many individual swing-flare associations are found to have a very low probability of happening by chance, the full ensembles of 95 and 150 GHz swing time lags with respect to gamma-ray flares are found to be consistent with random coincidence.

Simpson, A. [Chicago U., Astron. Astrophys. Ctr.; ↗

Alpha-Imaging Detector System Development for Large Area Monitoring

Effective management and disposal of legacy nuclear waste are essential for ensuring safe work environments and minimizing environmental impacts. Monitoring airborne actinide contamination is particularly critical due to the high internal dose potential of alpha-emitting radionuclides. Traditional continuous air monitoring systems (CAMs) used in the industry are limited in the volume of air they can sample, potentially leading to inaccurate radiation detection over large areas. For example, in 2018, elevated levels of airborne Plutonium-239 were detected beyond the controlled areas of the Hanford Plutonium Finishing Plant, highlighting the potential risks to both plant workers and nearby residents. To address these challenges, high-efficiency particulate absorbing (HEPA) air purifiers can enhance air flow by up to 1.5 orders of magnitude, thereby increasing monitoring efficiency and providing a cost-effective solution for large-area surveillance. To quantify the activities of alpha-emitting radionuclides on HEPA filters, the Savannah River National Laboratory is developing an advanced alpha-imaging detection system. This system includes scintillating materials combined with a digital scientific camera. A significant concern in operating such a large-area airborne monitoring system is the handling of HEPA filters, which may be contaminated with radioactive particles. To mitigate these hazards, it is crucial to ensure that any contamination is securely fixed onto the filters. Efforts have been made to optimize the sensitivity of scintillator-epoxy composites and apply them to HEPA filters. These materials were characterized using fluoroscence spectroscopy. These techniques confirmed the purity of the raw materials, the dispersion of scintillators in the epoxy matrix, and the stability of their optical and structural properties post-modification. The optimal scintillator-epoxy composite was selected for use on alpha-spiked HEPA filters to evaluate the efficiency of the sprayer. HEPA filters, embedded with alpha particles collected by an air purifier deployed in an airborne radiation area, have been tested to assess detection efficiency. Future work will focus on employing multiple imaging sensors simultaneously to enhance sensitivity across different regions of the HEPA filter.

Pham, Phuong [Savannah River National Laboratory (↗

One-dimensional air temperature measurements by air resonance enhanced multiphoton Ionization thermometry (ART)

In this work, a detailed calibration study is performed to establish non-intrusive one-dimensional (1D) rovibrational temperature measurements in unseeded air, based on air resonance enhanced multiphoton ionization thermometry (ART). ART is generated by REMPI (resonance enhanced multi-photon ionization) of molecular oxygen and subsequent avalanche ionization of molecular nitrogen in a single laser pulse. ART signal, the fluorescence from the first negative band of molecular nitrogen, is directly proportional to the 2-photon transition of molecular oxygen C 3 Π (v = 2) ← X 3 Σ (v’=0), which is used to determine temperature. Experimentally, hyperfine structures of the O 2 rotational branches with high temperature sensitivity are selectively excited through a frequency-doubled dye laser. Electron-avalanche ionization of N 2 results in the fluorescence emissions from the first negative bands of N 2 + near 390, 425, and 430nm, which are captured as a 1D line by a gated intensified camera. Post processing of the N 2 + fluorescence yields a 1D thermometry line that is representative of the air temperature. It is demonstrated that the technique provides ART fluorescence of ∼5cm in length in the unseeded air, presenting an attractive thermometry solution for high-speed wind tunnels and other ground test facilities.

42 ENGINEERING↗

Development of an MKID frequency-to-pixel LED mapper for SPT-3G+

SPT-3G+ is the next-generation camera for the South Pole Telescope (SPT). SPT is designed to measure the cosmic microwave background (CMB) and the mm/sub-mm sky. The planned focal plane consists of 34,000 microwave kinetic inductance detectors (MKIDs), divided among three observing bands centered at 220, 285, and 345 GHz. Each readout line is designed to measure 800 MKIDs over a 500 MHz bandwidth, which places stringent constraints on the accuracy of the frequency placement required to limit resonator collisions that reduce the overall detector yield. To meet this constraint, we are developing a two-step process that first optically maps the resonance to a physical pixel location, and then next trims the interdigitated capacitor (IDC) to adjust the resonator frequency. We present a cryogenic LED apparatus operable at 300 mK for the optical illumination of SPT-3G+ detector arrays. We demonstrate integration of the LED controls with the GHz readout electronics (RF-ICE) to take data on an array of prototype SPT-3G+ detectors. We show that this technique is useful for characterizing defects in the resonator frequency across the detector array and will allow for improvements in the detector yield.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving galaxy cluster selection with the outskirt stellar mass of galaxies

The number density and redshift evolution of optically selected galaxy clusters offer an independent measurement of the amplitude of matter fluctuations, 𝑆 8 . However, recent results have shown that clusters chosen by the redMaPPer algorithm show richness-dependent biases that affect the weak lensing signals and number densities of clusters, increasing uncertainty in the cluster mass calibration and reducing their constraining power. Here, in this work, we evaluate an alternative cluster proxy, outskirt stellar mass, 𝑀 out , defined as the total stellar mass within a [50, 100] kpc envelope centered on a massive galaxy. This proxy exhibits scatter comparable to redMaPPer richness, 𝜆, but is less likely to be subject to projection effects. We compare the Dark Energy Survey Year 3 redMaPPer cluster catalog with a 𝑀 out selected cluster sample from the Hyper-Suprime Camera survey. We use weak lensing measurements to quantify and compare the scatter of 𝑀 out and 𝜆 with halo mass. Our results show 𝑀 out has a scatter consistent with 𝜆, with a similar halo mass dependence, and that both proxies contain unique information about the underlying halo mass. We find 𝜆-selected samples introduce features into the measured Δ⁢Σ signal that are not well fit by a log-normal scatter only model, absent in 𝑀 out selected samples. Our findings suggest that 𝑀 out offers an alternative for cluster selection with more easily calibrated selection biases, at least at the generally lower richnesses probed here. Combining both proxies may yield a mass proxy with a lower scatter and more tractable selection biases, enabling the use of lower mass clusters in cosmology. Finally, we find the scatter and slope in the 𝜆 −𝑀 out scaling relation to be 0.49 ±0.02 and 0.38 ±0.09.

79 ASTRONOMY AND ASTROPHYSICS↗

Optical-pump–terahertz-probe spectroscopy in high magnetic fields with kHz single-shot detection

We demonstrate optical pump–THz probe (OPTP) spectroscopy with a variable external magnetic field (0–9 T), in which the time-dependent THz signal is measured by echelon-based single-shot detection at a repetition rate of 1 kHz. The method reduces data acquisition times by more than an order of magnitude compared to conventional electro-optic sampling using a scanning delay stage. The approach illustrates the wide applicability of the single-shot measurement approach to non-equilibrium systems that are studied through OPTP spectroscopy, especially in cases where parameters such as magnetic field strength (B) or other experimental parameters are varied. We demonstrate the capabilities of our measurement by performing cyclotron resonance experiments in bulk silicon, where we observe B-field-dependent carrier relaxation and distinct relaxation rates for different carrier types. We use a pair of economical linear array detectors to measure 500 time points on each shot, offering an equivalent performance to camera-based detection with possibilities for higher repetition rates.

Instruments & Instrumentation↗

Data for "In vitro and in vivo NIR Fluorescence Lifetime Imaging with a time-gated SPAD camera"

Near-infrared (NIR) fluorescence lifetime imaging (FLI) provides a unique contrast mechanism to monitor biological parameters and molecular events in vivo. Single-photon avalanche diode (SPAD) cameras have been recently demonstrated in FLI microscopy (FLIM) applications, but their suitability for in vivo macroscopic FLI (MFLI) in deep tissues remains to be demonstrated. Herein, we report in vivo NIR MFLI measurement with SwissSPAD2, a large time-gated SPAD camera. We first benchmark its performance in well-controlled in vitro experiments, ranging from monitoring environmental effects on fluorescence lifetime, to quantifying Förster resonant energy transfer (FRET) between dyes. Next, we use it for in vivo studies of target-drug engagement in live and intact tumor xenografts using FRET. Information obtained with SwissSPAD2 was successfully compared to that obtained with a gated intensified charge-coupled device (ICCD) camera, using two different approaches. Our results demonstrate that SPAD cameras offer a powerful technology for in vivo preclinical applications in the NIR window.

2DG↗

Autonomous Navigation and Control of UGVs' in Nuclear Power Plants - 20381

The purpose of the husky A200 ground robot is to autonomously navigate through the places where it is very hazardous for human beings to reach and operate, like nuclear power plants, chemical industries. The aim is to navigate the ground robot autonomously with an Arm mounted on the robot along with the different sensors as camera, and Lidar. The autonomous motion of the robot is controlled by the controller which uses path planner for trajectory generation of the robot. The mission planner uses the current position of the husky A200, given the way points of the initial and the destination it would extract a best possible route based on the current events provided using GMapping. The global reference frame is used for planning the way points. Creating the appropriate path and the actions required to follow the path are given by the motion planner. The motion planner depends on the active sensor data such as obstacles, lanes, based on the sensor data feasible path is generated. Feasibility of the path is determined by the dynamics of the husky and a series of points generated with certain velocity and acceleration profile. The controller adjusts the lateral, longitudinal and yaw motion of the husky to command the behaviors. The kinematic model is developed for kinematic motion of the husky and the dynamic model is developed for transient and steady state characteristics. The images and other type of data captured by the camera are processed through the computational framework used to build machine learning models. TensorFlow will be used for deep learning and to identify and classify different objects around the husky. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ARES. III. Unveiling the Two Faces of KELT-7 b with HST WFC3

We present the analysis of the hot-Jupiter KELT-7 b using transmission and emission spectroscopy from the Hubble Space Telescope, both taken with the Wide Field Camera 3. Our study uncovers a rich transmission spectrum that is consistent with a cloud-free atmosphere and suggests the presence of H{sub 2}O and H{sup −}. In contrast, the extracted emission spectrum does not contain strong absorption features and, although it is not consistent with a simple blackbody, it can be explained by a varying temperature–pressure profile, collision induced absorption, and H{sup −}. KELT-7 b had also been studied with other space-based instruments and we explore the effects of introducing these additional data sets. Further observations with Hubble, or the next generation of space-based telescopes, are needed to allow for the optical opacity source in transmission to be confirmed and for molecular features to be disentangled in emission.

79 ASTRONOMY AND ASTROPHYSICS↗