Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “operational controller loops”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

The Development of Cockpit Display and Alerting Concepts for Interval Management (IM) in a Near-Term Environment

The National Aeronautics and Space Administration (NASA) Langley Research Center (LaRC) Interval Management (IM) research team has conducted a wide spectrum of work in the recent past, ranging from development and testing of the concept, procedures, and algorithm. This document focuses on the research and evaluation of the IM pilot interfaces, cockpit displays, indications, and alerting concepts for conducting IM spacing operations. The research team incorporated knowledge of human factors research, industry standards for cockpit design, and cockpit design philosophies to develop innovative displays for conducting these spacing operations. The research team also conducted a series of human-in-the-loop (HITL) experiments with commercial pilots and air traffic controllers, in as realistic a high-density arrival operation environment as could be simulated, to evaluate the spacing guidance display features and interface requirements needed to conduct spacing operations.

Baxley, Brian T.↗

Modular Isolated Soft-Switching Medium Voltage String Inverter for Large-Scale PV Farm

This paper presents a single-stage modular isolated soft-switching medium voltage string inverter (MVSI) with tri-port configuration to interconnect PV and storage to medium voltage (MV) grid. The modular MVSI provides advanced functionalities such as energy storage elements integration without additional converters, connection to MV grid resulting in lower distribution losses in the PV farm, high-frequency galvanic isolation, independent control of PV, storage and grid power, high modularity and scalability. The topology of the MVSI, operation principle and model-predictive priority-switching (MPPS) control to achieve fast dynamic balancing across stacked modules are discussed. The independent power control is validated in PLECS simulation and the operation of stacked MVSI with MPPS control is verified through Hardware-in-the-loop (HIL) simulation. Here, the hardware prototype of 25 kVA MVSI building block is developed. 18 kW experimental results of single building block verifying tri-ports operation and 20 kW experimental results of two modules stacked operation are presented. A clean sinusoidal waveform with negligibly low THD in both tests is obtained. A low dv/dt of <; 1kV/us and soft-switching are achieved.

30 DIRECT ENERGY CONVERSION↗

HAT m:N Activity Overview

Since 2020, researchers from the Human Autonomy Teaming (HAT) Laboratory at NASA Ames Research Center have conducted human-in-the-loop (HITL) simulation research to study a new control paradigm for operations involving multiple remotely piloted aircraft systems (RPAS). Colloquially referred to as "m:N," this paradigm is characterized by multiple operators collaboratively controlling multiple vehicles between them. The m:N name expresses a ratio whereby m is the number of operators and N is the number of vehicles shared between them. In this presentation, HAT Lab researchers provide a high-level overview of the m:N studies that have been performed to-date. These include a study of the m:N concept of operations (CONOPS) and the attending roles and responsibilities ("ConOps/R&R Sim"), a study focused on contingency management involving dynamic, inter-operator transfers of vehicles ("Handoff Sim"), and a study examining the effects of pilot-ATC communication systems on workload ("UAM Comms Sim"). A selection of key results are provided. The presentation concludes with a brief discussion of planned research into m:N operations.

m:N↗

Soft Real-Time PID Control on a VME Computer

microPID (uPID) is a computer program for real-time proportional + integral + derivative (PID) control of a translation stage in a Fourier-transform ultraviolet spectrometer. microPID implements a PID control loop over a position profile at sampling rate of 8 kHz (sampling period 125microseconds). The software runs in a strippeddown Linux operating system on a VersaModule Eurocard (VME) computer operating in real-time priority queue using an embedded controller, a 16-bit digital-to-analog converter (D/A) board, and a laser-positioning board (LPB). microPID consists of three main parts: (1) VME device-driver routines, (2) software that administers a custom protocol for serial communication with a control computer, and (3) a loop section that obtains the current position from an LPB-driver routine, calculates the ideal position from the profile, and calculates a new voltage command by use of an embedded PID routine all within each sampling period. The voltage command is sent to the D/A board to control the stage. microPID uses special kernel headers to obtain microsecond timing resolution. Inasmuch as microPID implements a single-threaded process and all other processes are disabled, the Linux operating system acts as a soft real-time system.

Karayan, Vahag↗

Differing Air Traffic Controller Responses to Similar Trajectory Prediction Errors: An Interrupted Time-Series Analysis of Controller Behavior

A Human-In-The-Loop simulation was conducted in January of 2013 in the Airspace Operations Laboratory at NASAs Ames Research Center. The simulation airspace included two en route sectors feeding the northwest corner of Atlantas Terminal Radar Approach Control. The focus of this paper is on how uncertainties in the studys trajectory predictions impacted the controllers ability to perform their duties. Of particular interest is how the controllers interacted with the delay information displayed in the meter list and data block while managing the arrival flows. Due to wind forecasts with 20-knot over-predictions and 20-knot under-predictions, delay value computations included errors of similar magnitude, albeit in opposite directions. However, when performing their duties in the presence of these errors, did the controllers issue clearances of similar magnitude, albeit in opposite directions?

human-automation interaction↗

Neural net controller for inlet pressure control of rocket engine testing

Many dynamic systems operate in select operating regions, each exhibiting characteristic modes of behavior. It is traditional to employ standard adjustable gain proportional-integral-derivative (PID) loops in such systems where no apriori model information is available. However, for controlling inlet pressure for rocket engine testing, problems in fine tuning, disturbance accommodation, and control gains for new profile operating regions (for research and development) are typically encountered. Because of the capability of capturing I/O peculiarities, using NETS, a back propagation trained neural network is specified. For select operating regions, the neural network controller is simulated to be as robust as the PID controller. For a comparative analysis, the higher order moment neural array (HOMNA) method is used to specify a second neural controller by extracting critical exemplars from the I/O data set. Furthermore, using the critical exemplars from the HOMNA method, a third neural controller is developed using NETS back propagation algorithm. All controllers are benchmarked against each other.

Trevino, Luis C.↗

A comparison of two multi-variable integrator windup protection schemes

Two methods are examined for limit and integrator wind-up protection for multi-input, multi-output linear controllers subject to actuator constraints. The methods begin with an existing linear controller that satisfies the specifications for the nominal, small perturbation, linear model of the plant. The controllers are formulated to include an additional contribution to the state derivative calculations. The first method to be examined is the multi-variable version of the single-input, single-output, high gain, Conventional Anti-Windup (CAW) scheme. Except for the actuator limits, the CAW scheme is linear. The second scheme to be examined, denoted the Modified Anti-Windup (MAW) scheme, uses a scalar to modify the magnitude of the controller output vector while maintaining the vector direction. The calculation of the scalar modifier is a nonlinear function of the controller outputs and the actuator limits. In both cases the constrained actuator is tracked. These two integrator windup protection methods are demonstrated on a turbofan engine control system with five measurements, four control variables, and four actuators. The closed-loop responses of the two schemes are compared and contrasted during limit operation. The issue of maintaining the direction of the controller output vector using the Modified Anti-Windup scheme is discussed and the advantages and disadvantages of both of the IWP methods are presented.

Mattern, Duane↗

Coolant Leak from ISS External Active Thermal Control System (EATCS) – An Examination of Most Probable

The Port (P1) and Starboard (S1) External Active Thermal Control Systems (EATCS) are single phase, mechanically pumped ammonia loops that operate independently to cool the majority of the hardware and payloads onboard the International Space Station (ISS). A slow ammonia leak was detected using pressure and quantity telemetry five years after the P1 EATCS was activated. The leak gradually accelerated to a rate that locating and isolating the leak became imperative to maintain cooling capability. Partial pressure measurements from the Robotic External Leak Locator (RELL) scan surveys narrowed the search to the supply and return jumpers connecting one of three radiators to the system. Subsequently, the ISS crew performed high definition video surveys during an Extravehicular Activity (EVA), or spacewalk, and ammonia flakes were observed projecting from the jumpers. Thus, the ground teams were confident that the culprit for the ammonia leak was the jumpers. The ammonia leak stopped after ground teams remotely isolated and vented those jumpers and associated radiator. Both jumpers were removed and returned to the ground, and a root cause investigation was conducted. A calibrated leak test determined the bulk of the ammonia leaked through a pair of seals in a Quick Disconnect (QD), or connector, on one end of the return jumper. The return jumper QD was dissected, visually inspected, chemically tested and evaluated. The results indicated the most probable cause of the accelerating ammonia leak was due to defective seals, plating delamination underneath the seals, and on-orbit thermal cycles exacerbating the delamination. Both jumpers were refurbished, relaunched to the ISS, and scheduled to be reinstalled during an EVA in 2022. It appeared the issue was unique, but recently the S1 EATCS is showing signs of an accelerating ammonia leak, and RELL scans narrowed the source to a similar pair of radiator jumpers.

Thermal Control↗

Coolant Leak from ISS External Active Thermal Control System (EATCS) – An Examination of Most Probable

The Port (P1) and Starboard (S1) External Active Thermal Control Systems (EATCS) are single phase, mechanically pumped ammonia loops that operate independently to cool majority of the hardware and payloads onboard the International Space Station (ISS). A slow ammonia leak was detected using pressure and quantity telemetry five years after the P1 EATCS was activated. The leak gradually accelerated to a rate that locating and isolating the leak became imperative to maintain cooling capability. Partial pressure measurements from the Robotic External Leak Locator (RELL) scan surveys narrowed the search to the supply and return jumpers connecting one of three radiators to the system. Subsequently, the ISS crew performed high definition video surveys during an Extravehicular Activity (EVA), or spacewalk, and ammonia flakes were observed projecting from the jumpers. Thus, the ground teams were confident that the culprit of the ammonia leak were the jumpers. The ammonia leak stopped after ground teams remotely isolated and vented those jumpers and associated radiator. Both jumpers were removed and returned to the ground, and a root cause investigation was conducted. A calibrated leak test determined the bulk of the ammonia leaked through a pair of seals in a Quick Disconnect (QD), or connector, on one end of the return jumper. The return jumper QD was dissected, visually inspected, chemically tested and evaluated. The results indicated the most probable cause of the accelerating ammonia leak was due to defective seals, plating delamination underneath the seals, and on-orbit thermal cycles exacerbating the delamination. Both jumpers were refurbished, relaunched to the ISS, and scheduled to be reinstalled during an EVA in 2022. It appeared the issue was unique, but recently the S1 EATCS is showing signs of an accelerating ammonia leak, and RELL scans narrowed the source to a similar pair of radiator jumpers.

Thermal Control↗

An Integrated Tool Suite for En Route Radar Controllers in NextGen

This paper describes recent human-in-the-loop research in the Airspace Operations Laboratory at the NASA Ames Research Center focusing on en route air traffic management with advanced trajectory planning tools and increased levels of human-automation cooperation. The decision support tools were exercised in a simulation of seven contiguous high-altitude sectors. Preliminary data suggests the controllers were able to manage higher amounts of traffic as compared to today, while maintaining acceptable levels of workload.

Mercer, Joey↗

A description of the active and passive sidewall-boundary-layer removal systems of the 0.3-meter transonic cryogenic tunnel

Results are presented for an operational checkout and shakedown of the active sidewall-boundary-layer removal system newly installed in the Langley 0.3-meter Transonic Cryogenic Tunnel (0.3-m TCT). Prior to the installation of this active removal system, the sidewall-boundary layer was removed passively by exhausting directly to the atmosphere (i.e., no reinjection). With the active removal system using the reinjection compressor, the removal capability is greatly expanded to cover the entire operating envelope of the 0.3-m TCT. Details of the active removal system are presented including the compressor reinjection circuit, the compressor pressure ratio/surge control, and the compressor recirculation loop. The control logic and features of the compressor surge control are explained. Initial tests covering critical operating conditions show mass flow removal rates of about 5 percent at lower Mach numbers can be obtained with the active system. Measured performance characteristics of the compressor are presented. As part of the validation of the active system, limited airfoil tests were made using the new system.

Johnson, C. B.↗

Virtual Cable Impedance based Load Sharing in a Microgrid for Parallel Connected Grid Forming Converters

This paper presents a novel approach to power sharing between direct connected grid-forming converters, utilizing virtual cable impedance and droop-based outer loop control. To enhance stability, resistive droop is implemented, while virtual cable impedance with non-zero resistive and inductive components ensures improved power sharing. The inner loop controller employs a Lyapunov energy function to achieve superior dynamic performance. The proposed control architecture is validated through comprehensive modeling and real-time processor-in-the-loop simulations, demonstrating its robustness and efficiency under various operating conditions. The results highlight the potential of this control strategy to improve the reliability and efficiency of renewable energy systems. Additionally, a comparative analysis with traditional methods underscores the advantages of the proposed approach in terms of stability and performance. The proposed control architecture offers a scalable and flexible solution for grid-forming converters, enabling seamless integration of renewable energy sources. Its robustness and adaptability make it an attractive solution for real-world applications. Furthermore, the approach can be extended to other power electronic systems, enhancing overall system performance and efficiency. By providing a reliable and efficient control strategy, this paper contributes to the advancement of renewable energy systems and their adoption in the energy sector. The proposed control strategy has far-reaching implications for the widespread adoption of renewable energy sources, enabling a more sustainable and efficient energy future. The overall system is modeled in MATLAB/Simulink and PLECS software domain.

grid forming converters (GFM)↗

Duty-Cycle Predictive Control of Quasi-Z-Source Modular Cascaded Converter Based Photovoltaic Power System

A duty-cycle predictive control is proposed for dc grid integration of front-end isolated quasi-Z-source modular cascaded converter (qZS-MCC) photovoltaic (PV) power system. The post-stage qZS half-bridge dc-dc converter deals with PV maximum power point tracking, dc grid integration, and dc-link voltage balance; whereas, the front-end isolation converters operate at a constant duty cycle of 50%. Thus, it saves control hardware resources while overcoming challenges from PV-panel voltage variations and dc-bus voltage limit. The proposed control uses the derived circuit model to predict the global active-state duty cycle for grid-connected current control and predict the shoot-through duty cycles for dc-link voltage balance, achieving a fast and accurate tracking target. The proposed control method has advantages of: i) eliminating weighting factors that exist in conventional model predictive control (MPC), ii) no sophisticated loop parameters design that exists in proportional-integral (PI) control, iii) operating at constant switching frequency that is different from the conventional MPC with variable switching frequency. Simulation and experimental tests are carried out to verify the effectiveness of the proposed control method and compare with the PI-based control system.

42 ENGINEERING↗

Building ControlScore: General Service Administration Office Building Deployment

Improvements to building control systems can lead to energy savings and increased occupant comfort. In an optimized system, process variables such as air temperature will closely follow their desired setpoints and avoid excess energy use. Typically, experts must manually inspect individual control loops to identify poor performance and opportunities for improvement. However, this approach is difficult in modern buildings that have a prohibitively large number of controllers. To address this issue, Pacific Northwest National Laboratory (PNNL) created the ControlScore concept, which takes operating data from the many controllers within a building and generates standardized scores for each loop on a scale of 0 to 10 (a score of 0 indicates poor control, a score of 10 indicates good control). PNNL applied the Building ControlScore application to all available data from a General Services Administration office building within the period of January 1, 2023, to March 9, 2023. The building scored a 4.7 overall, with all 74 of the building’s loops fitting a roughly normal distribution centered around 5. These results indicate that the analyzed systems have below-average performance with room for improvement, especially in the poorly scored systems. Airflow loops tended to have much lower scores than zone temperature loops. The lowest and highest performing systems in the building section were identified, as were all loops with a score less than 1. While the ControlScore identifies loops and systems that aren’t meeting their designated setpoints, it does not indicate the cause of those issues. For example, consider a supply air terminal unit’s airflow loop that received a low score due to it delivering less air than specified by the setpoint. The lower-than-desired airflow could be due to equipment limitations (e.g., the terminal unit or duct serving is too small to accommodate that airflow), malfunctioning equipment (e.g., a stuck damper or bad sensor), or something else entirely. The ControlScore does not diagnose problems it simply identifies the symptoms that can be explored and addressed by building operators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Testing of the Geoscience Laser Altimeter System (GLAS) Prototype Loop Heat Pipe

This paper describes the testing of the prototype loop heat pipe (LHP) for the Geoscience Laser Altimeter System (GLAS). The primary objective of the test program was to verify the loop's heat transport and temperature control capabilities under conditions pertinent to GLAS applications. Specifically, the LHP had to demonstrate a heat transport capability of 100 W, with the operating temperature maintained within +/-2K while the condenser sink was subjected to a temperature change between 273K and 283K. Test results showed that this loop heat pipe was more than capable of transporting the required heat load and that the operating temperature could be maintained within +/-2K. However, this particular integrated evaporator-compensation chamber design resulted in an exchange of energy between the two that affected the overall operation of the system. One effect was the high temperature the LHP was required to reach before nucleation would begin due to inability to control liquid distribution during ground testing. Another effect was that the loop had a low power start-up limitation of approximately 25 W. These Issues may be a concern for other applications, although it is not expected that they will cause problems for GLAS under micro-gravity conditions.

Douglas, Donya↗

Frequency modulated cutaneous orientation feedback from artificial arms

A model of the human arm, emphasizing the neuromuscular mechanisms of feedback control, has been constructed. The various parameters and functions of physiological receptors in the feedback section have been classified into an automated category that can be incorporated in the prosthesis servo loop, and into a sensory category that should be communicated to the operator if control and dynamic performance are to be optimized. A scheme for simultaneous display of two such sensory parameters, i.e., fingertip pressure and elbow position, has been developed, implemented and evaluated. The neurophysiological mechanism of such displays, and the feasibility of sensory transformation, is discussed in this paper.

Solomonow, M.↗

Test and validation for robot arm control dynamics simulation

The Flight Telerobotic Servicer (FTS) program will require an ability to develop, in a cost effective manner, many simulation models for design, analysis, performance evaluation, and crew training. Computational speed and the degree of modeling fidelity associated with each simulation must be commensurate with problem objectives. To demonstrate evolving state-of-the-art general purpose multibody modeling capabilities, to validate these by laboratory testing, and to expose their modeling shortcomings, two focus problems at the opposite ends of the simulation spectrum are defined: (1) Coarse Acquisition Control Dynamics. Create a real time man-in-the-control-loop simulator. Provide animated graphical display of robot arm dynamics and tactile feedback sufficient for cueing the operator. Interface simulator software with human operated tactile feedback controller; i.e., the Kraft mini-master. (2) Fine, Precision Mode Control Dynamics. Create a high speed, high fidelity simulation model for the design, analysis, and performance evaluation of autonomous 7 degree-of-freedom (DOF) trajectory control algorithms. This model must contain detail dynamic models for all significant dynamics elements within the robot arm, such as joint drive mechanisms.

Yae, K. Harold↗

Integrated testing of the Thales LPT9510 pulse tube cooler and the iris LCCE electronics

The Jet Propulsion Laboratory (JPL) has identified the Thales LPT9510 pulse tube cryocooler as a candidate low cost cryocooler to provide active cooling on future cost-capped scientific missions. The commercially available cooler can provide refrigeration in excess of 2 W at 100K for 60W of power. JPL purchased the LPT9510 cooler for thermal and dynamic performance characterization, and has initiated the flight qualification of the existing cooler design to satisfy near-term JPL needs for this cooler. The LPT9510 has been thermally tested over the heat reject temperature range of 0C to +40C during characterization testing. The cooler was placed on a force dynamometer to measure the selfgenerated vibration of the cooler. Iris Technology has provided JPL with a brass board version of the Low Cost Cryocooler Electronics (LCCE) to drive the Thales cooler during characterization testing. The LCCE provides precision closed-loop temperature control and embodies extensive protection circuitry for handling and operational robustness; other features such as exported vibration mitigation and low frequency input current filtering are envisioned as options that future flight versions may or may not include based upon the mission requirements. JPL has also chosen to partner with Iris Technology for the development of electronics suitable for future flight applications. Iris Technology is building a set of radiation-hard, flight-design electronics to deliver to the Air Force Research Laboratory (AFRL). Test results of the thermal, dynamic and EMC testing of the integrated Thales LPT9510 cooler and Iris LCCE electronics is presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗