Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “operating costs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Joining Study for Formed Plate Heat Exchangers (Final Report)

Plate heat exchangers (PHEs) have been used in numerous industrial applications, such as HVAC systems, power generation, transportation and manufacturing. The performance of plate heat exchangers is frequently undermined by corrosion, fouling, and scaling. These phenomena not only diminish heat transfer efficiency but also lead to increased operational costs, maintenance demands, and reduced equipment lifespan. In this project, the team addressed the widespread challenges of corrosion, fouling, and scaling, and explored alternative material solutions. While commonly used materials like stainless steel and titanium offer notable benefits, they can still experience corrosion under certain operating conditions. The advancement of new materials and surface engineering technologies, such as advanced coating, ceramics, composites materials, and high entropy alloys are promising for can help solve these issues, enable longer lifetime and high performance of plate heat exchangers.

36 MATERIALS SCIENCE↗

Unalakleet Microgrid Optimization for Tribal Community Resilience

The Unalakleet Microgrid Optimization Project aimed to strengthen the reliability and efficiency of the isolated electric power system that serves the Tribal community of Unalakleet, Alaska. The community relies entirely on a local wind-diesel microgrid, consisting of four 475 kW diesel generators and six 100 kW wind turbines, to provide electricity to approximately 745 residents and Tribal facilities. Because Unalakleet is not on a road system and is located nearly 400 miles from the nearest major power grid, maintaining a resilient and efficient local energy system is critical. The scope of this project included upgrading a portion of the transmission line between the wind farm and the power plant to increase voltage and reduce line losses, along with modernizing the Supervisory Control and Data Acquisition (SCADA) system to improve monitoring, control, and data management of the power system. These upgrades were designed to increase wind energy utilization, reduce diesel fuel consumption by tens of thousands of gallons annually, and improve overall grid stability. By allowing more of the community’s electricity to be supplied by local renewable wind resources, the project was designed to lower operating costs, reduce dependence on imported fuel, and strengthen the long-term resilience of the power system. These improvements represent an important step toward the community’s long-term energy vision of expanding renewable generation, incorporating energy storage, and eventually achieving “diesels-off” operation, where essential Tribal loads are powered primarily by local renewable resources.

17 WIND ENERGY↗

Improved Particle Heat Transfer by way of Bimodal Particle Distributions for High Temperature Solar Thermal Energy

High temperature solar thermal facilities are looking to increase operating temperatures through novel heat transfer media, one such being solid particles. These particles operating at high temperatures will require transferring their thermal energy into another working fluid like supercritical carbon dioxide which can be used in advanced power cycles. Achieving high heat transfer between the particles and supercritical carbon dioxide is essential to high efficiency and low-cost operation. Therefore, optimizing the thermal conductivity of these particles is one potential way to ensure high performance. Traditionally, unimodal particle distributions have been employed in high temperature particle solar power plants. However, ambient temperature testing of bimodal particle distributions has revealed a superior thermal conductivity when compared to its unimodal counterpart at the same temperature. This data was obtained by certified, off-the-shelf instruments that can effectively simulate the conditions a particle would be exposed to in a high temperature solar thermal system. Data obtained in this way suggests that the increased thermal conductively imputed by a bimodal particle distribution is significant at working temperatures in solar facilities. Furthermore, the thermal conductivity of these bimodal particle distributions peaks when the best combination of large and small particles is applied. At high temperatures, binary particle distributions are compared to monodispersed distributions of larger particles where heat transfer is more prolific due to the increased surface radiation. Various thermal conductivity, porosity and heat exchanger models are explored in conjunction with data acquired up to 700 C.

Stout, Dallin (ORCID:0009000294586091)↗

Process design tools and techno-economic analysis for capacitive deionization

Capacitive deionization (CDI) devices use cyclical electrosorption on porous electrode surfaces to achieve water desalination. Process modeling and design of CDI systems requires accurate treatment of the coupling among input electrical forcing, input flow rates, and system responses including salt removal dynamics, water recovery, energy storage, and dissipation. Techno-economic analyses of CDI further require a method to calculate and compare between a produced commodity (e.g. desalted water) versus capital and operational costs of the system. In this work, we demonstrate a new modeling and analysis tool for CDI developed as an installable Matlab program that allows direct numerical simulation of CDI dynamics and calculation of key performance and cost parameters. The program is provided for free and is used to run open-source Simulink models. The Simulink environment sends information to the program and allows for a drag and drop design space where users can connect CDI cells to relevant periphery blocks such as grid energy, battery, solar panel, waste disposal, and maintenance/labor cost streams. The program allows for simulation of arbitrary current forcing and arbitrary flow rate forcing of one or more CDI cells. We employ validated well-mixed reactor formulations together with a non-linear circuit model formulation that can accommodate a variety of electric double layer sub-models (e.g. for charge efficiency). The program includes a graphical user interface (GUI) to specify CDI plant parameters, specify operating conditions, run individual tests or parameter batch-mode simulations, and plot relevant results. The techno-economic models convert among dimensional streams of species (e.g. feed, desalted water, and brine), energy, and cost and enable a variety of economic estimates including levelized water costs.

42 ENGINEERING↗

Development of a Geothermal Module in reV: Quantifying the Geothermal Potential while Accounting for the Geospatial Intersection of the Grid Infrastructure and Land Use Characteristics

The Renewable Energy Potential (reV) model is a geospatial platform for estimating technical potential and developing renewable energy supply curves, initially developed for wind and solar technologies. The model evaluates deployment constraints, considering land use, environmental, and cultural factors, and estimates the distance to existing grid features to connect future plants (Maclaurin et al., 2021). A pressing deficiency in the reV model, however, is representation of geothermal electricity generation technologies. To address this gap, we developed a novel geothermal generation module for reV that allows for representation and analysis at the same level of detail as other renewable technologies. This paper describes our process for evaluating data sources for the modeling, and presents five preliminary reV geothermal results. More specifically, we present two sets of resource data that represent upper and lower bounds for geothermal potential. We then present several sensitivity runs using the upper bound resource data; the results are encouraging that levelized cost of electricity (LCOE) can be reduced by optimizing the location and estimated capacity of the spatially diverse geothermal resource while considering the distance to existing grid infrastructure. Our preliminary supply curves and levelized cost of electricity (LCOE) results should be considered with care due to the highly uncertainty in geothermal resource potential data. We present median LCOE values for the conterminous U.S. for five scenarios: four hydrothermal (3.5km depth) and one EGS (4.5km depth). The capital and operating costs for each respective technology are modeled. We also compare results using two different resource data sources.

exclusions↗

Development of a Geothermal Module in reV: Quantifying the Geothermal Potential While Accounting for the Geospatial Intersection of the Grid Infrastructure and Land Use Characteristics: Preprint

The Renewable Energy Potential (reV) model is a geospatial platform for estimating technical potential and developing renewable energy supply curves, initially developed for wind and solar technologies. The model evaluates deployment constraints, considering land use, environmental, and cultural factors, and estimates the distance to existing grid features to connect future plants (Maclaurin et al., 2021). A pressing deficiency in the reV model, however, is representation of geothermal electricity generation technologies. To address this gap, we developed a novel geothermal generation module for reV that allows for representation and analysis at the same level of detail as other renewable technologies. This paper describes our process for evaluating data sources for the modeling, and presents five preliminary reV geothermal results. More specifically, we present two sets of resource data that represent upper and lower bounds for geothermal potential. We then present several sensitivity runs using the upper bound resource data; the results are encouraging that levelized cost of electricity (LCOE) can be reduced by optimizing the location and estimated capacity of the spatially diverse geothermal resource while considering the distance to existing grid infrastructure. Our preliminary supply curves and levelized cost of electricity (LCOE) results should be considered with care due to the highly uncertainty in geothermal resource potential data. We present median LCOE values for the conterminous U.S. for five scenarios: four hydrothermal (3.5km depth) and one EGS (4.5km depth). The capital and operating costs for each respective technology are modeled. We also compare results using two different resource data sources.

exclusions↗

Modeling and Energy Analysis of Refrigeration Systems in Supermarkets: A Case Study

Refrigeration systems are the single largest consumer of electricity in supermarkets, accounting for approximately 40–60% of total store electricity use. As supermarkets face increasing pressures to improve efficiency and reduce operational costs, understanding the energy performance of refrigeration systems in supermarkets has become essential. In this paper, we investigate the energy performance and patterns of the refrigeration system using field measurements in one supermarket. The compressor coefficient of performance (COP) averaged 4.5 during nighttime steady-state operation, providing a practical efficiency benchmark. We develop simple physical-based load models for the display cases in the supermarket, where the refrigeration system uses R404A. The results show the display case models achieve a good agreement with measured data, validating its utility for energy estimation during unoccupied hours. Finally, the analysis reveals several challenges of data collection systems for refrigeration systems in the supermarket industry as well.

Chen, Yimin [ORNL] (ORCID:0000000338181655)↗

Photovoltaic (PV) System Levelized Cost of Energy (LCOE) Evaluation with Grid Support Function Valuation and Service Lifetime Estimation

Photovoltaic (PV) systems play a critical role in renewable energy resource grid integration, and levelized cost of energy (LCOE) is commonly used to evaluate PV system feasibility in modern power grids. In this work, a revised PV system LCOE calculation model is derived to quantify the potential of LCOE reduction. Particularly, the grid support functions are valuated to offset the investment and operation costs of PV systems, which thereby reduces the LCOE. Meanwhile, PV system service lifetime is also estimated with the derived PV inverter reliability model, considering the critical components (i.e., semiconductor devices and capacitors). The case studies with field datasets are conducted to validate the effectiveness of the developed LCOE calculation model.

Zhao, Shijia↗

Literature Review of Advanced Reactor Cost Estimates

This report provides a comprehensive review of existing literature on advanced reactor cost estimations in the form of a ‘meta-study’. Over 30 references were evaluated and considered as part of this effort. The information is then distilled into different tiers, each with varying levels of detail and granularity. The recommendations consist of low/medium/high estimates for capital and operating costs that can be adjusted using various correction factors (based on learning, numbers of plants per site, etc.). In addition, reference breakdown in costs based on a code of account structure is provided for the main four types of advanced reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Economic feasibility of in-motion wireless power transfer in a high-density traffic corridor

Electricity is expected to become a dominant power source in the transportation sector, but under a stationary recharging model, electric powered vehicles still suffer some disadvantages relative to conventional vehicles. Recent developments in wireless power transfer (WPT) technology can enable an alternative vehicle recharging model wherein power is supplied to vehicles while they are moving, mitigating the need for charging stops and high-capacity on-board energy storage. One of the greatest concerns associated with dynamic WPT is that the required infrastructure costs would be prohibitively high; however, the life-cycle costs and benefits of such a system have been under-researched. Here in this work, we apply a systems-level assessment to a case study of a WPT charging system located on the densely trafficked I-710 corridor in Los Angeles, California. Detailed cost estimates for electronics and implementation, high-fidelity energy consumption modeling, and survey-derived adoption projections are applied to evaluate scenarios of economic feasibility and environmental impact. Results show that a “1st-of-a-kind” system can achieve a payback in 20 years while maintaining operating cost advantages relative to petroleum fueling. System economics are shown to improve substantially with “nth-of-a-kind” capital costs. Discussion focuses on the effect of uptake trajectory on economic viability and detailed economics outcomes for light duty and heavy duty vehicles.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Strategic Siting of Direct Air Capture Facilities in the United States

Direct air capture (DAC) systems that capture carbon dioxide (CO 2 ) directly from the atmosphere are garnering considerable attention for their potential role as negative emission technologies in achieving net-zero CO 2 emission goals. Common DAC technologies are based either on liquid–solvent (L-DAC) or solid–sorbent (S-DAC) to capture CO 2 . A comprehensive multi-factor comparative economic analysis of the deployment of L-DAC and S-DAC facilities across various United States (U.S.) cities is presented in this paper. The analysis considers the influence of various factors on the favorability of DAC deployment, including local climatic conditions such as temperature, humidity, and CO 2 concentrations; the availability of energy sources to power the DAC system; and costs for the transport and storage of the captured CO 2 along with the consideration of the regional market and policy drivers. The deployment analysis in over 70 continental U.S. cities shows that L-DAC and S-DAC complement each other spatially, as their performance and operational costs vary in different climates. L-DAC is more suited to the hot, humid Southeast, while S-DAC is preferrable in the colder, drier Rocky Mountain region. Strategic deployment based on regional conditions and economics is essential for promoting the commercial adoptability of DAC, which is a critical technology to meet the CO 2 reduction targets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Techno-Economic Wind Blade Manufacturing Model to Identify Opportunities for Cost Improvements Phase II IACMI Project 4.6/4.8

In IACMI Project 4.6 and IACMI Project 4.8, an Excel-based Techno-Economic Model (TEM) of the manufacturing process for composite wind turbine blades and a DELMIA Factory Flow Simulation of a generic wind blade manufacturing facility was developed. Together, these two tools provide a combined economic modeling capability that accounts for the material, labor, overhead and full-lifecycle operating costs associated with wind blade manufacturing as well as the impact of process flow and factory layout on overall manufacturing efficiency. The tools provide a novel means of detailed comparative analysis of the economic feasibility of proposed technologies and process changes for blade manufacturing. The modeling tools were developed with close support from members of industry and visits to multiple blade manufacturing facilities. With industry oversight, a detailed generalized manufacturing process plan and facility layout were developed with manufacturing parameters, material costs and economic factors based on historical data. Dassault Systèmes and the University of Texas at Dallas (UTD) contributed to the development of the Techno-Economic Model by providing macros to enable the generation of Bill of Material (BOM) data from a 3D blade design in either CATIA or NuMAD format, respectively. The TEM was built with the capability to directly import a Bill of Materials for economic analysis, and with the addition of the macros provided by Dassault and UTD, the TEM can directly import blade designs from both CATIA and NuMAD file formats. The modeling tools developed in Project 4.6 were used to investigate four wind blade manufacturing concepts in detail and select one to explore with laboratory-scale experimentation in Project 4.8. The four manufacturing concepts that were investigated were down-selected by the full project team from a larger list of concepts. The selections were made based on a number of criteria ranking viability and level of interest for each concept. The ‘One-Step Close’ manufacturing concept was ultimately selected for investigation in Project 4.8 and the demonstration was performed at the NREL CoMET facility. The TPI advanced manufacturing facility in Warren, RI contributed the production of several prototype components, the designs for which were developed by Janicki Industries. The demonstration project provided clear indication of the viability of the One-Step Close manufacturing concept for blade manufacturing and good validation of the Techno-Economic Model’s prediction of its economic impact.

17 WIND ENERGY↗

Recent Changes to U.S. Coal Plant Operations and Current Compensation Practices

Over the last decade, the U.S. electric power sector has gone through one of the most dramatic changes in its existence. The combination of low natural gas prices as a result of the shale gas revolution and significant reduction in construction and operating costs for renewable resources, in part due to federal tax credits such as the production tax credit and investment tax credit mainly benefitting wind and solar, respectively, has resulted in a significant shift away from coal-fired generation, and instead towards natural gas and renewable generation. Furthermore, the operating profile of existing coal-fired electric generating units has changed significantly. As new natural gas combined cycle plants have become increasingly more efficient and cheaper to operate than older existing coal-fired power plants, coal units continue to lose baseload generation share and more frequently operate as load-following, or cycling, resources. These trends are of particular importance to state public utility commissions. Functioning as economic regulators, commissions oversee investments in a reliable, efficient system while balancing emissions goals, customer demands, and other policy objectives. Changes to coal plant operations as a result of increased competition from other fuel sources may have a bearing on system reliability and economics, and therefore constitute an important area for commissions to monitor.

01 COAL, LIGNITE, AND PEAT↗

Thermochemical processes for CO 2 hydrogenation to fuels and chemicals: Challenges and opportunities

This manuscript discusses the potential use of CO 2 as a carbon and oxygen carrier to return it to the carbon life cycle in the form of fuels or chemicals via thermochemical catalytic pathways. Theoretically, CO 2 hydrogenation can form a variety of fuels and chemicals. Practically, however, the selectivity, conversion, operating range, and kinetic limitations and operational cost determine the end product. Because of their high value and versatility as a chemical or fuel, small olefins (i.e., C 2 H 4 ) and methanol are often considered as target species. Whether alcohol or olefin formation, CH 4 and CO are the nature’s primary choices of CO 2 conversion. They can be formed over a wide operating temperature, pressure, and CO 2 :H 2 ratios. They are often competitive carbon species in olefin or methanol formation steps. Although they are less valuable as end products, they can be used as intermediate species. Secondary processes of CO and CH 4 to form chemicals and fuels can increase the overall CO 2 hydrogenation yield. Independent of the choice of end product, CO 2 hydrogenation requires hydrogen. Pure hydrogen derived mostly from fossil fuels adds to the overall process cost and also increases the CO 2 emissions. Hydrogen produced from water electrolysis is a renewable green pathway but is limited by the process efficiency and cost. As an alternative to pure hydrogen, low-value, small chain paraffins are suggested as the hydrogen carriers. Carbon dioxide–assisted oxidative dehydrogenation of paraffins to olefins process is a direct pathway to olefin formation. The paper discusses these potential pathways for CO 2 utilization based on theoretical analysis and recent advances in academia and industry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Materials Science of the Interstitial Doping Process

Particle accelerators are an increasingly important tool for frontier science. Growing initial and operating costs are a significant barrier for upgrades and for new machines. While everything matters, the major cost contributor is the SRF cavities and their ancillary facilities (e.g., cryoplant). Accordingly, the accelerator science community devotes much R&D effort to improving their energy efficiency (increased Q o ) and gradient (E acc ). While improved gradient is at the forefront for certain machines (ILC), improved quality factor has broader impact, benefitting all SRF applications. An important opportunity for accelerator science and technology to move forward arose in the course of building the LCLS-II, the second generation Linac Coherent Light Source at SLAC. At more or less the same time, researchers at Fermilab discovered that introducing a small amount of nitrogen to the niobium surface could improve the mid-range quality factor as much as three-fold. A firm resolution of how nitrogen confers its benefit attracts much current research interest. The key elements of the “nitrogen doping” process were vacuum bake at 800 °C, brief exposure to mTorr of nitrogen at several hundred degrees followed by electropolish (EP) to remove several microns from the surface to eliminate unwanted nitrides: While the process as a whole was novel, the comprising unit operations are familiar to the accelerator community. It was judged reasonable to adopt it as a cost-reduction technology for LCLS-II. Researchers carried out a program of varying process parameters and measuring performance in single-cell cavities, leading to a consensus stable protocol for the project. The transition to vendor fabrication and multiple niobium sources has presented unforeseen challenges of performance variation evidently not connected to anything that could be incorporated in a purchase specification. Moving beyond the high temperature N-doping process above, researchers reported a simplified process consisting entirely of tens of hours anneal in a N atmosphere at low temperatures (~120°C – 160°C) after 800 °C UHV bake. These processes typically yield a few-nm doped layer while the high temperature process yields at least a few to many micron doped layer. Even more recently, oxygen has been used to dope instead of nitrogen which leaves a few-µm O-alloyed layer upon vacuum annealing for 300 °C for ~3 hours. The investigation of these materials is just beginning, but the process simplification they may offer is surely attractive. The very low quantity of material that appears to be significant in the “infusion” process indicates the need for very careful control of gas species available for diffusion into the surface during low temperature treatment, both for process control and research to characterize the underlying dynamics. Oxygen alloying offers the further opportunity to utilize the decomposition of the surface native oxide as the dopant source. It is necessary to understand and (thus) manage this process. We have been supported by the Department of Energy Offices of High Energy Physics and Nuclear Physics to pursue this goal.

36 MATERIALS SCIENCE↗

Benefits of Dual Fuel Heat Pump Grid-responsive Control: A Model-based Control Optimization Approach Using Building and Equipment Co-simulation

Conventional dual fuel heat pumps lack the intelligent control mechanisms to efficiently manage the switch between heat pump and furnace, leading to sub-optimal energy usage and, in some cases, increased operating costs. To resolve this gap, this study applies optimized control on hybrid heat pumps. With a focus on equipment control strategies, we compare the performances of five spacing heating equipment, including a conventional heat pump (HP), a conventional furnace, a dual fuel heat pump (DFHP) with conventional control, a dual fuel heat pump with smart control, and a novel seamlessly fuel flexible heat pump (SFFHP). While DFHP runs on either gas or electricity at any given moment, SFFHP concurrently consumes gas and electricity by continuously optimizing the proportion of each. In this research, a co-simulation framework is developed by integrating a building envelope model with a physics-based heat pump simulation model to analyze the benefits of grid-responsive controls of DFHP and SFFHP. The model-based optimal controls adjust the operation of the heat pump and gas furnace based on utility price signals and marginal grid emission to minimize utility cost and CO 2 emissions for multiple climate zones, different utility tariffs, and marginal grid emission scenarios. Case studies in Chicago and Los Angeles demonstrate that SFFHP and DFHP, with model-based optimal control, can deliver significant reductions in peak demand, utility cost, and CO 2 emission. In Chicago, SFFHP and smart controlled DFHP yield up to 64.7% and 61.7% utility cost reduction and up to 15.7% and 8.5% CO 2 emission reduction compared to the gas furnace. In Los Angeles, SFFHP and smart controlled DFHP achieve up to 43.6% and 40.1% utility cost reduction and up to 13.8% and 14.1% CO2 emission reduction compared to conventional heat pumps. In conclusion, by leveraging the fuel flexibility nature of dual fuel heat pumps, the model-based control optimization approach makes dual fuel heat pump an attractive option for demand response programs.

Control↗

Experimental characterization and analysis of phase change material-based thermal energy storage system for refrigerated display case

Refrigerated display cases that are used to store and exhibit food products in supermarkets and retail spaces consume a significant portion of the buildings’ total electricity. Importantly, the refrigeration-related energy cost and demand charges are greatly affected by the time-of-use electricity pricing and demand rates, which are at their maximum during peak hours, typically when refrigeration energy consumption is also high. Using energy storage to shift the refrigeration load from peak to off-peak hours can greatly reduce the operational costs in the supermarket. This study demonstrates a phase change material-based thermal energy storage (TES) system, specifically designed in stackable units, that can be integrated with an open vertical refrigerated display case. We perform numerical and experimental characterization that includes finite-difference modeling for the TES, prototype fabrication, and laboratory evaluation, followed by a preliminary system-level analysis to predict the impact of TES on the refrigerated case performance, energy use, and energy cost. The results show that the dedicated latent TES for refrigerated cases can provide a specific energy of 50.4 Wh/kg and a specific power of 15.5 W/kg. The TES can be charged during 12 h of the off-peak period and discharged at various rates during 4 to 6 h of the peak period, thereby shifting the refrigeration load from the peak to the off-peak period. Consequently, annual cost savings up to 19% can be achieved, depending on the thermal load, the summer/winter peak electricity pricing, and the transition temperature of the phase change material used.

25 ENERGY STORAGE↗