At least 325 records · Page 18

Selection rules and dynamic magnetoelectric effect of the spin waves in multiferroic Bi Fe O 3

Here, we report the magnetic-field dependence of the THz absorption and nonreciprocal directional dichroism spectra of BiFeO 3 measured on the three principal crystal cuts for fields applied along the three principal directions of each cut. From the systematic study of the light polarization dependence, we deduced the optical selection rules of the spin-wave excitations. Our THz data, combined with small-angle neutron scattering results showed that (i) an in-plane magnetic field rotates the q vectors of the cycloids perpendicular to the magnetic field and (ii) the selection rules are mostly determined by the orientation of the q vector with respect to the electromagnetic fields. We observed a magnetic field history-dependent change in the strength and the frequency of the spin-wave modes, which we attributed to the change of the orientation and the length of the cycloidal q vector, respectively. Finally, we compared our experimental data with the results of linear spin-wave theory that reproduces the magnetic-field dependence of the spin-wave frequencies and most of the selection rules, from which we identified the spin-polarization coupling terms relevant for the optical magnetoelectric effect.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Isotopically resolved neutron total cross sections at intermediate energies

The neutron total cross sections σ tot of 16,18 O, 58 64 Ni, 103 Rh, and 112,124 Sn have been measured at the Los Alamos Neutron Science Center from low to intermediate energies (3 ≤ E lab ≤ 450 MeV) by leveraging wave-form-digitizer technology. The σ tot relative differences between isotopes are presented, revealing additional information about the isovector components needed for an accurate optical-model description away from stability. Digitizer-enabled σ tot -measurement techniques are discussed and a series of uncertainty-quantified dispersive optical model (DOM) analyses using these new data is presented, validating the use of the DOM for modeling light systems ( 16,18 O) and systems with open neutron shells ( 58,64 Ni and 112,124 Sn). Here, the valence-nucleon spectroscopic factors extracted for each isotope reaffirm the usefulness of high-energy proton reaction cross sections for characterizing depletion from the mean-field expectation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of large-scale 6 Li-doped pulse-shape discriminating plastic scintillators

A 6 Li-doped plastic scintillator with pulse-shape discrimination capabilities, commercially identified as EJ -299-50, has been developed and produced at the kilogram-scale. A total of 44 bars of dimensions 5.5 cm x 5.5 cm x 50 cm of this material have been characterized. Optical properties like light output and effective attenuation length have been found to be comparable to 6 Li-doped liquid scintillators. Further, the scintillator EJ -299-50 shows good neutron detection capabilities with an effective efficiency for capture on 6 Li of approximately 85%. Stability tests performed on two formulation variations showed no intrinsic degradation in the material or optical properties during several months of observations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Portable Distortion Free Large Solid Angle Coverage Detector

Neutron single crystal diffractometers require large solid angle coverage for optimum performance. This can be achieved by tiling flat detectors in a cylindrical or spherical geometry, but results in large gaps in detector coverage and parallax distortion. The detector edges exhibit degraded resolution, distortion, and gamma rejection. Since the detector edge regions are a significant fraction of the detector active area, they must be removed from the experimental data set, requiring extra beam time to collect enough analysis data. A spherical detector with a continuous surface would effectively address this issue while eliminating most boundary ‘dead’ areas. Here we report on the development of a novel hemispherical shaped neutron detector using seamlessly tiled readout modules to form the desired shape. The heart of the detector is a specially developed curved neutron scintillator coupled to high resolution silicon photomultiplier (SiPM) Anger cameras via custom made fiber optic tapers (FOTs). The detector has been assembled and initial tests have been conducted at the High Flux Isotope Reactor (HFIR) beamlines at Oak Ridge National Laboratory (ORNL). Here, in this work, we describe details of the scintillator design, fabrication and characterization, evaluation of individual detector modules, the details of the detector design implementation, and evaluation of the assembled detector at ORNL beamlines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SOAR/Goodman Spectroscopic Assessment of Candidate Counterparts of the LIGO/Virgo Event GW190814*

On 2019 August 14 at 21:10:39 UTC, the LIGO/Virgo Collaboration (LVC) detected a possible neutron star–black hole merger (NSBH), the first ever identified. An extensive search for an optical counterpart of this event, designated GW190814, was undertaken using the Dark Energy Camera on the 4 m Victor M. Blanco Telescope at the Cerro Tololo Inter-American Observatory. Target of Opportunity interrupts were issued on eight separate nights to observe 11 candidates using the 4.1 m Southern Astrophysical Research (SOAR) telescope’s Goodman High Throughput Spectrograph in order to assess whether any of these transients was likely to be an optical counterpart of the possible NSBH merger. Here, we describe the process of observing with SOAR, the analysis of our spectra, our spectroscopic typing methodology, and our resultant conclusion that none of the candidates corresponded to the gravitational wave merger event but were all instead other transients. Finally, we describe the lessons learned from this effort. Application of these lessons will be critical for a successful community spectroscopic follow-up program for LVC observing run 4 (O4) and beyond.

79 ASTRONOMY AND ASTROPHYSICS↗

Block orbital-selective Mott insulators: A spin excitation analysis

We present a comprehensive study of the spin excitations—as measured by the dynamical spin structure factor S(q,ω)—of the so-called block-magnetic state of low-dimensional orbital-selective Mott insulators. We realize this state via both a multi-orbital Hubbard model and a generalized Kondo-Heisenberg Hamiltonian. Due to various competing energy scales present in the models, the system develops periodic ferromagnetic islands of various shapes and sizes, which are antiferromagnetically coupled. The 2×2 particular case was already found experimentally in the ladder material BaFe2Se3 that becomes superconducting under pressure. Here we discuss the electronic density as well as Hubbard and Hund coupling dependence of S(q,ω) using density matrix renormalization group method. Several interesting features were identified: (1) An acoustic (dispersive spin-wave) mode develops. (2) The spin-wave bandwidth establishes a new energy scale that is strongly dependent on the size of the magnetic island and becomes abnormally small for large clusters. (3) Optical (dispersionless spin excitation) modes are present for all block states studied here. In addition, a variety of phenomenological spin Hamiltonians have been investigated but none matches entirely our results that were obtained primarily at intermediate Hubbard U strengths. Our comprehensive analysis provides theoretical guidance and motivation to crystal growers to search for appropriate candidate materials to realize the block states, and to neutron scattering experimentalists to confirm the exotic dynamical magnetic properties unveiled here, with a rich mixture of acoustic and optical features.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The orbital light curve of PSR 1957 + 20

We make a detailed study of the optical light curve of PSR 1957 + 20. We show that the deep, smooth, and symmetrical modulation can be successfully modeled by a higl irradiated secondary. Two types of models are consistent with the data: (! a secodary close to filling its Rochhe lobe with 10%-20% of the incident flux converted to optical emission, and (2) a secondary considerably underfilling its Roche lobe, with a high degree of beaming of the neutron star flux. owever, the second model canbe rejected on the basis of current estimates of the extinction toward 1957 + 20. The proximity of the photosphere of the secondary to its Roche lobe facilitates mass loss by irradiation. Our ignorance of the (nonirradiated) luminosity of the secondary allows us to place only weak constraints on the inclination -50-80 deg. There is no evidence in the light curve for optical emission from any source in PSR 1957 + 20 other than the secondary itself.

Callanan, Paul J.↗

Gamma-Ray Spectra of r -process Nuclei

The radioactive decay of unstable nuclei created in the rapid neutron capture process releases a large amount of γ-rays. When the ejecta are optically thick, these γ-rays may contribute to an associated kilonova. Once transparent, prominent spectral features will be directly observable in current and future γ-ray detectors. In this work, we study and compare the γ-ray spectra of different representative r-process trajectories across a broad range of timescales, from hours to 50,000 yr, identifying the nuclei that significantly contribute. We discuss these findings in the context of observability, noting that there are several practical challenges to connecting observed signatures to specific nuclei. However, if these challenges can be overcome, direct observation of γ-rays from r-process sites can provide insight into the fundamental physics underpinning the r-process.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron radiographic viewing system

The design, development and application of a neutron radiographic viewing system for use in nondestructive testing applications is considered. The system consists of a SEC vidicon camera, neutron image intensifier system, disc recorder, and TV readout. Neutron bombardment of the subject is recorded by an image converter and passed through an optical system into the SEC vidicon. The vidicon output may be stored, or processed for visual readout.

Source record↗

Influence of dissolved salts and impurities on seawater on heat transfer and fluid flow through fuel channels and debris bed

This project aims to better understand this mechanism and its effect on heat transfer. Specifically, experimental research was conducted to investigate the long term coolability issues in scaled test setups. Advanced diagnostic and measurement techniques were investigated and incorporated into an annular test facility and a debris bed test facility. The diagnostic techniques investigated included: radioactively tagged salt solution, Frisch collar radiation detector array, neutron and x-ray imaging systems, and a Rayleigh backscatter-based fiber-optic temperature system. Models were checked against the in-situ experimental data and recommendations were made for modeling purposes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Retractable Sensors for In-Core Use in Material Test Reactors - conf paper

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 - 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on friction drive wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 - 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology's MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retractable Sensors for In-Core Service in Material Test Reactors

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 - 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on counter-rotating wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 - 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology's MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Retractable Sensors for In-Core Service in Material Test Reactors

Material Test Reactors (MTRs) such as the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) are used to irradiate nuclear fuels and materials to evaluate their performance after high levels of exposure to a reactor in-core environment. The most critical tests are equipped with instrumentation leads, which allow real-time data collection. However, because of the very harsh environment inside high-power MTR experiments, there are very few sensors that can survive and maintain their calibrated readings for the time periods required to obtain the high neutron doses needed for new fuels and materials qualification. As a result, sometimes sponsoring programs are forced to accept low reliability of sensors, collecting useful data for only part of the experiment duration. The work described herein is based on the observation that MTRs normally run at constant power and the corresponding conditions within reactor experiments typically evolve relatively slowly. Therefore, even one or two measurements per day would provide a complete and representative data set. With this in mind, INL has embarked on a program to develop a mechanism capable of pushing a very small-diameter sensor (typically a thermocouple or optical fiber) into the location to be measured, leave the sensor for roughly 60 seconds to allow it to reach equilibrium and transmit the signal, then pull it up and away from the high neutron flux and high-temperature region. Small-diameter capillary tubes, up to 8 m long, are used to guide the sensors to the appropriate locations. These capillary tubes serve as essentially very deep, thin-walled thermowells. The distance a thermocouple or optical fiber would need to traverse is on the order of 40 – 80 cm. By adopting this infrequent cycling strategy, the thermocouple or optical fiber would spend only a few hours in the high-neutron flux/high-temperature environment over the duration of even the longest irradiation experiment. To date, INL has developed two styles of drive mechanisms. The first is based on counter-rotating wheels which drive the sensors in a manner similar to a small MIG welder. This has the advantage of being able to accommodate a very long insertion length. The second is based on a ball screw drive and has the advantages of positive attachment and being able to move more than one sensor at a time. Both drive mechanisms have been fabricated and tested in a laboratory setting. Both systems can handle hard mineral insulated cable (such as thermocouples) or optical fibers encased in small diameter tube. The sizes tested to date are 1 – 1.6 mm diameter. Work in this area is ongoing with an eye toward demonstration in the Massachusetts Institute of Technology’s MITR reactor, followed by deployment in an ATR irradiation experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precise Control of Noncovalent Interactions in Semiconducting Polymers for High-Performance Organic Field-Effect Transistors

Performed through side-chain engineering or by incorporating intramolecular locking units, the directionality and dynamic nature of noncovalent interactions are particularly attractive for the design of novel semiconducting materials in a wide variety of applications. This work investigates the nature and position of hydrogen bonding (intra- versus intermolecular), with the objective of developing a rational approach to the design of new semiconducting materials with improved properties in the solid state. To control the polymer chains’ self-assembly, a π-conjugated polymer incorporating a moiety capable of generating intramolecular hydrogen bonding is evaluated against a polymer that allows for intermolecular hydrogen bonding. Characterization through various techniques, optical spectroscopies, grazing incidence wide-angle x-ray scattering, and solution small-angle neutron scattering showed that intramolecular hydrogen bonds resulted in materials with improved crystallinity and higher effective conjugation in the solid state. Additionally, the effect of the noncovalent interaction configuration on the optoelectronic properties was analyzed in organic field-effect transistor fabrication. Devices prepared from the materials with intramolecular hydrogen bonds showed significantly higher performance, with three orders of magnitude higher charge mobility than their counterparts fabricated from polymers with intermolecular hydrogen bonds. These results confirm the importance of chemical design on polymer structures and offer a novel route for the design of high-efficiency semiconducting polymers for next-generation electronics.

36 MATERIALS SCIENCE↗

Cleavable quaternary oxychlorides with high magnetic ordering temperatures

Quaternary oxychlorides derived from Ruddlesden–Popper 3d transition metal oxides offer a route to cleavable crystals with bulk antiferromagnetic ordering temperatures reaching at least 550 K. Here, we study the magnetic, optical, and mechanical behavior of Sr 2 FeO 3 Cl, Ca 2 FeO 3 Cl, Ca 3 Fe 2 O 5 Cl 2 , and Sr 3 Fe 2 O 5 Cl 2 . Through optical absorption measurements, we show that these antiferromagnetic semiconductors have optical band gaps of ≈2.1(1) eV. The magnetic ordering symmetries and temperatures were probed by neutron powder diffraction and Mössbauer spectroscopy on polycrystalline samples, demonstrating Néel temperatures (T N ) near room temperature in the single layer Sr 2 FeO 3 Cl (T N ≈ 311 K) and Ca 2 FeO 3 Cl (T N ≈ 360 K), and the double-layer compound Sr 3 Fe 2 O 5 Cl 2 has T N ≈ 545 K. The high-spin moments of Fe 3+ lie within the basal plane and the magnetic structures are compensated within each magnetic layer and characterized by magnetic propagation vectors k = ($\frac{1}{2}$ $\frac{1}{2}$ 0). Magnetization results demonstrate the quasi-2D nature of the magnetism, with a broad maximum in the susceptibility near 2T N for Sr 2 FeO 3 Cl. Scotch tape tests and mechanical exfoliation onto SiO 2 confirm the micaceous nature of these crystals with cleavage down to a single unit cell (two magnetic layers) achieved for Sr 3 Fe 2 O 5 Cl 2 . In conclusion, this paper highlights strong antiferromagnetic interactions, semiconducting band gaps, and cleavability of quaternary Fe-based oxychlorides and motivates future work on crystals and exfoliated flakes of these and related oxyhalide systems.

36 MATERIALS SCIENCE↗

Characterization of Mk-IV and EBR-II X441A Metallic Fuel Pins for the THOR-C-2 and THOR-M-TOP-1 Experiments: Results from Post-Transient Neutron Tomography of THOR-C-2 Capsule and Pre-transient Non-Destructive and Destructive Examination of DP 36 and DP 40 (Rev.1)

Current interest in sodium-cooled fast reactor designs, such as TerraPower’s Natrium Reactor, has highlighted the need for advanced-reactor fuel technology development. A Fuel Safety Research and Development (FSRD) program for metallic fast reactor fuels has been created to achieve comprehensive safety testing within the re-commissioned Transient Reactor Test (TREAT) facility at the Idaho National Laboratory. Despite over 60 years of metallic fuel irradiation, uncertainties exist in the performance of the fuel system, particularly under anticipated operational occurrences and severe accident scenarios. Throughout historical testing within the Experimental Breeder Reactor (EBR)-II and the Fast Flux Test Facility, fuel behavior has demonstrated benign response to transient reactor conditions; however, accurate predictions of failure thresholds rely heavily on fuel composition and irradiation history. In advancing the FSRD program, two planned transient heating experiments are at various stages of completion. The Temperature Heat sink Overpower Response (THOR)-C-2, fueled with an unirradiated Mk IV U-10Zr pin, has undergone transient irradiation in TREAT and post-transient three-dimensional neutron tomography. Additionally, pre-transient characterization of test and sibling U-19Pu-10Zr pins for THOR-M-TOP-1 was evaluated by both non-destructive and destructive methods. The test and sibling pins were selected from previously irradiated EBR-II experiment X441A. Both pins underwent visual examination, precise gamma spectrometry, two-dimensional neutron radiography, and element contact profilometry while the sibling pin was additionally subjected to sectioning and optical microscopy. THOR-C-2 radiography captured the fuel and cladding relocation during the intermediate transient at the top and bottom of the THOR capsule, allowing key features to be linked to the pin’s measured thermal response. For THOR M TOP 1, a solid baseline for steady-state behavior has been established. No anomalous features were identified in either the test or sibling pin. Defining characteristics and features were recorded for further comparisons.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Glancing incidence telescope for far ultraviolet and soft X-rays

Glancing-incidence telescope makes observations of distant celestial radiant bodies at wavelengths in the spectral region between 3 and 500 angstroms. The device can be used as a fore-optics system for a laboratory extreme ultraviolet spectrometer, or for the collection or imaging of thermal neutrons.

Neupert, W. M.↗