Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “multilevel method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Harmonic control using matrix converter of unbalanced input voltage supplied from solar power system

Most of the renewable energy sources are not distributed directly to consumer. It gone through several section to get optimum output voltage and current with the almost zero distortion. Direct Matrix converters are well known of its better power quality and low power distortion to the reactive loads. Conversely, multilevel H bridge inverters are broadly used to attain a sinusoidal output voltage in solar photovoltaic application. Reactive power is subject to high importance for the operation of alternating current (AC) power systems. Moreover there is always a challenge to obtain the balance current control from an unbalanced supply voltage with minimum harmonic distortion for reactive load application from solar power system. The main objective of the proposed system is to maximize the power usage by maintaining the current and power factor nearby unity. There are many different optimization techniques are used so far in matrix converter, a novel method of optimization BAT algorithm is proposed for the power quality to get the best result. This work mainly deals with the compensation of reactive power used in Solar Photovoltaic Power System. Bidirectional energy flow is possible with matrix converter for battery charging. Simulation results are presented to confirm the appropriate operation of the system under different of operating conditions. Also, in the proposed method the percentage of the higher order harmonics can reduced less than 9% of matrix converter for solar photovoltaic application.

14 SOLAR ENERGY↗

Multilevel well modeling in aggregation-based nonlinear multigrid for multiphase flow in porous media

A full approximation scheme (FAS) nonlinear multigrid solver for two-phase flow and transport problems driven by wells with multiple perforations is developed here. It is an extension to our previous work on FAS solvers for diffusion and transport problems. The solver is applicable to discrete problems defined on unstructured grids as the coarsening algorithm is aggregation-based and algebraic. To construct coarse basis that can better capture the radial flow near wells, coarse grids in which perforated well cells are not near the coarse-element interface are desired. This is achieved by an aggregation algorithm proposed in this paper that makes use of the location of well cells in the cell-connectivity graph. Numerical examples in which the FAS solver is compared against Newton's method on benchmark problems are given. In particular, for a refined version of the SAIGUP model, the FAS solver is at least 35% faster than Newton's method for time steps with a CFL number greater than 10.

58 GEOSCIENCES↗

Machine Learning Applied to a Variable Charge Atomistic Model for Cu/Hf Binary Alloy Oxide Heterostructures [Machine Learning a Variable Charge Atomistic Model for Cu/Hf Binary Alloy Oxide Heterostructures]

Alloy oxide heterostructures are essential for a wide variety of energy applications, including anticorrosion coatings, bifunctional catalysis, energy storage, as well as emerging platforms for multilevel nonvolatile memory and neuromorphic devices. The key role played by oxide composition, density, and stoichiometry in governing electrochemical reactions, interface structure, and ionic transport in alloy oxides remains largely unknown. This is primarily due to the lack of variable charge interatomic potential models that can adequately describe the various atomic/ionic interactions in alloy oxides within a unified framework. Here, we introduce a charge transfer ionic potential (CTIP) model for Cu/Hf/O alloy system and demonstrate its ability to accurately capture the complex potential energy surface owing to dynamically varying interactions, including metallic (Cu/Hf), ionic (Cu/Hf/Ox), mixed environment (interfaces). We leverage supervised machine learning methods powered by genetic algorithms coupled with local simplex optimization to efficiently navigate through a high-dimensional parameter space and identify an optimum set of an independent set of CTIP parameters. We train our model against an extensive first-principles based data set that includes lattice constants, cohesive energies, equations of state, and elastic constants of various experimentally observed polymorphs of hafnia, copper oxide, hafnium, as well as copper. Our machine-learned CTIP model captures the structure, elastic properties, thermodynamics, and energetic ordering of various polymorphs. It also accurately predicts the surface properties of both oxides and their metals. To demonstrate the suitability of our CTIP model for investigating dynamic processes, we employed it to identify the atomistic scale mechanisms associated with the initial nanoscale oxidation and surface oxide growth on Cu-doped hafnia surfaces. Here, our machine-learned CTIP model can be used to probe the dynamic response of Cu/Hf/O alloy interfaces subjected to external stimuli (e.g., electric field, pressure, temperature, strain, etc.) and a variety of atomistic phenomena including the dynamics of switching in emerging neuromorphic platforms.

36 MATERIALS SCIENCE↗

A resettable in-line particle concentrator using AC electrokinetics for distributed monitoring of microalgae in source waters

Green algae have been studied as an important and effective biomarker to indicate water quality due to their sensitivity to toxic agents in freshwater sources. But, conventional methods to monitor algal physiology use a chlorophyll fluorometer whose use is hampered by high-cost, large footprint, and limited sensitivity for practical samples containing low algal concentration. In order to overcome these constraints, we developed a multi-level electrode platform for resettable trapping of algae via AC electro-osmosis (ACEO) and negative dielectrophoresis. Preliminary experiments were performed in freshwater with conductivity of 0.02 S/m. Algal trapping was demonstrated at a low voltage of 2 V. The concentration effect was experimentally verified by measuring the fluorescence intensity of algae and using hemocytometer counting chambers at the inlet and outlet of the multilevel microchannel lab-on-a-chip. An optimal frequency was found for trapping, which agrees with the frequency dependence of ACEO flow velocity. Through-flow rate and electrode dimensions were optimized as well. Trapping efficiencies within the range of 26% - 65% have been obtained. A maximum trapping rate of 182 cells/s was obtained with a flow rate of 20 l/min. Our lab-on-a-chip shows high potential for improving the limit of detection in algal monitoring and enabling the development of a portable, integrated and automated system for monitoring the quality of source drinking waters.

30 DIRECT ENERGY CONVERSION↗

Multi-Level Optimal Power Flow Solver in Large Distribution Networks

Solving optimal power flow (OPF) problems for large distribution networks incurs high computational complexity. We consider a large multi-phase distribution network of tree topology with a deep penetration of active devices. We divide the network into collaborating areas featuring subtree topology and subareas featuring subsubtree topology. We design a multilevel implementation of the primal-dual gradient algorithm to solve the voltage regulation OPF problems while preserving nodal voltage information and topological information within areas and subareas. Numerical results on a 4,521-node system verify that the proposed algorithm can significantly improve the computational speed without compromising any optimality.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Spontaneous Intramuscular Hematomas of the Abdomen and Pelvis: A New Multilevel Algorithm to Direct Transarterial Embolization and Patient Management

PurposeTo report our experience using a multilevel patient management algorithm to direct transarterial embolization (TAE) in managing spontaneous intramuscular hematoma (SIMH).Materials and MethodsFrom May 2006 to January 2014, twenty-seven patients with SIMH had been referred for TAE to our Radiology department. Clinical status and coagulation characteristics of the patients are analyzed. An algorithm integrating CT findings is suggested to manage SIMH. Patients were classified into three groups: Type I, SIMH with no active bleeding (AB); Type II, SIMH with AB and no muscular fascia rupture (MFR); and Type III, SIMH with MFR and AB. Type II is furthermore subcategorized as IIa, IIb and IIc. Types IIb, IIc and III were considered for TAE. The method of embolization as well as the material been used are described. Continuous variables are presented as mean ± SD. Categorical variables are reported as percentages. Technical success, clinical success, complications and 30-day mortality (d30 M) were analyzed.ResultsTwo patients (7.5%) had Type IIb, four (15%) Type IIc and 21 (77.5%) presented Type III. The detailed CT and CTA findings, embolization procedure and materials used are described. Technical success was 96% with a complication rate of 4%. Clinical success was 88%. The bleeding-related thirty-day mortality was 15% (all with Type III).ConclusionTAE is a safe and efficient technique to control bleeding that should be considered in selected SIMH as soon as possible. The proposed algorithm integrating CT features provides a comprehensive chart to select patients for TAE.Level of Evidence4.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive Narrowband Damping for Improving Harmonic Stability of Modular Multilevel Converter

Harmonic instability events between modular multilevel converter (MMC) and ac systems have been widely reported in recent years. To damp harmonic resonance, this paper proposes an adaptive narrowband damping control that automatically programs, adds, and adjusts the damping around the oscillation frequency when an oscillation is detected. First, the paper presents a low-pass filter design for MMC control loops that pushes all negative damping of the MMC impedance down to the medium-frequency range (< ~ 1000 Hz). Then, an adaptive damping control that uses online oscillation detection is proposed, which can automatically configure the narrowband damper to provide positive damping to the MMC around the detected oscillation frequency. In contrast to existing narrowband damping methods, the proposed adaptive narrowband damper dynamically adjusts the damping gain and the width of the damping range based on continuous monitoring of system resonance conditions (e.g., adjust damping gain to zero when the system resonance disappears). Electromagnetic transient simulation results validate the efficacy of the proposed method in two typical MMC-based power systems.

active damping↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems: Preprint

For the development of multi-terminal high voltage DC (MTDC) transmission, it is critical to design the protection system that can selectively isolate the faulty area from the healthy part of the dc grid using DC circuit breakers (DCCBs) while ensuring continuous operation of converter stations in the healthy part. However, because of the lack of fault current blocking capability in half-bridge (HB) modular multilevel converters (MMCs), when a dc fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of MMCs in the healthy part. Large DC reactors are often considered in series with DCCBs to reduce the rate of rise of fault currents and prevent blocking of MMCs in the healthy part of the grid. However, large DC reactors can prohibitively increase the cost of the system, particularly when they are considered in an offshore environment, for instance in offshore wind projects. Large dc reactors can also introduce stability issues and create post-fault oscillations. This paper presents an adaptive fault current limiting control method for MMCs to avoid their blocking and enable continuous operation of MTDC systems. It contains two parts: The first part is based on circulating current feedforward control that emulates virtual reactors in each arm of an MMC, which is immediately activated when the fault current starts to increase, to reduce the rate of rise of the fault current; the second part is triggered when the fault current exceeds a preset threshold by temporarily bypassing the SMs, serving as a complement to the fault current limiting effect of the first part. Both parts do not require fault detection signal and they are activated automatically during faults. Simulation case studies of a four-terminal bipolar MMC-HVDC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

{sup 13}N+p elastic resonance scattering via a thick-target method

The {sup 13}N+p elastic resonance scattering has been studied in inverse kinematics via a thick-target method. A {sup 13}N secondary beam of 47.8{+-}1.5 MeV produced by the {sup 2}H({sup 12}C,{sup 13}N)n reaction was used to bombard a 9.33 mg/cm{sup 2} (CH{sub 2}){sub n} target. The recoil protons were detected by a {delta}E-E silicon counter telescope at {theta}{sub lab}=15 deg. The performance of the setup was checked by {sup 12}C+p elastic resonance scattering with the same (CH{sub 2}){sub n} target. The excitation function for the {sup 13}N(p,p) elastic scattering was obtained in the energy interval of E{sub c.m.}{approx}0.5-3.2 MeV and was analyzed by using a multilevel R-matrix code MULTI7. Several low-lying excited states in {sup 14}O were surveyed. Our results confirm a very recent 2{sup -} assignment to the 6.8 MeV level and agree with the observation of a new 0{sup -} level at 5.7 MeV with a width of 400(45) keV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Predictive Direct DC-Link Control for 7.2 kV Three-Port Low-Inertia Solid-State Transformer With Active Power Decoupling

Promising for applications including renewable energy and electric vehicle fast charging, a medium-voltage (MV) solid-state transformer (SST) typically has multiple modules series stacked, which requires the modules to be single phase. One critical issue of the single-phase SST is the double-line-frequency power ripple. Traditionally, large passives are used to buffer the ripple, resulting in significantly increased volume and cost. This article for the first time proposes active power decoupling (APD) for the SST and a predictive direct DC-link control method, using a current-source single-stage SST as an example. An electrolytic capacitor-less buffer port is used to absorb the ripple, which tolerates up to a 30% voltage ripple for small capacitance. The APD SST control is challenging. First, the current-source SST realizes isolation, DC link, and multiport in a single stage. Second, different from conventional SSTs or APD converters, the low-inertia DC link in this SST has a 40% switching ripple, which is difficult to stabilize. To address the control challenge, a direct DC-link control architecture and a predictive control method are proposed. Simulation and experimental results verify the proposed control method on an MV SiC modular soft-switching solid-state transformer (M-S4T) prototype. Here, the proposed APD reduces the SST volume by 53.8%. Importantly, the proposed concept is not limited to the M-S4T but is generic to other SSTs or APD converters.

14 SOLAR ENERGY↗

InAs sidewall tunnel diodes enabled by surface states

Negative differential resistance (NDR), where the device current decreases with increasing bias voltage, is a representative phenomenon where quantum mechanics induces counterintuitive physical behavior and offers promising applications such as high-frequency oscillators, amplifiers, and multilevel logic circuits. While the NDR behavior has been extensively studied in various materials and devices, the role of surface properties in NDR, particularly in InAs-based diodes, remains underexplored. In this work, we report the observation of NDR in vertically structured InAs p + n diodes that exhibit a peak-valley current ratio of ∼6, which is suitably high for applications. Circumference-normalized current–voltage characterization revealed that the NDR originates from band-to-band tunneling between the valence band of p + -InAs and the conduction band of an n + -InAs surface, where the n + surface is due to surface states on otherwise n − -InAs. In addition, by comparing devices with various surface passivation methods (without intentional passivation, benzocyclobutene polymer, and silicon nitride), we found that the surface termination significantly affects the NDR characteristics. We present an equivalent circuit model to explain the observed device behavior. These findings offer insights into surface-enabled NDR phenomena and present new knobs for engineering NDR devices.

Circuit theorems↗

Updated User's Guide for Sammy: Multilevel R-Matrix Fits to Neutron Data Using Bayes' Equations

In 1980 the multilevel multichannel R-matrix code SAMMY was released for use in analysis of neutron-induced cross section data at the Oak Ridge Electron Linear Accelerator. Since that time, SAMMY has evolved to the point where it is now in use around the world for analysis of many different types of data. SAMMY is not limited to incident neutrons but can also be used for incident protons, alpha particles, or other charged particles; likewise, Coulomb exit hannels can be included. Corrections for a wide variety of experimental conditions are available in the code: Doppler and resolution broadening, multiple-scattering corrections for capture or reaction yields, normalizations and backgrounds, to name but a few. The fitting procedure is Bayes' method, and data and parameter covariance matrices are properly treated within the code. Pre- and post-processing capabilities are also available, including (but not limited to) connections with the Evaluated Nuclear Data Files. Though originally designed for use in the resolved resonance region, SAMMY also includes a treatment for data analysis in the unresolved resonance region.

43 PARTICLE ACCELERATORS↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems

A crucial requirement of the protection system for multi-terminal high-voltage DC (MTDC) transmission is that it is capable of selectively isolating the faulty area from the healthy part of the network using DC circuit breakers (DCCBs), while ensuring continuous operation of converter stations in the healthy part of the network. But in the half-bridge modular multilevel converters (HB-MMCs) based MTDC system, since HB-MMCs do not have fault current absorption capability, when a DC fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of the MMCs in the healthy part. To facilitate fault-ride-through capability of MTDC system, large DC reactors are often considered in series with DCCBs to reduce the rate of rise of the fault current and prevent blocking the MMCs in the healthy part of the DC networks; however, large DC reactors prohibitively increase the cost of the system, introduce stability issues and can create post-fault oscillations. This paper presents an adaptive fault current-limiting control method for MMCs to avoid their blocking and enable the continuous operation of the healthy part of MTDC systems. The method contains two parts: The first part is based on circulating current feedforward control, which emulates virtual reactors in each arm of an MMC, and is immediately activated when the fault current starts to increase to reduce the rate of rise of the fault current. The second part temporarily bypasses all the submodules when the fault current exceeds a preset threshold, complementing the fault current-limiting effect of the first part. Neither part requires fault detection signals, and they are automatically activated during faults. Simulation case studies of a four-terminal bipolar MMC-based high-voltage DC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

Adaptive Narrowband Damping for Improving Harmonic Stability of Modular Multilevel Converter: Preprint

Harmonic instability events between modular multilevel converter (MMC) and ac systems have been widely reported in recent years. To resolve it, this paper proposes an adaptive narrowband damping control that automatically programs, adds and adjusts damping around the oscillation frequency when detect the oscillation. The paper first presents a low-pass filter design for MMC control loops, which pushes all negative damping of MMC impedance down to the medium frequency range (< approximately 1000 Hz). This makes narrowband damping can be more targeted and easier to design because multiple harmonic oscillations are avoided. An adaptive damping control that uses online oscillation detection is then proposed, which can automatically configure the narrowband damper to provide damping to the MMC at the detected oscillation frequency. In contrast to existing narrowband damping methods, the proposed adaptive narrowband damper adjusts the damping gain (e.g., to zero when system resonance disappears) and the width of the damping range automatically based on continuous monitoring of system resonance conditions. Electromagnetic transient (EMT) simulation results validate the efficacy of the proposed method in two typical MMC-based power systems.

active damping↗

Multi-level Monte Carlo methods in chemical applications with Lennard-Jones potentials and other landscapes with isolated singularities

We describe and compare outcomes of various Multi-Level Monte Carlo (MLMC) method variants, motivated by the potential of improved computational efficiency over rejection based Monte Carlo, which scales poorly with problem dimension. With an eye toward its application to computational chemical physics, we test MLMC's ability to sample trajectories on two problems — a familiar double-well potential, with known stationary distributions, and a Lennard-Jones solid potential (a Galton Board). By sampling Brownian motion trajectories, we are able to compute expectations of observable averages. These multi-basin potential energy problems capture the essence of the challenges with using MLMC, namely, maintaining correspondence of sample paths as time-resolution is varied. Addressing this challenge properly can lead to MLMC significantly outperforming standard Monte Carlo path sampling. We describe the essence of this problem and suggest strategies that circumvent diverging multilevel sample paths for an important class of problems. In the tests we also compare the computational cost of several, “adaptive,” variants of MLMC. Our results demonstrate that MLMC overcomes the collision, time scale limitation of the more familiar Brownian path MC samplers, and our implementation provides tunable error thresholds, making MLMC a promising candidate for application to larger and more complex molecular systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sub-Doppler Cooling of a Trapped Ion in a Phase-Stable Polarization Gradient

Trapped ions provide a highly controlled platform for quantum sensors, clocks, simulators, and computers, all of which depend on cooling ions close to their motional ground state. Existing methods like Doppler, resolved sideband, and dark resonance cooling balance trade-offs between the final temperature and cooling rate. A traveling polarization gradient has been shown to cool multiple modes quickly and in parallel, but utilizing a stable polarization gradient can achieve lower ion energies, while also allowing tailorable light-matter interactions in the sub-wavelength regime. In this Letter, we demonstrate cooling of a trapped ion below the Doppler limit using a phase-stable polarization gradient created using trap-integrated photonic devices. At an axial frequency of 2⁢𝜋×1.45 MHz we achieve ⟨𝑛⟩=1.56±0.07 in 150 μ⁢s and cooling rates of ∼0.3 quanta/μ⁢s. Here, we examine ion dynamics under different polarization gradient phases, detunings, and intensities, showing reasonable agreement between experimental results and a multilevel model. Cooling is fast and power efficient, with lower average motional Fock state occupation when compared to simulated operation under the corresponding running wave configuration. Our results demonstrate a well-controlled test bed for studying the dynamics of multilevel atomic systems in a phase-stable polarization gradient.

Atom & ion cooling↗

Generalization of mixed multiscale finite element methods with applications

Many science and engineering problems exhibit scale disparity and high contrast. The small scale features cannot be omitted in the physical models because they can affect the macroscopic behavior of the problems. However, resolving all the scales in these problems can be prohibitively expensive. As a consequence, some types of model reduction techniques are required to design efficient solution algorithms. For practical purpose, we are interested in mixed finite element problems as they produce solutions with certain conservative properties. Existing multiscale methods for such problems include the mixed multiscale finite element methods. We show that for complicated problems, the mixed multiscale finite element methods may not be able to produce reliable approximations. This motivates the need of enrichment for coarse spaces. Two enrichment approaches are proposed, one is based on generalized multiscale finte element metthods (GMsFEM), while the other is based on spectral element-based algebraic multigrid (rAMGe). The former one, which is called mixed GMsFEM, is developed for both Darcy’s flow and linear elasticity. Application of the algorithm in two-phase flow simulations are demonstrated. For linear elasticity, the algorithm is subtly modified due to the symmetry requirement of the stress tensor. The latter enrichment approach is based on rAMGe. The algorithm differs from GMsFEM in that both of the velocity and pressure spaces are coarsened. Due the multigrid nature of the algorithm, recursive application is available, which results in an efficient multilevel construction of the coarse spaces. Stability, convergence analysis, and exhaustive numerical experiments are carried out to validate the proposed enrichment approaches. iii

97 MATHEMATICS AND COMPUTING↗

Robust Predictive Control for Modular Solid-State Transformer With Reduced DC Link and Parameter Mismatch

This paper presents the analysis and implementation of a predictive control method for dc-link regulation and voltage balance in a cascaded modular reduced dc-link solid-state transformer (SST). Passive components like bulky dc links limit the power density of power converters, especially medium-voltage (MV) SST. Reduced dc-link or low-inertia converters can dramatically reduce the size, cost, and weight by tolerating larger dc-link ripples and improve the reliability with electrolytic capacitor-less dc link. However, a small dc link leads to tight coupling between the input and the output stages, which is a challenge for control design. In stacked low-inertia converters (SLIC), the low-inertia converter modules are stacked for MV applications, resulting in coupling between the modules and making the control more challenging. A new model predictive control method which can achieve deadbeat regulation on the dc link without weighting factors has been proposed to address this novel problem. This paper focuses on analyzing the condition of the low-inertia dc link up to 80% ripple, the robustness of the control under parameter mismatches, high-order terms, and important implementation issues such as model-based sampling and computation delay compensation. Significantly, the high-order terms are introduced because of the large dc-link ripple. These high-order terms are unique to the SLIC and negligible in conventional high-inertia converters. A discrete-time large-signal model is built to capture the dc-link’s nonlinear dynamics, and the eigenvalues of a small-signal Jacobian matrix are analyzed with Floquet theory to evaluate stability, using the modular soft-switching solid-state transformer (M-S4T) as an example of the SLIC. Simulation and experimental results of an MVDC M-S4T verify the analysis and the predictive control method. Finally, the general application of the predictive control to low-inertia converters is compared against a conventional PI controller using a reduced dc-link active-front-end (AFE) rectifier as an example.

14 SOLAR ENERGY↗