Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microscope”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Development of a detachable high speed miniature scanning probe microscope for large area substrates inspection

We have developed a high speed, miniature scanning probe microscope (MSPM) integrated with a Positioning Unit (PU) for accurately positioning the MSPM on a large substrate. This combination enables simultaneous, parallel operation of many units on a large sample for high throughput measurements. The size of the MSPM is 19 × 45 × 70 mm{sup 3}. It contains a one-dimensional flexure stage with counter-balanced actuation for vertical scanning with a bandwidth of 50 kHz and a z-travel range of more than 2 μm. This stage is mechanically decoupled from the rest of the MSPM by suspending it on specific dynamically determined points. The motion of the probe, which is mounted on top of the flexure stage is measured by a very compact optical beam deflection (OBD). Thermal noise spectrum measurements of short cantilevers show a bandwidth of 2 MHz and a noise of less than 15 fm/Hz{sup 1/2}. A fast approach and engagement of the probe to the substrate surface have been achieved by integrating a small stepper actuator and direct monitoring of the cantilever response to the approaching surface. The PU has the same width as the MSPM, 45 mm and can position the MSPM to a pre-chosen position within an area of 275×30 mm{sup 2} to within 100 nm accuracy within a few seconds. During scanning, the MSPM is detached from the PU which is essential to eliminate mechanical vibration and drift from the relatively low-resonance frequency and low-stiffness structure of the PU. Although the specific implementation of the MSPM we describe here has been developed as an atomic force microscope, the general architecture is applicable to any form of SPM. This high speed MSPM is now being used in a parallel SPM architecture for inspection and metrology of large samples such as semiconductor wafers and masks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A full-field transmission x-ray microscope for time-resolved imaging of magnetic nanostructures

Sub-nanosecond magnetization dynamics of small permalloy (Ni{sub 80}Fe{sub 20}) elements has been investigated with a new full-field transmission microscope at the soft X-ray beamline P04 of the high brilliance synchrotron radiation source PETRA III. The soft X-ray microscope generates a flat-top illumination field of 20 μm diameter using a grating condenser. A tilted nanostructured magnetic sample can be excited by a picosecond electric current pulse via a coplanar waveguide. The transmitted light of the sample plane is directly imaged by a micro zone plate with < 65 nm resolution onto a 2D gateable X-ray detector to select one particular bunch in the storage ring that probes the time evolution of the dynamic information successively via XMCD spectromicroscopy in a pump-probe scheme. In the experiments it was possible to generate a homogeneously magnetized state in patterned magnetic layers by a strong magnetic Oersted field pulse of 200 ps duration and directly observe the recovery to the initial flux-closure vortex patterns.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a scanning transmission x-ray microscope for the beamline P04 at PETRA III DESY

We present a scanning transmission x-ray microscope (STXM) built on top of our existing modular platform for high resolution imaging experiments. This platform consists of up to three separate vacuum chambers and custom designed piezo stages. These piezo stages are able to move precisely in x-, y- and z-direction, this makes it possible to adjust the components for different imaging modes. During recent experiments the endstation was operated mainly as a transmission x-ray microscope (TXM) [1, 2].

43 PARTICLE ACCELERATORS↗

Scanning tunneling microscope design with a confocal small field permanent magnet.

The field of ultra-sensitive measurements with scanning probes requires the design and construction of novel instruments. For example, the combination of radio frequency detection and scanning probe can be exploited to measure thermal properties and mechanical resonances at a very low scale. Very recent results by Komeda and Manassen (2008 Appl. Phys. Lett. 92 212506) on the detection of spin noise with the scanning tunneling microscopy (STM) have further expanded previous results reported by one of the authors of this manuscript (Messina et al 2007 J. Appl. Phys. 101 053916). In a previous publication, one of the authors used a new STM instrument (Messina et al J. Appl. Phys. 2007 101 053916 and Mannini et al 2007 Inorg. Chim. Acta 360 3837-42) to obtain the detection of electron spin noise (ESN) from individual paramagnetic adsorbates. The magnetic field homogeneity at the STM tip-sample region was limited. Furthermore, vacuum operation of the STM microscope was limited by the heat dissipation at the electromagnet and the radio frequency (RF) recovery electronics. We report here on a new STM head that incorporates a specially designed permanent magnet and in-built RF amplification system. The magnet provides both a better field homogeneity and freedom to operate the instrument in vacuum. The STM microscope is vacuum compatible, and vertical stability has been improved over the previous design (Messina et al 2007 J. Appl. Phys. 101 053916), despite the presence of a heat dissipative RF amplifier in the close vicinity of the STM tip.

47 OTHER INSTRUMENTATION↗

Catalytic enhancement in the performance of the microscopic two-stroke heat engine

Here we consider a model of heat engine operating in the microscopic regime: the two-stroke engine. It produces work and exchanges heat in two discrete strokes that are separated in time. The working body of the engine consists of two d-level systems initialized in thermal states at two distinct temperatures. Additionally, an auxiliary nonequilibrium system called catalyst may be incorporated with the working body of the engine, provided the state of the catalyst remains unchanged after the completion of a thermodynamic cycle. This ensures that the work produced by the engine arises solely from the temperature difference. Upon establishing the rigorous thermodynamic framework, we characterize twofold improvement stemming from the inclusion of a catalyst. Firstly, we prove that in the noncatalytic scenario, the optimal efficiency of the two-stroke heat engine with a working body composed of two-level systems is given by the Otto efficiency, which can be surpassed by incorporating a catalyst with the working body. Secondly, we show that incorporating a catalyst allows the engine to operate in frequency and temperature regimes that are not accessible for noncatalytic two-stroke engines. We conclude with a general conjecture about the advantage brought by a catalyst: including the catalyst with the working body always allows to improve efficiency over the noncatalytic scenario for any microscopic two-stroke heat engines. We prove this conjecture for two-stroke engines where the working body is composed of two d-level systems initialized in thermal states at two distinct temperatures, as long as the final joint state leading to optimal efficiency in the noncatalytic scenario is not a product state, or at least one of the d-level system is not thermal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantification of the Information Limit of Transmission Electron Microscopes

The resolving power of high-resolution transmission electron microscopes is characterized by the information limit, which reflects the size of the smallest object detail observable with a particular instrument. We introduce a highly accurate measurement method for the information limit, which is suitable for modern aberration-corrected electron microscopes. An experimental comparison with the traditionally applied Young's fringe method yields severe discrepancies and confirms theoretical considerations according to which the Young's fringe method does not reveal the information limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Emulation of anamorphic imaging on the SHARP extreme ultraviolet mask microscope

The SHARP high-numerical aperture actinic reticle review project is a synchrotron-based, extreme ultraviolet (EUV) microscope dedicated to photomask research. SHARP emulates the illumination and imaging conditions of current EUV lithography scanners and those several generations into the future. An anamorphic imaging optic with increased mask-side numerical aperture (NA) in the horizontal and increased demagnification in the vertical direction has been proposed in this paper to overcome limitations of current multilayer coatings and extend EUV lithography beyond 0.33 NA. Zoneplate lenses with an anamorphic 4×/8× NA of 0.55 are fabricated and installed in the SHARP microscope to emulate anamorphic imaging. SHARP’s Fourier synthesis illuminator with a range of angles exceeding the collected solid angle of the newly designed elliptical zoneplates can produce arbitrary angular source spectra matched to anamorphic imaging. A target with anamorphic dense features down to 50-nm critical dimension is fabricated using 40 nm of nickel as the absorber. In a demonstration experiment, anamorphic imaging at 0.55 4×/8× NA and 6 deg central ray angle (CRA) is compared with conventional imaging at 0.5 4× NA and 8 deg CRA. A significant contrast loss in horizontal features is observed in the conventional images. Finally, the anamorphic images show the same image quality in the horizontal and vertical directions.

36 MATERIALS SCIENCE↗

A hard x-ray KB-FZP microscope for tomography with sub-100-nm resolution

An instrument for high-resolution imaging and tomography has been built at the APS beamline 34 ID-C, Argonne National Laboratory. In-line phase contrast tomography can be performed with micrometer resolution. For imaging and tomography with resolution better than 100nm a hard X-ray microscope has been integrated to the instrument. It works with a Kirkpatrick-Baez (KB) mirror as condenser and a Fresnel-Zone plate (FZP) as an objective lens. 50 nm-features have been resolved in a Nickel structure operating the microscope at a photon energy of 9keV. Phase objects with negligible absorption contrast have been imaged. Tomography scans were performed on photonic crystals.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Four-frequency polarizing microscope for recording plasma images in the wavelength range 0.4-1.1 {mu}m

The optical scheme and design of a four-frequency polarizing microscope intended for simultaneous recording of plasma images in the wavelength range 0.4-1.1 {mu}m with the spatial resolution 12 {mu}m in the entire spectral range are described. The effectiveness of such a microscope in studies of plasmas produced on interaction of laser radiation with a target is demonstrated. The plasma images are obtained at the frequencies {omega}{sub 0}, (3/2){omega}{sub 0}, 2{omega}{sub 0}, and (5/2){omega}{sub 0}, where {omega}{sub 0} corresponds to the frequency of heating radiation. The transformation coefficient that characterizes the efficiency of conversion of heating radiation into the 2{omega}{sub 0}, (3/2){omega}{sub 0}, and (5/2){omega}{sub 0} harmonics generated in the plasma is determined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Response function and optimum configuration of semiconductor backscattered-electron detectors for scanning electron microscopes

A new highly efficient design for semiconductor detectors of intermediate-energy electrons (1-50 keV) for application in scanning electron microscopes is proposed. Calculations of the response function of advanced detectors and control experiments show that the efficiency of the developed devices increases on average twofold, which is a significant positive factor in the operation of modern electron microscopes in the mode of low currents and at low primary electron energies.

36 MATERIALS SCIENCE↗

Inspection of commercial optical devices for data storage using a three Gaussian beam microscope interferometer

Recently, an interferometric profilometer based on the heterodyning of three Gaussian beams has been reported. This microscope interferometer, called a three Gaussian beam interferometer, has been used to profile high quality optical surfaces that exhibit constant reflectivity with high vertical resolution and lateral resolution near {lambda}. We report the use of this interferometer to measure the profiles of two commercially available optical surfaces for data storage, namely, the compact disk (CD-R) and the digital versatile disk (DVD-R). We include experimental results from a one-dimensional radial scan of these devices without data marks. The measurements are taken by placing the devices with the polycarbonate surface facing the probe beam of the interferometer. This microscope interferometer is unique when compared with other optical measuring instruments because it uses narrowband detection, filters out undesirable noisy signals, and because the amplitude of the output voltage signal is basically proportional to the local vertical height of the surface under test, thus detecting with high sensitivity. We show that the resulting profiles, measured with this interferometer across the polycarbonate layer, provide valuable information about the track profiles, making this interferometer a suitable tool for quality control of surface storage devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Europa Luminescence Microscope

The Europa Luminescence Microscope (ELM) is an automated fluorescence and dark-field mi-croscope designed to meet key objectives defined in the NASA Europa Lander Study Report, includ-ing the identification and characterization of morphological biosignatures. ELM’s heritage stems from a 2U cubesat fluorescence microscope, the Fluorescence Analysis for In-situ Research (FLAIR) im-ager, designed and built at NASA Ames Research Center, for the autonomous study of microbial bi-ology in low Earth orbit. For the ELM implementation, a sample is autonomously manipulated with a microfluidic system using in-line filter sets to capture successively smaller particles on 10, 1.0, and 0.1 µm pore-size filters for imaging. For darkfield imaging, ELM uses ultraviolet and visible light to image organic and inorganic structures with submicron resolution. The ability to detect structural and chemical biosignatures as small as 0.2 µm in size is achieved by imaging native fluorescence and us-ing fluorescence microscopy stains to identify key molecular and structural indicators of microbial life (proteins, lipids, nucleic acids). To excite fluorescence, ELM uses LEDs with wavelengths centered near 265, 370, 470, and 530 nm and five emission bands. The use of multiple excitation and emission wavelengths for native fluorescence imaging not only enables the detection of different molecular species, but also their rough classification. Excitation at 265 nm allows for the detection of smaller polyaromatic hydrocarbons (PAHs; 1-5 rings), aromatic amino acids, and proteins with little to no interference from mineral fluorescence, given proper emission band selection. 370 and 470 nm light excites increasingly larger PAH structures (e.g., coronene) and larger aromatic biomolecules that may be present (e.g., protective pigments). Similarly, inorganic fluorescence can be characterized and sep-arated from organic fluorescence, allowing the recognition and in some cases classification, of miner-als and other abiotic particles. ELM is based upon work supported by the NASA COLDTech and ICEE-2 programs.

Microscope↗

Toward the fabrication of a 5 μm resolution Wolter microscope for the National Ignition Facility

Advancements in computer-controlled polishing, metrology, and replication have led to a x-ray mirror fabrication process that is capable of producing high-resolution Wolter microscopes. The mirror is a nickel-cobalt replicated full-shell mirror that was electroformed from a finely figured and polished mandrel. This mandrel was designed and fabricated for a 8 m source-to-detector distance microscope, with 10× magnification. A computer controlled polishing process corrected the low-frequency mandrel figure to < 2.0 nm RMS error. The mandrel design was optimized to reduce shell distortions that occur mainly < 20 mm from the shell ends. This design, in combination with improved replication tooling design and refined bath parameters informed by a detailed COMSOL model, have led to reductions in replication errors in the mirror shell. X-ray tests performed on a pair of mirror shells replicated from the mandrel have demonstrated < 10 μm FWHM source plane imaging resolution. Here we discuss the development process, highlight results from metrology and x-ray testing, and define a path for achieving 5 μm FWHM resolution.

Grazing Incidence, Wolter Microscope, X-ray Optics↗

Quantitative imaging of graphene impedance with the near-field scanning microwave microscope.

Graphene has emerged as a promising material for high speed nano-electronics due to the relatively high carrier mobility that can be achieved. To further investigate electronic transport in graphene and reveal its potential for microwave applications, we employed a near-field scanning microwave microscope with the probe formed by an electrically open end of a 4 GHz half-lambda parallel-strip transmission line resonator. Because of the balanced probe geometry, our microscope allows for truly localized quantitative characterization of various bulk and low-dimensional materials, with the response region defined by the one micron spacing between the two metallic strips at the probe tip. The single- and few-layer graphene flakes were fabricated by a mechanical cleavage method on 300-nm-thick silicon dioxide grown on low resistivity Si wafer. The flake thickness was determined using both AFM and Raman microscopies. We observe clear correlation between the near-field microwave and far-field optical images of graphene produced by the probe resonant frequency shift and thickness-defined color gradation, respectively. We show that the microwave response of graphene flakes is determined by the local sheet impedance, which is found to be predominantly active. Furthermore, we apply a quantitative electrodynamic model relating the probe resonant frequency shift to 2D conductivity of single- and few-layer graphene. From fitting a model to the experimental data we evaluate graphene sheet resistance as a function of thickness. Near-field scanning microwave microscopy can simultaneously image location, geometry, thickness, and distribution of electrical properties of graphene without a need for device fabrication. The approach may be useful for design of graphene-based microwave transistors, quality control of large area graphene sheets, or investigation of chemical and electrical doping effects on graphene transport properties. We acknowledge support from the DOE Center for Integrated Nanotechnologies user support program (grant No.U2008A061), from the NASA NM Space Grant Consortium program, and from the LANL-NMT MOU program supported by UCDRD.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Use of Microscopes and Telescopes in IR Imaging

A wide selection of lenses is very useful to the thermographer working in a research environment, where applications can vary from week to week. Both wide angle and telephoto infrared lenses are widely used alternatives to the standard lenses typically supplied by IR camera manufacturers. However, in some extreme applications the need arises for additional image magnification. In these cases, the thermographer must rely on an IR microscope for close-up work with a field of view on the order of 1.3 to 15.8 mm, or a telescope for working at a distance on the order of meters or kilometers. The advantages of using an IR microscope and reflecting telescope will be discussed, as well as the challenges and characteristics of using these instruments.

99 GENERAL AND MISCELLANEOUS↗

Inspection 13.2 nm table-top full-field microscope

We present results on a table-top microscope that uses an EUV stepper geometry to capture full-field images with a halfpitch spatial resolution of 55 nm. This microscope uses a 13.2 nm wavelength table-top laser for illumination and acquires images of reflective masks with exposures of 20 seconds. These experiments open the path to the realization of high resolution table-top imaging systems for actinic defect characterization.

36 MATERIALS SCIENCE↗