Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “medical image processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Adsorption separation of heavier isotope gases in subnanometer carbon pores

Isotopes of heavier gases including carbon ( 13 C/ 14 C), nitrogen ( 13 N), and oxygen ( 18 O) are highly important because they can be substituted for naturally occurring atoms without significantly perturbing the biochemical properties of the radiolabelled parent molecules. These labelled molecules are employed in clinical radiopharmaceuticals, in studies of brain disease and as imaging probes for advanced medical imaging techniques such as positron-emission tomography (PET). Established distillation-based isotope gas separation methods have a separation factor ( S ) below 1.05 and incur very high operating costs due to high energy consumption and long processing times, highlighting the need for new separation technologies. Here, we show a rapid and highly selective adsorption-based separation of 18 O 2 from 16 O 2 with S above 60 using nanoporous adsorbents operating near the boiling point of methane (112 K), which is accessible through cryogenic liquefied-natural-gas technology. A collective-nuclear-quantum effect difference between the ordered 18 O 2 and 16 O 2 molecular assemblies confined in subnanometer pores can explain the observed equilibrium separation and is applicable to other isotopic gases.

36 MATERIALS SCIENCE↗

Automatic tool alignment in a backscatter X-ray scanning system

Technologies pertaining to backscatter x-ray scanning systems are described herein. The backscatter x-ray scanning system includes an x-ray source, which directs collimated x-rays along a plurality of output vectors towards a target. A detector detects diffusely reflected x-rays subsequent to respective collimated x-rays impacting the target, and outputs signals indicative of parameters of the detected x-rays. An image processing system generates an x-ray image based upon parameters of the detected x-rays, wherein each pixel in the image corresponds to a respective output vector. A user selects a particular portion of the image, and a medical device is positioned such that its directional axis is coincident with the output vector corresponding to at least one pixel in the portion of the image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation of columnar CsI x-ray detector responses obtained with hybridMANTIS, a CPU-GPU Monte Carlo code for coupled x-ray, electron, and optical transport

Purpose: hybridMANTIS is a Monte Carlo package for modeling indirect x-ray imagers using columnar geometry based on a hybrid concept that maximizes the utilization of available CPU and graphics processing unit processors in a workstation. Methods: The authors compare hybridMANTIS x-ray response simulations to previously published MANTIS and experimental data for four cesium iodide scintillator screens. These screens have a variety of reflective and absorptive surfaces with different thicknesses. The authors analyze hybridMANTIS results in terms of modulation transfer function and calculate the root mean square difference and Swank factors from simulated and experimental results. Results: The comparison suggests that hybridMANTIS better matches the experimental data as compared to MANTIS, especially at high spatial frequencies and for the thicker screens. hybridMANTIS simulations are much faster than MANTIS with speed-ups up to 5260. Conclusions: hybridMANTIS is a useful tool for improved description and optimization of image acquisition stages in medical imaging systems and for modeling the forward problem in iterative reconstruction algorithms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DeepMC: a deep learning method for efficient Monte Carlo beamlet dose calculation by predictive denoising in magnetic resonance-guided radiotherapy

Abstract Emerging magnetic resonance (MR) guided radiotherapy affords significantly improved anatomy visualization and, subsequently, more effective personalized treatment. The new therapy paradigm imposes significant demands on radiation dose calculation quality and speed, creating an unmet need for the acceleration of Monte Carlo (MC) dose calculation. Existing deep learning approaches to denoise the final plan MC dose fail to achieve the accuracy and speed requirements of large-scale beamlet dose calculation in the presence of a strong magnetic field for online adaptive radiotherapy planning. Our deep learning dose calculation method, DeepMC, addresses these needs by predicting low-noise dose from extremely noisy (but fast) MC-simulated dose and anatomical inputs, thus enabling significant acceleration. DeepMC simultaneously reduces MC sampling noise and predicts corrupted dose buildup at tissue-air material interfaces resulting from MR-field induced electron return effects. Here we demonstrate our model’s ability to accelerate dose calculation for daily treatment planning by a factor of 38 over traditional low-noise MC simulation with clinically meaningful accuracy in deliverable dose and treatment delivery parameters. As a post-processing approach, DeepMC provides compounded acceleration of large-scale dose calculation when used alongside established MC acceleration techniques in variance reduction and graphics processing unit-based MC simulation.

Engineering↗

Novel Myocardial PET/CT Receptor Imaging and Potential Therapeutic Targets

Purpose of the Review: Activation of myocardial cannabinoid type 1 receptors (CB1-R) and/or angiotensin II type 1 receptors (AT1-R) likely plays an important mechanistic role in determining the left-ventricular remodeling process in systolic heart failure. We provide an overview on novel radiotracer probes and positron emission tomography (PET)/computed tomography (CT) imaging to noninvasively probe the expression of myocardial CB1-R and/or AT1-R. Recent Findings: Recent translational investigations have demonstrated the feasibility of {sup 11}C-OMAR or {sup 11}C-KR31173 and PET/CT to image and quantify myocardial CB1-R and/or AT1-R expression, respectively. There is an increasing understanding of the mechanisms of activated myocardial CB1-R and/or AT1-R to influence the left-ventricular remodeling process in systolic heart failure in different disease entities. Summary: The review summarizes contributions of PET to image myocardial CB1-R and AT1-R expression that may have the potential to serve as a target to tailor preventive medical care in the individual patient.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An image-driven machine learning approach to kinetic modeling of a discontinuous precipitation reaction

Micrograph quantification is an essential component of several materials science studies. Machine learning methods, in particular convolutional neural networks, have previously demonstrated performance in image recognition tasks across several disciplines (e.g. materials science, medical imaging, facial recognition). Here, we apply these well-established methods to develop an approach to microstructure quantification for kinetic modeling of a discontinuous precipitation reaction in a case study on the uranium-molybdenum system. Prediction of material processing history based on image data (classification), calculation of area fraction of phases present in the micrographs (segmentation), and kinetic modeling from segmentation results were performed. Results indicate that convolutional neural networks represent microstructure image data well, and segmentation using the k-means clustering algorithm yields results that agree well with manually annotated images. Classification accuracies of original and segmented images are both 94% for a 5-class classification problem. Kinetic modeling results agree well with previously reported data using manual thresholding. The image quantification and kinetic modeling approach developed and presented here aims to reduce researcher bias introduced into the characterization process, and allows for leveraging information in limited image data sets.

36 MATERIALS SCIENCE↗

Chromosome Analysis

Perceptive Scientific Instruments, Inc., provides the foundation for the Powergene line of chromosome analysis and molecular genetic instrumentation. This product employs image processing technology from NASA's Jet Propulsion Laboratory and image enhancement techniques from Johnson Space Center. Originally developed to send pictures back to earth from space probes, digital imaging techniques have been developed and refined for use in a variety of medical applications, including diagnosis of disease.

Source record↗

Helical Tomotherapy Quality Assurance

Helical tomotherapy uses a dynamic delivery in which the gantry, treatment couch, and multileaf collimator leaves are all in motion during treatment. This results in highly conformal radiotherapy, but the complexity of the delivery is partially hidden from the end-user because of the extensive integration and automation of the tomotherapy control systems. This presents a challenge to the medical physicist who is expected to be both a system user and an expert, capable of verifying relevant aspects of treatment delivery. A related issue is that a clinical tomotherapy planning system arrives at a customer's site already commissioned by the manufacturer, not by the clinical physicist. The clinical physicist and the manufacturer's representative verify the commissioning at the customer site before acceptance. Theoretically, treatment could begin immediately after acceptance. However, the clinical physicist is responsible for the safe and proper use of the machine. In addition, the therapists and radiation oncologists need to understand the important machine characteristics before treatment can proceed. Typically, treatment begins about 2 weeks after acceptance. This report presents an overview of the tomotherapy system. Helical tomotherapy has unique dosimetry characteristics, and some of those features are emphasized. The integrated treatment planning, delivery, and patient-plan quality assurance process is described. A quality assurance protocol is proposed, with an emphasis on what a clinical medical physicist could and should check. Additionally, aspects of a tomotherapy quality assurance program that could be checked automatically and remotely because of its inherent imaging system and integrated database are discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Daily QA of linear accelerators using only EPID and OBI

Purpose: As treatment delivery becomes more complex, there is a pressing need for robust quality assurance (QA) tools to improve efficiency and comprehensiveness while simultaneously maintaining high accuracy and sensitivity. This work aims to present the hardware and software tools developed for comprehensive QA of linear accelerator (LINAC) using only electronic portal imaging devices (EPIDs) and kV flat panel detectors. Methods: A daily QA phantom, which includes two orthogonally positioned phantoms for QA of MV-beams and kV onboard imaging (OBI) is suspended from the gantry accessory holder to test both geometric and dosimetric components of a LINAC and an OBI. The MV component consists of a 0.5 cm water-equivalent plastic sheet incorporating 11 circular steel plugs for transmission measurements through multiple thicknesses and one resolution plug for MV-image quality testing. The kV-phantom consists of a Leeds phantom (TOR-18 FG phantom supplied by Varian) for testing low and high contrast resolutions. In the developed process, the existing LINAC tools were used to automate daily acquisition of MV and kV images and software tools were developed for simultaneous analysis of these images. A method was developed to derive and evaluate traditional QA parameters from these images [output, flatness, symmetry, uniformity, TPR{sub 20/10}, and positional accuracy of the jaws and multileaf collimators (MLCs)]. The EPID-based daily QA tools were validated by performing measurements on a detuned 6 MV beam to test its effectiveness in detecting errors in output, symmetry, energy, and MLC positions. The developed QA process was clinically commissioned, implemented, and evaluated on a Varian TrueBeam LINAC (Varian Medical System, Palo Alto, CA) over a period of three months. Results: Machine output constancy measured with an EPID (as compared against a calibrated ion-chamber) is shown to be within ±0.5%. Beam symmetry and flatness deviations measured using an EPID and a 2D ion-chamber array agree within ±0.5% and ±1.2% for crossline and inline profiles, respectively. MLC position errors of 0.5 mm can be detected using a picket fence test. The field size and phantom positioning accuracy can be determined within 0.5 mm. The entire daily QA process takes ∼15 min to perform tests for 5 photon beams, MLC tests, and imaging checks. Conclusions: The exclusive use of EPID-based QA tools, including a QA phantom and simultaneous analysis software tools, has been demonstrated as a viable, efficient, and comprehensive process for daily evaluation of LINAC performance.

60 APPLIED LIFE SCIENCES↗

TH-EF-207A-03: Photon Counting Implementation Challenges Using An Electron Multiplying Charged-Coupled Device Based Micro-CT System

Purpose: To successfully implement and operate a photon counting scheme on an electron multiplying charged-coupled device (EMCCD) based micro-CT system. Methods: We built an EMCCD based micro-CT system and implemented a photon counting scheme. EMCCD detectors use avalanche transfer registries to multiply the input signal far above the readout noise floor. Due to intrinsic differences in the pixel array, using a global threshold for photon counting is not optimal. To address this shortcoming, we generated a threshold array based on sixty dark fields (no x-ray exposure). We calculated an average matrix and a variance matrix of the dark field sequence. The average matrix was used for the offset correction while the variance matrix was used to set individual pixel thresholds for the photon counting scheme. Three hundred photon counting frames were added for each projection and 360 projections were acquired for each object. The system was used to scan various objects followed by reconstruction using an FDK algorithm. Results: Examination of the projection images and reconstructed slices of the objects indicated clear interior detail free of beam hardening artifacts. This suggests successful implementation of the photon counting scheme on our EMCCD based micro-CT system. Conclusion: This work indicates that it is possible to implement and operate a photon counting scheme on an EMCCD based micro-CT system, suggesting that these devices might be able to operate at very low x-ray exposures in a photon counting mode. Such devices could have future implications in clinical CT protocols. NIH Grant R01EB002873; Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗

The application of projected conjugate gradient solvers on graphical processing units

Graphical processing units introduce the capability for large scale computation at the desktop. Presented numerical results verify that efficiencies and accuracies of basic linear algebra subroutines of all levels when implemented in CUDA and Jacket are comparable. But experimental results demonstrate that the basic linear algebra subroutines of level three offer the greatest potential for improving efficiency of basic numerical algorithms. We consider the solution of the multiple right hand side set of linear equations using Krylov subspace-based solvers. Thus, for the multiple right hand side case, it is more efficient to make use of a block implementation of the conjugate gradient algorithm, rather than to solve each system independently. Jacket is used for the implementation. Furthermore, including projection from one system to another improves efficiency. A relevant example, for which simulated results are provided, is the reconstruction of a three dimensional medical image volume acquired from a positron emission tomography scanner. Efficiency of the reconstruction is improved by using projection across nearby slices.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TH-D-16A-01: Medical Physics Workshop: Editorial Vision and Guidance On Writing and Reviewing Papers

On January 1, 2014, editorial leadership of Medical Physics passed from esteemed long-time Editor Bill Hendee to a collective editorial group composed of the three presenters listed above. In this presentation, we would like to outline our vision for the future of Medical Physics and review recent work-in-progress initiatives to implement this vision. Finally, we will close with guidance to authors on how to write a good Medical Physics paper. Vision for Medical Physics and current initiatives: Jeff Williamson, Editor-in-Chief We cannot improve on Dr. Hendee's succinct vision statement “to continue the Journal's tradition of publishing the very best science that propels our discipline forward and improves our contribution to patient care.” More concretely, the Journal should be s the preeminent forum for electronic exchange of cutting edge medical physics science. We seek to identify the best contributions in (a) high impact clinical physics innovations; (b) clinical translation and validation of basic science innovations; or (c) cutting edge basic science developments with potential for patient care improvements. Among the challenges and opportunities we face are: are electronic-only and open access publishing; trends towards more interactive, social-media based scientific communities; and diversification of the medical physics research, authorship, and readership domains, including clinical applications quite foreign to core ABR clinical competencies. To address these issues over the next 3 years, we have reduced the size of our Editorial Board and focused its efforts on improving the Journal's impact through 4 working groups (WGs): WG-1: Review process quality and selectivity Creation of 120 member Board of Associate Editors to improve review uniformity by placing Ms. management in fewer hands New reviewer guidelines and templates Answer: “what is the scope of medical physics research?” Recursive taxonomy for tagging review expertise and article contents WG-2 Improving reader experience Redesigning http://MedPhys.org to host interactive features and gateway to electronic issue archive Experimentation with interactive features beginning with “Point/Counterpoint” Data mining and Journal quality evaluation Find out who are audiences are Identify characteristics of high impact articles Measure effectiveness of innovations Outreach to related communities Special issues presenting high-impact work in designated subcommunities Addressing the needs of new research constituencies: engineers, biophysicists, clinicians Guidelines and templates for reviewers and associate editors: Shiva Das, Therapy Physics Editor We will discuss the Med. Phys. review process and a new initiative to create review templates that attempts to address current shortcomings. Template design is informed by the literature on of the review process effectiveness and practices of other journals. Its goals are to provide authors more constructive criticism to improve the manuscript; quantifying perceived importance and potential impact; and providing structured sections that prompt the reviewer to addresses important technical and editorial elements. While the template is recommended to be used, reviewers could alternatively enter their comments in the older free-form style. The expectations of the template are that it will enable consistently thorough, high quality reviews that accurately separate acceptable vs. substandard submissions but continue our tradition of helping authors to enhance papers with high potential. Ultimately, the goal is to reduce variability and subjectivity in the peer-review process, in turn leading to articles with higher research and clinical impact. We will also discuss interesting perspectives from several journals on aspects of the peer-review process such as public input via comments, influence of author-suggested reviewers, and bias in reviewer selection. Writing good scientific papers and responding to critiques: Mitch Goodsitt, Imaging Physics Editor The essential components of the abstract, introduction, methods, discussion and conclusion sections, as well as the desired writing style and style of the figures and tables will be reviewed. Publishable Medical Physics Ms. must include a clear and concise statement of the novelty and clinical and/or scientific importance of their work. Examples of novelty include: new technical solution to an important clinical problem; new generalizable knowledge; or first demonstration that an existing engineering solution solves a clinical problem. Authors must also include: sufficient background information and rationale; enough detail that the work can be reproduced by others; sufficient statistical analysis to refute or validate their hypothesis, how it compares to; is distinct from, and improves upon others' work; and the limitations of their study. When the authors receive critiques from the referees and associate editor, the authors should provide a detailed point-bypoint response to each comment. We now ask that the authors' rebuttal include the text of the original criticism, the authors' response, and the modified text along with the line numbers in the revised article. We also ask that the new text be highlighted in a different font color in the revised submission. These changes and others will be discussed. Their purpose is to facilitate the review process.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

A signature dissimilarity measure for trabecular bone texture in knee radiographs

Purpose: The purpose of this study is to develop a dissimilarity measure for the classification of trabecular bone (TB) texture in knee radiographs. Problems associated with the traditional extraction and selection of texture features and with the invariance to imaging conditions such as image size, anisotropy, noise, blur, exposure, magnification, and projection angle were addressed. Methods: In the method developed, called a signature dissimilarity measure (SDM), a sum of earth mover's distances calculated for roughness and orientation signatures is used to quantify dissimilarities between textures. Scale-space theory was used to ensure scale and rotation invariance. The effects of image size, anisotropy, noise, and blur on the SDM developed were studied using computer generated fractal texture images. The invariance of the measure to image exposure, magnification, and projection angle was studied using x-ray images of human tibia head. For the studies, Mann-Whitney tests with significance level of 0.01 were used. A comparison study between the performances of a SDM based classification system and other two systems in the classification of Brodatz textures and the detection of knee osteoarthritis (OA) were conducted. The other systems are based on weighted neighbor distance using compound hierarchy of algorithms representing morphology (WND-CHARM) and local binary patterns (LBP). Results: Results obtained indicate that the SDM developed is invariant to image exposure (2.5-30 mA s), magnification (x1.00-x1.35), noise associated with film graininess and quantum mottle (<25%), blur generated by a sharp film screen, and image size (>64x64 pixels). However, the measure is sensitive to changes in projection angle (>5 deg.), image anisotropy (>30 deg.), and blur generated by a regular film screen. For the classification of Brodatz textures, the SDM based system produced comparable results to the LBP system. For the detection of knee OA, the SDM based system achieved 78.8% classification accuracy and outperformed the WND-CHARM system (64.2%). Conclusions: The SDM is well suited for the classification of TB texture images in knee OA detection and may be useful for the texture classification of medical images in general.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

NASA spinoffs to bioengineering and medicine

Through the active transfer of technology, the National Aeronautics and Space Administration (NASA) Technology Utilization (TU) Program assists private companies, associations, and government agencies to make effective use of NASA's technological resources to improve U.S. economic competitiveness and to provide societal benefit. Aerospace technology from areas such as digital image processing, space medicine and biology, microelectronics, optics and electrooptics, and ultrasonic imaging have found many secondary applications in medicine. Examples of technology spinoffs are briefly discussed to illustrate the benefits realized through adaptation of aerospace technology to solve health care problems. Successful implementation of new technologies increasingly requires the collaboration of industry, universities, and government, and the TU Program serves as the liaison to establish such collaborations with NASA. NASA technology is an important resource to support the development of new medical products and techniques that will further advance the quality of health care available in the U.S. and worldwide.

Biomedical Engineering/instrumentation/trends↗

A VR-based volumetric medical image segmentation and visualization system with natural human interaction

Volume rendering produces informative two-dimensional (2D) images from a 3-dimensional (3D) volume. It highlights the region of interest and facilitates a good comprehension of the entire data set. However, volume rendering faces a few challenges. First, a high-dimensional transfer function is usually required to differentiate the target from its neighboring objects with subtle variance. Unfortunately, designing such a transfer function is a strenuously trial-and-error process. Second, manipulating/visualizing a 3D volume with a traditional 2D input/output device suffers dimensional limitations. To address all the challenges, we design NUI-VR 2 , a natural user interface-enabled volume rendering system in the virtual reality space. NUI-VR 2 marries volume rendering and interactive image segmentation. It transforms the original volume into a probability map with image segmentation. A simple linear transfer function will highlight the target well in the probability map. More importantly, we set the entire image segmentation and volume rendering pipeline in an immersive virtual reality environment with a natural user interface. NUI-VR 2 eliminates the dimensional limitations in manipulating and perceiving 3D volumes and dramatically improves the user experience.

42 ENGINEERING↗

SU-G-JeP3-04: Estimating 4D CBCT from Prior Information and Extremely Limited Angle Projections Using Structural PCA and Weighted Free-Form Deformation

Purpose: To investigate the feasibility of using structure-based principal component analysis (PCA) motion-modeling and weighted free-form deformation to estimate on-board 4D-CBCT using prior information and extremely limited angle projections for potential 4D target verification of lung radiotherapy. Methods: A technique for lung 4D-CBCT reconstruction has been previously developed using a deformation field map (DFM)-based strategy. In the previous method, each phase of the 4D-CBCT was generated by deforming a prior CT volume. The DFM was solved by a motion-model extracted by global PCA and a free-form deformation (GMM-FD) technique, using data fidelity constraint and the deformation energy minimization. In this study, a new structural-PCA method was developed to build a structural motion-model (SMM) by accounting for potential relative motion pattern changes between different anatomical structures from simulation to treatment. The motion model extracted from planning 4DCT was divided into two structures: tumor and body excluding tumor, and the parameters of both structures were optimized together. Weighted free-form deformation (WFD) was employed afterwards to introduce flexibility in adjusting the weightings of different structures in the data fidelity constraint based on clinical interests. XCAT (computerized patient model) simulation with a 30 mm diameter lesion was simulated with various anatomical and respirational changes from planning 4D-CT to onboard volume. The estimation accuracy was evaluated by the Volume-Percent-Difference (VPD)/Center-of-Mass-Shift (COMS) between lesions in the estimated and “ground-truth” on board 4D-CBCT. Results: Among 6 different XCAT scenarios corresponding to respirational and anatomical changes from planning CT to on-board using single 30° on-board projections, the VPD/COMS for SMM-WFD was reduced to 10.64±3.04%/1.20±0.45mm from 21.72±9.24%/1.80±0.53mm for GMM-FD. Using 15° orthogonal projections, the VPD/COMS was further reduced to 1.91±0.86%/0.31±0.42mm based on SMM-WFD. Conclusion: Compared to GMM-FD technique, the SMM-WFD technique can substantially improve the 4D-CBCT estimation accuracy using extremely small scan angles to provide ultra-fast 4D verification. This work was supported by the National Institutes of Health under Grant No. R01-CA184173 and a research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Scalable pCT Image Reconstruction Delivered as a Cloud Service

We describe a cloud-based medical image reconstruction service designed to meet a real-time and daily demand to reconstruct thousands of images from proton cancer treatment facilities worldwide. Rapid reconstruction of a three-dimensional Proton Computed Tomography (pCT) image can require the transfer of 100 GB of data and use of approximately 120 GPU-enabled compute nodes. The nature of proton therapy means that demand for such a service is sporadic and comes from potentially hundreds of clients worldwide. We thus explore the use of a commercial cloud as a scalable and cost-efficient platform for pCT reconstruction. To address the high performance requirements of this application we leverage Amazon Web Services' GPU-enabled cluster resources that are provisioned with high performance networks between nodes. To support episodic demand, we develop an on-demand multi-user provisioning service that can dynamically provision and resize clusters based on image reconstruction requirements, priorities, and wait times. We compare the performance of our pCT reconstruction service running on commercial cloud resources with that of the same application on dedicated local high performance computing resources. We show that we can achieve scalable and on-demand reconstruction of large scale pCT images for simultaneous multi-client requests, processing images in less than 10 minutes for less than $10 per image.

Cloud computing↗

Auto-segmentation of normal and target structures in head and neck CT images: A feature-driven model-based approach

Purpose: Intensity modulated radiation therapy (IMRT) allows greater control over dose distribution, which leads to a decrease in radiation related toxicity. IMRT, however, requires precise and accurate delineation of the organs at risk and target volumes. Manual delineation is tedious and suffers from both interobserver and intraobserver variability. State of the art auto-segmentation methods are either atlas-based, model-based or hybrid however, robust fully automated segmentation is often difficult due to the insufficient discriminative information provided by standard medical imaging modalities for certain tissue types. In this paper, the authors present a fully automated hybrid approach which combines deformable registration with the model-based approach to accurately segment normal and target tissues from head and neck CT images. Methods: The segmentation process starts by using an average atlas to reliably identify salient landmarks in the patient image. The relationship between these landmarks and the reference dataset serves to guide a deformable registration algorithm, which allows for a close initialization of a set of organ-specific deformable models in the patient image, ensuring their robust adaptation to the boundaries of the structures. Finally, the models are automatically fine adjusted by our boundary refinement approach which attempts to model the uncertainty in model adaptation using a probabilistic mask. This uncertainty is subsequently resolved by voxel classification based on local low-level organ-specific features. Results: To quantitatively evaluate the method, they auto-segment several organs at risk and target tissues from 10 head and neck CT images. They compare the segmentations to the manual delineations outlined by the expert. The evaluation is carried out by estimating two common quantitative measures on 10 datasets: volume overlap fraction or the Dice similarity coefficient (DSC), and a geometrical metric, the median symmetric Hausdorff distance (HD), which is evaluated slice-wise. They achieve an average overlap of 93% for the mandible, 91% for the brainstem, 83% for the parotids, 83% for the submandibular glands, and 74% for the lymph node levels. Conclusions: Our automated segmentation framework is able to segment anatomy in the head and neck region with high accuracy within a clinically-acceptable segmentation time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗