Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Development of a frequency regulation duty-cycle for standardized energy storage performance testing

The US DOE Protocol for uniformly measuring and expressing the performance of energy storage systems, first developed in 2012 through inclusive working group activities, provides standardized methodologies for evaluating an energy storage system’s ability to supply specific services to electrical grids. This article elaborates on the data and decisions behind the duty-cycle used for frequency regulation in this protocol. Analysis of a year of publicly available frequency regulation control signal data from a utility was considered in developing the representative signal for this use case. Moreover, this showed that signal standard deviation can be used as a metric for aggressiveness or rigor. From these data, we select representative 2 h long signals that exhibit nearly all of dynamics of actual usage under two distinct regimens, one for average use and the other for highly aggressive use. Our results were combined into a 24-h duty-cycle comprised of average and aggressive segments. The benefits and drawbacks of the selected duty-cycle are discussed along with its potential implications to the energy storage industry.

25 ENERGY STORAGE↗

Radiometric Measurement Comparisons Using Transfer Radiometers in Support of the Calibration of NASA's Earth Observing System (EOS) Sensors

EOS satellite instruments operating in the visible through the shortwave infrared wavelength regions (from 0.4 micrometers to 2.5 micrometers) are calibrated prior to flight for radiance response using integrating spheres at a number of instrument builder facilities. The traceability of the radiance produced by these spheres with respect to international standards is the responsibility of the instrument builder, and different calibration techniques are employed by those builders. The National Aeronautics and Space Administration's (NASA's) Earth Observing System (EOS) Project Science Office, realizing the importance of preflight calibration and cross-calibration, has sponsored a number of radiometric measurement comparisons, the main purpose of which is to validate the radiometric scale assigned to the integrating spheres by the instrument builders. This paper describes the radiometric measurement comparisons, the use of stable transfer radiometers to perform the measurements, and the measurement approaches and protocols used to validate integrating sphere radiances. Stable transfer radiometers from the National Institute of Standards and Technology, the University of Arizona Optical Sciences Center Remote Sensing Group, NASA's Goddard Space Flight Center, and the National Research Laboratory of Metrology in Japan, have participated in these comparisons. The approaches used in the comparisons include the measurement of multiple integrating sphere lamp levels, repeat measurements of select lamp levels, the use of the stable radiometers as external sphere monitors, and the rapid reporting of measurement results. Results from several comparisons are presented. The absolute radiometric calibration standard uncertainties required by the EOS satellite instruments are typically in the +/- 3% to +/- 5% range. Preliminary results reported during eleven radiometric measurement comparisons held between February 1995 and May 1998 have shown the radiance of integrating spheres agreed to within +/- 2.5% from the average at blue wavelengths and to within +/- 1.7% from the average at red and near infrared wavelengths. This level of agreement lends confidence in the use of the transfer radiometers in validating the radiance scales assigned by EOS instrument calibration facilities to their integrating sphere sources.

Butler, James J.↗

Fermionic Partial Tomography via Classical Shadows

Here we propose a tomographic protocol for estimating any k-body reduced density matrix (k-RDM) of an n-mode fermionic state, a ubiquitous step in near-term quantum algorithms for simulating many-body physics, chemistry, and materials. Our approach extends the framework of classical shadows, a randomized approach to learning a collection of quantum-state properties, to the fermionic setting. Our sampling protocol uses randomized measurement settings generated by a discrete group of fermionic Gaussian unitaries, implementable with linear-depth circuits. We prove that estimating all k-RDM elements to additive precision ϵ requires on the order of ($^{n}_{k}$)k 3/2 log(n)/ϵ 2 repeated state preparations, which is optimal up to the logarithmic factor. Furthermore, numerical calculations show that our protocol offers a substantial improvement in constant overheads for k ≥ 2, as compared to prior deterministic strategies. We also adapt our method to particle-number symmetry, wherein the additional circuit depth may be halved at the cost of roughly 2–5 times more repetitions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

AERONET-OC: Strengths and Weaknesses of a Network for the Validation of Satellite Coastal Radiometric Products

The Ocean Color component of the Aerosol Robotic Network (AERONET-OC) has been implemented to support long-term satellite ocean color investigations through cross-site consistent and accurate measurements collected by autonomous radiometer systems deployed on offshore fixed platforms. The ultimate purpose of AERONET-OC is the production of standardized measurements performed at different sites with identical measuring systems and protocols, calibrated using a single reference source and method, and processed with the same code. The AERONET-OC primary data product is the normalized water leaving radiance determined at center-wavelengths of interest for satellite ocean color applications, with an uncertainty lower than 5% in the blue-green spectral regions and higher than 8% in the red. Measurements collected at 6 sites counting the northern Adriatic Sea, the Baltic Proper, the Gulf of Finland, the Persian Gulf, and, the northern and southern margins of the Middle Atlantic Bay, have shown the capability of producing quality assured data over a wide range of bio-optical conditions including Case-2 yellow substance- and sedimentdominated waters. This work briefly introduces network elements like: deployment sites, measurement method, instrument calibration, processing scheme, quality-assurance, uncertainties, data archive and products accessibility. Emphases is given to those elements which underline the network strengths (i.e., mostly standardization of any network element) and its weaknesses (i.e., the use of consolidated, but old-fashioned technology). The work also addresses the application of AERONET-OC data to the validation of primary satellite radiometric products over a variety of complex coastal waters and finally provides elements for the identification of new deployment sites most suitable to support satellite ocean color missions.

Zibordi, Giuseppe↗

SU-F-P-09: A Global Medical Physics Collaboration for Implementation of Modern Radiotherapy in Botswana

Purpose: The global burden of cancer is considerable, particularly in low and middle-income countries. Massachusetts General Hospital (MGH) and Botswana-Harvard AIDS Institute have partnered with the oncology community and government of Botswana to form BOTSOGO (BOTSwana Oncology Global Outreach) to address the rising burden of cancer in Botswana. Currently, radiation therapy (RT) is only available at a single linear accelerator (LINAC) in Gaborone Private Hospital (GPH). BOTSOGO worked to limit the absence of RT during a LINAC upgrade and ensure a safe transition to modern radiotherapy techniques. Methods: The existing Elekta Precise LINAC was decommissioned in November 2015 and replaced with a new Elekta VERSA-HD with IMRT/VMAT/CBCT capability. Upgraded treatment planning and record-and-verify systems were also installed. Physicists from GPH and MGH collaborated during an intensive on-site visit in Botswana during the commissioning process. Measurements were performed using newly purchased Sun Nuclear equipment. Photon beams were matched with an existing model to minimize the time needed for beam modeling and machine down time. Additional remote peer review was also employed. Independent dosimetry was performed by irradiating OSLDs, which were subsequently analyzed at MGH. Results: Photon beam quality agreed with reference data within 0.2%. Electron beam data agreed with example clinical data within 3%. Absolute dose calibration was performed using both IAEA and AAPM protocols. Absolute dose measurements with OSLDs agreed within 5%. Quentry cloud-based software was installed to facilitate remote review of treatment plans. Patient treatments resumed in February 2016. The time without RT was reduced, therefore likely resulting in reduced patient morbidity/mortality. Conclusion: A global physics collaboration was utilized to commission a modern LINAC in a resource-constrained setting. This can be a useful model in other areas with limited resources. Further use of technology and on-site exchanges will facilitate the introduction of more advanced techniques in Botswana. We acknowledge funding support from the AAPM International Educational Activities Committee and the NCI Federal Share Proton Beam Program Income Grant.

60 APPLIED LIFE SCIENCES↗

A Novel Sensor Platform Matching the Improved Version of IPMVP Option C for Measuring Energy Savings

It is easy to measure energy consumption with a power meter. However, energy savings cannot be directly computed by the powers measured using existing power meter technologies, since the power consumption only reflects parts of the real energy flows. The International Performance Measurement and Verification Protocol (IPMVP) was proposed by the Efficiency Valuation Organization (EVO) to quantify energy savings using four different methodologies of A, B, C and D. Although energy savings can be estimated following the IPMVP, there are limitations on its practical implementation. Moreover, the data processing methods of the four IPMVP alternatives use multiple sensors (thermometer, hygrometer, Occupant information) and power meter readings to simulate all facilities, in order to determine an energy usage benchmark and the energy savings. This study proposes a simple sensor platform to measure energy savings. Using usually the Electronic Product Code (EPC) global standard, an architecture framework for an information system is constructed that integrates sensors data, power meter readings and occupancy conditions. The proposed sensor platform is used to monitor a building with a newly built vertical garden system (VGS). A VGS shields solar radiation and saves on energy that would be expended on air-conditioning. With this platform, the amount of energy saved in the whole facility is measured and reported in real-time. The data are compared with those obtained from detailed measurement and verification (M&V) processes. The discrepancy is less than 1.565%. Using measurements from the proposed sensor platform, the energy savings for the entire facility are quantified, with a resolution of ±1.2%. The VGS gives an 8.483% daily electricity saving for the building. Thus, the results show that the simple sensor platform proposed by this study is more widely applicable than the four complicated IPMVP alternatives and the VGS is an effective tool in reducing the carbon footprint of a building.

vertical garden system (VGS)↗

Constraints on LISA Pathfinder's Self-Gravity: Design Requirements, Estimates and Testing Procedures

LISA Pathfinder satellite was launched on 3 December 2015 toward the Sun Earth first Lagrangian point (L1) where the LISA Technology Package (LTP), which is the main science payload, will be tested. LTP achieves measurements of differential acceleration of free-falling test masses (TMs) with sensitivity below 3 x 10(exp -14) m s(exp -2) Hz(exp - 1/2) within the 130 mHz frequency band in one dimension. The spacecraft itself is responsible for the dominant differential gravitational field acting on the two TMs. Such a force interaction could contribute a significant amount of noise and thus threaten the achievement of the targeted free-fall level. We prevented this by balancing the gravitational forces to the sub nm s(exp -2) level, guided by a protocol based on measurements of the position and the mass of all parts that constitute the satellite, via finite element calculation tool estimates. In this paper, we will introduce the gravitational balance requirements and design, and then discuss our predictions for the balance that will be achieved in flight.

Armano, M.↗

Enhancing Coherence Limits in Superconducting Quantum Systems for Computing and Sensing

This talk will highlight recent efforts at the SQMS Center to develop qudit-based quantum computing architectures using superconducting three-dimensional (3D) cavities, as well as the use of these ultra-coherent cavities for quantum sensing. I will present systematic studies of materials and devices aimed at identifying and mitigating the dominant sources of decoherence—including two-level systems (TLS), quasiparticles, and other noise mechanisms—in both transmons and 3D cavities. These investigations include microwave loss characterization of niobium, tantalum, aluminum, their native oxides, and substrate materials such as silicon and sapphire. By combining measurements on qubits and cavities, we disentangle subsystem-specific loss mechanisms and establish a hierarchy of mitigation strategies, leading to transmon coherence times exceeding one millisecond. I will also discuss studies of quasiparticle dynamics, including quasiparticle bursts observed in qubits operated both above ground and at the Gran Sasso underground laboratory, and the observation that applied magnetic fields can suppress temporal T₁ fluctuations. Building on these advances, we demonstrate a record-coherence two-cell cavity-qudit system with coherence times exceeding 20 milliseconds. Leveraging tunable sideband interactions together with error-resilient protocols, including measurement-based error correction and post-selection, we achieve high-fidelity quantum state control, including the preparation of Fock states up to N=20 with fidelities above 95% and the generation of high-fidelity two-mode entangled states. Finally, I will discuss how these ultra-coherent quantum systems are enabling emerging quantum sensing applications, including searches for dark matter and gravitational waves.

Roy, Tanay [Fermilab] (ORCID:000000019442862X)↗

A multifractal approach to space-filling recovery for PET quantification

Purpose: A new image-based methodology is developed for estimating the apparent space-filling properties of an object of interest in PET imaging without need for a robust segmentation step and used to recover accurate estimates of total lesion activity (TLA). Methods: A multifractal approach and the fractal dimension are proposed to recover the apparent space-filling index of a lesion (tumor volume, TV) embedded in nonzero background. A practical implementation is proposed, and the index is subsequently used with mean standardized uptake value (SUV {sub mean}) to correct TLA estimates obtained from approximate lesion contours. The methodology is illustrated on fractal and synthetic objects contaminated by partial volume effects (PVEs), validated on realistic {sup 18}F-fluorodeoxyglucose PET simulations and tested for its robustness using a clinical {sup 18}F-fluorothymidine PET test–retest dataset. Results: TLA estimates were stable for a range of resolutions typical in PET oncology (4–6 mm). By contrast, the space-filling index and intensity estimates were resolution dependent. TLA was generally recovered within 15% of ground truth on postfiltered PET images affected by PVEs. Volumes were recovered within 15% variability in the repeatability study. Results indicated that TLA is a more robust index than other traditional metrics such as SUV {sub mean} or TV measurements across imaging protocols. Conclusions: The fractal procedure reported here is proposed as a simple and effective computational alternative to existing methodologies which require the incorporation of image preprocessing steps (i.e., partial volume correction and automatic segmentation) prior to quantification.

60 APPLIED LIFE SCIENCES↗

Subcritical Water Extraction of Amino Acids from Atacama Desert Soils

Amino acids are considered organic molecular indicators in the search for extant and extinct life in the Solar System. Extraction of these molecules from a particulate solid matrix, such as Martian regolith, will be critical to their in situ detection and analysis. The goals of this study were to optimize a laboratory amino acid extraction protocol by quantitatively measuring the yields of extracted amino acids as a function of liquid water temperature and sample extraction time and to compare the results to the standard HCl vapor- phase hydrolysis yields for the same soil samples. Soil samples from the Yungay region of the Atacama Desert ( Martian regolith analog) were collected during a field study in the summer of 2005. The amino acids ( alanine, aspartic acid, glutamic acid, glycine, serine, and valine) chosen for analysis were present in the samples at concentrations of 1 - 70 parts- per- billion. Subcritical water extraction efficiency was examined over the temperature range of 30 - 325 degrees C, at pressures of 17.2 or 20.0 MPa, and for water- sample contact equilibration times of 0 - 30 min. None of the amino acids were extracted in detectable amounts at 30 degrees C ( at 17.2 MPa), suggesting that amino acids are too strongly bound by the soil matrix to be extracted at such a low temperature. Between 150 degrees C and 250 degrees C ( at 17.2 MPa), the extraction efficiencies of glycine, alanine, and valine were observed to increase with increasing water temperature, consistent with higher solubility at higher temperatures, perhaps due to the decreasing dielectric constant of water. Amino acids were not detected in extracts collected at 325 degrees C ( at 20.0 MPa), probably due to amino acid decomposition at this temperature. The optimal subcritical water extraction conditions for these amino acids from Atacama Desert soils were achieved at 200 degrees C, 17.2 MPa, and a water- sample contact equilibration time of 10 min.

biomarkers↗

Multifunctional skin-like electronics for quantitative, clinical monitoring of cutaneous wound healing

Non-invasive, biomedical devices have the potential to provide important, quantitative data for the assessment of skin diseases and wound healing. Traditional methods either rely on qualitative visual and tactile judgments of a professional and/or data obtained using instrumentation with forms that do not readily allow intimate integration with sensitive skin near a wound site. In this paper, an electronic sensor platform that can softly and reversibly laminate perilesionally at wounds to provide highly accurate, quantitative data of relevance to the management of surgical wound healing is reported. Clinical studies on patients using thermal sensors and actuators in fractal layouts provide precise time-dependent mapping of temperature and thermal conductivity of the skin near the wounds. Analytical and simulation results establish the fundamentals of the sensing modalities, the mechanics of the system, and strategies for optimized design. The use of this type of “epidermal” electronics system in a realistic clinical setting with human subjects establishes a set of practical procedures in disinfection, reuse, and protocols for quantitative measurement. Finally, the results have the potential to address important unmet needs in chronic wound management.

60 APPLIED LIFE SCIENCES↗

How to achieve patient-centered testing: role of the protocol nurse

Introduction: Patient-centered cardiac testing is predicated on choosing the right test for the right patient. We studied the effects of changing from script-driven scheduling to nurse-driven protocoling of stress tests. Methods and Results: A protocol nurse reviewed records before scheduling and communicated with patients and ordering providers if needed. We found that instituting nurse protocolling of all non-imaging (ETT) and nuclear (MPI) stress tests (N = 3071) resulted in protocol changes in 37% of our patients, and reduced the proportion of tests that could not be performed as scheduled by 56% and cancelations by 71% (P < 0.001 for each). These changes were sustained over two successive 6-month periods following a baseline observation period of 6 months. For MPI, the most frequent nurse interventions were re-protocoling as stress-first MPI (12% of tests), changing test location for clinical reasons (13%), changing stress modality (7%), and care coordination (5%). Conclusions: Changing from script-driven scheduling to protocol nursing contributed measurably to patient-centered testing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MeV-SIMS TOF Imaging of Organic Tissue with Continuous Primary Beam

MeV-SIMS is an emerging mass spectrometry imaging method, which utilizes fast, heavy ions to desorb secondary molecules. High yields and low fragmentation rates of large molecules, associated with the electronic sputtering process, make it particularly useful in biomedical research, where insight into distribution of organic molecules is needed. Since the implementation of MeV-SIMS in to the micro-beam line at the tandem accelerator of Jožef Stefan Institute, MeV-SIMS provided some valuable observations on the distribution of biomolecules in plant tissue, as discussed by Jenčič et al. (Nucl. Inst. Methods Phys. Res. B. 371, 205–210, 2016; Nucl. Inst. Methods Phys. Res. B. 404, 140–145, 2017). However, limited focusing ability of the chlorine ion beam only allowed imaging at the tissue level. In order to surpass shortcomings of the existing method, we introduced a new approach, where we employ a continuous, low-current primary beam. In this mode, we bombard thin samples with a steady chlorine ion flux of approx. 5000 ions/s. After desorbing molecules, chlorine ions penetrate through the thinly cut sample and trigger the time-of-flight “start” signal on a continuous electron multiplier detector, positioned behind the sample. Such bombardment is more effective than previously used pulsing-beam mode, which demanded several orders of magnitude higher primary ion beam currents. Sub-micrometer focusing of low-current primary ion beam allows imaging of biological tissue on a subcellular scale. Simultaneously, new time-of-flight acquisition approach also improves mass resolution by a factor of 5. Within the article, we compare the performance of both methods and demonstrate the application of continuous mode on biological tissue. We also describe the thin sample preparation protocol, necessary for measurements with low primary ion currents. .

74 ATOMIC AND MOLECULAR PHYSICS↗

Evaluation of methods to assess the uncertainty in estimated energy savings

In this work we present a methodology to evaluate the accuracy of methods used to quantify the uncertainty in estimated total energy savings. We focus on savings measurement and verification (M&V) approaches that use a baseline model to characterize energy use, and that forward-project the model for a counterfactual to determine avoided energy use. These approaches are common to the International Performance Measurement and Verification Protocol's (IPMVP's) Option C and Option B. This methodology can be used to evaluate the uncertainty in savings estimates that are due to model error. It has been applied to evaluate two uncertainty estimation methods, including the industry standard ASHRAE Guideline 14 approach. The evaluation used data from 69 commercial buildings and four different baseline models that span daily and hourly granularity, as well as linear and non-linear/non-parametric forms. The findings of this work indicate that the standard methods that are widely used by the M&V community for estimating the total savings uncertainty over the post-installation period tend to underestimate the uncertainty. The tendency to underestimate the uncertainty is stronger for hourly models than for daily models, due to stronger autocorrelation in model residuals at the hourly time scale.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and application of a statistical methodology to evaluate the predictive accuracy of building energy baseline models

This paper documents the development and application of a general statistical methodology to assess the accuracy of baseline energy models, focusing on its application to Measurement and Verification (M&V) of whole-­building energy savings. The methodology complements the principles addressed in resources such as ASHRAE Guideline 14 and the International Performance Measurement and Verification Protocol. It requires fitting a baseline model to data from a ``training period’’ and using the model to predict total electricity consumption during a subsequent ``prediction period.’’ We illustrate the methodology by evaluating five baseline models using data from 29 buildings. The training period and prediction period were varied, and model predictions of daily, weekly, and monthly energy consumption were compared to meter data to determine model accuracy. Several metrics were used to characterize the accuracy of the predictions, and in some cases the best-­performing model as judged by one metric was not the best performer when judged by another metric.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effect of water on nanomechanics of bone is different between tension and compression

Water, an important constituent in bone, resides in different compartments in bone matrix and may impose significant effects on its bulk mechanical properties. However, a clear understanding of the mechanistic role of water in toughening bone is yet to emerge. To address this issue, this study used a progressive loading protocol, coupled with measurements of in situ mineral and collagen fibril deformations using synchrotron X-ray diffraction techniques. Using this unique approach, the contribution of water to the ultrastructural behavior of bone was examined by testing bone specimens in different loading modes (tension and compression) and hydration states (wet and dehydrated). The results indicated that the effect of water on the mechanical behavior of mineral and collagen phases at the ultrastructural level was loading mode dependent and correlated with the bulk behavior of bone. Tensile loading elicited a transitional drop followed by an increase in load bearing by the mineral phase at the ultrastructural level, which was correlated with a strain hardening behavior of bone at the bulk level. Compression loading caused a continuous loss of load bearing by the mineral phase, which was reflected at the bulk level as a strain softening behavior. In addition, viscous strain relaxation and pre-strain reduction were observed in the mineral phase in the presence of water. Taken together, the results of this study suggest that water dictates the bulk behavior of bone by altering the interaction between mineral crystals and their surrounding matrix.

Samuel, Jitin (ORCID:0000000195203350)↗

Nearest-neighbor oxygen distances in liquid water and ice observed by x-ray Raman based extended x-ray absorption fine structure

We report the nearest-neighbor oxygen-oxygen radial distribution function (NN O-O RDF) of room temperature liquid water and polycrystalline ice Ih (-16.8 deg. C) obtained by x-ray Raman based extended x-ray absorption fine structure (EXAFS) spectroscopy. The spectra of the two systems were taken under identical experimental conditions using the same procedures to obtain the NN O-O RDFs. This protocol ensured a measurement of the relative distance distribution with very small systematic errors. The NN O-O RDF of water is found to be more asymmetric (tail extending to longer distances) with longer average distance (2.81 A ring for water and 2.76 A ring for ice) but a slightly shorter peak position (2.70 A ring for water and 2.71 A ring for ice). The refinement also showed a small but significant contribution from the linear O-H-O multiple scattering signal. The high sensitivity to short range distances of the EXAFS probe will set further restrictions to the range of possible models of liquid water.

36 MATERIALS SCIENCE↗

Need for Standardization of EBSD Measurements for Microstructural Characterization of Thin Film Structures

Microstructural characterization of metal thin films includes measurement of grain size, crystallographic texture and misorientation angle across grain boundaries. All of these measurements can be made simultaneously by the use of electron backscatter diffraction (EBSD) in the scanning electron microscope. The use of EBSD measurements to characterize microstructure requires the collection and analysis of thousands of individual diffraction patterns, and the extraction of statistical quantities of interest from the data set. The results depend on the particular analytical procedures used. Since the grains in interconnect structures are often much smaller than those in bulk materials, the measurement and reporting protocols require adaptation of procedures developed for bulk materials. Here we demonstrate results from a specific procedure for collecting and analyzing EBSD data on electrodeposited copper films. We show that without careful controls, the apparent grain size can vary by a factor of two or more, and the time required to acquire the data can differ by hours. The demonstrated practical advantages of EBSD over previously available techniques and the severe effect of experimental parameters on the results support the need for standardization of the methods used for microstructural characterization by use of EBSD.

36 MATERIALS SCIENCE↗