Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measured data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Hypersonic rarefied-flow aerodynamics inferred from Shuttle Orbiter acceleration measurements

Data obtained from multiple flights of sensitive accelerometers on the Space Shuttle Orbiter during reentry have been used to develop an improved aerodynamic model for the Orbiter normal- and axial-force coefficients in hypersonic rarefied flow. The lack of simultaneous atmospheric density measurements was overcome in part by using the ratio of normal-to-axial acceleration, in which density cancels, as a constraint. Differences between the preflight model and the flight-acceleration-derived model in the continuum regime are attributed primarily to real gas effects. New insights are gained into the variation of the force coefficients in the transition between the continuum regime and free molecule flow.

Blanchard, R. C.↗

Ripplon scattering using grating heterodyne spectroscopy

Heterodyne photon spectroscopy was used for the study of the viseo-elastic properties of the liquid interface by studying the scattering from thermal ripplons. A theory of a heterodyne apparatus based on a grating is presented, and the heterodyne condition is given in terms of the parameters of the experimental set-up. Emphasis was placed on the study of the instrumental function and its influence on the measurement data. The instrumental function is not always gaussian, but its functional form depends on the parameters of the experimental set-up. An algorithm is suggested to arrive at the center frequency and half width at half height of the spectrum from the noisy experimental data, and applied to the measurement data obtained from ethanol and water surfaces.

Sirohi, R. S.↗

Methods and devices for preventing computationally explosive calculations in a computer for model parameters distributed on a hierarchy of geometric simplices

A computer-implemented method of preventing computationally explosive calculations. The method includes obtaining, by a processor of the computer, measured data of one of a physical process or a physical object; performing hierarchical numerical modeling of a physical process inclusive of an Earth model containing at least one of (a) infrastructure in the ground and (b) a formation feature in the ground, wherein predicted data is generated; comparing the measured data to the predicted data to calculate an estimated error; analyzing the estimated error via an inversion process to update the at least one of the Earth model and infrastructure model so as to reduce the estimated error and to determine a final composite Earth model of at least one of the infrastructure and the feature; and using the final composite Earth model to characterize at least one of the process and the physical object.

Source record↗

Analysis of NIMBUS-7 SMMR Data

Measurements obtained with the SMMR OF NIMBUS-7 over Hokkaido snow field show that the relationship between snow depth and brightness temperature changes when snow depth becomes deeper than 50 cm. Average brightness temperature of the daytime indicates negative correlations with snow depth except for 6.6 GHz channel data which indicates weak positive correlation.

Tsuchiya, K.↗

Inference of the linear matter power spectrum at z = 0 using DESI DR1 Full-Shape data

Measurements of galaxy distributions at large cosmic distances capture clustering from the past. In this study, we use a cosmological model to translate these observations into the present-day galaxy distribution. Specifically, we reconstruct the 3D linear matter power spectrum at redshift z = 0 using Dark Energy Spectroscopic Instrument (DESI) Year 1 (DR1) galaxy clustering data and Cosmic Microwave Background (CMB) observations, assuming the ΛCDM model, and compare it to the result assuming the w 0 w a CDM model. Building on previous state-of-the-art methods, we apply Effective Field Theory (EFT) modelling of the galaxy power spectrum to account for small-scale effects in the 2-point statistics of galaxy data. Implementation of the EFT approach improves the modelling of the galaxy power spectrum, providing a more robust consistency test of the assumed cosmological model. By casting both CMB and galaxy clustering observations, spanning distinct redshift regimes, into k-space, we can identify discrepancies between the datasets of different redshifts, which would indicate potential inaccuracies in the assumed expansion history. While previous studies have shown consistency with ΛCDM, this work extends the analysis with higher-quality data to further test the expansion histories of both ΛCDM and w 0 w a CDM. Our findings show that both ΛCDM and w 0 w a CDM provide consistent fits to the linear matter power spectrum recovered from DESI DR1 data.

cosmological parameters from LSS↗

Survey of Time Shift Detection Algorithms for Measured PV Data

In this research, three variations of time shift detection algorithms were tested for their ability to detect time shift issues (including daylight savings time and random time shifts) in measured PV data sets. Two algorithms from the Python PVAnalytics package were assessed, and one algorithm from the Solar-Data-Tools package was assessed. Each algorithm's ability to accurately detect and measure time shifts was assessed.

automated preprocessing↗

SCILLA mini-Aerosol Mass Spectrometer (mAMS) airborne data

Measurements of non-refractory, sub-micron aerosol composition, namely organic, sulfate, nitrate, chloride, and ammonium aerosols, by a mini- aerosol mass spectrometer (mAMS, Aerodyne Research, Inc.) are reported. The instrument sampled ambient air through 3 different inlets: unperturbed ambient air, a Counter-flow Virtual Impactor (CVI), and an oxidation flow reactor (OFR). Users should consult the Sampling Key for proper interpretation of the data.

and secondary aerosol in air",total_organics,nitra↗

Particle size distributions in polar mesospheric clouds derived from solar mesosphere explorer measurements

Data from the visible and UV spectrometers on the Solar Mesosphere Explorer are used to derive the color ratios of the reflectance at 265, 296, and 393 nm of light scattered from polar mesospheric cloud particles. This analysis extends the spectral coverage into the visible region of the spectrum. The data reduction technique compared the cloud brightness to the brightness scattered from the background atmosphere at the same wavelength. The ratios determined in this way are independent of systematic errors in instrument radiometric calibration. The data are analyzed using theoretical determinations of the color ratios from the Mie theory of small particle scattering, assuming a lognormal distribution for the particle size dispersion. Here 'size' means the average radius of the sphere having the same ice volume. The present results confirm earlier findings that the effective sizes of polar mesospheric cloud particles are less than 70 nm. Still, there exists a small number of measurements which result in particle sizes of the order of 80 nm. Even for these large particle sizes the required vertical column content of water vapor does not exceed limits imposed by the available atmospheric water vapor concentrations.

Rusch, D. W.↗

Experimental verification of the Acuros XB and AAA dose calculation adjacent to heterogeneous media for IMRT and RapidArc of nasopharygeal carcinoma

Purpose: To compare the doses calculated by the Acuros XB (AXB) algorithm and analytical anisotropic algorithm (AAA) with experimentally measured data adjacent to and within heterogeneous medium using intensity modulated radiation therapy (IMRT) and RapidArc{sup Registered-Sign} (RA) volumetric arc therapy plans for nasopharygeal carcinoma (NPC). Methods: Two-dimensional dose distribution immediately adjacent to both air and bone inserts of a rectangular tissue equivalent phantom irradiated using IMRT and RA plans for NPC cases were measured with GafChromic{sup Registered-Sign} EBT3 films. Doses near and within the nasopharygeal (NP) region of an anthropomorphic phantom containing heterogeneous medium were also measured with thermoluminescent dosimeters (TLD) and EBT3 films. The measured data were then compared with the data calculated by AAA and AXB. For AXB, dose calculations were performed using both dose-to-medium (AXB{sub Dm}) and dose-to-water (AXB{sub Dw}) options. Furthermore, target dose differences between AAA and AXB were analyzed for the corresponding real patients. The comparison of real patient plans was performed by stratifying the targets into components of different densities, including tissue, bone, and air. Results: For the verification of planar dose distribution adjacent to air and bone using the rectangular phantom, the percentages of pixels that passed the gamma analysis with the {+-} 3%/3mm criteria were 98.7%, 99.5%, and 97.7% on the axial plane for AAA, AXB{sub Dm}, and AXB{sub Dw}, respectively, averaged over all IMRT and RA plans, while they were 97.6%, 98.2%, and 97.7%, respectively, on the coronal plane. For the verification of planar dose distribution within the NP region of the anthropomorphic phantom, the percentages of pixels that passed the gamma analysis with the {+-} 3%/3mm criteria were 95.1%, 91.3%, and 99.0% for AAA, AXB{sub Dm}, and AXB{sub Dw}, respectively, averaged over all IMRT and RA plans. Within the NP region where air and bone were present, the film measurements represented the dose close to unit density water in a heterogeneous medium, produced the best agreement with the AXB{sub Dw}. For the verification of point doses within the target using TLD in the anthropomorphic phantom, the absolute percentage deviations between the calculated and measured data when averaged over all IMRT and RA plans were 1.8%, 1.7%, and 1.8% for AAA, AXB{sub Dm} and AXB{sub Dw}, respectively. From all the verification results, no significant difference was found between the IMRT and RA plans. The target dose analysis of the real patient plans showed that the discrepancies in mean doses to the PTV component in tissue among the three dose calculation options were within 2%, but up to about 4% in the bone content, with AXB{sub Dm} giving the lowest values and AXB{sub Dw} giving the highest values. Conclusions: In general, the verification measurements demonstrated that both algorithms produced acceptable accuracy when compared to the measured data. GafChromic{sup Registered-Sign} film results indicated that AXB produced slightly better accuracy compared to AAA for dose calculation adjacent to and within the heterogeneous media. Users should be aware of the differences in calculated target doses between options AXB{sub Dm} and AXB{sub Dw}, especially in bone, for IMRT and RA in NPC cases.

60 APPLIED LIFE SCIENCES↗

AXAF VETA-I mirror encircled energy measurements and data reduction

The AXAF VETA-I mirror encircled energy was measured with a series of apertures and two flow gas proportional counters at five X-ray energies ranging from 0.28 to 2.3 keV. The proportional counter has a thin plastic window with an opaque wire mesh supporting grid. Depending on the counter position, this mesh can cause the X-ray transmission to vary as much as +/-9 percent, which directly translates into an error in the encircled energy. In order to correct this wire mesh effect, window scan measurements were made, in which the counter was scanned in both horizontal (Y) and vertical (Z) directions with the aperture fixed. Post VETA measurement of the VXDS setup were made to determine the exact geometry and position of the mesh grid. Computer models of the window mesh were developed to simulate the X-ray transmission based on this measurement. The window scan data were fitted to such mesh models and corrections were made. After this study, the mesh effect was well understood and the final results of the encircled energy were obtained with an uncertainty of less than 0.8 percent.

Zhao, Ping↗

AXAF VETA-I mirror encircled energy measurements and data reduction

The AXAF VETA-I mirror encircled energy was measured with a series of apertures and two flow gas proportional counters at five X-ray energies ranging from 0.28 to 2.3 keV. The proportional counter has a thin plastic window with an opaque wire mesh supporting grid. Depending on the counter position, this mesh can cause the X-ray transmission to vary as much as +/- 9 percent, which directly translates into an error in the encircled energy. In order to correct this wire mesh effect, window scan measurements were made, in which the counter was scanned in both horizontal (Y) and vertical (Z) directions with the aperture fixed. Post VETA measurement of the VXDS setup were made to determine the exact geometry and position of the mesh grid. Computer models of the window mesh were developed to simulate the X-ray transmission based on this measurement. The window scan data were fitted to such mesh models and corrections were made. After this study, the mesh effect was well understood and the final results of the encircled energy were obtained with an uncertainty of less than 0.8 percent.

Zhao, Ping↗

Tidal Current Cross-flow Turbine Wake ADV and PIV Data

Measurements in the wake of a high-solidity cross-flow turbine in a laboratory flume obtained using Acoustic Doppler Velocimetry and Particle Image Velocimetry for the purposes of characterizing the turbine wake and comparing the methods.

16 TIDAL AND WAVE POWER↗

Research requirements for a real-time flight measurements and data analysis system for subsonic transport high-lift research

A multiphased research program to obtain detailed flow characteristics on a multielement high-lift flap system is being conducted on the Transport Systems Research Vehicle (B737-100 aircraft) at NASA Langley Research Center. Upcoming flight tests have required the development of a highly capable and flexible flight measurement and data analysis instrumentation system. This instrumentation system will be more comprehensive than any of the systems used on previous high-lift flight experiment at NASA Langley. The system will provide the researcher near-real-time information for decision making needed to modify a flight test in order to further examine unexpected flow conditions. This paper presents the research requirements and instrumentation design concept for an upcoming flight experiment for the subsonic transport high-lift research program. The flight experiment objectives, the measurement requirements, the data acquisition system, and the onboard data analysis and display capabilities are described.

Whitehead, Julia H.↗

Data-driven delta-generalized labeled multi-bernoulli tracker

A system and method for tracking a plurality of objects. Unlabeled measurement data identifying a plurality of targets corresponding to the plurality of objects is received. A multi-target likelihood function is generated using a persistent target density, a birth target density, and a clutter density. The multi-target likelihood function is used to associate persistent targets with the unlabeled measurement data to update persistent tracks and to initiate a new track for each target in the plurality of targets in the measurement data that is not associated with a persistent target.

LeGrand, Keith Allen↗

Algorithm for Screening Phasor Measurement Unit Data for Power System Events and Categories and Common Characteristics for Events Seen in Phasor Measurement Unit Relative Phase-Angle Differences and Frequency Signals

A network of multiple phasor measurement units (PMU) was created, set up, and maintained at the University of Texas at Austin to obtain actual power system measurements for power system analysis. Power system analysis in this report covers a variety of time ranges, such as short- term analysis for power system disturbances and their effects on power system behavior and long- term power system behavior using modal analysis. The first objective of this report is to screen the PMU data for events. The second objective of the report is to identify and describe common characteristics extracted from power system events as measured by PMUs. The numerical characteristics for each category and how these characteristics are used to create selection rules for the algorithm are also described. Trends in PMU data related to different levels and fluctuations in wind power output are also examined.

17 WIND ENERGY↗