Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “matching”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

SU-F-J-40: Evaluation of Sensitivity of the Automatic Matching Between Cone-Beam CT Image and Simulation CT Image in TrueBeam 2.0 Imaging System 6DoF Considering Different Uncertainty Sources

Purpose: To estimate the sensitivity of TrueBeam 2.0 Imaging System 6DoF automatic matching tool through the acquisition of cone-beam CT images in different phantoms applying submillimeter translations and rotations of tenths of a degree and registered with image simulation CT. Methods: To evaluate overall system-wide image, we consider two uncertainties source; First, the uncertainty of the manual phantom displacement (ε-m). This uncertainty is calculated by a digital caliper (0.01 mm) for vertical (Vrt), lateral (Lat) and longitudinal (Lng). A digital inclinometer (0.01°) for the pitch and roll and the own phantom scale to evaluate the coordinate rotation (Rtn). The second uncertainty is the displacement detected by the algorithm system of matching (σ-d) that we obtain from the standard deviations of the different measurements. We use three different phantoms. The BrainLab Radiosurgery system for supporting masks with an anthropomorphic dummy adapted to allow displacements of 0.1 mm in Vrt, Lat and Lng dimensions and rotations of 0.1° in Pitch dimension. For the analysis of the Rtn and Roll dimensions we use two homemade phantoms (RinoRot and RinoRoll, La Fe Hospital, Valencia, Spain) that allow rotations of 0.3°. Results: In the case of manual displacement of 0.10 ± 0.03 mm in the translations, the system detect 0.10 ± 0.07 mm, 0.12 ± 0.07 mm and 0.13 ± 0.07 mm (mean ± SD) in Lat, Vrt and Lng respectively. In the case of rotational dimension, manual displacement of 0.3 ± 0.1° was detected with 0.19 ± 0.06°, 0.29 ± 0.03° and 0.27 ± 0.06° in Pitch, Roll and Rtn. Conclusion: We conclude that the sensitivity of the automatic matching system is within 0.10 mm in translations and 0.3° in rotations. These values are under the own sensitivity of the software.

60 APPLIED LIFE SCIENCES↗

SU-F-T-467: A Cross-Checking Approach for Dosimetric Verification of Beam- Matched Elekta Linear Accelerators

Purpose: To verify the similarity of the dosimetric characteristics between two Elekta linear accelerators (linacs) in order to treat patients interchangeably on these two machines without re-planning. Methods: To investigate the viability of matching the 6 MV flattened beam on an existing linac (Elekta Synergy with Agility head) with a recently installed new linca (Elekta Versa HD), percent depth doses (PDD), flatness and symmetry output factors were compared for both machines. To validate the beam matching among machines, we carried out two approaches to cross-check the dosimetrical equivalence: 1) the prior treatment plans were re-computed based on the newly built Versa HD treatment planning system (TPS) model without changing the beam control points; 2) The same plans were delivered on both machines and the radiation dose measurements on a MapCheck2 were compared with TPS calculations. Three VMAT plans (Head and neck, lung, and prostate) were used in the study. Results: The difference between the PDDs for 10×10 cm{sup 2} field at all depths was less than 0.8%. The difference of flatness and symmetry for 30×30 cm{sup 2} field was less than 0.8%, and the measured output factors varies by less than 1% for each field size ranging from 2×2 cm2 to 40×40 cm{sup 2}. For the same plans, the maximum difference of the two calculated dose distributions is 2% of prescription. For the QA measurements, the gamma index passing rates were above 99% for 3%/3mm criteria with 10% threshold for all three clinical plans. Conclusion: A beam modality matching between two Elekta linacs is demonstrated with a cross-checking approach.

43 PARTICLE ACCELERATORS↗

TH-CD-209-03: Feasibility of CBCT-Based Proton Dose Calculation Using a Histogram-Matching Algorithm in Proton Beam Therapy

Purpose: The aim of this study was to confirm On-Board Imager cone-beam computed tomography (CBCT) using a histogram-matching algorithm as a useful method for proton dose calculation in head and neck radiotherapy. Methods: We studied one head and neck phantom and ten patients with head and neck cancer treated using intensity-modulated radiation therapy (IMRT) and proton beam therapy. We modified Hounsfield unit (HU) values of CBCT (mCBCT) using a histogram-matching algorithm. In order to evaluate the accuracy of the proton dose calculation, we compared dose differences in dosimetric parameters (Dmean) for clinical target volume (CTV), planning target volume (PTV) and left parotid and proton ranges (PR) between the planning CT (reference) and CBCT or mCBCT, and gamma passing rates of CBCT and mCBCT. To minimize the effect of organ deformation, we also performed image registration. Results: For patients, the average differences in Dmean for CTV, PTV, and left parotid between planning CT and CBCT were 1.63 ± 2.34%, 3.30 ± 1.02%, and 5.42 ± 3.06%, respectively. Similarly, the average differences between planning CT and mCBCT were 0.20 ± 0.19%, 0.58 ±0.43%, and 3.53 ±2.40%, respectively. The average differences in PR between planning CT and CBCT or mCBCT of a 50° beam for ten patients were 2.1 ± 2.1 mm and 0.3 ± 0.5 mm, respectively. Similarly, the average differences in PR of a 120° beam were 2.9 ± 2.6 mm and 1.1 ± 0.9 mm, respectively. The average dose and PR differences of mCBCT were smaller than those of CBCT. Additionally, the average gamma passing rates of mCBCT were larger than those of CBCT. Conclusion: We evaluated the accuracy of the proton dose calculation in CBCT and mCBCT with the image registration for ten patients. Our results showed that HU modification using a histogram-matching algorithm could improve the accuracy of the proton dose calculation.

60 APPLIED LIFE SCIENCES↗

Parton labeling without matching: unveiling emergent labelling capabilities in regression models

Parton labeling methods are widely used when reconstructing collider events with top quarks or other massive particles. State-of-the-art techniques are based on machine learning and require training data with events that have been matched using simulations with truth information. In nature, there is no unique matching between partons and final state objects due to the properties of the strong force and due to acceptance effects. We propose a new approach to parton labeling that circumvents these challenges by recycling regression models. The final state objects that are most relevant for a regression model to predict the properties of a particular top quark are assigned to said parent particle without having any parton-matched training data. This approach is demonstrated using simulated events with top quarks and outperforms the widely used $χ$ 2 method.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tolerating Correlated Failures for Generalized Cartesian Distributions via Bipartite Matching

Faults are expected to play an increasingly important role in how algorithms and applications are designed to run on future extreme-scale systems. A key ingredient of any approach to fault tolerance is effective support for fault tolerant data storage. A typical application execution consists of phases in which certain data structures are modified while others are read-only. Often, read-only data structures constitute a large fraction of total memory consumed. Fault tolerance for read-only data can be ensured through the use of checksums or parities, without resorting to expensive in-memory duplication or checkpointing to secondary storage. In this paper, we present a graph-matching approach to compute and store parity data for read-only matrices that are compatible with fault tolerant linear algebra (FTLA). Typical approaches only support blocked data distributions with each process holding one block with the parity located on additional processes. The matrices are assumed to be blocked by a cartesian grid with each block assigned to a process. We consider a generalized distribution in which each process can be assigned arbitrary blocks. We also account for the fact that multiple processes might be part of the same failure unit, say an SMP node. The flexibility enabled by our novel application of graph matching extends fault tolerance support to data distributions beyond those supported by prior work. We evaluate the matching implementations and cost to compute the parity and recover lost data, demonstrating the low overhead incurred by our approach.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

2D Polyhedral Template Matching for Atomic Resolution Microscopy

SAND2024-13879O The 2D Polyhedral Template Matching for Atomic Resolution Microscopy is a suite of functions for analyzing atomic resolution electron microscopy images using the 2D polyhedral template matching (2D-PTM) method. This software analyzes atomic resolution microscopy data from electron microscopic imaging or scanning probe microscopies. The primary application is for identifying different crystal phases, crystal orientations, and defect structures obtained in such atomic resolution images. Written in MATLAB and starting from an atomic resolution image, the code identifies the positions of atomic intensity peaks. It then matches predefined structural templates to the local atomic environments. Outputs include the local structural identification, the template scaling factor and rotation angle, root-mean-squared deviation (RMSD), and centrosymmetry parameter.

Medlin, Douglas↗

Differentially Private Map Matching (DPMM) v1.0

Human mobility trajectories provide valuable information for developing mobility applications, as they contain diverse and rich information about the users. User mobility data is valuable for various applications such as intelligent transportation systems (ITS), commercial business models, and disease-spread models. However, such spatio-temporal traces may pose a threat to user privacy. GPS trajectories in their raw form are not suitable for transportation studies, as they require matching locations with nearest road links — a process called map-matching. This software implements a differential privacy (DP)-based map-matching algorithm, called DPMM, that generates link-level location trajectories in a privacy-preserving manner to protect users' origin destinations (OD) and travel paths. OD privacy is achieved by injecting Planar Laplace noise to the user OD GPS points. Travel-path privacy is provided with randomized travel path construction using exponential DP mechanism. The injected noise level is selected adaptively, by considering the link density of the location and the functional category of the localized links. For path privacy, our mechanism samples waypoints and selects candidate paths between waypoints. DPMM provides privacy effectively with respect to link density instead of other trajectory samples in the database compared to other privacy mechanisms. Compared to the different baseline models our DP-based privacy model offers closer query responses to the raw data in terms of individual and aggregate trajectory-level statistics with an average at absolute deviation from the baseline for individual statistics on ϵ = 1.0. Beyond individual trajectory statistics, the DPMM outperforms the other benchmark DP-based mechanisms on different aggregate statistics with up to 8x improvement in utility.

Peisert, Sean [Lawrence Berkeley National Laborato↗

Role of the Porras factor in phase matching of high-order harmonic generation driven by focused few-cycle laser pulses

We investigate the role of the Porras factor (or laser focusing effect) on the macroscopic high-order harmonic generation (HHG) driven by a focused broadband few-cycle laser beam. By employing a non-adiabatic phase-matching analysis method, we reveal that phase mismatch due to the induced-dipole phase varies with the Porras factor, which is dominant in phase matching at low gas pressure. We also find that in a strongly ionized medium when gas pressure is high, the nonlinear propagation is dominated by a plasma effect such that the focusing effect is mitigated, resulting in similar poor phase matching of HHG regardless of the Porras factor. Our results are expected to assist experimentalists identifying optimal conditions for HHG using ultrashort laser pulses.

Optics↗

Improved high-resolution mapping of phase-matching conditions in second-order nonlinear crystals via imaging

Large-aperture nonlinear crystals for frequency conversion and parametric amplification exhibit spatial variations in phase-matching conditions, which affect the performance of high-power laser systems. We demonstrate significant improvements in speed and resolution to a technique that spatially maps these phase-matching conditions using imaging of the beam resulting from detuned second-harmonic generation. The phase-matching conditions at the pyramidal sector boundary of partially deuterated potassium dihydrogen phosphate (DKDP) are mapped with sub-0.1-mm resolution. We examine the effect of further increases in scan rate on the precision of the technique and demonstrate a scan rate of 0.8 cm 2 per minute at the aforementioned resolution.

Wampler, R. [Univ. of Rochester, NY (United States↗

Design and Simulation of a Matching System into the Helical Cooling Channel

Muon colliders could provide the most sensitive measurement of the Higgs mass and return the US back to the Energy Frontier. Central to the capabilities of muon colliders are the cooling channels that provide the extraordinary reduction in emittance required for the precise Higgs mass measurement and increased luminosity for enhanced discovery potential of an Energy Frontier Machine. The Helical Cooling Channel (HCC) is able to achieve such emittance reduction and matching sections within the HCC have been successfully designed in the past with lossless transmission and no emittance growth. However, matching into the HCC from a straight solenoid poses a challenge, since a large emittance beam must cross transition. We elucidate on the challenge and present evaluations of two solutions, along with concepts to integrate the operations of a Charge Separator and match into the HCC.

Yoshikawa, C.↗

STrEAMlining EFT Matching

This paper presents STrEAM (SuperTrace Evaluation Automated for Matching), a Mathematica package that calculates all functional supertraces which arise when matching a generic UV model onto a relativistic Effective Field Theory (EFT) at one loop and to arbitrary order in the heavy mass expansion. STrEAM implements the covariant derivative expansion to automate the most tedious step of the streamlined functional matching prescription presented in Ref. [1]. The code and an example notebook are available at this link.

43 PARTICLE ACCELERATORS↗

Zero modes and matching for the twist-3 PDFs

The quasi-PDF approach, proposed by X. Ji in 2013, has made it possible to directly extract light-cone PDFs from lattice QCD. This approach relies on the extraction of matrix elements of space-like operators for fast-moving hadrons. Quasi-PDFs can be related to the light-cone PDFs through a perturbatively calculable matching coefficient. We explore the formalism of matching, for the very first time, for the twist-3 PDFs g_{T}(x) g T ( x ) , e(x) e ( x ) and h_{L}(x) h L ( x ) . In this work, we address the non-trivialities involved in the extraction of the matching coefficient due to the presence of (singular) zero-mode contributions.

Bhattacharya, Shohini↗

Minimization of spin tune spread by matching dispersion prime at RHIC

At RHIC, the spin polarization is preserved with a pair of Siberian snakes on the oppo- site sides in each ring. The polarized proton beam with finite spin tune spread might cross spin resonances multiple times in two cases, one is when beam going through strong spin intrinsic resonances during acceleration, the other is when sweeping spin flipper’ frequency across the spin tune to flip the direction of spin polarization. The consequence is loss of spin polarization in both cases. Therefore, a scheme of min- imizing the spin tune spread by matching the dispersion primes at the two snakes was introduced based on the fact that the spin tune spread is proportional to the difference of dispersion primes at the two snakes. The scheme was implemented at fixed energies for the spin flipper study and during beam acceleration for better spin polarization transmission efficiency. The effect of minimizing the spin tune spread by matching the dispersion primes was observed and confirmed experimentally. The principle of minimizing the spin tune spread by matching the dispersion primes, the impact on the beam optics, and the effect of a narrower spin tune spread are presented in this report.

43 PARTICLE ACCELERATORS↗

Multivariate Analysis as a Tool for Validating Tester Matching

A method of applying Principal Component Analysis, Soft Independent Modeling of Class Analysis, and statistical analysis is described that can be applied to many types of testers to ascertain how well matched the performance of the testers in the analysis are to one another or how well matched a tester is to itself at a later time. This method is most useful for situations for which the same units have not been run across the testers being analyzed for matched performance.

Multari, Rosalie A [Sandia National Laboratories (↗

TCF Base Commercialization Enabling Final Report: Lab Making Advanced Technology Commercialization Harmonized (MATCH) Prize

The Lab MATCH prize, funded by the Office of Technology Commercialization through the Technology Commercialization Fund, was designed to accelerate the commercialization of national laboratory intellectual property (IP) by incentivizing for-profit companies and startups to license lab IP aiming to enable more affordable, available, reliable and secure energy solutions. The Lab MATCH prize program offers both technical and commercial benefits, aligning with the Department of Energy's (DOE) mission to advance energy solutions through innovation, commercialization, and market-ready deployment. In summary, the Lab MATCH Prize promotes DOE's objectives by marrying technical innovation with commercialization expertise, resulting in scalable, market-ready solutions that strengthen the U.S. economy, advance energy technologies, and reaffirm U.S. leadership in energy innovation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Detecting Weak Spectral Lines in Interferometric Data through Matched Filtering

Modern radio interferometers enable observations of spectral lines with unprecedented spatial resolution and sensitivity. In spite of these technical advances, many lines of interest are still at best weakly detected and therefore necessitate detection and analysis techniques specialized for the low signal-to-noise ratio (S/N) regime. Matched filters can leverage knowledge of the source structure and kinematics to increase sensitivity of spectral line observations. Application of the filter in the native Fourier domain improves S/N while simultaneously avoiding the computational cost and ambiguities associated with imaging, making matched filtering a fast and robust method for weak spectral line detection. We demonstrate how an approximate matched filter can be constructed from a previously observed line or from a model of the source, and we show how this filter can be used to robustly infer a detection significance for weak spectral lines. When applied to ALMA Cycle 2 observations of CH{sub 3}OH in the protoplanetary disk around TW Hya, the technique yields a ≈53% S/N boost over aperture-based spectral extraction methods, and we show that an even higher boost will be achieved for observations at higher spatial resolution. A Python-based open-source implementation of this technique is available under the MIT license at http://github.com/AstroChem/VISIBLE.

79 ASTRONOMY AND ASTROPHYSICS↗

Bayesian Cross-matching of High Proper-motion Stars in Gaia DR2 and Photometric Metallicities for ∼1.7 million K and M Dwarfs

We present a Bayesian method to cross-match 5,827,988 high proper-motion Gaia sources (μ > 40 mas yr{sup −1}) to various photometric surveys: Two Micron All Sky Survey, AllWISE data release from the Wide-field Infrared Explorer (WISE) mission, Galaxy Evolution Explorer, Radial Velocity Experiment, Sloan Digital Sky Survey, and Panoramic Survey Telescope and Rapid Response System (Pan-STARRS). To efficiently associate these objects across catalogs, we develop a technique that compares the multidimensional distribution of all sources in the vicinity of each Gaia star to a reference distribution of random field stars obtained by extracting all sources in a region on the sky displaced 2′. This offset preserves the local field stellar density and magnitude distribution, allowing us to characterize the frequency of chance alignments. The resulting catalog with Bayesian probabilities >95% has a marginally higher match rate than current internal Gaia data release 2 (DR2) matches for most catalogs. However, a significant improvement is found with Pan-STARRS, where ∼99.8% of the sample within the Pan-STARRS footprint is recovered, as compared to a low ∼20.8% in Gaia DR2. Using these results, we train a Gaussian process regressor to calibrate two photometric metallicity relationships. For dwarfs of 3500 < T{sub eff} < 5280 K, we use metallicity values of 4378 stars from the Apache Point Observatory Galactic Evolution Experiment and Hejazi et al. to calibrate the relationship, producing results with a 1σ precision of 0.12 dex and few systematic errors. We then indirectly infer the metallicity of 4018 stars with 2850 < T{sub eff} < 3500 K, which are wide companions of primaries whose metallicities are estimated with our first regressor, to produce a relationship with a 1σ precision of 0.21 dex and significant systematic errors. Additional work is needed to better remove unresolved binaries from this second sample to reduce these systematic errors.

47 OTHER INSTRUMENTATION↗

Improving and Assessing Planet Sensitivity of the GPI Exoplanet Survey with a Forward Model Matched Filter

We present a new matched-filter algorithm for direct detection of point sources in the immediate vicinity of bright stars. The stellar point-spread function (PSF) is first subtracted using a Karhunen-Loéve image processing (KLIP) algorithm with angular and spectral differential imaging (ADI and SDI). The KLIP-induced distortion of the astrophysical signal is included in the matched-filter template by computing a forward model of the PSF at every position in the image. To optimize the performance of the algorithm, we conduct extensive planet injection and recovery tests and tune the exoplanet spectra template and KLIP reduction aggressiveness to maximize the signal-to-noise ratio (S/N) of the recovered planets. We show that only two spectral templates are necessary to recover any young Jovian exoplanets with minimal S/N loss. We also developed a complete pipeline for the automated detection of point-source candidates, the calculation of receiver operating characteristics (ROC), contrast curves based on false positives, and completeness contours. We process in a uniform manner more than 330 data sets from the Gemini Planet Imager Exoplanet Survey and assess GPI typical sensitivity as a function of the star and the hypothetical companion spectral type. This work allows for the first time a comparison of different detection algorithms at a survey scale accounting for both planet completeness and false-positive rate. We show that the new forward model matched filter allows the detection of 50% fainter objects than a conventional cross-correlation technique with a Gaussian PSF template for the same false-positive rate.

79 ASTRONOMY AND ASTROPHYSICS↗