Development of a Linear Ion Trap Mass Spectrometer (LITMS) Investigation for Future Planetary Surface Missions

Future surface missions to Mars and other planetary bodies will benefit from continued advances in miniature sensor and sample handling technologies that enable high-performance chemical analyses of natural samples. Fine-scale (approx.1 mm and below) analyses of rock surfaces and interiors, such as exposed on a drill core, will permit (1) the detection of habitability markers including complex organics in association with their original depositional environment, and (2) the characterization of successive layers and gradients that can reveal the time-evolution of those environments. In particular, if broad-based and highly-sensitive mass spectrometry techniques could be brought to such scales, the resulting planetary science capability would be truly powerful. The Linear Ion Trap Mass Spectrometer (LITMS) investigation is designed to conduct fine-scale organic and inorganic analyses of short (approx.5-10 cm) rock cores such as could be acquired by a planetary lander or rover arm-based drill. LITMS combines both pyrolysis/gas chromatograph mass spectrometry (GCMS) of sub-sampled core fines, and laser desorption mass spectrometry (LDMS) of the intact core surface, using a common mass analyzer, enhanced from the design used in the Mars Organic Molecule Analyzer (MOMA) instrument on the 2018 ExoMars rover. LITMS additionally features developments based on the Sample Analysis at Mars (SAM) investigation on MSL and recent NASA-funded prototype efforts in laser mass spectrometry, pyrolysis, and precision subsampling. LITMS brings these combined capabilities to achieve its four measurement objectives: (1) Organics: Broad Survey Detect organic molecules over a wide range of molecular weight, volatility, electronegativity, concentration, and host mineralogy. (2) Organic: Molecular Structure Characterize internal molecular structure to identify individual compounds, and reveal functionalization and processing. (3) Inorganic Host Environment Assess the local chemical/mineralogical makeup of organic host phases to help determine deposition and preservation factors. (4) Chemical Stratigraphy Analyze the fine spatial distribution and variation of key species with depth.

Mars↗

Ogle-2012-blg-0724lb: A Saturn Mass Planet Around an M-dwarf

We report the discovery of a planet by the microlensing method, OGLE-2012-BLG-0724Lb. Although the duration of the planetary signal for this event was one of the shortest seen for a planetary event, the anomaly was well covered thanks to high-cadence observations taken by the survey groups OGLE and MOA. By analyzing the light curve, this planetary system is found to have a mass ratio q = (1.58 +/- 0.15) x 10(exp -3). By conducting a Bayesian analysis, we estimate that the host star is an M dwarf with a mass of M(sub L) = 0.29(+0.33/-0.16) solar mass located at D(sub L) = 6.7(+1.1/-1.2) kpc away from the Earth and the companion's mass is m(sub P) = 0.47(+0.54/-0.26) M(Jup). The projected planet- host separation is a falsum = 1.6(+0.4/-0.3) AU. Because the lens-source relative proper motion is relatively high, future highresolution images would detect the lens host star and determine the lens properties uniquely. This system is likely a Saturn-mass exoplanet around an M dwarf, and such systems are commonly detected by gravitational microlensing. This adds another example of a possible pileup of sub-Jupiters (0.2 less than m(sub P)/M(sub Jup) less than 1) in contrast to a lack of Jupiters (approximately 1-2 M(sub Jup)) around M dwarfs, supporting the prediction by core accretion models that Jupiter-mass or more massive planets are unlikely to form around M dwarfs.

microlensing↗

Life Support Goals Including High Closure and Low Mass Should Be Reconsidered Using Systems Analysis

Recycling space life support systems have been built and tested since the 1960s and have operated on the International Space Station (ISS) since the mid 2000s. The development of space life support has been guided by a general consensus focused on two important related goals, increasing system closure and reducing launch mass. High closure is achieved by recycling crew waste products such as carbon dioxide and condensed humidity. Recycling directly reduces the mass of oxygen and water for the crew that must be launched from Earth. The launch mass of life support can be further reduced by developing recycling systems with lower hardware mass and reduced power. The life support consensus has also favored using biological systems. The goal of increasing closure using biological systems suggests that food should be grown in space and that biological processors be used for air, water, and waste recycling. The goal of reducing launch mass led to use of Equivalent System Mass (ESM) in life support advocacy and technology selection. The recent consensus assumes that the recycling systems architecture developed in the 1960s and implemented on ISS will be used on all future long missions. NASA and other project organizations use the standard systems engineering process to guide hardware development. The systems process was used to develop ISS life support, but it has been less emphasized in planning future systems for the moon and Mars. Since such missions are far in the future, there has been less immediate need for systems engineering analysis to consider trade-offs, reliability, and Life Cycle Cost (LCC). Preliminary systems analysis suggests that the life support consensus concepts should be revised to reflect systems engineering requirements.

systems analysis↗

Would Current International Space Station (ISS) Recycling Life Support Systems Save Mass on a Mars Transit?

The oxygen and water are recycled on the International Space Station (ISS) to save the cost of launching their mass into orbit. Usually recycling systems are justified by showing that their launch mass would be much lower than the mass of the oxygen or water they produce. Short missions such as Apollo or space shuttle directly provide stored oxygen and water, since the needed total mass of oxygen and water is much less than that of there cycling equipment. Ten year or longer missions such as the ISS or a future moon base easily save mass by recycling while short missions of days or weeks do not. Mars transit and long Mars surface missions have an intermediate duration, typically one to one and a half years. Some of the current ISS recycling systems would save mass if used on a Mars transit but others would not.

mass↗

Recent Advancements in Electrical Capacitance Mass Gauging for Cryogenic PropellantTanks

The current lack of unsettled mass gauging is a key roadblock for many space activities, such as orbital refueling, missions to the Moon and Mars, and nuclear thermal and nuclear electric propulsion technologies. Liquid can form any one of an infinite number of configurations in microgravity, such as floating in globs or accumulating on tank surfaces in discontiguous volumes, or both. Capacitive sensing requires no moving parts and dissipates close to zero heat, making it an ideal candidate for cryogenic fluid mass gauging in settled and unsettled configurations. Capacitive sensing has a history of proven use in space propellant tanks, including tanks on the space shuttle, Saturn V, and the Apollo Lunar Excursion Module. Modern capacitive sensor technology allows using the entire tank as the capacitor volume by placing electrodes on the tank walls and propellant management surfaces. Capacitance is directly related to density, and therefore to mass for fixed volumes. In this presentation, we discuss the concepts behind whole-tank capacitance mass gauging and associated engineering challenges. We describe recent efforts to develop a micro-g unsettled cryogenic mass gauge using whole-tank capacitance sensing, including the development of test beds, electronics, and algorithms. We describe several mathematical processing techniques, including empirical-based averaging, electrical capacitance volume tomography, and spatial regularization. A modeling study, performed using settled configurations in gravity and no gravity, and with a set of 100 random fluid configurations, has indicated that spatial regularization, in which capacitance measurements are weighted to account for non-uniform electric fields, yields a mass fraction accuracy of 8% for any fluid configuration. Such a sensor is expected to operate in real time with a sampling frequency of at least 1 kHz.

cryogenic↗

Mass, momentum and energy flow from an MPD accelerator

The mass, momentum, and energy flows are measured over a current range of 8 to 50 kA and inlet mass flows of 2 to 36q/sec of argon. The momentum flux profile indicates that the accelerator produces a uniform, 2-inch diameter axial jet at the anode which expands into a Gaussian profile at an axial station 11 inches from the anode. The electromagnetic component of the thrust is found to follow the familiar quadratic dependence on arc current, while a more complex empirical relation is needed to correlate the gasdynamic contribution with the current and mass flow rate. Using available time-of-flight velocity profiles at a current of 16 kA and a mass flow of 5.9 g/sec, calculated flux profiles of mass and kinetic energy exhibit a tendency for some fraction of the inlet mass flow to leak out at a low velocity around the central high velocity core.

Cory, J. S.↗

Optimal detumbling of a large manned spacecraft using an internal moving mass

The use of a movable mass control system to stabilize an arbitrarily tumbling asymmetric vehicle about the maximum inertia axis is considered. A first-order gradient optimization technique is used to minimize angular velocity components along the intermediate and minimum inertia axes. This method permits a wide range of initial guesses for mass position history. Motion of the control mass is along a linear track fixed in the vehicle. The control variable is taken as mass acceleration with respect to body coordinates. Motion is limited to defined quantities and a penalty function is used to insure a given range of positions. Numerical solutions of the optimization equations verify that minimum time detumbling is achieved with the largest permissible movable mass, length of linear track, and positions of the mass on the two coordinates perpendicular to the linear motion.

Kunciw, B. G.↗

On the mass-luminosity relation.

The results of a least-squares study of the mass-luminosity relation for eclipsing and visual binary stars consisting of main sequence components are presented. Two methods are discussed. First, the values of the coefficients A and B in the relation log M = A + BM sub BOL are determined. Then a technique which permits the determination of alpha and beta in the relation M = alpha L beta, when only the sum of the masses, and not the individual masses of each component, is known. The results and a comparison of the two methods are discussed. It is found that the following mass-luminosity relation represents the observational data satisfactorily: log M = 0.504 - 0.103 M sub BOL, -8 less than or equal to M sub BOL less than or equal to +10.5. A discussion of the data and of the possibility that separate mass-luminosity relations may exist for visual and eclipsing binaries is given. The possibility that more than one mass-luminosity relation is required in the range -8 less than or equal to M sub BOL less than or equal to +13 is also discussed.

Mccluskey, G. E., Jr.↗

The local mass density

An improved mass-luminosity relation for faint main-sequence stars derived from recently revised masses for some faint double stars is presented. The total local mass density is increased to nearly 0.2 solar masses per cu pc. This estimate is as large as the mass density required by Oort's (1965) dynamical analysis of stellar motions perpendicular to the galactic plane if the mass is concentrated in a narrow layer.

Veeder, G. J.↗

Influence of rotation on the maximum mass of pulsationally stable stars

The critical mass for stability against radial pulsations in rotating, homogeneous main-sequence stars is found to be greater than in the case of no rotation. Analytic and detailed numerical models show that the critical mass rises steeply with increasing concentration of angular momentum to the center of the star. For uniform rotation near breakup velocity at the star's equator the critical mass is about 850 solar masses if an electron-scattering opacity is used, or about 5000 solar masses if the opacities of Cox and Stewart are used. For nonuniform rotation with a constant ratio of centrifugal force to gravity in the star, the critical mass becomes 'infinite' long before breakup velocity is attained. The relevance of the present results to several observational problems is noted.

Stothers, R.↗

Optimal detumbling of a large manned spacecraft using an internal moving mass

This investigation deals with the use of a movable mass control system to stabilize a tumbling asymmetric spacecraft about the maximum inertia axis. A first-order gradient optimization technique is used to minimize angular velocity components along the intermediate and minimum inertia axes, thus, permitting a wide range of initial guesses for mass position history. Motion of the control mass is along a linear track fixed in the vehicle. The control variable is taken as mass acceleration with respect to body coordinates. Motion is limited to defined quantities and a penalty function is used to insure a given range of positions. Numerical solutions of the optimization equations verify that minimum time detumbling is achieved with the largest permissible movable mass, length of linear track, and positions of the mass on the two coordinates perpendicular to the linear motion. The optimal method permits detumbling in about one-fourth the time when compared to a force control law formulation available in the literature.

Kunciw, B. G.↗

Theoretical monochromatic-wave-induced currents in intermediate water with viscosity and nonzero mass transport

Wave-induced mass-transport current theories with both zero and nonzero net mass (or volume) transport of the water column are reviewed. A relationship based on the Longuet-Higgens theory is derived for wave-induced, nonzero mass-transport currents in intermediate water depths for a viscous fluid. The relationship is in a form useful for experimental applications; therefore, some design criteria for experimental wave-tank tests are also presented. Sample parametric cases for typical wave-tank conditions and a typical ocean swell were assessed by using the relation in conjunction with an equation developed by Unluata and Mei for the maximum wave-induced volume transport. Calculations indicate that substantial changes in the wave-induced mass-transport current profiles may exist dependent upon the assumed net volume transport. A maximum volume transport, corresponding to an infinite channel or idealized ocean condition, produces the largest wave-induced mass-transport currents. These calculations suggest that wave-induced mass-transport currents may have considerable effects on pollution and suspended-sediments transport as well as buoy drift, the surface and midlayer water-column currents caused by waves increasing with increasing net volume transports. Some of these effects are discussed.

Talay, T. A.↗

Survey and Experimental Testing of Nongravimetric Mass Measurement Devices

Documentation presented describes the design, testing, and evaluation of an accelerated gravimetric balance, a low mass air bearing oscillator of the spring-mass type, and a centrifugal device for liquid mass measurement. A direct mass readout method was developed to replace the oscillation period readout method which required manual calculations to determine mass. A protoype 25 gram capacity micro mass measurement device was developed and tested.

Oakey, W. E.↗

Planetary atmospheres with mass spectrometers carried on high-speed probes or satellites

Earth satellite-borne mass spectrometers are considered, taking into account the identification of atomic oxygen in the thermosphere with an 'open' source mass spectrometer flown on a sounding rocket, the conventional closed-source instrument, the mass spectrometers on the Atmosphere Explorer satellites, and mass spectrometer electron multiplier output. A description is presented of mass spectrometers and planetary entry probes. Attention is given to an attempt to obtain an atmospheric composition profile with a terrestrial entry probe, the descending trajectory in the early orbits of the Atmosphere Explorer C satellite, and the molecular nitrogen densities for the descending legs of the orbits. It is pointed out that chemical reactions on the surfaces of the mass spectrometer make the measurement of reactive atmospheric species such as atomic oxygen very difficult.

Nier, A. O.↗

Mass loss and OH maser emission from Mira variables

The mass, radius, and luminosity of 26 Mira variables that are known OH sources of radio emission at 1612 MHz have been estimated. The time-independent solution of Salpeter's (1974) stellar-wind equation and a period-density relation are used to solve for basic stellar parameters, with the aid of the terminal expansion velocity of the OH maser cloud. Masses obtained from these calculations are consistent with other estimated values for masses of Mira variables. Good agreement is obtained when comparing the rate of mass loss as determined from Reimers's (1977) semiempirical relation with estimates of the mass-loss rate as deduced from theoretical models involving radiation pressure on grains. These calculations suggest a strong correlation between the mass-loss rate and the pulsation period. Arguments concerning the general properties of silicate grains from radiation-pressure-driven stellar-wind equations are discussed.

Michalitsianos, A. G.↗

Convective penetrations and observable consequences of helium shell flashes in 3 and 6 solar-mass red supergiants

The results of 61 detailed numerical flash calculations are examined, with particular reference to 3 and 6 solar-mass stars with core masses ranging from 0.56 to 0.60 the solar mass and 0.94 to 0.95 the solar mass, respectively. First penetration of the convective envelope into pockets of carbon in the intershell region was found for the 15th flash for the 6 solar-mass case, with continuing deeper penetration for the flashes thereafter. However, no such type of envelope penetration could be found for the 3 solar-mass case.

Sackmann, I.-J.↗

Pioneer Venus Sounder Probe Neutral Gas Mass Spectrometer

A neutral gas mass spectrometer was flown to Venus as part of the Pioneer Venus Multiprobe to measure the composition of its lower atmosphere. The instrument, mounted in the Sounder Probe, was activated after the probe entered the top of the atmosphere, and it obtained data during the descent from 62 km to the surface. Atmospheric gases were sampled through a pair of microleaks, the effluent from which was pumped by a combination of ion and getter pumping. A pneumatically operated valve, controlled by the ambient atmospheric pressure, maintained the ion source pressure at a nearly constant value during descent while the atmospheric pressure varied by three orders of magnitude. A single focusing magnetic sector field mass spectrometer with mass resolution sufficient to reasonably separate argon from C3H4 at 40 amu provided the mass analysis and relative abundance measurements. A microprocessor controlled the operation of the mass spectrometer through a highly efficient peak-tip stepping routine and data compression algorithm that effected a scan of the mass spectrum from 1 to 208 amu in 64 sec while requiring an information rate of only 40 bits/sec to return the data to earth. A subscale height altitude resolution was thus obtained. Weight, size, and power requirements were minimized to be consistent with interplanetary flight contraints.

Hoffman, J. H.↗

Application of ion-induced nucleation mass spectrometry in the analysis of trace gases evolved from a polyimide film during the thermal curing stages

Trace gases evolved from a polyimide film during its thermal curing stages have been studied using ion-induced nucleation mass spectrometry. The technique involved exposing the test gas sample to a low energy beta source and recording the masses of the ion-induced molecular clusters formed in the reaction chamber. On the basis of the experimentally observed molecular cluster spectra, it has been concluded that the dominant trace component had a molecular weight of 87 atomic mass units. This component has been identified as a molecule of dimethylacetamide (DMAC) which had been used as a solvent in the preparation of the test polyimide specimen. This identification has been further confirmed by comparing the spectra of the test gas sample and the DMAC calibration sample obtained with a conventional mass spectrometer. The advantages of the ion-induced nucleation mass spectrometer versus the conventional mass spectrometer are discussed.