Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “long term testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Gas Hydrate Saturation Estimation Form Acoustic Log Data in the 2018 Alaska North Slope Hydrate-01 Stratigraphic Test

Completed in December 2018, the Alaska North Slope Hydrate 01 stratigraphic test well provides a wealth of logging-while-drilling (LWD) data for strata to below the base of gas hydrate stability (BGHS). This well is intended to be the first of three wells drilled for a comprehensive long-term gas hydrate production test conducted by the National Energy Technology Laboratory, the Japan Oil, Gas and Metals National Corporation, and the U.S. Geological Survey (USGS). The Hydrate 01 stratigraphic test well confirmed the presence of gas hydrate in two sand reservoirs within the hydrate stability zone, indicating the suitability of this location for a long-term gas hydrate production test.<p>The USGS, using an effective-medium-theory rock-physics approach, has estimated gas hydrate saturations from compressional (P) and shear (S) wave log data acquired in the Hydrate 01 well. We assume that gas hydrate occurs as pore-filling load-bearing material (i.e., part of the grain matrix). For Unit D, approximately 500 feet above the BGHS, both P-wave and S-wave acoustic logs indicate moderate gas hydrate saturations with S-wave results slightly lower than those for P-waves. For the Unit B, located just above the BGHS, we obtain moderate to high gas hydrate saturation estimates from both sonic logs. Our P-wave saturation estimates agree well with results from electrical-resistivity-based estimates, whereas estimates from nuclear magnetic resonance LWD data generally suggest 5 to 10 percent higher saturations; our S-wave results suggest lower saturations. These differences likely indicate complexities in the form of gas hydrate occurrence within the sediment pore space, potentially including differences between hydrate occurrence in Units D and B.</p>

Haines, Seth↗

Initial development of an in-situ, passive material surveillance test article for monitoring high temperature reactor structural components

This report describes the development of a family of passively-actuated surveillance test articles, suitable for use in an in-situ reactor test program monitoring the degradation in structural material properties caused by the reactor environment. The test articles apply creep-fatigue-type cyclic load to a test section driven by changes in the reactor coolant temperature converted to mechanical force by differential thermal expansion. The report describes three types of test articles, all of which apply the load to a 316H test section using Alloy 617 as the driver material. The three types of specimens each serve a unique purpose: (1) initial proof-of-concept, (2) validation of the models used to size the specimens to achieve a given strain range, and (3) demonstration that the articles can be miniaturized for use in an actual operating reactor. In addition to the specimen design, fabrication, and testing, this report describes the outline of two types of in-situ monitoring programs, using the test article. Monitoring programs such as these could be a critical component in gaining regulator acceptance for Molten Salt Reactor (MSR) designs using structural materials for which there is little long-term experimental environmental testing or operating experience available for calibrating the component structural design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ground Testing of an Oxygen Concentrator in a Simulated International Space Station (ISS) Cabin Environment

The method for supplying medical oxygen to respiratorily-compromised astronauts on the International Space Station (ISS) and in future Orion missions consists of drawing oxygen from high pressure oxygen tanks. An Oxygen Concentrator Module (OCM) is a device that pulls in ambient air and separates out the nitrogen, resulting in a high concentration oxygen source. This technology has the potential to eliminate resupply and oxygen-enrichment issues associated with using high pressure oxygen tanks and become an alternative technology to support medical oxygen operations for future exploration missions. In this study, we test the long-term performance of a Commercial Off-the-Shelf (COTS) OCM in a simulated ISS cabin environment. Humidified air, carbon dioxide, and fifteen representative trace contaminants are continuously injected through a enclosed test chamber where the OCM is challenged. This study included the first successful demonstration of the Trace Gas Injection System (TGIS), which reliably and continuously produced ISS levels of trace contaminants, carbon dioxide, and humidity in an enclosed environment. The TGIS is a new and unique ground capability with significant implications for Test Readiness Level (TRL) advancement of COTS items and Government Furnished Equipment (GFE). This study demonstrated that the tested OCM reliably delivers enriched oxygen mostly at desired performance specifications. This study also demonstrated that the OCM does not inadvertently concentrate trace gases in its oxygen product stream, as detectable concentrations of trace contaminants in the oxygen product stream were at all times below the simulated ISS levels.

medical oxygen↗

Ground Testing of an Oxygen Concentrator in a Simulated International Space Station (ISS) Cabin Environment

The method for supplying medical oxygen to respiratorily-compromised astronauts on the International Space Station (ISS) and in future Orion missions consists of drawing oxygen from high pressure oxygen tanks. An Oxygen Concentrator Module (OCM) is a device that pulls in ambient air and separates out the nitrogen, resulting in a high concentration oxygen source. This technology has the potential to eliminate resupply and oxygen-enrichment issues associated with using high pressure oxygen tanks and become an alternative technology to support medical oxygen operations for future exploration missions. In this study, we test the long-term performance of a Commercial Off-the-Shelf (COTS) OCM in a simulated ISS cabin environment. Humidified air, carbon dioxide, and fifteen representative trace contaminants are continuously injected through an enclosed test chamber where the OCM is challenged. This study included the first successful demonstration of the Trace Gas Injection System (TGIS), which reliably and continuously produced ISS levels of trace contaminants, carbon dioxide, and humidity in an enclosed environment. The TGIS is a new and unique ground capability with significant implications for Test Readiness Level (TRL) advancement of COTS items and Government Furnished Equipment (GFE). This study demonstrated that the tested OCM reliably delivers enriched oxygen mostly at desired performance specifications. This study also demonstrated that the OCM does not inadvertently concentrate trace gases in its oxygen product stream, as detectable concentrations of trace contaminants in the oxygen product stream were at all times below the simulated ISS levels.

medical oxygen↗

Flight simulation testing of advanced composites for supersonic cruise aircraft applications

The goal of this program is to characterize advanced composite systems before and after exposures to simulated supersonic cruise environments for real times of up to 50,000 hours. Fatigue data for specimens tested at various temperatures and stress ratios are presented. The changes in properties and the degradation mechanisms during high temperature aging are discussed and illustrated using metallographic and fractographic techniques. Initial results of long term flight simulation tests are presented and compared with wearout model predictions based on accelerated flight simulation exposures.

Haskins, J. F.↗

NASA GRC Stirling Technology Development Overview

The Department of Energy, Lockheed Martin (LM), Stirling Technology Company, and NASA Glenn Research Center (GRC) are developing a high-efficiency Stirling Radioisotope Generator (SRG) for potential NASA Space Science missions. The SRG is being developed for multimission use, including providing spacecraft onboard electric power for NASA deep space missions and power for unmanned Mars rovers. NASA GRC is conducting an in- house supporting technology project to assist in developing the Stirling convertor for space qualification and mission implementation. Preparations are underway for a thermalhacuum system demonstration and unattended operation during endurance testing of the 55-We Technology Demonstration Convertors. Heater head life assessment efforts continue, including verification of the heater head brazing and heat treatment schedules and evaluation of any potential regenerator oxidation. Long-term magnet aging tests are continuing to characterize any possible aging in the strength or demagnetization resistance of the permanent magnets used in the linear alternator. Testing of the magnet/lamination epoxy bond for performance and lifetime characteristics is now underway. These efforts are expected to provide key inputs as the system integrator, LM, begins system development of the SRG. GRC is also developing advanced technology for Stirling convertors. Cleveland State University (CSU) is progressing toward a multi-dimensional Stirling computational fluid dynamics code, capable of modeling complete convertors. Validation efforts at both CSU and the University of Minnesota are complementing the code development. New efforts have been started this year on a lightweight convertor, advanced controllers, high-temperature materials, and an end-to-end system dynamics model. Performance and mass improvement goals have been established for second- and third-generation Stirling radioisotope power systems.

Thieme, Lanny G.↗

Unraveling interphase-driven failure pathways in LiMn0.6Fe0.4PO4/graphite pouch cells

LiMnxFe1−xPO4 (LMFP) is a promising high-voltage, thermally stable, and earth-abundant cathode material, yet its practical application is limited by interphase instability and Mn dissolution. In this work, we systematically evaluate LiMn0.6Fe0.4PO4/graphite pouch cells using three electrolyte formulations including control carbonate electrolyte, control + 2 wt% vinylene carbonate (VC), and control + 2 wt% VC + 1 wt% 1,3,2-dioxathiolane 2,2-dioxide (DTD), to establish how electrolyte composition governs interphase chemistry and long-term degradation. Electrochemical testing shows that both additives are preferentially reduced prior to ethylene carbonate (EC) during cell formation, generating robust cathode-electrolyte interphase (CEI) and solid-electrolyte interphase (SEI) layers that suppress gas evolution and raise the first-cycle coulombic efficiency to 89.3%. Additionally, the dual-additive electrolyte delivers the most stable performance, retaining over 85% capacity after 600 cycles while minimizing impedance growth under long-term cycling at C/3 and 40 °C. Soft X-ray absorption spectroscopy confirms that VC + DTD effectively suppresses electrolyte oxidation at the cathode surface, and micro-X-ray fluorescence shows substantially reduced Mn dissolution and deposition on the graphite anode. Density functional theory simulations further provided insights into the structural and energetic influences of alkoxide species on the cathode surface, proposing a Mn2+ extraction mechanism. The combined experimental and computational findings establish a mechanistic link between electrolyte composition and interphase evolution, highlighting the effectiveness of electrolyte engineering for extending the operational lifetime of LMFP-based lithium-ion batteries.

Chak, Chanmonirath Michael↗

An Update of the Nation's Long-Term Strategic Needs for NASA's Aeronautics Test Facilities

The National Aeronautics and Space Administration's (NASA's) major wind tunnel (WT), propulsion test (PT), and simulation facilities exist to serve NASA's and the nation's aeronautics needs. RAND Corporation researchers conducted a prior study of these facilities from 2002 to 2003, identifying (1) NASA's continuing ability to serve national needs, (2) which facilities appear strategically important from an engineering perspective given the vehicle classes the nation investigates and produces, and (3) management challenges and issues. This documented briefing (DB) is the final report from a new, one-year study (conducted from September 2006 through January 2008), partially updating the prior assessment. The study focuses on updating the list of facilities in the prior study that were deemed to be strategically important (again, from an engineering perspective) in serving those needs. This update also adds a new assessment of national needs for six major aeronautics simulators at NASA and lists those deemed strategically important.

NASA FACILITIES↗

Environmental Exposure Effects on Composite Materials for Commercial Aircraft

This period's activities were highlighted by continued long term and accelerated lab exposure testing, and by completion of all fabrication tasks on the optional material systems, AS1/3501-6 and Kevlar 49/F161-188. Initial baseline testing was performed on the two optional material systems. Long term exposure specimens were returned from three of the four ground rack sites and from two of the three aircraft locations. Test data from specimens returned from Dryden after 2 years exposure do not indicate continuing trends of strength reduction from the 1 year data. Test data from specimens returned from the Wellington, new Zealand ground rack and on Air New Zealand aircraft after 1 year exposure show strength changes fairly typical of other locations.

Hoffman, D. J.↗

Lithium-Ion Verification Test Program

In order to assess the capabilities of current aerospace lithium-ion cells to perform long-term NASA missions, low-earth-orbits (LEO) testing to evaluate long-term cycle life was initiated. A flexible program was developed at NASA Glenn Research Center to enable assessment of technology developments as they occur as well as provide information about different cell vendors and cell designs. Following extensive characterization testing, cells are tested using LEO charge and discharge profiles under ten different combinations of test conditions that were statistically chosen to determine the effects of depth-of-discharge, temperature, and end-of-charge voltage on LEO cycle life. Four cells from each vendor are tested at each specific combination of conditions. Conditions included in the test matrix are depth-of-discharges of 20%, 30, 35%, and 40%; temperatures of 20, 30, and 40 C; and end-of-charge voltages of 3.85 V, 3.95 V, and 4.05 V. Cells are randomly assigned to packs and packs are randomly assigned to test conditions. The capacity of the cells to 3.0 V at the conditions of the test is being periodically measured. The results of this testing will be used to model cell performance and degradation as a function of test operating conditions. Cells are being evaluated in 4-cell series strings with charge voltage limits being applied to individual cells by charge control units designed and built at NASA Glenn Research Center. Testing is being performed at the Naval Surface Warfare Center/Crane Division in Crane, IN. Testing was initiated in September 2004 with 40 Ah cells from Saft and 30 Ah cells from Lithion. The test program is being expanded with the addition of cells from MSA and the addition of small cell modules is being considered. Preliminary results showing voltage, temperature, usable capacity per unit mass, and voltage dispersion as their changes over time for the cells at 20 C is presented.

McKissock, Barbara↗

Data Acquisition System Selection and Calibration of Resistive Moisture Content Measurements for Large-Scale Field Studies in Cold Climate Residential Building Envelope Performance

The residential building stock built before the energy codes were enforced has several significant inefficiency problems in terms of insulation and air leakage. To decrease these inefficiencies, building retrofits are necessary. However, if the envelope is not appropriately designed, excessive accumulation of moisture content and thus mold formation and decay inside the envelope layers can be a vital problem. This risk becomes higher, especially in extreme climate conditions such as cold winters and hot and humid summers as in some northern regions of the U.S. Field studies are essential to test the long-term hygrothermal performance of building envelopes. Although in-situ temperature, RH, and heat flux measurements are straightforward, moisture content measurements are cumbersome. Mainly, because of the heterogeneous nature of the wood materials, deviations and nonuniformities within the materials are unavoidable. Resistance measurements are one of the oldest methods used to measure the moisture content of wood and other building materials. In large-scale studies, it is commonly preferred to use multi-purpose data acquisition systems (DAQ) and custom-made or prefabricated moisture pins to measure the electrical resistance (and thus moisture content) of critical building materials. These multi-purpose DAQ systems generally provide lower costs and offer more flexibility. However, these systems require calibration and fine-tuning to achieve accurate moisture content measurements. A large-scale, two-year-long field study was conducted in northern Minnesota to monitor the hygrothermal performance of residential retrofit wall systems in cold climates. Two base case walls and sixteen different wall treatments were tested. Moisture contents were measured at various layers in each wall treatment using 85 sets of moisture pins. This paper focuses on the overall approach, fabrication, and calibration methodology for the combination of custom-made moisture pins and a multi-purpose DAQ. The aim is to directly use the low-excitation multi-purpose DAQ without any extra voltage regulator. A half-bridge circuit is used to measure wood resistance with 4V excitation voltage and 100 kΩ and 500 kΩ reference resistors. The system is calibrated for four different materials: Douglas fir, lodgepole pine, western red cedar, and oriented strand board (OSB). Calibration experiments were done under controlled conditions in 50% and 65% RH test chambers. Resistance-based moisture content calibration curves are obtained for each species. Results show that higher reference resistors provided better calibration curves for lower excitation voltages.

Desjarlais, Andre Omer↗

Creep rupture behavior of unidirectional advanced composites

A 'material modeling' methodology for predicting the creep rupture behavior of unidirectional advanced composites is proposed. In this approach the parameters (obtained from short-term tests) required to make the predictions are the three principal creep compliance master curves and their corresponding quasi-static strengths tested at room temperature (22 C). Using these parameters in conjunction with a failure criterion, creep rupture envelopes can be generated for any combination of in-plane loading conditions and ambient temperature. The analysis was validated experimentally for one composite system, the T300/934 graphite-epoxy system. This was done by performing short-term creep tests (to generate the principal creep compliance master curves with the time-temperature superposition principle) and relatively long-term creep rupture tensile tests of off-axis specimens at 180 C. Good to reasonable agreement between experimental and analytical results is observed.

Yeow, Y. T.↗

Understanding Chemo-Mechanical Stability of Protonic Ceramic Cells Through Electronic Conduction in the BaCe 0.7 Zr 0.1 Y 0.1 Yb 0.1 O 3-δ Electrolyte

BaCe 0.7 Zr 0.1 Y 0.1 Yb 0.1 O 3-δ (BCZYYb) is a promising ceramic electrolyte for reversible protonic ceramic cells. It is reported that BCZYYb-based cells show excellent long-term durability, particularly in the electrolysis mode, in contrast to the cells based on the conventional electrolyte yttria-stabilized zirconia. In this study, we investigate the chemo-mechanical stability behavior (a low tendency of delamination) of the BCZYYb-based protonic ceramic cells in terms of local electronic conduction in the electrolyte. The local electronic conductivity of the BCZYYb electrolyte is determined using Pt-probe-embedded cells near each electrode interface. The BCZYYb electrolyte exhibits sufficient p-type conductivity (∼10 −3 S cm −1 ) near the oxygen electrode (corresponding p O 2 : 5.27–21 × 10 −2 atm) and n-type conductivity (∼10 −4 S cm −1 ) near the hydrogen electrode (corresponding p O 2 : 0.99–1.30 × 10 −24 atm) at 600 °C. A standard cell is prepared and tested over long-term in the fuel cell (at positive and negative voltages) and electrolysis modes. The cell exhibits stable performance without delamination or cracks in both operating modes, owing to local electronic conduction.

Electrochemistry↗

Development of Advanced Hydrocarbon Fuels at Marshall Space Flight Center

This was a small-scale, hot-fire test series to make initial measurements of performance differences of five new liquid fuels relative to rocket propellant-1 (RP-1). The program was part of a high-energy-density materials development at Marshall Space Flight Center (MSFC), and the fuels tested were quadricyclane, 1-7 octodiyne, AFRL-1, biclopropylidene, and competitive impulse noncarcinogenic hypergol (CINCH) (di-methyl-aminoethyl-azide). All tests were conducted at MSFC. The first four fuels were provided by the U.S. Air Force Research Laboratory (AFRL), Edwards Air Force Base, CA. The U.S. Army, Redstone Arsenal, Huntsville, AL, provided the CINCH. The data recorded in all hot-fire tests were used to calculate specific impulse and characteristic exhaust velocity for each fuel, then compared to RP-1 at the same conditions. This was not an exhaustive study, comparing each fuel to RP-1 at an array of mixture ratios, nor did it include important fuel parameters, such as fuel handling or long-term storage. The test hardware was designed for liquid oxygen (lox)/RP-1, then modified for gaseous oxygen/RP-1 to avoid two-phase lox at very small flow rates. All fuels were tested using the same thruster/injector combination designed for RP-1. The results of this test will be used to determine which fuels will be tested in future test programs.

Bai, S. D.↗

Control Design Strategies to Enhance Long-Term Aircraft Structural Integrity

Over the operational lifetime of both military and civil aircraft, structural components are exposed to hundreds of thousands of low-stress repetitive load cycles and less frequent but higher-stress transient loads originating from maneuvering flight and atmospheric gusts. Micro-material imperfections in the structure, such as cracks and debonded laminates, expand and grow in this environment, reducing the structural integrity and shortening the life of the airframe. Extreme costs associated with refurbishment of critical load-bearing structural components in a large fleet, or altogether reinventoring the fleet with newer models, indicate alternative solutions for life extension of the airframe structure are highly desirable. Increased levels of operational safety and reliability are also important factors influencing the desirability of such solutions. One area having significant potential for impacting crack growth/fatigue damage reduction and structural life extension is flight control. To modify the airframe response dynamics arising from command inputs and gust disturbances, feedback loops are routinely applied to vehicles. A dexterous flight control system architecture senses key vehicle motions and generates critical forces/moments at multiple points distributed throughout the airframe to elicit the desired motion characteristics. In principle, these same control loops can be utilized to influence the level of exposure to harmful loads during flight on structural components. Project objectives are to investigate and/or assess the leverage control has on reducing fatigue damage and enhancing long-term structural integrity, without degrading attitude control and trajectory guidance performance levels. In particular, efforts have focused on the effects inner loop control parameters and architectures have on fatigue damage rate. To complete this research, an actively controlled flexible aircraft model and a new state space modeling procedure for crack growth have been utilized. Analysis of the analytical state space model for crack growth revealed the critical mathematical factors, and hence the physical mechanism they represent, that influenced high rates of airframe crack growth. The crack model was then exercised with simple load inputs to uncover and expose key crack growth behavior. To characterize crack growth behavior, both "short-term" laboratory specimen test type inputs and "long-term" operational flight type inputs were considered. Harmonic loading with a single overload revealed typical exponential crack growth behavior until the overload application, after which time the crack growth was retarded for a period of time depending on the overload strength. An optimum overload strength was identified which leads to maximum retardation of crack growth. Harmonic loading with a repeated overload of varying strength and frequency again revealed an optimum overload trait for maximizing growth retardation. The optimum overload strength ratio lies near the range of 2 to 3 with dependency on frequency. Experimental data was found to correlate well with the analytical predictions.

Newman, Brett A.↗

Accelerated viscoelastic characterization of T300-5208 graphite-epoxy laminates

A viscoelastic response scheme for the accelerated characterization of polymer-based composite laminates in applied to T300/5208 graphite/epoxy. The response of uni-directional specimens is modeled. The transient component of the viscoelastic creep compliance is assumed to follow a power law approximation. A recursive relationship is developed, based upon the Schapery single-integral equation, which allows approximation of a continuous time-varying uniaxial load using discrete steps in stress. The viscoelastic response of T300/5208 to transverse normal and shear stresses is determined unsing 90 deg and 10 deg off-axis tensile specimens. In each case the seven viscoelastic material parameters required in the analysis are determined experimentally using short-term creep and creep recovery tests. It is shown that an accurate measure of the power law exponent is crucial for accurate long-term prediction. A short term test cycle selection procedure is proposed, which should provide useful guidelines for the evaluation of other viscoelastic materials.

Tuttle, M. E.↗

Soil organic carbon accrual due to more efficient microbial utilization of plant inputs at greater long-term soil moisture

High long-term soil moisture may either stimulate or inhibit soil organic carbon (SOC) losses through changes to mineral and chemical composition, and resultant organo-mineral interactions. Yet, the trade-off between mineralization and accrual of SOC under long-term variation in unsaturated soil moisture remains uncertain. We tested the underexplored relationships between long-term soil moisture and organo-mineral chemical composition and its implications for SOC persistence in an experimental field in New York, USA, with differences in long-term mean soil volumetric water content (0–0.15 m depth) ranging from 0.40 to 0.63 (v/v) during the growing season. Long-term soil moisture across 20 subplots on four fallow plots were positively correlated with SOC (R 2 = 0.23; P = 0.019, n = 20), mineral-associated organic matter (MAOM) content (g fraction/g soil) (R 2 = 0.44; P = 0.001; n = 20) and occluded particulate organic matter (oPOM) content (R 2 = 0.18; P = 0.033; n = 20). Higher long-term soil moisture was associated with a decrease in the relative content of sodium pyrophosphate extractable Fe (R 2 = 0.33; P < 0.005; n = 20), an increase in sodium dithionite extractable Fe (R 2 = 0.44; P < 0.001; n = 20), and an increase in SOC retention by non-crystalline Al pools (R 2 = 0.51; P = 0.0002 for sodium pyrophosphate extracts, R 2 = 0.41; P = 0.0014 for hydroxylamine hydrochloride extracts; n = 20 for both). Increasing long-term soil moisture was associated with a four-fold increase in microbial biomass C (per unit SOC) and lower metabolic quotient (R 2 = 0.56, P < 0.001). MAOM fractions of high-moisture soils had lower C:N (from C:N 9.5 to 9.0, R 2 = 0.27, P = 0.011, n = 20). Consistent with decreasing C:N, increasing decomposition with increasing moisture was reflected by a 15% and 10% greater proportion of oxidized carboxylic-C to aromatic-C and O-alkyl C, respectively, as measured with 13 C NMR, and a more pronounced FTIR signature of N-containing proteinaceous compounds in high-moisture MAOM fractions, indicative of microbial metabolites and transformation products. A partial least squares regression showed that SOC content increased with greater long-term moisture (P = 0.019), pyrophosphate-extractable Al (P = 0.0001), and exchangeable Ca (P = 0.013). Here our results show that higher long-term soil moisture resulted in SOC accrual by enhancing conversion of plant inputs into microbial biomass that interacts with reactive minerals.

58 GEOSCIENCES↗