Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Artificial neural network application for space station power system fault diagnosis

This study presents a methodology for fault diagnosis using a Two-Stage Artificial Neural Network Clustering Algorithm. Previously, SPICE models of a 5-bus DC power distribution system with assumed constant output power during contingencies from the DDCU were used to evaluate the ANN's fault diagnosis capabilities. This on-going study uses EMTP models of the components (distribution lines, SPDU, TPDU, loads) and power sources (DDCU) of Space Station Alpha's electrical Power Distribution System as a basis for the ANN fault diagnostic tool. The results from the two studies are contrasted. In the event of a major fault, ground controllers need the ability to identify the type of fault, isolate the fault to the orbital replaceable unit level and provide the necessary information for the power management expert system to optimally determine a degraded-mode load schedule. To accomplish these goals, the electrical power distribution system's architecture can be subdivided into three major classes: DC-DC converter to loads, DC Switching Unit (DCSU) to Main bus Switching Unit (MBSU), and Power Sources to DCSU. Each class which has its own electrical characteristics and operations, requires a unique fault analysis philosophy. This study identifies these philosophies as Riddles 1, 2 and 3 respectively. The results of the on-going study addresses Riddle-1. It is concluded in this study that the combination of the EMTP models of the DDCU, distribution cables and electrical loads yields a more accurate model of the behavior and in addition yielded more accurate fault diagnosis using ANN versus the results obtained with the SPICE models.

Momoh, James A.↗

NASA Lunar Surface Operations & Power Grid

The National Aeronautics and Space Administration (NASA) Artemis Program is developing, testing, and demonstrating new capabilities and technologies required to support a sustainable human presence on the lunar surface and a longer-term vision of sending astronauts to Mars. Artemis lunar surface operations will begin with robotically exploring the lunar south polar regions for locations suitable for harvesting lunar surface resources. Over time activities on the lunar surface will expand beyond robotic operations to human lunar surface operations with the delivery of a lunar habitat and in-situ resource utilization (ISRU) assets increasing the need for highly reliable and available electrical power. As operations move beyond the Artemis technology demonstrations and exploration activities towards full commercial lunar surface activities, the ability to expand the original envisioned Artemis power system and repurpose power system components to support commercial activities will be crucial. One technology that will be necessary to support commercial lunar operations is a power grid. A lunar surface power grid would offer the ability to integrate various power sources to maximize power availability, including fission surface power (nuclear), solar arrays, batteries, and regenerative fuel cells. Newly designed terrestrial microgrids are flexible and can be designed to allow for islanded operation, where power is utilized near the loads to minimize power distribution losses or in a power sharing mode where power is transmitted longer distances. This capability is crucial during failures where overall power availability is reduced, and load demand exceeds generation/storage capability. These terrestrial microgrids will also allow for the power system to grow and evolve over time, meeting the need to expand beyond initial lunar surface activities. This presentation will discuss the NASA Artemis plans, potential power system architectures, and power distribution options that will enable growth from initial technology demonstrations towards a lunar economy with a lunar surface power grid that offers many of the advantages of terrestrial microgrids.

Microgrids↗

Self-regulating control of parasitic loads in a fuel cell power system

A fuel cell power system comprises an internal or self-regulating control of a system or device requiring a parasitic load. The internal or self-regulating control utilizes certain components and an interconnection scheme to produce a desirable, variable voltage potential (i.e., power) to a system or device requiring parasitic load in response to varying operating conditions or requirements of an external load that is connected to a primary fuel cell stack of the system. Other embodiments comprise a method of designing such a self-regulated control scheme and a method of operating such a fuel cell power system.

Vasquez, Arturo↗

Testing of Participant's Power Electronics Component for Circuit Performance and Efficiency (CRADA Final Report)

The "Solar SEED Smart Controller is a charge control device to condition solar power to load voltage with or without Battery (also called a "DC Power Platform") invented by David Gibbs and T4D Labs Inc. T4D Inc. and the SEED Smart Controller invention were selected for American Made Challenges Solar Prize, which includes voucher for NREL to provide technical assistance.

14 SOLAR ENERGY↗

Relation of the lunar power system to the SEI program and to landers

The people of Earth will need more than 20,000 billion watts (GWe) of electric power by 2050 for a high level of prosperity. Power needs in the 22nd Century could exceed 100,000 GWe. By 2100 the total quantity of thermal energy used could fully deplete the known inventory (10(exp 7) GWt-Y) of all non-renewable sources on Earth except for deuterium and hydrogen for use in proposed fusion reactors. The labor, capital, and mass of power plants required to produce 1 GWe-Y of energy from present-day power plants is summarized. Fossil and nuclear plants respectively consume 80 to 190 M$ and 12 to 48 M$ of fuel per GWe-Y. The Lunar Power System (LPS) uses solar power bases on the moon to beam electric power to Earth. The LPS in the figure supplies load-following power to rectennas on Earth. Additional solar power conversion units are located across the lunar limb from their respective Earthward transmitting stations. LPS can be augmented by mirrors in polar orbit about the moon. The construction of rectennas on Earth determines the base cost (0.001s$/kWe-H) of LPS power. A manned International Lunar Base (ILB) can accelerate the development of LPS by providing the initial transportation and habitation facilities and base operations. ILB can greatly reduce up front costs and risks by emplacing a moderate scale LPS (1-100 GWe). LPS can accelerate the development of the ILB by providing greater funding than is reasonable to expect for purely scientific research. An international ILB/LPS program can foster world trust and prosperity.

Criswell, David R.↗

Power And Current Bounds For Two Similar Loads

We examine the question of how to obtain bounding power (or current) for two similar loads with an unknown source circuit, but measurements of power (or current) for one load as well as models and measurements of both load impedances.

42 ENGINEERING↗

Comparison of Loads and Aeroacoustics Between Upwind and Downwind Wind Turbine Rotors

This presentation discusses the motivation, preparation, risk mitigation, execution, and results of a full-scale experiment where the rotor of a 1.5 megawatt wind turbine was operated in a downwind configuration. The experiment took place at the National Renewable Energy Laboratory Flatirons Campus in Colorado, USA, and collected conventional loads and power together with acoustic measurements from an array of four microphones. Results from load simulations complement the experiment. Fatigue loads and performance are compared between 410 minutes of downwind operation with 960 minutes of conventional upwind operations. Downwind operations cause an increase in damage equivalent loads in a few load channels. Damage equivalent load of blade root flapwise and edgewise moment and the damage equivalent load of tower base fore aft moment increase between 2% and 20% depending on the wind speed. The comparison in active power is less conclusive, but experimental results show more power in downwind than predicted by simulations. In terms of acoustics, the overall sound pressure levels are similar between upwind and downwind, but downwind worsens the metrics describing amplitude modulation.

aeroacoustics↗

Design of a Two-Body Wave Energy Converter Featuring Controllable Geometry

While the field of wave energy has been the subject of numerical simulation, scale model testing, and precommercial project testing for decades, wave energy technologies remain in the early stages of development and must continue to prove themselves as a promising modern renewable energy field. A wave energy converter (WEC) concept currently being explored is the variable-geometry WEC (VGWEC), which aims to add an extra control option to WEC design. VGWECs attempt to incorporate controllable geometric features to adjust the floating body hydrodynamics to favor either power absorption, load shedding, or other operational goals. These variable geometry components have been proposed to be controlled on a sea-state-to-sea-state or wave-to-wave time scale depending on the force (or torque) and bandwidth limitations of the actuators required to manipulate just the controllable geometric hull features. Having control over both the WEC geometry components and the power takeoff (PTO) offers the potential to improve overall system performance and reliability if a cost-effective solution can be found for a given WEC architecture. This paper will present the recent developments and results of a VGWEC concept that incorporates variable-geometry modules into a two-body WEC. In the proposed VGWEC concept, the variable-geometry modules consist of air-inflatable bags in the surface float and a water inflatable ring in the subsurface body. The surface float is tethered directly to the subsurface body through tether lines, each connected to a separate PTO. Adjusting the geometry of both the surface and subsurface bodies along with the PTO coefficients can maximize power in design sea states while reducing motion response and PTO forces when transitioning to sea states where rated power is reached and load shedding is prioritized. The ability to transition between operating condition is expected to increase the sea state operational map and power capacity.

geometry control↗

Self-powered Heating: Efficiency Analysis

Conventional fuel-fired heating devices such as furnaces, boilers, and water heaters have fuel efficiency less than 100% on the basis of higher heating value. They also require electricity from the electric grid to power parasitic loads such as blowers, pumps, fans, and ignitors. The primary energy efficiency of the device accounts for both fuel used on-site and primary energy used off-site to produce electric power used by the device. This work compares conventional fuel-fired heating devices to two types of self-powered devices. A self-powered device (SPD) integrates a power cycle onboard to eliminate consumption of grid electricity. We assume that all heat rejected by the onboard power cycle is added to the process fluid, so that, compared with a conventional device, the same amount of heat is provided to the process fluid and the same amount of fuel is consumed, but grid electricity consumption is eliminated. The first SPD type is the basic one: exactly the electricity required is generated. The second type considered is the SPD with heat pump (SPD-HP), in which the power cycle generates more electricity than needed for parasitic loads, and the excess electricity is used to power a heat pump. The heat pump extracts additional heat from the ambient to boost efficiency. Both SPD and SPD-HP self-consume all the generated electricity, in contrast to combined heat and power (CHP) systems that export electricity. In this work, equations are derived to express the efficiency of three classes of heating devices: conventional (consuming grid electricity), self-powered (consuming no grid electricity), and self-powered with heat pump. The efficiency of each is derived as a function of up to six factors: (1) the fraction of combustion heat captured, (2) the rate of parasitic power consumption, (3) the fraction of electric energy dissipated as useful heat, (4) the power cycle conversion efficiency, (5) the grid efficiency, when applicable, and (6) the heat pump COP, when applicable. Scenarios are identified in which it is possible to achieve efficiency greater than 100% on a higher heating value basis. Plausible configurations using existing technology options are outlined.

Gluesenkamp, Kyle↗

Modeling of Microgrid for Critical Data Center Applications

As part of continuing efforts to develop support, understanding, and infrastructure of data center integration onto the electric grid, our work aims to model and analyze the behavior of data center loads in a microgrid power system. Our model consists of renewable energy sources, batteries, and a nuclear reactor-steam Rankine cycle to power data center loads. The simulation studies investigate the electrical behavior of the microgrid system to assess its ability in supporting large data center electrical demands.

14 - SOLAR ENERGY↗

Design of a Two-Body Wave Energy Converter Featuring Controllable Geometry: Preprint

While the field of wave energy has been the subject of numerical simulation, scale model testing, and precommercial project testing for decades, wave energy technologies remain in the early stages of development and must continuing proving themselves as a promising modern renewable energy field. A wave energy converter (WEC) concept, currently being explored, is hoping to add an extra control option to WEC design is the variable-geometry WEC (VGWEC). These VGWECs attempt to incorporate controllable geometric features to adjust the floating body hydrodynamics to favor either power absorption, load shedding, or other operational goals. These variable geometry components have been proposed to be controlled on a sea-state-to-sea-state or wave-to-wave time scale depending on the force (or toque) and bandwidth limitations of the actuators required to manipulate just the controllable geometric hull features. The opportunities of having control over both the WEC geometry components and the power-take-off (PTO) have the potential to improve overall system performance and reliability if a cost-effective solution can be found for a given WEC architecture. This paper will present the recent developments and results of a VGWEC concept that incorporates variable geometry modules into a two-body WEC. In the proposed VGWEC concept, the variable geometry modules consist of air inflatable bags in the surface float and a water inflatable ring in the subsurface body. The surface float is tethered directly to the subsurface body through tether lines each connected to a separate PTO. Adjusting the geometry of both the surface and subsurface bodies along with the PTO coefficients can be shown to maximize power in design sea states while reducing motion response and PTO forces when transitioning to sea states where rated power is reached and load shedding is prioritized in hopes of increasing the sea state operational map.

geometry control↗

The effect of yaw on horizontal axis wind turbine loading and performance

The Mod-0 100 kW experimental wind turbine was tested to determine the effects of yaw on rotor power, blade loads and teeter response. The wind turbine was operated for extended periods at yaw angles up to 49 deg to define average or mean response to yaw. It was determined that the effect of yaw on rotor power can be approximated by the cube of the velocity normal to the rotor disc as long as the yaw angle is less than 30 deg. Blade bending loads were relatively unaffected by yaw, but teeter angle increased with wind speed as the magnitude of the yaw angle exceeded 30 deg indicating a potential for teeter stop impacts at large yaw angles. No other adverse effects due to yaw were noted during the tests.

Glasgow, J. C.↗

Financing Microgrids in the Federal Sector

Recent high-impact events such as hurricanes and wildfires highlight the need for energy system resilience. One potential impact of these events is the loss of utility grid power to federal sites, negatively affecting the ability to carry out their missions. Depending on the need to sustain critical functions, it may be important to continue operations during an outage of the electric grid, or at least have power restored quickly after the event. One approach to addressing this need is through a microgrid. Microgrids can provide a more reliable solution than the traditional approach of using a backup generator at individual buildings. A microgrid can enhance a site’s electrical power system during normal operations, as well as provide reliable backup power to critical loads when electric utility power is interrupted. Many times, certain components of a microgrid (and potentially the entire system) can be justified economically and paid for out of energy savings or avoided costs. In cases where savings can cover the project costs, one of several privately financed procurement mechanisms may be used to implement the project. However, it can be difficult to achieve enough savings and avoided costs to cover the entire microgrid system, so leveraging these avoided costs in combination with appropriated funds may be necessary to implement the full project. This paper explores procurement options and agreements that may be useful to federal agencies interested in implementing microgrids at their sites. Microgrid complexities, implementation considerations, and suggestions to get started are also discussed. This information will be most useful to agencies when they are exploring electric energy system resilience options and/or considering different procurement options to meet their needs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Financing Federal Microgrids [Slides]

A microgrid can enhance a site’s electrical power system during normal operations, as well as provide reliable backup power to critical loads when electric utility power is interrupted. When components of a microgrid (and potentially the entire system) can be justified economically and paid for out of energy savings or avoided costs, implementation by one of several privately financed federal procurement mechanisms is possible. However, it is typically difficult to achieve enough savings and avoided costs to cover the design, equipment, and installation of certain microgrid components that are required to integrate the system. This presentation explores procurement options and agreements that may be useful to federal agencies interested in implementing microgrids at their sites. This information will be most useful to agencies when they are exploring electric energy system resilience options and/or considering different procurement options to meet their needs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Self-reconfiguring solar cell system

A self-reconfiguring solar cell array is disclosed wherein some of the cells are switched so that they can be either in series or in shunt within the array. This feature of series or parallel switching of cells allows the array to match the load to achieve maximum power transfer. Automatic control is used to determine the conditions for maximum power operation and to switch the array into the appropriate configuration necessary to transfer maximum power to the load.

Gruber, R. P.↗

Automated Power-Distribution System

Automated power-distribution system monitors and controls electrical power to modules in network. Handles both 208-V, 20-kHz single-phase alternating current and 120- to 150-V direct current. Power distributed to load modules from power-distribution control units (PDCU's) via subsystem distributors. Ring busses carry power to PDCU's from power source. Needs minimal attention. Detects faults and also protects against them. Potential applications include autonomous land vehicles and automated industrial process systems.

Thomason, Cindy↗

Power Electronics as an Enabler of the Current and Future Grid: Control Instead of Copper

Power electronics are becoming more pervasive in the power system. Solar, wind and battery energy storage systems regularly connect to the grid using power electronic interfaces. Loads are also increasingly power electronic-based. These changes, coupled with the change in the power system's operating characteristics as more and more renewable energy is integrated into the power system, offer a challenge to power electronic and power system engineers alike - how do we design and operate the power system moving forward?

direct connect↗