Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Widefield three-dimensional microscopy with a quantum entanglement light source

Devices, systems and methods for widefield three-dimensional (3D) microscopy with a quantum entanglement light source are described. An example method includes generating a first set of photons and a second set of photons, wherein each of the photons in the first set is quantum entangled with a corresponding photon in the second set, directing the second set of photons toward a sample and simultaneously directing the first set of photons toward a first two-dimensional (2D) detector, detecting, from the sample, a plurality of photons at a second 2D detector, analyzing detections from the first and second 2D detectors to determine coincidence information, and determining one or more characteristics associated with at least a three-dimensional (3D) section of the sample based on collective detections at the first and the second 2D detectors.

Bond, Tiziana C.↗

Toward a fully coherent tender and hard X-ray free-electron laser via cascaded EEHG in fourth-generation synchrotron light sources

Free-electron-laser-based beamlines utilize fully coherent laser pulses with extremely narrow bandwidth allowing direct use of X-rays without monochromators. This could be very beneficial for all users of current and future fourth-generation diffraction-limited synchrotron light sources (DL-SLSs) who need narrowband full-coherence high-brightness X-ray pulses. Based on our previous finding, i.e. that separating the two stages of echo-enabled harmonic generation (EEHG) with a few extra bending-magnet sections provides an effective way to increase the momentum compaction of chicane 1, one can simultaneously achieve adequate prebunching at extremely high harmonics as well as keep the energy modulation to the ideal minimum. This could open the door for cascaded EEHG, toward fully coherent tender and hard X-ray wavelengths. Built on our compact design of a twin-pulse seeding electron beam with an adjustable delay and timing jitter at the level of a few femtoseconds, a cascaded EEHG can be implemented, which includes two EEHG beamlines, where the radiation pulse generated by the first beamline with harmonic $h$ 1 could be used as the input seed laser pulse to the second beamline with harmonic $h$ 2 . Hence, the second radiator could potentially reach very high harmonics [$h$ = $h$ 1 (20)$h$ 2 (25–100)] from 500 to 2000, corresponding to tender and hard X-ray wavelengths. It is demonstrated that the cascaded EEHG scheme is compatible with almost any current or planned fourth-generation DL-SLS, with significant benefits for space-limited storage rings in particular. The main advantage is that this scheme requires almost no change of the storage-ring lattice and is fully compatible with other beamlines. Current proposals for rings with much longer straight sections would add self-amplified spontaneous emission as another viable option for storage-ring-based free-electron lasers.

36 MATERIALS SCIENCE↗

Comparative Study of Vibration Stability at Operating Light Source Facilities and Lessons Learned in Achieving NSLS II Stability Goals

In an effort to ensure that the stability goals of the NSLS II will be met once the accelerator structure is set on the selected BNL site a comprehensive evaluation of the ground vibration observed at existing light source facilities has been undertaken. The study has relied on measurement data collected and reported by the operating facilities as well as on new data collected in the course of this study. The primary goal of this comprehensive effort is to compare the green-field conditions that exist in the various sites both in terms of amplitude as well as frequency content and quantify the effect of the interaction of these accelerator facilities with the green-field vibration. The latter represents the ultimate goal of this effort where the anticipated motion of the NSLS II ring is estimated prior to its construction and compared with the required stability criteria.

43 PARTICLE ACCELERATORS↗

A new endstation at the Swiss Light Source for ultraviolet photoelectron spectroscopy, X-ray photoelectron spectroscopy, and X-ray absorption spectroscopy measurements of liquid solutions

A new liquid microjet endstation designed for ultraviolet (UPS) and X-ray (XPS) photoelectron, and partial electron yield X-ray absorption (XAS) spectroscopies at the Swiss Light Source is presented. The new endstation, which is based on a Scienta HiPP-2 R4000 electron spectrometer, is the first liquid microjet endstation capable of operating in vacuum and in ambient pressures up to the equilibrium vapor pressure of liquid water at room temperature. In addition, the Scienta HiPP-2 R4000 energy analyzer of this new endstation allows for XPS measurements up to 7000 eV electron kinetic energy that will enable electronic structure measurements of bulk solutions and buried interfaces from liquid microjet samples. The endstation is designed to operate at the soft X-ray SIM beamline and at the tender X-ray Phoenix beamline. The endstation can also be operated using a Scienta 5 K ultraviolet helium lamp for dedicated UPS measurements at the vapor-liquid interface using either He I or He II α lines. The design concept, first results from UPS, soft X-ray XPS, and partial electron yield XAS measurements, and an outlook to the potential of this endstation are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultra-Low-Emittance Light Sources

In this special issue, we delve into the subject of ultra-low-emittance storage ring light sources. While, these go under various names, such as "diffraction-limited storage rings" and "ultimate storage rings," perhaps the most universally applicable name is "fourth-generation storage rings" or 4GSRs. As this name suggests, these rings promise improvements in X-ray brightness that are comparable to those seen in the transition from second-to third-generation rings.

Borland, Michael↗

ALS-ENABLE: creating synergy and opportunity at the Advanced Light Source synchrotron structural biology beamlines

ALS-ENABLE is an integrated NIH P30 resource at the Advanced Light Source synchrotron at Lawrence Berkeley National Laboratory in Berkeley, California, USA. The resource provides a single portal to the combined mature structural biology technologies of macromolecular crystallography, small-angle X-ray scattering and X-ray footprinting mass spectrometry, and includes beamlines 2.0.1, 3.3.1, 4.2.2, 5.0.1, 5.0.2, 5.0.3, 8.2.1, 8.2.2, 8.3.1 and 12.3.1. This paper describes the organizational structure and the technologies of ALS-ENABLE. A case study showcasing the main technologies of the resource applied to the characterization of the SpyCatcher-SpyTag protein system is presented.

Ralston, Corie Y↗

Recent Developments in Impact and Application to Future Light Sources

This paper discusses two recently added capabilities of the IMPACT suite that are relevant to modeling electron linacs, namely the new 1D coherent synchrotron radiation (CSR) modeling capability and the integrated Green's function (IFG) algorithm for modeling high aspect ratio beams. In addition, we present initial results of application of the enhanced version of IMPACT-Z to high-fidelity modeling of the microbunching instability in a realistic light source lattice.

43 PARTICLE ACCELERATORS↗

Monte Carlo Studies of the Radiation Fields in the Linac Coherent Light Source Undulators and of the Corresponding Signals in the Cerenkov Beam Loss Monitors

In 2009 the Linac Coherent Light Source (LCLS) at the SLAC National Accelerator Center started free electron laser (FEL) operation. In order to continue to produce the bright and short-pulsed x-ray laser demanded by FEL scientists, this pioneer hard x-ray FEL requires a perfectly tailored magnetic field at the undulators, so that the photons generated at the electron wiggling path interact at the right phase with the electron beam. In such a precise system, small (>0.01%) radiation-induced alterations of the magnetic field in the permanent magnets could affect FEL performance. This paper describes the simulation studies of radiation fields in permanent magnets and the expected signal in the detectors. The transport of particles from the radiation sources (i.e. diagnostic insert) to the undulator magnets and to the beam loss monitors (BLM) was simulated with the intra nuclear cascade codes FLUKA and MARS15. In order to accurately reproduce the optics of LCLS, lattice capabilities and magnetic fields were enabled in FLUKA and betatron oscillations were validated against reference data. All electron events entering the BLMs were printed in data files. The paper also introduces the Radioactive Ion Beam Optimizer (RIBO) Monte Carlo 3-D code, which was used to read from the event files, to compute Cerenkov production and then to simulate the optical coupling of the BLM detectors, accounting for the transmission of light through the quartz.

COMP, SAFETY, XFEL, OTHER↗

Compact fiber-coupled narrowband two-mode squeezed light source

Quantum correlated states of light, such as squeezed states, are a fundamental resource for the development of quantum technologies, as they are needed for applications in quantum metrology, quantum computation, and quantum communications. It is thus critical to develop compact, efficient, and robust sources to generate such states. Here, we report on a compact, narrowband, fiber-coupled source of two-mode squeezed states of light at 795 nm based on four-wave mixing (FWM) in an 85 Rb atomic vapor. The source is designed in a small modular form factor, with two input fiber-coupled beams, the seed and pump beams required for the FWM, and two output fibers, one for each of the modes of the squeezed state. The system is optimized for low pump power (135 mW) to achieve a maximum intensity-difference squeezing of 4.4 dB after the output of fibers at an analysis frequency of 1 MHz. Furthermore, the narrowband nature of the source makes it ideal for atomic-based quantum sensing and quantum networking configurations that rely on atomic quantum memories. Such a source paves the way for a versatile and portable platform for applications in quantum information science.

Jain, Umang [University of Oklahoma, Norman, OK (U↗

Fresnel cup reflector directs maximum energy from light source

To minimize shielding and overheating, a composite Fresnel cup reflector design directs the maximum energy from a light source. It consists of a uniformly ellipsoidal end surface and an extension comprising a series of confocal ellipsoidal and concentric spherical surfaces.

Laue, E. G.↗

National Synchrotron Light Source 2008 Activity Report

Funded by the U.S. Department of Energy's Office of Basic Energy Sciences, the National Synchrotron Light Source (NSLS) is a national user facility that operates two electron storage rings: X-Ray (2.8 GeV, 300 mA) and Vacuum Ultraviolet (VUV) (800 mev, 1.0A). These two rings provide intense light spanning the electromagnetic spectrum -- from very long infrared rays to ultraviolet light and super-short x-rays -- to analyze very small or highly dilute samples. The properties of this light, and the specially designed experimental stations, called beamlines, allow scientists in many diverse disciplines of research to perform experiments not possible at their own laboratories. Each year, about 2,200 scientists from more than 400 universities and companies use the NSLS for research in such diverse fields as biology, physics, chemistry, geology, medicine, and environmental and materials sciences. For example, researchers have used the NSLS to examine the minute details of computer chips, decipher the structures of viruses, probe the density of bone, determine the chemical composition of moon rocks, and reveal countless other mysteries of science. The facility has 65 operating beamlines, with 51 beamlines on the X-Ray Ring and 14 beamlines on the VUV-Infrared Ring. It runs seven days a week, 24 hours a day throughout the year, except during periods of maintenance and studies. Researchers are not charged for beam time, provided that the research results are published in open literature. Proprietary research is conducted on a full-cost-recovery basis. With close to 1,000 publications per year, the NSLS is one of the most prolific scientific facilities in the world. Among the many accolades given to its users and staff, the NSLS has won nine R&D 100 Awards for innovations ranging from a closed orbit feedback system to the first device able to focus a large spread of high-energy x-rays. In addition, a visiting NSLS researcher shared the 2003 Nobel Prize in Chemistry for work explaining how one class of proteins helps to generate nerve impulses.

43 PARTICLE ACCELERATORS↗

X-ray imaging of subsurface dynamics in high-Z materials at the Diamond Light Source

In this paper, we describe a new approach enabling study of subsurface dynamics in high-Z materials using the unique combination of high-energy synchrotron X-rays, a hybrid bunch structure, and a new dynamic loading platform. We detail the design and operation of the purpose-built, portable small bore gas-gun, which was installed on the I12 high-energy beamline at the Diamond Light Source and used to drive compression waves into solid and porous metal targets. Using a hybrid bunch structure and broadband X-ray pulses of up to 300 keV, radiographic snapshots were captured during various dynamic deformation processes in cm-scale specimens, thereby contributing to a more complete understanding of the evolution of mesoscale damage. Importantly, we highlight strategies for overcoming the challenges associated with using high-energy X-rays, and suggest areas for improvement needed to advance dynamic imaging through large-scale samples of relevance to engineering scenarios. These preliminary measurements demonstrate the feasibility of probing highly transient phenomena using the presented methodology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Higher Order Suppressor (HOS) for the PolLux Microspectroscope Beamline at the Swiss Light Source SLS

The mechanical design and performance of a device to suppress higher orders of a spherical grating monochromator at a constant deviation angle is described. The higher order suppressor (HOS) is used for a scanning transmission x-ray microspectroscope beamline (PolLux) at a bending magnet of the Swiss Light Source (SLS). The instruments allow microspectroscopy in polymer science, of biological samples in the water window as well as the study of magnetic materials with circular or linear polarized light in a photon energy range of 200 eV to 1400 eV. The HOS uses three mirrors acting as a low pass filter for soft x-rays to improve the absorption spectroscopy of carbon, oxygen and nitrogen 1s core levels. The successful installation and operation of the HOS located after the monochromator is reported. First results obtained using samples from materials research and environmental sciences exemplify the improved spectroscopy capabilities of the instrument.

43 PARTICLE ACCELERATORS↗

Data systems for the Linac coherent light source

Abstract The data systems for X-ray free-electron laser (FEL) experiments at the Linac coherent light source (LCLS) are described. These systems are designed to acquire and to reliably transport shot-by-shot data at a peak throughput of 5 GB/s to the offline data storage where experimental data and the relevant metadata are archived and made available for user analysis. The analysis and monitoring implementation (AMI) and Photon Science ANAlysis (psana) software packages are described. Psana is open source and freely available.

97 MATHEMATICS AND COMPUTING↗

Dielectric Wakefield Accelerator to drive the future FEL Light Source.

X-ray free-electron lasers (FELs) are expensive instruments and a large part of the cost of the entire facility is driven by the accelerator. Using a high-energy gain dielectric wake-field accelerator (DWA) instead of the conventional accelerator may provide a significant cost saving and reduction of the facility size. In this article, we investigate using a collinear dielectric wakefield accelerator to provide a high repetition rate, high current, high energy beam to drive a future FEL x-ray light source. As an initial case study, a {approx}100 MV/m loaded gradient, 850 GHz quartz dielectric based 2-stage, wakefield accelerator is proposed to generate a main electron beam of 8 GeV, 50 pC/bunch, {approx}1.2 kA of peak current, 10 x 10 kHz (10 beamlines) in just 100 meters with the fill factor and beam loading considered. This scheme provides 10 parallel main beams with one 100 kHz drive beam. A drive-to-main beam efficiency {approx}38.5% can be achieved with an advanced transformer ratio enhancement technique. rf power dissipation in the structure is only 5 W/cm{sup 2} in the high repetition rate, high gradient operation mode, which is in the range of advanced water cooling capability. Details of study presented in the article include the overall layout, the transform ratio enhancement scheme used to increase the drive to main beam efficiency, main wakefield linac design, cooling of the structure, etc.

36 MATERIALS SCIENCE↗

Rapid and efficient ambient temperature X-ray crystal structure determination at Turkish Light Source

High-resolution biomacromolecular structure determination is essential to better understand protein function and dynamics. Serial crystallography is an emerging structural biology technique which has fundamental limitations due to either sample volume requirements or immediate access to the competitive X-ray beamtime. Obtaining a high volume of well-diffracting, sufficient-size crystals while mitigating radiation damage remains a critical bottleneck of serial crystallography. As an alternative, we introduce the plate-reader module adapted for using a 72-well Terasaki plate for biomacromolecule structure determination at a convenience of a home X-ray source. We also present the first ambient temperature lysozyme structure determined at the Turkish light source (Turkish DeLight). The complete dataset was collected in 18.5 min with resolution extending to 2.39 Å and 100% completeness. Combined with our previous cryogenic structure (PDB ID: 7Y6A), the ambient temperature structure provides invaluable information about the structural dynamics of the lysozyme. Turkish DeLight provides robust and rapid ambient temperature biomacromolecular structure determination with limited radiation damage.

59 BASIC BIOLOGICAL SCIENCES↗