Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “light pulses”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Application of optical correlation techniques to particle imaging velocimetry

Pulsed laser sheet velocimetry yields nonintrusive measurements of velocity vectors across an extended 2-dimensional region of the flow field. The application of optical correlation techniques to the analysis of multiple exposure laser light sheet photographs can reduce and/or simplify the data reduction time and hardware. Here, Matched Spatial Filters (MSF) are used in a pattern recognition system. Usually MSFs are used to identify the assembly line parts. In this application, the MSFs are used to identify the iso-velocity vector contours in the flow. The patterns to be recognized are the recorded particle images in a pulsed laser light sheet photograph. Measurement of the direction of the partical image displacements between exposures yields the velocity vector. The particle image exposure sequence is designed such that the velocity vector direction is determined unambiguously. A global analysis technique is used in comparison to the more common particle tracking algorithms and Young's fringe analysis technique.

Wernet, Mark P.↗

Application of optical correlation techniques to particle imaging

Pulsed laser sheet velocimetry yields noninstrusive measurements of velocity vectors across an extended 2-dimensional region of the flow field. The application of optical correlation techniques to the analysis of multiple exposure laser light sheet photographs can reduce and/or simplify the data reduction time and hardware. Here, Matched Spatial Filters (MSF) are used in a pattern recognition system. Usuallay MSFs are used to identify the assembly line parts. In this application, the MSFs are used to identify the iso-velocity vector contours in the flow. The patterns to be recognized are the recorded particle images in a pulsed laser light sheet photograph. Measurement of the direction of the particle image displacements between exposures yields the velocity vector. The particle image exposure sequence is designed such that the velocity vector direction is determined unambiguously. A global analysis technique is used in comparison to the more common particle tracking algorithms and Young's fringe analysis technique.

Wernet, Mark P.↗

A measurement of the fast luminescent decays of the MV-50 LED.

The fast luminescent decay of the MV-50 GaAs doped Si light-emitting diode has been studied. This diode is found to provide a fast, inexpensive, bright, and convenient light source for the calibration of fast optical timing systems. A simple passive electronic module is described that allows driving the light source directly by a laboratory pulse generator.

Sutton, J. F.↗

Interpretation of the pulsed gamma-ray emission from Vela

A model is proposed for the Vela pulsar in which the radio emission originates near the surface of the neutron star while the pulsed gamma-ray emission is produced by synchrotron radiation near the speed-of-light cylinder. This model can explain the energy flux, double pulse structure, and phase shift (with respect to the radio) of the gamma-ray emission, and offers approximate quantitative predictions for other X- and gamma-ray fluxes.

Thompson, D. J.↗

Lidar meteorology

Current and future lidar applications to meteorological studies are presented. In water vapor, temperature, and pressure measurement applications, differential absorption lidar (DIAL) techniques are used, employing a minimum of two wavelengths. The DIAL technique has proven particularly accurate in pressure measurements. For wind measurements, lidar investigations generally use the Doppler shifting of laser light backscattered from aerosols, and a pulsed low-power CO2 Doppler lidar is being developed for airborne platform applications. At visible to near-infrared wavelengths, spatial distribution of aerosol and clouds can be obtained from lidar, and this information can help determine such atmospheric parameters as mixed layer height and cloud height distributions. A Shuttle lidar facility, being developed for the end of the 1980's, will enable laser remote sensing techniques to be applied to studies of the lower atmosphere.

Browell, E. V.↗

Shutter For VPPA-Welding Vision System

Conceptual electro-optical shutter subsystem regulates intensity of light entering video camera from variable-plasma-pulse-arc weld in process. Camera part of video system that enables welding technician to obtain better view of weld bead and puddle in light of arc. Electro-optical shutter opened during low-illumination viewing intervals near zero crossings of welding current, preventing overloading of video camera.

Lirette, Murray J.↗

Recent developments in Stirling and pulse tube coolers for spacecraft applications

Recent progress toward the development of light weight, long life coolers is presented. In particular, programs underway in the United States to develop Stirling cycle coolers and pulse tube coolers are described. The potential availability of reliable, long lifetime coolers for space applications is discussed.

Castles, Stephen↗

Chemical analyses of provided samples

A batch of four samples were received and chemical analysis was performed of the surface and near surface regions of the samples by the surface analysis by laser ionization (SALI) method. The samples included four one-inch diameter optics labeled windows no. PR14 and PR17 and MgF2 mirrors 9-93 PPPC exp. and control DMES 26-92. The analyses emphasized surface contamination or modification. In these studies, pulsed desorption by 355 nm laser light and single-photon ionization (SPI) above the sample by coherent 118 nm radiation (at approximately 5 x 10(exp 5) W/cm(sup 2)) were used, emphasizing organic analysis. For the two windows with an apparent yellowish contaminant film, higher desorption laser power was needed to provide substantial signals, indicating a less volatile contamination than for the two mirrors. Window PR14 and the 9-93 mirror showed more hydrocarbon components than the other two samples. The mass spectra, which show considerable complexity, are discussed in terms of various potential chemical assignments.

Becker, Christopher H.↗

Nd:YLF laser for airborne/spaceborne laser ranging

In order to meet the need for light weight, long lifetime, efficient, short pulse lasers, a diode-pumped, Nd:YLF oscillator and regenerative amplifier is being developed. The anticipated output is 20 mJ per 10 picosecond pulse, running at a repetition rate of 40 Hz. The fundamental wavelength is at 1047 nm. The oscillator is pumped by a single laser diode bar and mode locked using an electro-optic, intra-cavity phase modulator. The output from the oscillator is injected as a seed into the regenerative amplifier. The regenerative amplifier laser crystal is optically pumped by two 60W quasi-cw laser diode bars. Each diode is collimated using a custom designed micro-lens bar. The injected 10 ps pulse from the oscillator is kept circulating within the regenerative amplifier until this nanojoule level seed pulse is amplified to 2-3 millijoules. At this point the pulse is ejected and sent on to a more standard single pass amplifier where the energy is boosted to 20 mJ. The footprint of the entire laser (oscillator-regenerative amplifier-amplifier) will fit on a 3 by 4 ft. optical pallet.

Dallas, Joseph L.↗

Laser-Induced Incandescence Calibration via Gravimetric Sampling

Various beam imaging and/or sheet forming optics delivered light at 1064 nm from a pulsed Nd:YAG laser for use either as a beam of 3 mm radius or as a laser sheet. Imaging measurements were performed with a grated intensified array camera equipped with an ultraviolet f4.5 lens and a 40 mm extension tube. Point measurements were performed using an ultraviolet 250 mm focal length lens to collect and focus the laser induced incandescence (LII) signal into a 1 meter long quartz optical fiber which directed the LII signal to a 1/4 meter monochromator. An aperture preceding the lens restricted the signal collection region to 1 cm along the laser beam at the center of the gravimetric chimney. Signals from the PMT were processed by a boxcar integrator whereas the images were captured digitally using a frame-grabber with 16 MByte of on-board memory. Both 'point' and planar measurements were made with detector gates of 250 ns to minimize possible morphology bias in collection of the LII signal. Additionally, the imaging measurements were performed with broadband spectral collection of the LII signal to maximize the signal and again minimize any potential effects of morphology dependent heating and/or cooling rates. Digital delay generators controlled the firing of he laser, detector gates and data acquisition. Neutral density filters were used for both sets of measurements to maintain signal levels within linear dynamic ranges of the detectors, the range being determined prior to experiments.

VanderWal, R. L.↗

The response of thermally and optically stimulated luminescence from Al2O3:C to high-energy heavy charged particles

The thermoluminescence (TL) and optically stimulated luminescence (OSL) response of Al2O3 dosimeters to high-energy heavy charged particles (HCP) has been studied using the heavy ion medical accelerator at Chiba, Japan. The samples were Al2O3 single-crystal chips, of the type usually known as TLD-500, and Luxel(TM) dosimeters (Al2O3:C powder in plastic) from Landauer Inc. The samples were exposed to 4He (150 MeV/u), 12C (400 MeV/u), 28Si (490 MeV/us) and 56Fe (500 MeV/u) ions, with linear energy transfer values covering the range from 2.26 to 189 keV/micrometers in water and doses from 1 to 100 mGy (to water). A 90Sr/90Y beta source, calibrated against a 60Co secondary standard, was used for calibration purposes. For OSL, we used both continuous-wave OSL measurements (CW-OSL, using green light stimulation at 525 nm) and pulsed OSL measurements (POSL, using 532 nm stimulation from a Nd:YAG Q-switched laser). The efficiencies (eta HCP, gamma) of the different HCPs at producing OSL or TL were observed to depend not only upon the linear energy transfer (LET) of the HCP, but also upon the sample type (single crystal chip or Luxel(TM)) and the luminescence method used to define the signal--i.e. TL, CW-OSL initial intensity, CW-OSL total area, or POSL. Observed changes in shape of the decay curve lead to potential methods for extracting LET information of unknown radiation fields. A discussion of the results is given, including the potential use of OSL from Al2O3 in the areas of space radiation dosimetry and radiation oncology. c2004 Elsevier Ltd. All rights reserved.

Heavy Ions↗

Discovery of a 105-ms X-ray Pulsar in Kesteven-79: On the Nature of Compact Central Objects in Supernova Remnants

We report the discovery of 105-ms X-ray pulsations from the compact central object (CCO) in the supernova remnant \snr\ using data acquired with the {\it Newton X-Ray Multi-Mirror Mission). Using two observations of the pulsar taken 6-days apart we derive an upper limit on its spin-down rate of $\dot P < 9 \times 10"{-14}$-s-~$~{-l)$,a nd find no evidence for binary orbital motion. The implied energy loss rate is $\dot E < 3 \times 10A{36)$-ergs-s$A{-1)$, polar magnetic field strength is $B-{\rm p) < 3 \times 10A{12)$-G, and spin-down age is $\tau > 18.5$-kyr. The latter exceeds the remnant's estimated age, suggesting that the pulsar was born spinning near its current period. The X-ray spectrum of \psr\ is best characterized as a blackbody of temperature $kT {BB) =, 0.43\pm0.02$ keV, radius $R-{BB) \approx 1.3$-km, and $~I{\rm bol) = 5.2 \times 10A{33)$ ergs-sSA{-1)$ at $d = 7.1$-kpc. The sinusoidal light curve is modulated with a pulsed fraction of $>45\%$, suggestive of a small hot spot on the surface of the rotating neutron star. The lack of a discernible pulsar wind nebula is consistent with an interpretation of \psr\ as a rotation-powered pulsar whose spin-down luminosity falls below the empirical threshold for generating bright wind nebulae, $\dot E-{\rm c) = 4 \times 10A{36)$-ergs-sSA{-I)$. The age discrepancy suggests that its $\dot E$ has always been below $\dot E c$, perhaps a distinguishing property of the CCOs. Alternatively, the X-ray spectrum of \psr\ suggests a low-luminosity AXP, but the weak inferred $B-{\rm p)$ field is incompatible with a magnetar theory of its X-ray luminosity. The ordinary spin parameters discovered from \psr\ highlight the inability of existing theories to explain the high luminosities and temperatures of CCO thermal X-ray spectra.

Gotthelf, E. V.↗

Lunar-surface UV Photometric Investigation of Exospheres (LUPINE): Thermal Modeling of Payload in a Relevant Daylit Environment

Direct upward remote sensing of the moon’s exosphere from a surface vantage can address production of water-related lunar volatiles as well as their exospheric loss, ballistic transport, and ultimate adsorption in permanently shadowed regions (PSRs). Far UV (FUV) dayside measurements of atomic oxygen, liberated from regolith by energetic solar protons and micrometeorite impact, can provide critical insight into the endogenic lunar water cycle by constraining total column density [O] at site of production. A notional Lunar-surface UV Photometric Investigation of Exospheres (LUPINE) instrument is designed to exploit solar-pumped atomic oxygen fluorescence at 130.4-nm, in a manner similar to the Apollo 17 UV Spectrometer (UVS) experiment [Fastie 1973; Feldman and Morrison, 1991] and the LRO Lyman-alpha Mapping Project (LAMP) spectrograph [Cook et al., 2013], by implementing a zenith-directed FUV photometer from the lunar surface at low (± 10°) selenographic latitude during the lunar day. Atomic oxygen production from solar energetic particle impact sources is thought to maximize in near solar noon [Sarantos et al., 2012], and the lander-embedded zenith-directed LUPINE photometer, in contrast to UVS and LAMP twilight measurements from orbit, can potentially capture the full column abundance of lunar regolith liberated oxygen. Herein we describe adaptation of FUV reflective optics, pulse-counting electronics, and scattered-light-suppression technologies developed for LEO FUV photometry for the challenging thermal environment of the daylit lunar surface. Preliminary thermal modeling and TVAC measurements of heritage FUV photometer components suggests that, if allowed to shed ~8W of waste heat into the bus of a reference Commercial Lunar Payload Services (CLPS) lander, the LUPINE photometer will be kept sufficiently cool to limit dark current to less than 20 counts/s. This level of dark signal enables an OI 130.4-nm 3-sigma detection threshold of ~1 mR for assumed 2-hour integrations.

Lunar UV Photometer↗

Reliable Ignition of LOX-LCH4 Propellants

No cryogenic Reaction Control System (RCS) has ever flown in space. Cryogenic propellants are baselined by HLS and CLPS partners and are the key use case for future ISRU manufactured propellants. A reliable LOX/LCH 4 RCS is an enabling technology for human Lunar and Mars exploration. In previous thermal vacuum (<275 F, <10 torr) testing at NASA GRC Plum Brook, the team uncovered anomalous LOX/LCH4 engine ignition phenomena where flame kernels quenched at these ultra cold hardware temperatures, leading to many pulses where the engines would not light. In 2022, the project was able to recreate the no light condition with an upgraded Frost-Mint test stand at JSC. This project implemented test stand improvements and procured propellants and follow on engine components for a hot fire campaign beginning in November 2024 which will attempt to ignite the RCS engine at ultra cold vacuum conditions by modifying the engine mixture ratio. New modeling techniques were implemented to account for past no lights and are an enabling method to make lunar surface go no go predictions based on hardware conditions. This was enabled by significant improvements to the Frost Mint system, which reduced moisture build up and leaks, increased propellant availability, leading to more attempts at thermal vacuum hot-fires.

Propulsion↗

A mechanism for the production of pulsar radio radiation

Recent theoretical studies have suggested that avalanches of electron-positron pairs are produced by spark discharges near the magnetic poles of pulsars. This pair production mechanism may result in a double-peaked particle distribution function. We investigate collective effects caused by a high-energy electron-positron beam traversing a low-energy electron-positron plasma for an astrophysically interesting range of physical parameters. The principal result of this paper is to identify transverse unstable waves whose phase propagation may occur at any arbitrary angle (other than zero) with respect to the magnetic field but whose group velocity is along the magnetic field and approximately the speed of light. It is suggested that the observed radio pulses from pulsars may be caused by the focusing of these transverse waves along the open field lines extending from a pulsar's polar cap to the light cylinder.

Hardee, P. E.↗

Geoscience Laser Altimeter System: Characteristics and Performance of the Altimeter Receiver

The Geoscience Laser Altimeter System (GLAS) on board ICESat spacecraft measures the surface height (altimetry) via the time of flight of its 1064 nm laser pulse. The GLAS laser transmitter produces 6 ns wide pulses with 70 mJ energy at 1064 nm at a 40 Hz rate. The altimeter receiver consists of a telescope, aft optics, a silicon avalanche photodiode, and electronic amplifiers. The transmitted and echo pulse waveforms are digitized at 1 GHz rate. The laser pulse time of flight is determined on the ground from the two digitized pulse waveforms and their positions in the full waveform record (about 5.4 ms ong) by computing the pulse centroids or by curve fitting. The GLAS receiver algorithms in on board software selects the two waveform segments containing the transmitted and the echo pulses and sends them to ground. The probability of echo pulse detection and the accuracy of time of flight measurement depend on the received signal level, the background light within the receiver field of view, the inherent detector and amplifier noise, the quantization of the digitizer, and some times by cloud obscurations. A receiver model has been developed to calculate the probability of detection and accuracy of the altimeter measurements with these noise sources. From prelaunch testing, the minimum detectable echo pulse energy for 90% detection probability was about 0.1 fj/pulse onto the detector. Such a receiver sensitivity allows GLAS to measure the surface height through clouds with optical density less than 2. The echo pulse energy required to achieve 10 cm ranging accuracy was found to be about 3 times higher than the minimum detectable signal level. The smallest single shot range measurement error, which was determined by ranging to a fixed target with strong echo pulses and no background light, was 2 to 3cm. The maximum linear response echo pulse energy was 10 fJ/pulse for the strongest echo signals, assuming a Lambertian scattering snow surface, clear sky atmosphere transmission, and no pulse width spreading due to surface slopes. Results from the initial 38 days of GLAS operation on-orbit with Laser 1, showed the echo pulse energies varied, as expected, over a wide dynamic range due to the variability of atmosphere transmission and Earth surface characteristics. The receiver was able to reliably detect the ground surface echoes and measure time of flight under such dynamic conditions, except when there were dense clouds. When over Antarctica, the echo pulse energies were several times stronger than predicted. This suggests that the 1064 nm backscattering from the snow pack and ice-sheet &ce are not completely Lambertian but is somewhat peaked at opposit.ion. With Laser 1, the peak amplitude of the echo pulses from flat ice sheets under clear sky conditions exceeded the linear response range of the receiver, causing some pulse waveform distortion due to saturation. We have characterized the effects of receiver saturation on the time of flight, pulse width, and pulse energy measurements for flat surface by testing a night spare detector in the lab with simulated echo pulses. A data processing algorithm that minimizes the errors due to saturation for these measurements are described.

Sun, Xiao-Li↗

Cloud Thickness from Diffusion of Lidar Pulses in Clouds

Measurements of the distribution of reflected light from a laser beam incident on an aqueous suspension of particles or "cloud" with known thickness and particle size distribution are reported. The distribution is referred to as the "cloud radiative Green's function", G. In the diffusion domain, G is sensitive to cloud thickness, allowing that important quantity to be retrieved. The goal of the laboratory simulation is to provide preliminary estimates of sensitivity of G to cloud thickness,for use in the optimal design of an offbeam Lidar instrument for remote sensing of cloud thickness (THOR, Thickness from Offbeam Returns). These clouds of polystyrene microspheres suspended in water are analogous to real clouds of water droplets suspended in air. The microsphere size distribution is roughly lognormal, from 0.5 microns to 25 microns, similar to real clouds. Density of suspended spheres is adjusted so mean-free-path of visible photons is about 10 cm, approximately 1000 times smaller than in real clouds. The light source is a ND:YAG laser at 530 nm. Detectors are flux and photon-counting Photomultiplier Tube (PMTS), with a glass probe for precise positioning. A Labview 5 VI controls positioning, and data acquisition, via an NI Motion Control board connected to a stepper motor driving an Edmund linear slider, and a 16-channel 16-bit NI-DAQ board. The stepper motor is accurate to 10 microns, and step size is selectable from the VI software. Far from the incident beam, the rate of exponential increase as the direction of the incident beam is approached scales as expected from diffusion theory, linearly with the cloud thickness, and inversely as the square root of the reduced optical thickness, and is independent of particle size. Near the beam the signal begins to increase faster than exponential, due to single and low-order scattering near the backward direction, and here the distribution depends on particle size. Results are being used to verify 3D Monte Carlo radiative transfer simulations, used to estimate signal-to-noise ratios for remotely sensed off beam returns, for both homogeneous and inhomogeneous clouds. Signal-to-noise estimates show that unfiltered observations are straight forward at night, while narrow band pass filters are being studied for day.

Cahalan, Robert F.↗

The detection of pulsed X-ray emission from a nearby radio pulsar

As part of a search for thermal surface radiation from nearby neutron stars, we have carried out a 45,000 s observation of the nearby radio pulsar PSR 1929+10 with the ROSAT PSPC. After background subtraction, a net of 420 +/- 25 photons in the 0.1 to 2.0 keV band were detected at the position of the pulsar, corresponding to a luminosity of 1.2 x 10(exp 30) ergs/sec for a source distance of 250 pc, or approximately 3 x 10(exp -4) of the pulsar's spin-down luminosity. We find coherent pulsations from PSR 1929+10 at the radio period of 0.2265 s. The folded light curve is well fitted by a sinusoidal oscillation with a pulsed fraction of about 30%. The total spectrum is fitted by a blackbody with a temperature T(sub infinity) approximately equals 3.2 x 10(exp 6) K; the implied emitting area has a radius of less than 50 m. The maximum of the X-ray light curve coincides with the radio pulse, suggesting that we are detecting the hot magnetic polar cap of the star. The temperature limit for the remainder of the stellar surface is T(sub infinity) less than 3 x 10(exp 5) K. The spatial distribution of the photons is consistent with the instrument point-spread function. We discuss the implications of these results for the temperature distribution over the surface of the star and use this detection to constrain various heating mechanisms for rotation-powered neutron stars. We also use a simple model of general relativistic light bending near the stellar surface in conjunction with the radio emission geometry and the X-ray pulsed fraction to derive a radius for the neutron star of R = 9 +/- 3 km.

Yancopoulos, S.↗