A Two-Step Time-Series Data Clustering Method for Building-Level Load Profile

Residential and commercial buildings have huge potential to contribute value to improve grid resilience by participating grid services. To reveal the significant value, it is critical to estimate the grid service capability from these buildings. Unlike the large-scale distributed energy resources such as wind and solar farms, those buildings need to participate grid services in aggregation, not by individual. Therefore, it is important to appropriately group buildings for aggregation. The load profiles in the same group will have similar characteristics at the same time step, so grid operators can send the grid service signal to the customer group with a higher chance to respond at that time step. In this paper, we develop a load profile clustering method to classify the building-level load profiles for grid service capability estimation. In our two-step clustering approach, we first calculate the total load consumption for each building, clustering the load profiles based on energy consumption level. Then, we further cluster the load profiles in each energy cluster based on the load shape. The parameter selection for each clustering step is discussed. The proposed method is applied on actual building-level load profiles, and the results have proved the effectiveness of this method.

advanced metering infrastructure (AMI)↗

Commercialization of Distribution System Load Modeling Tool for Improved DER Interconnection Studies

Residential and commercial buildings have huge potential to contribute value to improve grid resilience by participating grid services. To reveal the significant value, it is critical to estimate the grid service capability from these buildings. Unlike the large-scale distributed energy resources such as wind and solar farms, those buildings need to participate grid services in aggregation, not by individual. Therefore, it is important to appropriately group buildings for aggregation. The load profiles in the same group will have similar characteristics at the same time step, so grid operators can send the grid service signal to the customer group with a higher chance to respond at that time step. In this paper, we develop a load profile clustering method to classify the building-level load profiles for grid service capability estimation. In our two-step clustering approach, we first calculate the total load consumption for each building, clustering the load profiles based on energy consumption level. Then, we further cluster the load profiles in each energy cluster based on the load shape. The parameter selection for each clustering step is discussed. The proposed method is applied on actual building-level load profiles, and the results have proved the effectiveness of this method.

14 SOLAR ENERGY↗

A Two-Step Time-Series Data Clustering Method for Building-Level Load Profile

Residential and commercial buildings have huge potential to contribute value to improve grid resilience by participating grid services. To reveal the significant value, it is critical to estimate the grid service capability from these buildings. Unlike the large-scale distributed energy resources such as wind and solar farms, those buildings need to participate grid services in aggregation, not by individual. Therefore, it is important to appropriately group buildings for aggregation. The load profiles in the same group will have similar characteristics at the same time step, so grid operators can send the grid service signal to the customer group with a higher chance to respond at that time step. In this paper, we develop a load profile clustering method to classify the building-level load profiles for grid service capability estimation and the results have proved the effectiveness of this method.

AMI↗

A Two-Step Time-Series Data Clustering Method for Building-Level Load Profile: Preprint

Residential and commercial buildings have huge potential to contribute value to improve grid resilience by participating grid services. To reveal the significant value, it is critical to estimate the grid service capability from these buildings. Unlike the large-scale distributed energy resources such as wind and solar farms, those buildings need to participate grid services in aggregation, not by individual. Therefore, it is important to appropriately group buildings for aggregation. In this paper, we develop a load profile clustering method to classify the building-level load profiles for grid service capability estimation. In our two-step clustering approach, we first calculate the total load consumption for each building, clustering the load profiles based on energy consumption level. Then, we further cluster the load profiles in each energy cluster based on the load shape. The parameter selection for each clustering step is discussed. The proposed method is applied on actual building-level load profiles, and the results have proved the effectiveness of this method.

advanced metering infrastructure (AMI)↗

Virtual Dynamic Grid Impedance and Its Impacts on Harmonics and Stability of Inverter Based Resources Plant

Nowadays, a large number of inverter-based resources (IBRs) are integrated into the grid at a single connection point as an IBR plant. In this article, a virtual dynamic grid impedance concept is introduced to evaluate the harmonics and stability for grid integration of an IBR plant containing multiple IBRs. First, a detailed theoretical study is conducted to build a foundation of the virtual grid impedance concept, which is a dynamic impedance that changes with the number of IBRs added into an IBR plant. Then, based on the new virtual dynamic grid impedance concept, frequency spectrum analysis is performed to explore harmonic impact at the interconnection point for an IBR plant with IBRs having L, LC, and LCL filters, respectively. An electromagnetic transient (EMT) simulation model of a grid-connected IBR plant is developed to explore the harmonics and stability of the IBR plant connected to the grid as well as the reliable operation of IBRs within the plant from the novel virtual equivalent dynamic grid impedance point of view. Hardware experiments are conducted to validate the EMT simulation evaluation. The results show that the number of IBRs added into an IBR plant influences the grid impedance, i.e., grid strength, and the grid impedance variation has multiple impacts on the IBR plant and IBRs within the plant depending on the grid-connected filters of the IBRs.

grid impedance↗

Risk-Constrained Reinforcement Learning for Inverter-Dominated Power System Controls

Here, this paper develops a risk-aware controller for grid-forming inverters (GFMs) to minimize large frequency oscillations in GFM inverter-dominated power systems. To tackle the high variability from loads/renewables, we incorporate a mean-variance risk constraint into the classical linear quadratic regulator (LQR) formulation for this problem. The risk constraint aims to bound the time-averaged cost of state variability and thus can improve the worst-case performance for large disturbances. The resulting risk-constrained LQR problem is solved through the dual reformulation to a minimax problem, by using a reinforcement learning (RL) method termed as stochastic gradient-descent with max-oracle (SGDmax). In particular, the zero-order policy gradient (ZOPG) approach is used to simplify the gradient estimation using simulated system trajectories. Numerical tests conducted on the IEEE 68-bus system have validated the convergence of our proposed SGDmax for GFM model and corroborate the effectiveness of the risk constraint in improving the worst-case performance while reducing the variability of the overall control cost.

Frequency control↗

Data Center Power Systems: Architectures, Impact on Grid Reliability, Modeling Considerations, and Megawatt-Scale Hardware Testing [Slides]

This slide deck describes typical power systems of large datacenters along with reliability problems to bulk power systems from large-scale integration of datacenters. The slide deck covers the architecture of datacenter power systems, different power electronic converters used inside datacenters, their operation modes, and R&Dopportunities in maintaining grid stability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Performance Computing Based EMT Simulation of Large PV or Hybrid PV Plants

Faults in the transmission grid have led to reduced power generation from power electronics resources that are typically not connected to the faulted transmission line. In many of the cases, partial loss of power is observed within the power electronics resources like large photovoltaic (PV) power plants. This phenomena is not captured in existing simulation models and/or simulators. High-fidelity switched system electromagnetic transient (EMT) dynamic models of PV power plants can improve the fidelity of models available for accurate analysis of the impact on PV plants during simulation of faults. However, these models are extremely computationally expensive and take a long time to simulate. Long simulation times limit the ability to use these models as larger regions are studied in EMT simulations with more power electronics resources. In this paper, numerical simulation algorithms are combined with high-performance computing techniques and applied to the high-fidelity switched system EMT model of PV plants. Using these techniques, a speed-up of up to 58x is obtained, while preserving the accuracy of the simulation at greater than 98%.

Debnath, Suman↗

A Large-Scale Hardware Experiment Demonstration of Operating High Inverter-Based Resource Power Systems With Grid-Forming Inverters

This paper presents experimental hardware results from a microgrid system as the penetration level of grid-forming (GFM) inverters increases. The experiment aims to showcase the advantages of GFM inverters in enhancing system stability and to investigate the operational challenges in systems relying entirely on inverter-based resources (IBRs). Five test scenarios are devised to progressively increase GFM inverter penetration levels: 0% (S1), 19% (S2), 37% (S3), 68% (S4), and 100% (S5). To ensure consistency, identical loading conditions and dynamic events are applied across all scenarios. The conducted tests include load step changes, output variation of grid-following (GFL) inverters during islanded mode, transition operations (such as synchronization to the grid and islanding), and rateof- change-of-frequency (ROCOF) and voltage jump tests during grid-connected mode. Key findings from the tests are summarized as follows: (1) Scenario S1 proved most challenging for load steps, and GFL variations because of insufficient GFM capacity, leaving the diesel generator unable to handle transient ridethrough; (2) Scenario S5 was the most difficult for transition operations, because the lack of a diesel generator to maintain stiff bus voltage resulted in unexpected reactive power flows during synchronization, causing the point of common coupling (PCC) breaker to trip; (3) Scenarios S4 and S5 were particularly challenging for ROCOF tests because of minimal system inertia, leading to large transients that triggered breaker trips; and (4) Scenario S4 exhibited the strongest voltage recovery capability because of the presence of the diesel generator and a higher number of GFM inverters, both of which possess the highest capacity for reactive power injection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Modeling and Analysis for Large-Scale Renewable Energy Integration

Lina He will present dynamic modeling techniques for the integration of large-scale renewable energy systems. The presentation will address the challenges associated with high renewable penetration and provide frameworks for ensuring smooth and reliable grid operations.

Dynamic modeling, large-scale renewable integratio↗

Machine learning from RANS and LES to inform coarse grid simulations

Nuclear system thermal hydraulic analysis has historically relied on computationally inexpensive 1D codes. However, such tools are unable to capture multiscale multidimensional effects in large nuclear reactor enclosures. On the other hand, simulations with higher fidelity can be too expensive for such purposes. One of the ways to reduce computational cost is to perform simulations on a coarse grid, which, unfortunately, introduces large discretization errors. In this paper, two high-to-low data-driven approaches are investigated: (1) a coarse grid turbulence model to predict eddy viscosity and (2) correction of errors in coarse grid velocity fields. The approaches aim to reduce grid- and turbulence model-induced errors in coarse grid Reynolds-averaged Navier–Stokes (RANS) simulations. Two sources of high-fidelity data, RANS and large eddy simulations (LES), are explored. To extract the eddy viscosity from the LES data, an inverse optimization problem is solved. However, the LES eddy viscosity is shown to be comparable to the RANS eddy viscosity in terms of error reduction. Therefore, the directly available RANS eddy viscosity was used to develop a coarse grid data-driven turbulence model. Additionally, error correction in velocity is used to reduce the remaining uncertainties and bring the results closer to reality. In conclusion, the performance of the frameworks is demonstrated for a scaled upper plenum of a gas-cooled reactor facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Establishing nationwide power system vulnerability index across US counties using interpretable machine learning

Power outages have become increasingly frequent, intense, and prolonged in the US due to climate change, aging electrical grids, and rising energy demand. However, largely due to the absence of granular spatiotemporal outage data, we lack data-driven evidence and analytics-based metrics to quantify power system vulnerability. This limitation has hindered the ability to effectively evaluate and address vulnerability to power outages in US communities. Here, in this work, we collected ∼179 million power outage records at 15-min intervals across 3022 US contiguous counties (96.15 % of the area) from 2014 to 2023. We developed a power system vulnerability assessment framework based on three dimensions (intensity, frequency, and duration) and applied interpretable machine learning models (XGBoost and SHAP) to compute Power System Vulnerability Index (PSVI) at the county level. Our analysis reveals a consistent increase in power system vulnerability across the US counties over the past decade. We identified 318 counties across 45 states as hotspots for high power system vulnerability, particularly in the West Coast (California and Washington), the East Coast (Florida and the Northeast area), the Great Lakes megalopolis (Chicago-Detroit metropolitan areas), and the Gulf of Mexico (Texas). Our heterogeneity analysis indicates that urban counties and those located along regional transmission boundaries tend to exhibit significantly higher vulnerability. Our results highlight the significance of the proposed PSVI for evaluating the vulnerability of communities to power outages. The findings underscore the widespread and pervasive impact of power outages across the country and offer crucial insights to support infrastructure operators, policymakers, and emergency managers in formulating policies and programs aimed at enhancing the resilience of the US power infrastructure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Sub-melt nanosecond pulsed-laser induced densification and strain-field relaxation in single-crystal diamond

Dislocations and polishing-induced defect networks in synthetic diamond introduce local strain fields and broaden Raman features, limiting performance in optical, thermal, and electronic applications. Laser annealing is emerging as a promising approach to repair surface and near-surface defects in diamond without entering the melt regime, yet surface densification, defect-state modification, and associated structural changes have not been well quantified. In this work, we show that sub-melt nanosecond pulsed-laser annealing (PLA) induces near-surface densification and defect-mediated strain relaxation in single-crystal Chemical Vapor Deposition (CVD) diamond. Single- and two-pulse PLA were applied, and structural evolution was quantified using co-registered ISO 25,178 white-light interferometry, depth-resolved Raman spectroscopy, and cross-sectional STEM with geometric phase analysis (GPA). Across a 5 × 6 grid (n = 30), responsive regions exhibit large reductions in local slope (Sdq 45–65%), developed area (Sdr 60–90%), height spread (Sp, Sz 30–65%), void volume (Vv 57–60%), and roughness amplitude (Sa, Sq 48–57%), consistent with densification of ∼4–6.5 nm. Raman profiling shows narrowing of the diamond line and improved spectral uniformity to depths of ∼2–3 μm. Given that the Raman probing depth significantly exceeds the densified layer thickness, this response is interpreted as consistent with long-range strain-field redistribution originating from the near-surface region. STEM-GPA strain maps further support this interpretation, showing smoother strain fields, suppressed hotspots, and redistribution of localized strain concentrations following PLA. These results are consistent with defect-mediated strain relaxation and densification-driven modification of the near-surface energy state. The approach provides a scalable pathway for improving near-surface structural quality in diamond relevant to electronic, photonic, and quantum applications.

Areal surface metrology (ISO 25,178)↗

Understanding the Microphysical Control and Spatial‐Temporal Variability of Warm Rain Probability Using CloudSat and MODIS Observations

Abstract By combining measurements from MODIS and the CloudSat radar, we develop a parameterization scheme to quantify the combined microphysical controls by liquid water path (LWP) and cloud droplet number concentration (CDNC) of the probability of precipitation (PoP) in marine low cloud over tropical oceans. We demonstrate that the spatial‐temporal variation of grid‐mean in‐cloud can be largely explained by the variation of the joint probability density function of LWP and CDNC in the phase space specified by the bivariate PoP (LWP and CDNC) function. Through a series of sensitivity tests guided by this understanding, we find that in the Southeastern Pacific and Atlantic the stratocumulus to cumulus transition of the is mainly due to the variation of CDNC while the annual cycle is mainly due to the variation of LWP. The results of this study provide a viable way to diagnose the root cause of warm rain problems in global climate models.

54 ENVIRONMENTAL SCIENCES↗

Li-ion and Na-ion intercalation in layered MnO 2 cathodes enabled by using bismuth as a cation pillar

Low-cost batteries based on Earth-abundant materials are needed for large-scale electrical storage for the grid. Cathodes based almost entirely on Mn oxides would reduce overall battery cost but cycling of Mn oxides is often not stable. In Li-ion cells, most polymorphs of MnO 2 undergo irreversible transformation to spinel LiMn 2 O 4 during cycling, causing capacity loss. Doping MnO 2 with Bi is known to stabilize the structure, but previous reports have relied on low-crystallinity material making it impossible to pinpoint the Bi location in the structure or its mechanism. In this work, we report a series of hydrated Bi-doped layered MnO 2 compounds and characterize their structures as a function of Bi amount. Bi is shown to reside in the material interlayer, provoking higher long-range structural order even at a low doping level of 1.3%. Doped material improves the specific capacity and stability of cycling in both Li-ion and Na-ion cells. A high level of Bi doping, 4.3%, causes loss of the interlayer crystal water in non-aqueous electrolyte, and this reduces the interlayer distance. Crystal water is shown to be beneficial in a Na-ion system, while its loss improves Li-ion cycling. This provides fundamental insight into how pillaring by a heavy, multivalent cation stabilizes layered oxides.

25 ENERGY STORAGE↗

A Hybrid Optimization and Deep Learning Algorithm for Cyber-Resilient DER Control

With the proliferation of distributed energy resources (DERs) in the distribution grid, it is a challenge to effectively control a large number of DERs resilient to the communication and security disruptions, as well as to provide the online grid services, such as voltage regulation and virtual power plant (VPP) dispatch. To this end, a hybrid feedback-based optimization algorithm along with deep learning forecasting technique is proposed to specifically address the cyber-related issues. The online decentralized feedback-based DER optimization control requires timely, accurate voltage measurement from the grid. However, in practice such information may not be received by the control center or even be corrupted. Therefore, the long short-term memory (LSTM) deep learning algorithm is employed to forecast delayed/missed/attacked messages with high accuracy. The IEEE 37-node feeder with high penetration of PV systems is used to validate the efficiency of the proposed hybrid algorithm. The results show that 1) the LSTM-forecasted lost voltage can effectively improve the performance of the DER control algorithm in the practical cyber-physical architecture; and 2) the LSTM forecasting strategy outperforms other strategies of using previous message and skipping dual parameter update.

cyber-resilient algorithm↗

An Energy Service Interface for Distributed Energy Resources

Renewable energy resources, particularly wind and solar photovoltaic, are becoming significant contributors to electric power generation. These re-sources will contribute towards achieving sustainable electric power systems. However, renewable resources will dramatically increase the demand for flexible power system operations. This paper proposes an energy service interface that will allow aggregated distributed energy resources, such as residential loads and inverter-based systems, to participate in NERC-defined smart energy reliability services. Such cyber-physical systems will increase system flexibility by ensuring match between energy supply and energy demand.Aggregation and coordinated dispatch of millions of distributed energy resources will require development of large-scale computing networks. Several smart grid interface-enabling technologies, including IEEE 2030.5, Common Smart Inverter Profile, SunSpec Modbus, and CTA 2045, are discussed. Residential loads are categorized by their static and dynamic energy characteristics to identify services in which they can participate. The business model for the energy services interface as well as probabilistic modeling for resource estimation are highlighted as future considerations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Flexibility Estimation and Control of Thermostatically Controlled Loads with Lock Time for Regulation Service

A virtual battery model is a simple and general method to quantify aggregate flexibility from thermostatically controlled loads (TCLs), enabling grid operators to effectively coordinate a large number of flexible building loads with supplyside resources in power systems. Lockout controls are designed to avoid wear and tear resulting from short-cycling of hardware. The lock on/off time could significantly affect aggregate flexibility from TCLs to provide ancillary services and may even fail control algorithms designed without considering the lock time constraints. This paper focuses on flexibility estimation and control design for TCLs with lock time constraints to provide frequency regulation service. We first investigate the potential impacts of lock time on TCLs’ aggregate flexibility and control performance. Both control-dependent and control-independent power bounds are derived, based on either previous TCL switching operations or regulation signals. While the control-dependent method provides aggregate flexibility for a given control method, the control-independent method calculates the theoretical maximum of power bounds. Two control algorithms are proposed to better distribute flexibility over time and thereby improve signal tracking performance. The proposed methods are illustrated and validated through simulations.