Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “installed capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Electrocatalytic grafting of polyvinyl chloride plastics

Polyvinyl chloride (PVC) plastics require high loadings of plasticizers and stabilizers to achieve commercially useful bulk properties. However, these non-covalent additives leach from PVC over time, resulting in the loss of their tailored functionality. This work details the electrocatalytic functionalization of PVC to covalently graft plasticizing additives directly onto the polymer backbone. Here, mechanistic insights guided the design of electrocatalysts capable of modifying C–Cl bonds of PVC under mild conditions with high selectivity while suppressing side reactions such as elimination and chain scission. Functional groups that mimic PVC plasticizers are covalently installed into the backbone of PVC to create new materials with distinct bulk properties from the original polymer. The degree of polymer grafting is easily controlled by simply changing the redox capacity that is passed during electrolysis. This strategy is employed to create chemically- and leach-resistant PVC materials by directly electrolyzing mixtures of consumer PVC products

Zackasee, Jordan L.S.↗

Mass optical storage-tape (MOST)

In today's large mainframe and supercomputer environment there exists a continuous demand for increased performance in digital storage systems. The user need for near-line storage capacity is currently doubling every four years. In addition to higher capacity, a desire exists for higher data transfer rates, and longer term database archivability, at lower, and lower cost. Each component of this quartet of demands appears to be insatiable. Magnetic tape technology presently dominates the digital mass storage markets, but the continuous growth of requirements is drawing attention to the limitations of the technology as an archival mass storage medium. The lowest cost option currently available for long term data storage is to use magnetic tape, although it is not well suited to meeting the need for many tens of years of reliable storage. Today, the majority of magnetic tape mass storage systems are based on the IBM 3480/3490 (or compatible) tape drives. These drives offer only moderate transfer rates and relatively small increments of storage, both of which create a logistics problem due to the large numbers of cartridges necessary in a typical system and the time taken to transfer data. Both higher cartridge capacity and data transfer rates are available in some helical scan magnetic tape systems; however, these command a substantially higher price, exacerbating the cost problem, and are not compatible with most installed systems or tape databases.

Oakley, William S.↗

Bulk Storage of Hydrogen

The technical aspects and economics of bulk hydrogen storage in underground pipes, lined rock caverns (LRC) and salt caverns are analyzed. Hydrogen storage in underground pipes is more economical than in geological caverns for useable amounts <20-t-H2. However, because the pipe material is a major cost factor, the capital and operating costs for this storage method do not decrease appreciably with an increase in the amount of stored H2. Unlike underground pipes, the installed capital cost of salt caverns decreases appreciably from ~$95/kg-H2 at 100 t-H2 stored to <$19/kg-H2 at 3000 t-H2 stored. Over the same scale, the annual storage cost decreases from ~$17/kg-H2 to ~$3/kg-H2. Like salt caverns, the installed capital cost of lined rock caverns decreases from ~$160/kg-H2 at 100 t-H2 stored to <$44/kg-H2 at 3000 t-H2 stored. Storing >750-t useable H2 requires multiple caverns. The cost of salt caverns scales more favorably with size because the salt caverns are larger than lined rock caverns and need to be added at a slower rate as the storage capacity is increased.

Bulk storage of hydrogen↗

Thermal Modeling and Limitations for Power Electronics Embedded in Medium-Voltage Cables

As next-generation energy technologies gain traction and power demand increases, the existing electrical infrastructure faces significant stress, prompting innovative solutions to enhance the grid's capacity and lifespan. This work explores the possibility of embedding medium-voltage (MV) power electronics directly inline with the cable, and the resulting thermal challenges. Since the majority of power distribution cables installed in the U.S. are passively cooled, the work focuses primarily on passive cooling, with an emphasis on the limitations of axial heat spreading within the cable. To date, literature on axial spreading of high incident heat loads on cables and cable environments is limited, typically reporting cases with <10 W of incident heat load. This work will explore the considerations, limits, and tradeoffs of cable-embedded heat loads significantly larger than the cable losses. Both external and internal effects are modeled analytically in nondimensional terms via a Biot number analysis, allowing fundamental limits and tradeoffs to be derived. The work culminates in the design and experimental validation of a cable-embedded thermal system capable of passively dissipating 300 W of heat from a coaxial SiC mosfet switch module over a length of 20 cm, thus validating the possibility of MV cable-embedded power electronics from a thermal standpoint.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Flexible Metal-Fabric Radiators

Flexible metal-fabric radiators have been considered as alternative means of dissipating excess heat from spacecraft and space suits. The radiators also may be useful in such special terrestrial applications as rejecting heat from space-suit-like protective suits worn in hot work environments. In addition to flexibility and consequent ease of deployment and installation on objects of varying sizes and shapes, the main advantages of these radiators over conventional rigid radiators are that they weigh less and occupy less volume for a given amount of cooling capacity. A radiator of this type includes conventional stainless-steel tubes carrying a coolant fluid. The main radiating component consists of a fabric of interwoven aluminum-foil strips bonded to the tubes by use of a proprietary process. The strip/tube bonds are strong and highly thermally conductive. Coolant is fed to and from the tubes via flexible stainless-steel manifolds designed to accommodate flexing of, and minimize bending forces on, the fabric. The manifolds are sized to minimize pressure drops and distribute the flow of coolant evenly to all the tubes. The tubes and manifolds are configured in two independent flow loops for operational flexibility and protective redundancy.

Cross, Cynthia↗

Statistical Characterization of 18650-Format Lithium-Ion Cell Thermal Runaway Energy Distributions

Effective thermal management systems, designed to handle the impacts of thermal runaway (TR) and to prevent cell-to-cell propagation, are key to safe operation of lithium-ion (Li-ion) battery assemblies. Critical factors for optimizing these systems include the total energy released during a single cell TR event and the fraction of the total energy that is released through the cell casing vs. through the ejecta material. A unique calorimeter was utilized to examine the TR behavior of a statistically significant number of 18650-format Li-ion cells with varying manufacturers, chemistries, and capacities. The calorimeter was designed to contain the TR energy in a format conducive to discerning the fractions of energy released through the cell casing vs. through the ejecta material. Other benefits of this calorimeter included the ability to rapidly test of large quantities of cells and the intentional minimization of secondary combustion effects. High energy (270 Wh/kg) and moderate energy (200 Wh/kg) 18650 cells were tested. Some of the cells had an imbedded short circuit (ISC) device installed to aid in the examination of TR mechanisms under more realistic conditions. Other variations included cells with bottom vent (BV) features and cells with thin casings (0.22 1/4m). After combining the data gathered with the calorimeter, a statistical approach was used to examine the probability of certain TR behavior, and the associated energy distributions, as a function of capacity, venting features, cell casing thickness and temperature.

Thermal Runaway Energy Distribution↗

Upgrading the LANSCE accelerator with a SNS RF-driven H− ion source

The LANSCE accelerator is currently powered by a filament-driven, biased converter-type H− ion source that operates at 10%, the highest plasma duty factor for this type of source, using only ∼2.2 SCCM of H2. The ion source needs to be replaced every 4 weeks, which takes up to 4 days. The measured negative beam current of 12–16 mA falls below the desired 24 mA acceptance of the LANCSE accelerator. The SNS (Spallation Neutron Source) RF-driven, H− ion source injects ∼50 mA of H− beam into the SNS accelerator at 60 Hz with a 6% duty factor and an availability of >99.5% but requires ∼30 SCCM of H2. Up to 7 A h of H− have been produced during the 14-weeks-long source service cycles, which is unprecedented for small emittance, high-current, pulsed H− ion sources. The emittance of the SNS source is slightly smaller than the emittance of the LANSCE source. The SNS source also features unrivaled low Cs consumption and can be installed and started up in <12 h. LANSCE and SNS are working toward the use of SNS H− ion sources on the LANSCE accelerator because they could (a) fill the LANSCE accelerator to its capacity, (b) decrease the source replacement time by a factor of up to 7, and (c) increase source lifetime by a factor of about 4. This paper discusses some of the challenges that emerge when trying to match a different H− source into an existing injector with significantly different characteristics and operating regimes.

Stockli, Martin P.↗

A Supply Chain Road Map for Offshore Wind Energy in the United States

"A Supply Chain Road Map for Offshore Wind Energy in the United States" identifies pathways to developing a domestic offshore wind supply chain that can manufacture and deploy the major components needed to set the United States on a pathway to installing 30 GW of offshore wind by 2030 and 110 GW by 2050. The report estimates that this supply chain could require an investment of at least $\$$22.7 billion this decade to meet an annual demand for components, ports, and vessels in 2030. Although this is a considerable investment, it could allow the industry to install around $\$$100 billion worth of offshore wind this decade by reducing risk of delays due to global supply chain bottlenecks and creating a robust network of assets that will continue to be effective well beyond 2030. The United States would need at least 34 manufacturing facilities employing 10,000 workers, 39,000 jobs in the supporting supply chain, 10 marshaling ports, 4-6 dedicated wind turbine installation vessels, 4-6 dedicated heavy-lift vessels, and 4-8 U.S.-flagged specialized feeder barges to come online this decade to support an average annual deployment of 4-6 gigawatts offshore wind capacity per year. This supply chain could be developed in 6-9 years, but would require near-term decision making and efficient permitting and planning to strategically develop these resources by 2030. Additional investment and expansion would be required in the 2030s as the sector expands into new regions (such as the Gulf of Mexico) and new technologies (such as larger wind turbines and floating wind energy projects). Furthermore, the planning process needs to meaningfully engage with communities that will be impacted by supply chain expansion to achieve just outcomes and maximize benefits to these stakeholders, which will result in a more equitable and sustainable supply chain. While U.S. offshore wind has made significant progress in recent years, remaining supply chain challenges include uncertainty surrounding deployment and procurement timelines; a lack of port and vessel infrastructure; and limitations in the available workforce, supporting supplier networks, and energy justice best practices. However, many of these problems can be addressed through improved communication between key stakeholder groups, support from federal and state governments, and forward-thinking designs of supply chain assets to accommodate future technology changes for fixed-bottom and floating offshore wind. Although it is a significant task, developing these domestic capabilities represents a once-in-a-generation opportunity to contribute to a decarbonized energy future and also create massive economic benefits that are distributed throughout the country.

17 WIND ENERGY↗

Introduction to Voigt's wind power plant

The design and operation of a 100 kilowatt wind driven generator are reported. Its high speed three-bladed turbine operates at a height of 50 meters. Blades are rigidly connected to the hub and turbine revolutions change linearly with wind velocity, maintaining a constant speed ratio of blade tip velocity to wind velocity over the full predetermined wind range. Three generators installed in the gondola generate either dc or ac current. Based on local wind conditions, the device has a maximum output of 720 kilowatts at a wind velocity of 16 meters per second. Total electrical capacity is 750 kilowatts, and power output per year is 2,135,000 kilowatt/hours.

Tompkin, J.↗

Interface standardization

Central-station applications create a large and attractive market for photovoltaics in the near future. However, some significant barriers lie between the industry of today and realization of that market. Manufacturing capacity and price are two principal impediments. The Utilities, which are the future system owners, are gaining experience with central-station PV power through the Sacramento Municipal Utility District, Hesperia and similar small central-station installations. SMUD has recognized that competition must be maintained to help reduce prices. So little standardization exists that the cost is driven upward to redefine mechanical and electrical interfaces for each vendor. New structues are required for each vendor and nonoptimum field geometries result from attempts to include more than one vendor in an array field. Standards at some hardware level are required.

Spencer, R.↗

Development and Preliminary Analysis of a U.S. Geothermal Heat Pump Installation Database

This paper seeks to addresses the significant gap in the literature regarding the installation and adoption of geothermal heat pump (GHP) systems in the United States. While the "2021 U.S. Geothermal Power Production and District Heating Market Report" published by the National Renewable Energy Laboratory (NREL) focused on direct-use geothermal district heating systems, it did not include an analysis of GHP installations (Robins et al. 2021). To bridge this gap, NREL has compiled a novel database currently containing 70,470 records of GHP installations, primarily sourced from state well permits and small-scale studies. Our methodology emphasizes the collection, cleaning, and standardization of data, addressing challenges such as inconsistent reporting formats and privacy concerns. Despite limitations in data on capacity, costs, and performance, our preliminary geospatial analysis reveals insights into the distribution of GHP systems across urban and rural areas and climate zones. The paper highlights the importance of publicly accessible data for advancing GHP technology adoption with a discussion of existing data sources and their limitations, advocating for improved collaboration between NREL and industry stakeholders.

data collection↗

Grid Value Analysis of Medium-Voltage Back-to-Back Converter on DER Hosting Enhancement

This paper presents an analysis of the value that can be realized by medium-voltage back-to-back (MVB2B) converters in terms of the increased utilization rate of distributed energy resources (DERs) and the improvement in operational conditions. A systematic, transferrable, and scalable methodology has been designed to analyze and quantify the increased DER value from three perspectives: 1) curtailment reduction of the DER generation, 2) size reduction of the energy storage needed to otherwise realize DER hosting levels, and 3) hosting capacity improvement of the DERs compared to the base distribution circuit capability. In the case study, the proposed methodology is applied to two utility distribution systems for analysis and quantification of the grid value of the MVB2B converter, installed in the distribution circuit, and provided to the solar photovoltaic (PV) DERs. Here, the analysis results demonstrate that the MVB2B converter can deliver significant value to the PV hosting enhancement of two adjacent distribution systems when they are connected by the MVB2B converter. Based on this case study, this paper analyzes and summarizes the approximate realized grid value of the MVB2B converter for distribution systems dominated by different shares of customer classes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Oglala Omaste 2020

Oglala Lakota Housing Authority (OLHA), the tribally designated housing entity of the Oglala Sioux Tribe, installed solar photovoltaic (PV) systems on six tribal buildings, including the Oglala Lakota Housing Authority administration building, four Veterans Affairs Supportive Housing (HUD-VASH) homes, and one Rural Innovation Fund (RIF) home. Combined, the total solar PV capacity of this project is approximately 54 kilowatts-direct current (kW-DC), offsetting an estimated 74,176 kilowatt-hours (kWh) per year and saving OLHA and tenants of the tribally owned residences approximately $\$$8,226 annually. The lifetime savings of the project is estimated to be $\$$380,344. The project aligns with energy goals of OLHA and the Oglala Sioux Tribe to reduce energy costs for low rent tenants and to reduce our carbon footprint; both of which are in line with Lakota values.

14 SOLAR ENERGY↗

Techno-Economic Analysis of a Concentrating Solar Power Plant Using Redox-Active Metal Oxides as Heat Transfer Fluid and Storage Media

We present results for a one-dimensional quasi-steady-state thermodynamic model developed for a 111.7 MW e concentrating solar power (CSP) system using a redox-active metal oxide as the heat storage media and heat transfer agent integrated with a combined cycle air Brayton power block. In the energy charging and discharging processes, the metal oxide CaAl 0.2 Mn 0.8 O 2.9-δ (CAM28) undergoes a reversible, high temperature redox cycle including an endothermic oxygen-releasing reaction and exothermic oxygen-incorporation reaction. Concentrated solar radiation heats the redox-active oxide particles under partial vacuum to drive the reduction extent deeper for increased energy density at a fixed temperature, thereby increasing storage capacity while limiting the required on sun temperature. Direct counter-current contact of the reduced particles with compressed air from the Brayton compressor releases stored chemical and sensible energy, heating the air to 1,200°C at the turbine inlet while cooling and reoxidizing the particles. The cool oxidized particles recirculate through the solar receiver subsystem for another cycle of heating and reduction (oxygen release). We applied the techno-economic model to 1) size components, 2) examine intraday operation with varying solar insolation, 3) estimate annual performance characteristics over a simulated year, 4) estimate the levelized cost of electricity (LCOE), and 5) perform sensitivity analyses to evaluate factors that affect performance and cost. Simulations use hourly solar radiation data from Barstow, California to assess the performance of a 111.7 MW e system with solar multiples (SMs) varying from 1.2 to 2.4 and storage capacities of 6–14 h. The baseline system with 6 h storage and SM of 1.8 has a capacity factor of 54.2%, an increase from 32.3% capacity factor with no storage, and an average annual energy efficiency of 20.6%. Calculations show a system with an output of 710 GWh e net electricity per year, 12 h storage, and SM of 2.4 to have an installed cost of $329 million, and an LCOE of 5.98 ¢/kWh e . This value meets the U.S. Department of Energy’s SunShot 2020 target of 6.0 ¢/kWh e ( U. S Department of Energy, 2012 ), but falls just shy of the 5.0 ¢/kWh e 2030 CSP target for dispatchable electricity ( U. S Department of Energy, 2017 ). The cost and performance results are minimally sensitive to most design parameters. However, a one-point change in the weighted annual cost of capital from 8 to 7% (better understood as a 12.5% change) translates directly to an 11% decrease (0.66 ¢/kWhe) in the LCOE.

Gorman, Brandon T.↗

Front End Engineering Design Report

Energy storage is becoming an increasingly important component on modern power grids to ensure sufficient balancing capability for intermittent renewable power generations is available to maintain system reliability. Although energy storage has traditionally been provided by pumped storage hydroelectric systems, it is not possible to install these at every location and they can be expensive to construct. Lithium Ion batteries are increasingly being used to carry out energy storage grid services, however these can be expensive when specified over a few hours of capacity. An alternative way to store substantial energy is to use thermal energy storage (TES). This has been deployed on concentrated solar units using molten nitrate salts as a storage media. Again, the cost of the material can be prohibitive, thus lower cost alternative materials are being actively sought, such as sand, rocks and concrete. This project investigates the potential for Concrete Thermal Energy Storage (CTES) when used to directly store thermal energy from a thermal plant source. This report represents the initial Front-End Engineering Design (FEED) deliverables that are submitted for the Hazard and Operability (HAZOP) safety review for process validation.

25 ENERGY STORAGE↗

CTES Pilot Plant Detailed Design Report

Energy storage is becoming an increasingly important component on modern power grids to ensure sufficient balancing capability for intermittent renewable power generations is available to maintain system reliability. Although energy storage has traditionally been provided by pumped storage hydroelectric systems, it is not possible to install these at every location and they can be expensive to construct. Lithium Ion batteries are increasingly being used to carry out energy storage grid services, however these can be expensive when specified over a few hours of capacity. An alternative way to store substantial energy is to use thermal energy storage (TES). This has been deployed on concentrated solar units using molten nitrate salts as a storage media. Again, the cost of the material can be prohibitive, thus lower cost alternative materials are being actively sought, such as sand, rocks and concrete. This project investigates the potential for Concrete Thermal Energy Storage (CTES) when used to directly store thermal energy from a thermal plant source. This report represents the Detailed Design phase deliverables comprising of the process, mechanical, electrical, piping along with control and instrumentation documents. Civil and structural deliverables are included on a preliminary basis due to outstanding site investigation activities. CTES block transportation testing results and the pilot plant testing plan is also included in this report.

25 ENERGY STORAGE↗

Sorbent Based Post-Combustion CO 2 Slipstream Testing

TDA Research, Inc. has developed a low-cost sorbent (alkalized alumina) based technology for post-combustion CO 2 capture. The sorbent runs in an isothermal process for adsorption and regeneration. Neither temperature swing nor pressure swing is needed. TDA designed a system which operated 10 fixed beds to simulate a moving bed process. The flow pattern was optimized to minimize the steam usage for regeneration. An excellent sorbent (Batch 1) was also developed with collaboration with our partner. The sorbent degraded after long term operation. We developed a reprocessing procedure, which can be conducted in situ, to restore the sorbent capture capacity as the fresh sorbent after running for about 1250 hours. The reprocessing extended the sorbent longevity significantly. TDA designed a pilot unit (40’ x 32’ x 11.5’), processing flue gas equivalent to 0.5 MW of power generation. It had 10 beds and each bed could hold 1.75 m 3 of sorbent. We worked with Springs Fabrication, Inc. to complete the construction of the pilot unit. It was then shipped and installed at NCCC. The pilot unit was kept running in 24-hour mode when the flue gas and steam were available. It could run automatically without operator on site. Parametric and long-term (2 months) tests were carried out successfully. The results showed that TDA’s process can achieve 90% capture and 95% CO 2 purity for both coal and NG flue gases. For coal flue gas, the system reached performance target when processing up to 0.62 MW flue gas, 24% higher than the design capacity. Thus, capital cost could be saved on the reactors and sorbent. The strip air flow was designed to be 0.25 of that of the flue gas. The test data showed the strip/flue ratio can be reduced to as little as 0.18, which saves the power consumption for the strip air blower. The pressure drop was found to be lower than what the empirical equation calculated. The sorbent still had 91.7% of original capacity after 3-month test. With the data from the pilot test, we updated the TEA. For a 550-MW e supercritical coal fired power plant with CO 2 capture, the capture cost for TDA’s process is $34.9/tonne CO 2 captured, which meets DOE’s goal of $40/tonne and is 17.1% less than the DOE baseline Case 12. Therefore, TDA’s process has a good potential for commercialization.

01 COAL, LIGNITE, AND PEAT↗

Space shuttle Mission Control Center upgrade

The Mission Control Center (MCC) is the facility that provides centralization of all mission operations in support of the shuttle from liftoff through landing. This facility serves as the focal point for real time flight control operations supporting the shuttle, spacelab, and selected payload systems. MCC upgrade accomplishments are as follows: replaced 5 mainframe computers and the associated input/output data interfaces; developed and installed a distributed data system with 81 workstations, 5 LANs, data drivers, and a fiber optic distribution subsystem; developed over 1.5 million lines of code to support new distributed system; developed new digital voice system which provides the MCC capacity to handle th Shuttle programs demands and growth potential to handle Space Station; replaced failing digital TV equipment with digital generation equipment; replaced obsolete center screen projector; and provided the platform for the multiprogram control center.

Duffin, Pat↗