Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Final Report on Developing Microstructure-Property Correlation in Reactor Materials using in situ High-Energy X-rays

This report provides a summary of research activities on understanding microstructure – property correlation in reactor materials using in situ high-energy X-rays. The report is a Level 2 deliverable in FY16 (M2CA-13-IL-AN_-0403-0111), under the Work Package CA-13-IL-AN_- 0403-01, “Microstructure-Property Correlation in Reactor Materials using in situ High Energy Xrays”, as part of the DOE-NE NEET Program. The objective of this project is to demonstrate the application of in situ high energy X-ray measurements of nuclear reactor materials under thermal-mechanical loading, to understand their microstructure-property relationships. The gained knowledge is expected to enable accurate predictions of mechanical performance of these materials subjected to extreme environments, and to further facilitate development of advanced reactor materials. The report provides detailed description of the in situ X-ray Radiated Materials (iRadMat) apparatus designed to interface with a servo-hydraulic load frame at beamline 1-ID at the Advanced Photon Source. This new capability allows in situ studies of radioactive specimens subject to thermal-mechanical loading using a suite of high-energy X-ray scattering and imaging techniques. We conducted several case studies using the iRadMat to obtain a better understanding of deformation and fracture mechanisms of irradiated materials. In situ X-ray measurements on neutron-irradiated pure metal and model alloy and several representative reactor materials, e.g. pure Fe, Fe-9Cr model alloy, 316 SS, HT-UPS, and duplex cast austenitic stainless steels (CASS) CF-8 were performed under tensile loading at temperatures of 20-400°C in vacuum. A combination of wide-angle X-ray scattering (WAXS), small-angle X-ray scattering (SAXS), and imaging techniques were utilized to interrogate microstructure at different length scales in real time while the specimen was subject to thermal-mechanical loading. In addition, in situ X-ray studies were complemented and benchmarked by ex situ characterization using advanced electron microscopy, atom probe tomography (APT) and micro/nano-indentation. The report presented in situ tensile test results on neutron-irradiated pure Fe, Fe-9Cr model alloy, 316 SS and CASS CF-8. These in situ experiments demonstrate the broad applications of the new capability in understanding several outstanding issues related to irradiated materials.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Application of digital image processing techniques and information systems to water quality monitoring of Lake Tahoe

The Tahoe basin occupies over 500 square miles of territory located in a graben straddling the boundary between California and Nevada. Lake Tahoe contains 126 million acre-feet of water. Since the 1950's the basin has experienced an ever increasing demand for land development at the expense of the natural watershed. Discharge of sediment to the lake has greatly increased owing to accelerated human interference, and alterations to the natural drainage patterns are evident in some areas. In connection with an investigation of the utility of a comprehensive system that takes into account the causes as well as the effects of lake eutrophication, it has been attempted to construct an integrated and workable data base, comprised of currently available data sources for the Lake Tahoe region. Attention is given to the image based information system (IBIS), the construction of the Lake Tahoe basin data base, and the application of the IBIS concept to the Lake Tahoe basin.

Smith, A. Y.↗

Observation of nanoparticle coalescence during core-shell metallic nanowire growth in colloids via nanoscale imaging

The surface morphology and shape of crystalline nanowires significantly influence their functional properties, including phonon transport, electrocatalytic performance, to name but a few. However, the kinetic pathways driving these morphological changes remain underexplored due to challenges in real-space and real-time imaging at single-particle and atomic resolutions. This study investigates the dynamics of shell (Au, Pd, Pt, Fe, Cu, Ni) deposition on AuAg alloy seed nanowires during core-shell formation. By using chiral/non-chiral seed nanowires, advanced imaging techniques, including liquid-phase transmission electron microscopy (LPTEM), cryogenic TEM, and three-dimensional electron tomography, a three-step deposition process is revealed: heterogeneous nucleation, nanoparticle attachment, and coalescence. It is found that colloidal Ostwald ripening, metal reactivity, and deposition amount modulate nanoparticle size and surface roughness, shaping final morphologies. Noble metal nanoparticles (Au, Ag, Pd, Pt) coalesce with seed nanowire along the 〈111〉 direction, distinct from that of other metals. These findings are consistent across different metals, including Ru, Cu, Fe, and Ni, highlighting the hypothesis of these processes in nanowire formation. These findings enhance traditional crystallographic theories and provide a framework for designing nanowire morphology. Additionally, our imaging techniques may be applied to investigate phenomena like electrodeposition, dendrite growth in batteries, and membrane deformation.

Yang, Dahai↗

Characterization of Oscillation Modes in Levitated Droplets Using Image and Non-Image Based Techniques

The dynamics of levitated liquid droplets can be used to measure their thermophysical properties by correlating the frequencies at which normal modes of oscillation most strongly resonate when subject to an external oscillatory force. In two preliminary works, it was shown via electrostatic levitation and processing of various metals and alloys that 1) the resonance of the first principal mode of oscillation (mode n = 2) can be used to accurately measure surface tension and 2) that so-called ‘higher-order resonance’ of n = 3 is observable at a predictable frequency. It was also shown, in the context of future space-based experimentation on the Electrostatic Levitation Furnace (ELF), a setup on the International Space Station (ISS) operated by Japan Aerospace Exploration Agency (JAXA), that while the shadow array method in which droplet behavior is visualized would be challenging to identify the n = 3 resonance, the normal mode n = 4 was predicted to be more easily identifiable. In this short communication, experimental evidence of the first three principal modes of oscillation is provided using molten samples of Tin and Indium and it is subsequently shown that, as predicted, an “image-less” approach can be used to identify both n = 2 and n = 4 resonances in levitated liquid droplets. This suggests that the shadow array method may be satisfactorily used to obtain a self-consistent benchmark of thermophysical properties by comparing results from two successive even-mode natural frequencies.

Nevin Brosius↗

A limited-angle intrafraction verification (LIVE) system for radiation therapy

Purpose: Currently, no 3D or 4D volumetric x-ray imaging techniques are available for intrafraction verification of target position during actual treatment delivery or in-between treatment beams, which is critical for stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) treatments. This study aims to develop a limited-angle intrafraction verification (LIVE) system to use prior information, deformation models, and limited angle kV-MV projections to verify target position intrafractionally. Methods: The LIVE system acquires limited-angle kV projections simultaneously during arc treatment delivery or in-between static 3D/IMRT treatment beams as the gantry moves from one beam to the next. Orthogonal limited-angle MV projections are acquired from the beam's eye view (BEV) exit fluence of arc treatment beam or in-between static beams to provide additional anatomical information. MV projections are converted to kV projections using a linear conversion function. Patient prior planning CT at one phase is used as the prior information, and the on-board patient volume is considered as a deformation of the prior images. The deformation field is solved using the data fidelity constraint, a breathing motion model extracted from the planning 4D-CT based on principal component analysis (PCA) and a free-form deformation (FD) model. LIVE was evaluated using a 4D digital extended cardiac torso phantom (XCAT) and a CIRS 008A dynamic thoracic phantom. In the XCAT study, patient breathing pattern and tumor size changes were simulated from CT to treatment position. In the CIRS phantom study, the artificial target in the lung region experienced both size change and position shift from CT to treatment position. Varian Truebeam research mode was used to acquire kV and MV projections simultaneously during the delivery of a dynamic conformal arc plan. The reconstruction accuracy was evaluated by calculating the 3D volume percentage difference (VPD) and the center of mass (COM) difference of the tumor in the true on-board images and reconstructed images. Results: In both simulation and phantom studies, LIVE achieved substantially better reconstruction accuracy than reconstruction using PCA or FD deformation model alone. In the XCAT study, the average VPD and COM differences among different patient scenarios for LIVE system using orthogonal 30° scan angles were 4.3% and 0.3 mm when using kV+BEV MV. Reducing scan angle to 15° increased the average VPD and COM differences to 15.1% and 1.7 mm. In the CIRS phantom study, the VPD and COM differences for the LIVE system using orthogonal 30° scan angles were 6.4% and 1.4 mm. Reducing scan angle to 15° increased the VPD and COM differences to 51.9% and 3.8 mm. Conclusions: The LIVE system has the potential to substantially improve intrafraction target localization accuracy by providing volumetric verification of tumor position simultaneously during arc treatment delivery or in-between static treatment beams. With this improvement, LIVE opens up a new avenue for margin reduction and dose escalation in both fractionated treatments and SRS and SBRT treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Realizing in-plane surface diffraction by x-ray multiple-beam diffraction with large incidence angle

Based on rigorous dynamical-theory calculations, we demonstrate in this paper the principle of an x-ray multiple-beam diffraction (MBD) scheme that overcomes the long-lasting difficulties of high-resolution in-plane diffraction from crystal surfaces. This scheme only utilizes symmetric reflection geometry with large incident angles but activates the out-of-plane and in-plane diffraction processes simultaneously and separately in the continuous MBD planes. The in-plane diffraction is realized by detoured MBD, where the intermediate diffracted waves propagate parallel to the surface, which corresponds to an absolute Bragg surface diffraction configuration that is extremely sensitive to surface structures. Finally, a series of MBD diffraction and imaging techniques may be developed from this principle to study surface/interface (misfit) strains, lateral nanostructures, and phase transitions of a wide range of (pseudo)cubic crystal structures, including ultrathin epitaxial films and multilayers, quantum dots, strain-engineered semiconductor or (multi)ferroic materials, etc.

36 MATERIALS SCIENCE↗

Pressure-induced velocity softening in natural orthopyroxene at mantle temperature

In this study, we have measured the compressional and shear wave velocities of (Mg 1.77 Fe 0.22 Ca 0.01 )Si 2 O 6 natural orthopyroxene up to 13.5 GPa and 873 K using ultrasonic interferometry in conjunction with in situ synchrotron X-ray diffraction and imaging techniques. Previous acoustic experiments on orthoenstatite (OEn) MgSiO 3 indicated that both compressional and shear velocities (V P and V S ) of OEn undergo continuous velocity softening above 9 GPa at room temperature, which has been attributed to the phase transition from OEn to the metastable, high-pressure clinoenstatite HPCEn2. For the first time, our results suggest that pressure-induced velocity softening can occur in natural orthopyroxene at high-temperature conditions relevant to the Earth's cold subduction zones. As a result, estimates of the impedance and velocity contrasts between orthopyroxene (Opx) and high-pressure clinopyroxene (HPCpx) have been calculated, and the possibility of this phase transformation being a plausible candidate for seismic X-discontinuities at depth around 250–350 km is re-evaluated.

36 MATERIALS SCIENCE↗

Comparison of patient specific dose metrics between chest radiography, tomosynthesis, and CT for adult patients of wide ranging body habitus

Purpose: Given the radiation concerns inherent to the x-ray modalities, accurately estimating the radiation doses that patients receive during different imaging modalities is crucial. This study estimated organ doses, effective doses, and risk indices for the three clinical chest x-ray imaging techniques (chest radiography, tomosynthesis, and CT) using 59 anatomically variable voxelized phantoms and Monte Carlo simulation methods. Methods: A total of 59 computational anthropomorphic male and female extended cardiac-torso (XCAT) adult phantoms were used in this study. Organ doses and effective doses were estimated for a clinical radiography system with the capability of conducting chest radiography and tomosynthesis (Definium 8000, VolumeRAD, GE Healthcare) and a clinical CT system (LightSpeed VCT, GE Healthcare). A Monte Carlo dose simulation program (PENELOPE, version 2006, Universitat de Barcelona, Spain) was used to mimic these two clinical systems. The Duke University (Durham, NC) technique charts were used to determine the clinical techniques for the radiographic modalities. An exponential relationship between CTDI{sub vol} and patient diameter was used to determine the absolute dose values for CT. The simulations of the two clinical systems compute organ and tissue doses, which were then used to calculate effective dose and risk index. The calculation of the two dose metrics used the tissue weighting factors from ICRP Publication 103 and BEIR VII report. Results: The average effective dose of the chest posteroanterior examination was found to be 0.04 mSv, which was 1.3% that of the chest CT examination. The average effective dose of the chest tomosynthesis examination was found to be about ten times that of the chest posteroanterior examination and about 12% that of the chest CT examination. With increasing patient average chest diameter, both the effective dose and risk index for CT increased considerably in an exponential fashion, while these two dose metrics only increased slightly for radiographic modalities and for chest tomosynthesis. Effective and organ doses normalized to mAs all illustrated an exponential decrease with increasing patient size. As a surface organ, breast doses had less correlation with body size than that of lungs or liver. Conclusions: Patient body size has a much greater impact on radiation dose of chest CT examinations than chest radiography and tomosynthesis. The size of a patient should be considered when choosing the best thoracic imaging modality.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparative Studies of Optoelectrical Properties of Prominent PV Materials: Halide Perovskite, CdTe, and GaAs

We compare three representative high performance PV materials: halide perovskite MAPbI3, CdTe, and GaAs, in terms of photoluminescence (PL) efficiency, PL lineshape, carrier diffusion, and surface recombination and passivation, over multiple orders of photo-excitation density or carrier density appropriate for different applications. An analytic model is used to describe the excitation density dependence of PL intensity and extract the internal PL efficiency and multiple pertinent recombination parameters. A PL imaging technique is used to obtain carrier diffusion length without using a PL quencher, thus, free of unintended influence beyond pure diffusion. Our results show that perovskite samples tend to exhibit lower Shockley-Read-Hall (SRH) recombination rate in both bulk and surface, thus higher PL efficiency than the inorganic counterparts, particularly under low excitation density, even with no or preliminary surface passivation. PL lineshape and diffusion analysis indicate that there is considerable structural disordering in the perovskite materials, and thus photo-generated carriers are not in global thermal equilibrium, which in turn suppresses the nonradiative recombination. This study suggests that relatively low point-defect density, less detrimental surface recombination, and moderate structural disordering contribute to the high PV efficiency in the perovskite. This comparative photovoltaics study provides more insights into the fundamental material science and the search for optimal device designs by learning from different technologies.

14 SOLAR ENERGY↗

Novel Applications of the Multi-Beam SEM [Abstract Only]

The Zeiss Multi-Beam Scanning Electron Microscope (MultiSEM) was used to image a wide array samples using non-standard operating conditions. The ability of this new, high-throughput imaging technique to produce high-quality images was assessed during this one year LDRD. In addition to exploring new imaging conditions, sample preparation techniques, coupled with theoretical simulations, were explored to optimize the MultiSEM images. To obtain details about the devices imaged, as well as the experimental details, please refer to the classified report from the project manager, Bradley Gabel, or the Cyber IA lead, Justin Ford.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Innovative biomagnetic imaging sensors for breast cancer: A model-based study

Breast cancer is a serious potential health problem for all women and is the second leading cause of cancer deaths in the United States. The current screening procedures and imaging techniques, including x-ray mammography, clinical biopsy, ultrasound imaging, and magnetic resonance imaging, provide only 73% accuracy in detecting breast cancer. This gives the impetus to explore alternate techniques for imaging the breast and detecting early stage tumors. Among the complementary methods, the noninvasive biomagnetic breast imaging is attractive and promising, because both ionizing radiation and breast compressions that the prevalent x-ray mammography suffers from are avoided. It furthermore offers very high contrast because of the significant electromagnetic properties' differences between the cancerous, benign, and normal breast tissues. In this paper, a hybrid and accurate modeling tool for biomagnetic breast imaging is developed, which couples the electromagnetic and ultrasonic energies, and initial validations between the model predication and experimental findings are conducted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Urinary diversions: a primer of the surgical techniques and imaging findings

Objective: The article attempts to describe the indications, classification, and surgical anatomy of the commonly performed urinary diversion procedures, followed by the imaging protocol and radiological appearances of the normal postoperative anatomy and complications related to these procedures. Contents: Diversion procedures are used to reroute urine after cystectomy and in patients with refractory neurogenic or outlet obstruction of the urinary bladder. Broadly, these can be classified as continent and incontinent diversions. Patients with urinary diversions frequently undergo radiological investigations for the detection of complications. Commonly, a loopogram or pouchogram is performed few weeks after the surgery to look for leak, whereas CT or MRI is used for long-term follow-up. Postoperative complications can be early (within 30 days of the surgery) or delayed and include leaks, collections, strictures, calculi, parastomal hernia, small bowel obstruction, and oncologic recurrence. Conclusion: A variety of urinary diversion procedures are commonly performed and interpretation of the postsurgical anatomy can be overwhelming for the general radiologist. This article provides a basic understanding of the normal anatomy as well as a thorough discussion on the imaging protocol and radiological appearances of the potential complications associated with these procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

THE INFORMATION CONTENT IN ANALYTIC SPOT MODELS OF BROADBAND PRECISION LIGHT CURVES

We present the results of numerical experiments to assess degeneracies in light curve models of starspots. Using synthetic light curves generated with the Cheetah starspot modeling code, we explore the extent to which photometric light curves constrain spot model parameters, including spot latitudes and stellar inclination. We also investigate the effects of spot parameters and differential rotation on one's ability to correctly recover rotation periods and differential rotation in the Kepler light curves. We confirm that in the absence of additional constraints on the stellar inclination, such as spectroscopic measurements of vsin i or occultations of starspots by planetary transits, the spot latitude and stellar inclination are difficult to determine uniquely from the photometry alone. We find that for models with no differential rotation, spots that appear on opposite hemispheres of the star may cause one to interpret the rotation period to be half of the true period. When differential rotation is included, the changing longitude separation between spots breaks the symmetry of the hemispheres and the correct rotation period is more likely to be found. The dominant period found via periodogram analysis is typically that of the largest spot. Even when multiple spots with periods representative of the star's differential rotation exist, if one spot dominates the light curve the signal of differential rotation may not be detectable from the periodogram alone. Starspot modeling is applicable to stars with a wider range of rotation rates than other surface imaging techniques (such as Doppler imaging), allows subtle signatures of differential rotation to be measured, and may provide valuable information on the distribution of stellar spots. However, given the inherent degeneracies and uncertainty present in starspot models, caution should be exercised in their interpretation.

79 ASTRONOMY AND ASTROPHYSICS↗

Approaches to reducing photon dose calculation errors near metal implants

Purpose: Dose calculation errors near metal implants are caused by limitations of the dose calculation algorithm in modeling tissue/metal interface effects as well as density assignment errors caused by imaging artifacts. The purpose of this study was to investigate two strategies for reducing dose calculation errors near metal implants: implementation of metal-based energy deposition kernels in the convolution/superposition (C/S) dose calculation method and use of metal artifact reduction methods for computed tomography (CT) imaging. Methods: Both error reduction strategies were investigated using a simple geometric slab phantom with a rectangular metal insert (composed of titanium or Cerrobend), as well as two anthropomorphic phantoms (one with spinal hardware and one with dental fillings), designed to mimic relevant clinical scenarios. To assess the dosimetric impact of metal kernels, the authors implemented titanium and silver kernels in a commercial collapsed cone C/S algorithm. To assess the impact of CT metal artifact reduction methods, the authors performed dose calculations using baseline imaging techniques (uncorrected 120 kVp imaging) and three commercial metal artifact reduction methods: Philips Healthcare’s O-MAR, GE Healthcare’s monochromatic gemstone spectral imaging (GSI) using dual-energy CT, and GSI with metal artifact reduction software (MARS) applied. For the simple geometric phantom, radiochromic film was used to measure dose upstream and downstream of metal inserts. For the anthropomorphic phantoms, ion chambers and radiochromic film were used to quantify the benefit of the error reduction strategies. Results: Metal kernels did not universally improve accuracy but rather resulted in better accuracy upstream of metal implants and decreased accuracy directly downstream. For the clinical cases (spinal hardware and dental fillings), metal kernels had very little impact on the dose calculation accuracy (<1.0%). Of the commercial CT artifact reduction methods investigated, the authors found that O-MAR was the most consistent method, resulting in either improved dose calculation accuracy (dental case) or little impact on calculation accuracy (spine case). GSI was unsuccessful at reducing the severe artifacts caused by dental fillings and had very little impact on calculation accuracy. GSI with MARS on the other hand gave mixed results, sometimes introducing metal distortion and increasing calculation errors (titanium rectangular implant and titanium spinal hardware) but other times very successfully reducing artifacts (Cerrobend rectangular implant and dental fillings). Conclusions: Though successful at improving dose calculation accuracy upstream of metal implants, metal kernels were not found to substantially improve accuracy for clinical cases. Of the commercial artifact reduction methods investigated, O-MAR was found to be the most consistent candidate for all-purpose CT simulation imaging. The MARS algorithm for GSI should be used with caution for titanium implants, larger implants, and implants located near heterogeneities as it can distort the size and shape of implants and increase calculation errors.

60 APPLIED LIFE SCIENCES↗