Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Absorptive Weak Plume Detection on Gaussian and Non-Gaussian Background Clutter

For additive signals on Gaussian clutter, the optimal detector is a linear matched filter that is adapted to the known signal and the covariance of the background. This adaptive matched filter is widely used for gas-phase plume detection, even though the effect of the plume on the background is not strictly additive. Here, a derivation of the matched filter for a strictly absorptive plume produces, in the weak plume limit, a quadratic filter. This quadratic matched filter is extended in two ways: an elliptically-contoured multivariate t distribution is used to generalize the Gaussian background clutter, and a generalized likelihood ratio test detector is derived to extend applicability to stronger plumes. In addition to detectors whose purpose is to identify presence versus absence of a plume, expressions are also derived for estimating plume strength. The performance of these various detectors is evaluated by implanting simulated plume into background images that are either real hyperspectral images or simulated images based on different (Gaussian, multivariate t, and lognormal) clutter distributions.

79 ASTRONOMY AND ASTROPHYSICS↗

Cone beam breast CT with a high pitch (75 μm), thick (500 μm) scintillator CMOS flat panel detector: Visibility of simulated microcalcifications

Purpose: To measure and investigate the improvement of microcalcification (MC) visibility in cone beam breast CT with a high pitch (75 μm), thick (500 μm) scintillator CMOS/CsI flat panel detector (Dexela 2923, Perkin Elmer).Methods: Aluminum wires and calcium carbonate grains of various sizes were embedded in a paraffin cylinder to simulate imaging of calcifications in a breast. Phantoms were imaged with a benchtop experimental cone beam CT system at various exposure levels. In addition to the Dexela detector, a high pitch (50 μm), thin (150 μm) scintillator CMOS/CsI flat panel detector (C7921CA-09, Hamamatsu Corporation, Hamamatsu City, Japan) and a widely used low pitch (194 μm), thick (600 μm) scintillator aSi/CsI flat panel detector (PaxScan 4030CB, Varian Medical Systems) were also used in scanning for comparison. The images were independently reviewed by six readers (imaging physicists). The MC visibility was quantified as the fraction of visible MCs and measured as a function of the estimated mean glandular dose (MGD) level for various MC sizes and detectors. The modulation transfer functions (MTFs) and detective quantum efficiencies (DQEs) were also measured and compared for the three detectors used.Results: The authors have demonstrated that the use of a high pitch (75 μm) CMOS detector coupled with a thick (500 μm) CsI scintillator helped make the smaller 150–160, 160–180, and 180–200 μm MC groups more visible at MGDs up to 10.8, 9, and 10.8 mGy, respectively. It also made the larger 200–212 and 212–224 μm MC groups more visible at MGDs up to 7.2 mGy. No performance improvement was observed for 224–250 μm or larger size groups. With the higher spatial resolution of the Dexela detector based system, the apparent dimensions and shapes of MCs were more accurately rendered. The results show that with the aforementioned detector, a 73% visibility could be achieved in imaging 160–180 μm MCs as compared to 28% visibility achieved by the low pitch (194 μm) aSi/CsI flat panel detector. The measurements confirm that the Hamamatsu detector has the highest MTF, followed by the Dexel detector, and then the Varian detector. However, the Dexela detector, with its thick (500 μm) CsI scintillator and low noise level, has the highest DQE at all frequencies, followed by the Varian detector, and then the Hamamatsu detector. The findings on the MC visibility correlated well with the differences in MTFs, noise power spectra, and DQEs measured for these three detectors.Conclusions: The authors have demonstrated that the use of the CMOS type Dexela detector with its high pitch (75 μm) and thick (500 μm) CsI scintillator could help improve the MC visibility. However, the improvement depended on the exposure level and the MC size. For imaging larger MCs or scanning at high exposure levels, there was little advantage in using the Dexela detector as compared to the aSi type Varian detector. These findings correlate well with the higher measured DQEs of the Dexela detector, especially at higher frequencies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-262: Segmentation in Therapy: Impact of Display

Purpose: To determine the calibration of monitors used for structure delineation in radiotherapy and to investigate the impact of window/level on the delineations. Method and Materials: hotometers were used to measure ambient light and luminance for 12 monitors used for delineating structures in radiotherapy. Luminance was determined using AAPM TG-18 patterns TG18-LN12-01 to TG18-LN12-18. The DICOM grayscale display function (GSDF) was calculated for each monitor. To investigate the impact of window and level eight observers each outlined two sets of structures (four structures per set) on CT simulation images. In the first set window and level were initialized at random values and the observers adjusted as needed. In the second set window and level were locked at preselected values for all observers. Results: Ambient light variability at different displays was 24% and was higher than radiology reading rooms. Monitor luminance curves were substantially different than the corresponding GSDF. Monitors demonstrated higher contrast than the GSDF in the lower third of driving levels and lower contrast in the upper third of driving levels. Increased contrast at low driving levels may be to compensate for high ambient light which would otherwise reduce contrast. Abrupt changes in luminance and loss of all contrast at both upper and lower driving levels was observed. Interobserver variability was 379HU for window and 217HU for level. Outline variability was lower when the window and level settings were similar and when they were preselected. Structures without sharp boundaries (e.g., partial volume and a wide window value) resulted in substantial interobserver variability even when window/level were preselected. Conclusion: Substantial variation in monitor calibration and ambient light exists in radiotherapy. Further, the substantially different window/level contributes to outline variability. Future work will quantify the contributions of monitor calibration and window/level on outline variability and accuracy.

60 APPLIED LIFE SCIENCES↗

TU-C-17A-03: An Integrated Contour Evaluation Software Tool Using Supervised Pattern Recognition for Radiotherapy

Purpose: Radiotherapy (RT) contours delineated either manually or semiautomatically require verification before clinical usage. Manual evaluation is very time consuming. A new integrated software tool using supervised pattern contour recognition was thus developed to facilitate this process. Methods: The contouring tool was developed using an object-oriented programming language C# and application programming interfaces, e.g. visualization toolkit (VTK). The C# language served as the tool design basis. The Accord.Net scientific computing libraries were utilized for the required statistical data processing and pattern recognition, while the VTK was used to build and render 3-D mesh models from critical RT structures in real-time and 360° visualization. Principal component analysis (PCA) was used for system self-updating geometry variations of normal structures based on physician-approved RT contours as a training dataset. The inhouse design of supervised PCA-based contour recognition method was used for automatically evaluating contour normality/abnormality. The function for reporting the contour evaluation results was implemented by using C# and Windows Form Designer. Results: The software input was RT simulation images and RT structures from commercial clinical treatment planning systems. Several abilities were demonstrated: automatic assessment of RT contours, file loading/saving of various modality medical images and RT contours, and generation/visualization of 3-D images and anatomical models. Moreover, it supported the 360° rendering of the RT structures in a multi-slice view, which allows physicians to visually check and edit abnormally contoured structures. Conclusion: This new software integrates the supervised learning framework with image processing and graphical visualization modules for RT contour verification. This tool has great potential for facilitating treatment planning with the assistance of an automatic contour evaluation module in avoiding unnecessary manual verification for physicians/dosimetrists. In addition, its nature as a compact and stand-alone tool allows for future extensibility to include additional functions for physicians’ clinical needs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Upper limits of the photon fluence rate on CT detectors: Case study on a commercial scanner

Purpose: The highest photon fluence rate that a computed tomography (CT) detector must be able to measure is an important parameter. The authors calculate the maximum transmitted fluence rate in a commercial CT scanner as a function of patient size for standard head, chest, and abdomen protocols. Methods: The authors scanned an anthropomorphic phantom (Kyoto Kagaku PBU-60) with the reference CT protocols provided by AAPM on a GE LightSpeed VCT scanner and noted the tube current applied with the tube current modulation (TCM) system. By rescaling this tube current using published measurements on the tube current modulation of a GE scanner [N. Keat, “CT scanner automatic exposure control systems,” MHRA Evaluation Report 05016, ImPACT, London, UK, 2005], the authors could estimate the tube current that these protocols would have resulted in for other patient sizes. An ECG gated chest protocol was also simulated. Using measured dose rate profiles along the bowtie filters, the authors simulated imaging of anonymized patient images with a range of sizes on a GE VCT scanner and calculated the maximum transmitted fluence rate. In addition, the 99th and the 95th percentiles of the transmitted fluence rate distribution behind the patient are calculated and the effect of omitting projection lines passing just below the skin line is investigated. Results: The highest transmitted fluence rates on the detector for the AAPM reference protocols with centered patients are found for head images and for intermediate-sized chest images, both with a maximum of 3.4 ⋅ 10{sup 8} mm{sup −2} s{sup −1}, at 949 mm distance from the source. Miscentering the head by 50 mm downward increases the maximum transmitted fluence rate to 5.7 ⋅ 10{sup 8} mm{sup −2} s{sup −1}. The ECG gated chest protocol gives fluence rates up to 2.3 ⋅ 10{sup 8} − 3.6 ⋅ 10{sup 8} mm{sup −2} s{sup −1} depending on miscentering. Conclusions: The fluence rate on a CT detector reaches 3 ⋅ 10{sup 8} − 6 ⋅ 10{sup 8} mm{sup −2} s{sup −1} in standard imaging protocols, with the highest rates occurring for ECG gated chest and miscentered head scans. These results will be useful to developers of CT detectors, in particular photon counting detectors.

60 APPLIED LIFE SCIENCES↗

SU-F-T-442: Dose Distribution Comparison for Post-Laryngectomy Stoma Area Between Conventional AP and VMAT Plans with Or Without Bolus

Purpose: To compare dose distributions of conventional AP vs. VMAT treatment plans with or without bolus around post-laryngectomy stoma. Methods: Radiation dose coverage for post-laryngectomy stoma was analyzed using a set of real-case CT-simulation images. After meticulous contouring of the catheter cuff, stoma lumen, peri-stoma skin and subclinical tumor bed at the larynx, the resulting dosimetry plans were analyzed with or without a 5 mm bolus placement. Wet gauze was used to minimize the effect of any air gap. Four plans were generated: AP superclavicular (SCV) plan with or without bolus, and VMAT plan with or without bolus. A dose of 60Gy in 30 fractions was prescribed at 3 cm depth for AP SCV plan, and to 95% of the PTV volume for VMAT plan. Results: For the conventional AP SCV plan, the peri-stoma skin dose is sensitive to bolus placement as well as air gap compensation by wetted gauze (V95% of 20.7%, 33.0% and 94.8% for no bolus, bolus without and with air gap compensation, respectively). For stoma lumen, the dose drops off rapidly in depth. The catheter cuff may have certain dose-buildup effect, but air gap around it and under the bolus placed can pose a more serious problem. The dose distributions of the two VMAT plans are moderately different for peri-stoma skin (V95% of 95.0% with bolus and air gap compensation, and 82.3% without bolus), but nearly identical for stoma lumen (V95% of 91.5% and 92.0%, respectively). VMAT allows beamlets with different angles of incidence that helped achieve such dose distribution around the stoma even without bolus placement. Conclusion: Overall, the dose coverage around the stoma in the VMAT plan is better than the conventional AP SCV plan. To achieve optimal dose distribution, it is still recommended to place physical bolus and reduce the air gaps.

60 APPLIED LIFE SCIENCES↗

KSpaceNavigator (KSN)

Intuitive GUI for manipulating microscope stages, allowing to align crystallographic data with stages, allowing to align crystallographic data with stage coordinates and microscope images. Simulates kinematic diffraction patterns and Kikuchi line patterns. Simulated patterns can be displayed as overlay to actually measured data, allowing manual fingerprinting and angular alignment. Crystallographic data is fed to the program in form of CIF (crystallographic information file) files, which are available from many databases and cover virtually all crystal structure ever reported in any journal. Actual goniometer scales can be linearized by lookup tables, program can be used with any microscope goniometer, double tilt and tilt-rotation type. Software requirements: Win32 platform (XP); Compiler/Version: Borland C++ Builder 5; Type of files: Executable modules; Hardware requirement: PC

Duden, Thomas↗

gp_blendclass_singleband

The code used for the data preprocessing, image simulation, and model training and analysis reported in the paper "Gaussian Process Classification for Galaxy Blend Identification in LSST" (arXiv:2107.09246).

Buchanan, JamesJ.↗

DeepLensSBI: Deep inference of simulated strong lenses in ground-based surveys

This code is used to train and test machine learning models and generate results and plots presented in 2501.08524 [astro-ph.IM]. The code is written in python. The goal of this work is to train ML models trained on simulated images of strong gravitational lenses. The trained model can then quickly infer properties of the lensed objects with uncertainty quantification.

Poh, Jason [Univ. of Chicago, IL (United States)] ↗

DeepBench: A simulation package for physical benchmarking data

We introduce **DeepBench**, a python library that generates simple simulated image data from first principles, such as basic geometric shapes and astronomical objects. These data are highly valuable for developing (calibration, testing, and benchmarking) statistical and machine learning models because they make it possible to connect the final data product to physically interpretable inputs. This software includes tools to curate and store the datasets to maximize reproducibility.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Imaging of Phase Objects using Partially Coherent Illumination

Screening high-power laser optics for light intensifying phase objects that cause laserinduced damage on downstream optics is critical to sustaining laser operation. Identifying such flaws on large-apertures is quite challenging since they are relatively small and invisible to conventional inspection methods. A Linescan Phase Differential Imaging (LPDI) system was developed to rapidly identify these flaws on large-aperture optics within a single full-aperture dark-field image. We describe a two-step production phase object screening process consisting of LPDI mapping and image analysis, followed by high-resolution interferometry and propagation based evaluation of the downstream damage potential of identified flaws. An image simulation code capable of modeling the LPDI partially coherent illumination was used to optimize its phase object sensitivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coupling a Lagrangian–Eulerian Spark-Ignition (LESI) model with LES combustion models for engine simulations

In the United States transportation sector, Light-Duty Vehicles (LDVs) are the largest energy consumers and CO 2 emitters. Electrification of LDVs is posed as a potential solution, but SI engines can still contribute to decarbonization. Car manufacturers have turned to unconventional engine operation to increase the efficiency of Spark-Ignition (SI) engines and reduce the carbon emissions of their fleets. Dilute, lean, and stratified-charge engine operation has the potential for engine efficiency improvements at the expense of increased cyclic variability and combustion instability. At such demanding engine conditions, the spark ignition event is key for flame initiation and propagation and for enhanced combustion stability. Reliable and accurate spark ignition models can help design ignition systems that reduce cyclic variability. Multiple computational spark-ignition models exist that perform well under conventional conditions, but the underlying physics needs to be expanded, for unconventional engine operation. In this paper, a hybrid Lagrangian–Eulerian Spark-Ignition (LESI) model is coupled with different turbulent flame propagation models for engine simulations. LESI relies on Lagrangian arc tracking and Eulerian energy deposition. The LESI model is coupled with the Well-Stirred Reactor (WSR), Thickened Flame Model (TFM), and g-equation model and used to simulate several cycles of a Direct-Injection Spark-Ignition (DISI) engine using a commercial Computational Fluid Dynamics (CFD) engine solver. The results showcase the successful coupling of LESI with the combustion models. Global engine metrics, such as pressure and Apparent Heat Release Rate (AHRR), for each simulation setup are compared to experimental engine results, for validation. In addition, results highlight the successful prediction of spark channel movement by comparing simulation images to experimental optical engine images. Finally, the successful coupling of LESI to combustion models, making it a usable model in the engine modeling community, is emphasized and future development details are discussed.

33 ADVANCED PROPULSION SYSTEMS↗

Galaxy Clustering with LSST: Effects of Number Count Bias from Blending

The Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST) will survey the southern sky to create the largest galaxy catalog to date, and its statistical power demands an improved understanding of systematic effects such as source overlaps, also known as blending. In this work we study how blending introduces a bias in the number counts of galaxies (instead of the flux and colors), and how it propagates into galaxy clustering statistics. We use the 300 deg 2 DC2 image simulation and its resulting galaxy catalog (LSST Dark Energy Science Collaboration et al. 2021) to carry out this study. We find that, for a LSST Year 1 (Y1)-like cosmological analyses, the number count bias due to blending leads to small but statistically significant differences in mean redshift measurements when comparing an observed sample to an unblended calibration sample. In the two-point correlation function, blending causes differences greater than 3σ on scales below approximately 10', but large scales are unaffected. We fit Ω m and linear galaxy bias in a Bayesian cosmological analysis and find that the recovered parameters from this limited area sample, with the LSST Y1 scale cuts, are largely unaffected by blending. Our main results hold when considering photometric redshift and a LSST Year 5 (Y5)-like sample.

79 ASTRONOMY AND ASTROPHYSICS↗

The DECADE cosmic shear project I: A new weak lensing shape catalog of 107 million galaxies

We present the Dark Energy Camera All Data Everywhere (DECADE) weak lensing dataset: a catalog of 107 million galaxies observed by the Dark Energy Camera (DECam) in the northern Galactic cap. This catalog was assembled from public DECam data including survey and standard observing programs. These data were consistently processed with the Dark Energy Survey Data Management pipeline as part of the DECADE campaign and serve as the basis of the DECam Local Volume Exploration survey (DELVE) Early Data Release 3 (EDR3). We apply the Metacalibration measurement algorithm to generate and calibrate galaxy shapes. After cuts, the resulting cosmology-ready galaxy shape catalog covers a region of $5,\!412 \,\,{\rm deg}^2$ with an effective number density of $4.59\,\, {\rm arcmin}^{-2}$. The coadd images used to derive this data have a median limiting magnitude of $r = 23.6$, $i = 23.2$, and $z = 22.6$, estimated at ${\rm S/N} = 10$ in a 2 arcsecond aperture. We present a suite of detailed studies to characterize the catalog, measure any residual systematic biases, and verify that the catalog is suitable for cosmology analyses. In parallel, we build an image simulation pipeline to characterize the remaining multiplicative shear bias in this catalog, which we measure to be $m = (-2.454 \pm 0.124) \times10^{-2}$ for the full sample. Despite the significantly inhomogeneous nature of the data set, due to it being an amalgamation of various observing programs, we find the resulting catalog has sufficient quality to yield competitive cosmological constraints.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Galaxies into the Dark Ages

We consider the capabilities of current and future large facilities operating at 2–3 mm wavelength to detect and image the [C ii] 158 μm line from galaxies into the cosmic “dark ages” (z ∼ 10–20). The [C ii] line may prove to be a powerful tool in determining spectroscopic redshifts, and galaxy dynamics, for the first galaxies. We emphasize that the nature, and even existence, of such extreme redshift galaxies, remains at the frontier of open questions in galaxy formation. In 40 hr, the Atacama Large Millimeter Array has the sensitivity to detect the integrated [C ii] line emission from a moderate metallicity, active star-forming galaxy [Z{sub A}=0.2 Z{sub ⊙}; star formation rate (SFR)=5 M{sub ⊙} yr{sup −1}], at z = 10 at a significance of 6σ. The next-generation Very Large Array (ngVLA) will detect the integrated [C ii] line emission from a Milky Way–like SFR galaxy (Z{sub A}=0.2 Z{sub ⊙}, SFR=1 M{sub ⊙} yr{sup −1}), at z = 15 at a significance of 6σ. Imaging simulations show that the ngVLA can determine rotation dynamics for active star-forming galaxies at z∼15, if they exist. Based on our very limited knowledge of the extreme redshift universe, we calculate the count rate in blind, volumetric surveys for [C ii] emission at z∼10–20. The detection rates in blind surveys will be slow (of the order of unity per 40 hr pointing). However, the observations are well suited to commensal searches. We compare [C ii] with the [O iii] 88 μm line, and other ancillary information in high z galaxies that would aid these studies.

79 ASTRONOMY AND ASTROPHYSICS↗

Resolved Dwarf Galaxy Searches within ~5 Mpc with the Vera Rubin Observatory and Subaru Hyper Suprime-Cam*

We present a preview of the faint dwarf galaxy discoveries that will be possible with the Vera C. Rubin Observatory and Subaru Hyper Suprime-Cam in the next decade. In this work, we combine deep ground-based images from the Panoramic Imaging Survey of Centaurus and Sculptor (PISCeS) and extensive image simulations to investigate the recovery of faint, resolved dwarf galaxies in the Local Volume with a matched-filter technique. We adopt three fiducial distances - 1.5, 3.5, 5 Mpc, and quantitatively evaluate the effects on dwarf detection of varied stellar backgrounds, ellipticity, and Milky Way foreground contamination and extinction. We show that our matched-filter method is powerful for identifying both compact and extended systems, and near-future surveys will be able to probe at least ~4.5 mag below the tip of the red giant branch (TRGB) for a distance of up to 1.5 Mpc, and ~2 mag below the TRGB at 5 Mpc. This will push the discovery frontier for resolved dwarf galaxies to fainter magnitudes, lower surface brightnesses, and larger distances. Our simulations show the secure census of dwarf galaxies down to $M_{V}$$\approx$-5, -7, -8, will be soon within reach, out to 1.5 Mpc, 3.5 Mpc, and 5 Mpc, respectively, allowing us to quantify the statistical fluctuations in satellite abundances around hosts, and parse environmental effects as a function of host properties.

79 ASTRONOMY AND ASTROPHYSICS↗

Deep Realistic Extragalactic Model (DREaM) Galaxy Catalogs: Predictions for a Roman Ultra-deep Field

In the next decade, deep galaxy surveys from telescopes such as the James Webb Space Telescope and Roman Space Telescope will provide transformational data sets that will greatly enhance the understanding of galaxy formation during the epoch of reionization (EoR). In this work, we present the Deep Realistic Extragalactic Model (DREaM) for creating synthetic galaxy catalogs. Our model combines dark matter simulations, subhalo abundance matching and empirical models, and includes galaxy positions, morphologies, and spectral energy distributions. The resulting synthetic catalog extends to redshifts z ~ 12, and galaxy masses log 10 (M/M ⊙ ) = 5 covering an area of 1 deg 2 on the sky. We use DREaM to explore the science returns of a 1 deg 2 Roman ultra-deep field (UDF), and to provide a resource for optimizing ultra-deep survey designs. We find that a Roman UDF to ~30 m AB will potentially detect more than 10 6 M UV < -17 galaxies, with more than 10 4 at redshifts z > 7, offering an unparalleled data set for constraining galaxy properties during the EoR. Our synthetic catalogs and simulated images are made publicly available to provide the community with a tool to prepare for upcoming data.

79 ASTRONOMY AND ASTROPHYSICS↗

Systematic Biases in Weak Lensing Cosmology with the Dark Energy Survey

This thesis sets out a practical guide to applying shear measurements as a cosmological tool. We first present one of two science-ready galaxy shape catalogues from Year 1 of the Dark Energy Survey (DES Y1), which covers 1500 square degrees in four bands $griz$, with a median redshift of $0.59$. We describe the shape measurement process implemented by the DES Y1 imshape catalogue, which contains 21.9 million high-quality $r$-band bulge/disc fits. In Chapter 3 a new suite of image simulations, referred to as Hoopoe, are presented. The Hoopoe dataset is tailored to DES Y1 and includes realistic blending, spatial masks and variation in the point spread function. We derive shear corrections, which we show are robust to changes in calibration method, galaxy binning and variance within the simulated dataset. Sources of systematic uncertainty in the simulation-based shear calibration are discussed, leading to a final estimate of the $1\sigma$ uncertainties in the residual multiplica tive bias after calibration of 0.025. Chapter 4 describes an extension of the analysis on the Hoopoe simulations into a detailed investigation of the impact of galaxy neighbours on shape measurement and shear cosmology. Four mechanisms by which neighbours can have a non-negligible influence on shear measurement are identified. These effects, if ignored, would contribute a net multiplicative bias of $m \sim 0.03 - 0.09$ in DES Y1, though the precise impact will depend on both the measurement code and the selection cuts applied. We use the cosmological inference pipeline of DES Y1 to explore the cosmological implications of neighbour bias and show that omitting blending from the calibration simulation for DES Y1 would bias the inferred clustering amplitude $S_8 \equiv \sigma_8 (\omegam /0.3)^{0.5}$ by $1.5 \sigma$ towards low values. Finally, we use the Hoopoe simulations to test the effect of neighbour-induced spatial correlations in the multiplicative bias. We find the cosmo logical impact to be subdominant to statistical error at the! current level of precision. Another major uncertainity in shear cosmology is the accuracy of our ensemble redshift distributions. Chapter 5 presents a numerical investigation into the combined constraining power of cosmic shear, galaxy clustering and their cross-correlation in DES Y1, and the potential for internal calibration of redshift errors. Introducing a moderate uniform bias into the redshift distributions used to model the weak lensing (WL) galaxies is shown to produce a $> 2\sigma$ bias in $S_8$. We demonstrate that this cosmological bias can be eliminated by marginalising over redshift error nuisance parameters. Strikingly, the cosmological constraint of the combined dataset is largely undiminished by the loss of prior information on the WL distributions. We demonstrate that this implicit self-calibration is the result of complementary degeneracy directions in the combined data. In Chapter 6 we present the preliminary results of an investigation into galaxy intrin sic alignments. Using the DES Y1 data, we show a clear dependence in alignment amplitude on galaxy type, in agreement with previous results. We subject these findings to a series of initial robustness tests. We conclude with a short overview of the work presented, and discuss prospects for the future.

79 ASTRONOMY AND ASTROPHYSICS↗