Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image plates”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Analysis of the nebulosities near T Tauri using digital computer image processing

Direct plates of T Tauri taken with the 120-inch (3 m) and 36-inch (91 cm) Lick reflectors were digitized and analyzed using digital-computer image-processing techniques. Luminous emission protrusions extending to as far as 13-sec from T Tauri in position angles 170 deg, 210 deg, and 330 deg are shown. These features are variable and may contain a layered structure. The complex reflection nebula west of T Tauri (NGC 1555) appears to be an illuminated portion of a much larger dark nebula whose variability is due to obscuring material near the star.

Lorre, J. J.↗

ASTROMETRY.NET: BLIND ASTROMETRIC CALIBRATION OF ARBITRARY ASTRONOMICAL IMAGES

We have built a reliable and robust system that takes as input an astronomical image, and returns as output the pointing, scale, and orientation of that image (the astrometric calibration or World Coordinate System information). The system requires no first guess, and works with the information in the image pixels alone; that is, the problem is a generalization of the 'lost in space' problem in which nothing-not even the image scale-is known. After robust source detection is performed in the input image, asterisms (sets of four or five stars) are geometrically hashed and compared to pre-indexed hashes to generate hypotheses about the astrometric calibration. A hypothesis is only accepted as true if it passes a Bayesian decision theory test against a null hypothesis. With indices built from the USNO-B catalog and designed for uniformity of coverage and redundancy, the success rate is >99.9% for contemporary near-ultraviolet and visual imaging survey data, with no false positives. The failure rate is consistent with the incompleteness of the USNO-B catalog; augmentation with indices built from the Two Micron All Sky Survey catalog brings the completeness to 100% with no false positives. We are using this system to generate consistent and standards-compliant meta-data for digital and digitized imaging from plate repositories, automated observatories, individual scientific investigators, and hobbyists. This is the first step in a program of making it possible to trust calibration meta-data for astronomical data of arbitrary provenance.

07 ISOTOPE AND RADIATION SOURCES↗

Virtual anode effect in the propagation of positive streamers

Experiments made in a parallel-plate arrangement, where one of the plates is the ground plane and the other a positively charged dielectric sheet, show that at low air pressure the dielectric injects streamers onto the surrounding air. The similarities and differences between the streamers thus produced and those emitted from electrodes are discussed. The streamers here obtained were found to have diameters and speeds that are clearly dependent on pressure. Often the streamers were seen to decelerate markedly to the point of coming to a complete stop and on occasions even returning back to the dielectric they came from. The deceleration and the reflection of the streamers are attributed to a virtual anode created by the electrostatic image of the head's charge behind the ground plane. Field calculations performed corroborate this hypothesis. Through the use of an equation of motion of the positive head, it is then possible to obtain an estimate of the magnitude of its charge. The charge thus obtained was found to be in the 2.5–26 nC range.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nanograting-based compact VUV spectrometer and beam profiler for in-situ characterization of high-order harmonic generation light sources

A compact, versatile device for VUV beam characterization is presented. It combines the functionalities of a VUV spectrometer and a VUV beam profiler in one unit and is entirely supported by a standard DN200 CF flange. The spectrometer employs a silicon nitride transmission nanograting in combination with a micro-channel plate based imaging detector. This enables the simultaneous recording of wavelengths ranging from 10 nm to 80 nm with a resolution of 0.25 nm to 0.13 nm. Spatial beam profiles with diameters up to 10 mm are imaged with 0.1 mm resolution. The setup is equipped with an in-vacuum translation stage that allows for in situ switching between the spectrometer and beam profiler modes and for moving the setup out of the beam. The simple, robust design of the device is well suited for non-intrusive routine characterization of emerging laboratory- and accelerator-based VUV light sources. Operation of the device is demonstrated by characterizing the output of a femtosecond high-order harmonic generation light source.

42 ENGINEERING↗

Least Squares Reverse Time Migration (LSRTM) for Damage Imaging in Composite Laminates

A method for adapting least squares reverse time migration (LSRTM) for ultrasonic guided wave imaging of composite laminates is proposed in this paper. As composites become more widely used in fields such as the aerospace industry, the need for high-resolution imaging in structural health monitoring (SHM) and nondestructive evaluation (NDE) is also growing. For instance, delamination is a common problem in composite laminates, which has led to a certain degree of apprehension in the use of composite materials for load-bearing structures. Although the solver-based imaging techniques using conventional reverse time migration (RTM) methods illuminate damage with a wide range of damage-scattering effects, the resulting images do not fully define the damage regions due to the limited data acquisition aperture, sensor density, frequencies/wavelengths, and incompleteness of adjoint reconstruction. Previously, the LSRTM theory was derived by incorporating a least squares migration (LSM) algorithm into RTM, and benchmarked its high-resolution damage imaging performance for isotropic plates. To improve damage imaging in composite laminates, a process to create an ultrasonic guided wave-based LSRTM method for anisotropic materials is proposed in this paper. The derivation of the forward modeling operator and the adjoint operator is presented. Numerical case studies were conducted to show the improvement of LSRTM over RTM in mapping damage in composite plates. Multiple damage sites or damage with a complex shape were created in the numerical studies based on 1) Born approximation-based modeling or 2) reduction of the plate stiffness-based modeling. LSRTM begins by using a forward modeling process. The forward modeling accuracy for the flexural wave solver used in this study for LSRTM was also compared with the results from a three-dimensional rotated staggered grid (RSG) elastodynamic finite difference solver, previously open-sourced by NASA Langley Research Center. These benchmarking studies have shown that the LSRTM method is more effective in reducing artifacts, improving resolution, and enhancing damage model reconstruction compared to RTM in composite laminates.

Jiaze He↗

Mars 2001 Lander Mission: Measurement Synergy Through Coordinated Operations Planning And Implementation

The 2001 Mars Surveyor Program Mission includes an orbiter with a gamma ray spectrometer and a multispectral thermal imager, and a lander with an extensive set of instrumentation, a robotic arm, and the Marie Curie Rover. The Mars 2001 Science Operations Working Group (SOWG) is a subgroup of the Project Science Group that has been formed to provide coordinated planning and implementation of scientific observations, particularly for the landed portion of the mission. The SOWG will be responsible for delivery of a science plan and, during operations, generation and delivery of conflict-free sequences. This group will also develop an archive plan that is compliant with Planetary Data System (PDS) standards, and will oversee generation, validation, and delivery of integrated archives to the PDS. In this report we cover one element of the SOWG planning activities, the development of a plan that maximizes the scientific return from lander-based observations by treating the instrument packages as an integrated payload. Scientific objectives for the lander mission have been defined. They include observations focused on determining the bedrock geology of the site through analyses of rocks and also local materials found in the soils, and the surficial geology of the site, including windblown deposits and the nature and history of formation of indurated sediments such as duricrust. Of particular interest is the identification and quantification of processes related to early warm, wet conditions and the presence of hydrologic or hydrothermal cycles. Determining the nature and origin of duricrust and associated salts is -very important in this regard. Specifically, did these deposits form in the vadose zone as pore water evaporated from soils or did they form by other processes, such as deposition of volcanic aerosols? Basic information needed to address these questions includes the morphology, topography, and geologic context of landforms and materials exposed at the site, together with quantitative information on material mineralogy, chemistry, and physical properties (rock textures; soil grain size and shape distributions; degree and nature of soil induration; soil magnetic properties). The calibration targets provide radiometric and mineralogical control surfaces. The magnets allow observations of magnetic phases. Patch plates are imaged to determine adhesive and abrasive properties of soils. Coordinated mission planning is crucial for optimizing the measurement synergy among the packages included on the lander. This planning has already begun through generation of multi-sol detailed operations activities. One focus has been to develop a scenario to use the arm to dig a soil trench to a depth of tens of centimeters. The activity will be monitored through use of Pancam and RAC to ensure nominal operations and to acquire data to determine subsurface physical properties (e.g., angle of repose of trench walls). Pancam and Mini-TES observations would also provide constraints on mineralogy and texture for the walls and bottom of the trench during excavation. If desired, soils excavated at depth could be deposited on the surface and Mossbauer and APXS measurements could be acquired for these materials. Soil samples from various depths would be delivered to MECA for characterization of aqueous geochemistry and physical properties of soil grains, particularly size, shape, and hardness. These physical properties would be determined by optical and atomic force microscopy. When completed, detailed information of soil properties as a function of depth would be obtained. These various data sets would constrain our understanding of whether or not there are systematic variations in soil characteristics as a function of depth. These variations might be related, for example, to evaporative moisture losses and formation of salt deposits, thereby indicating water transport processes occurred fairly recently. Many other value-added measurement scenarios are being developed. For example, characterizing the nature and dynamics of dust deposition will be done using MIP/DART to provide deposition rates, Pancam and RAC imaging of lander and rover surfaces to extrapolate these measurements to other areas, and a variety of measurements to determine if the bulk loose soil has the same characteristics as dust that accumulates during the mission. Bedrock geology of the site is primarily an APEX-focus setting, mineralogy, and texture, and APXS data to be we interest will be to determine the extent to which rock hydrothermal processes, given that APEX is the precursor 4 and 2005 rover missions. Additional information is contained in the original.

Arvidson, R.↗

Laser-ablation sampling for inductively coupled plasma distance-of-flight mass spectrometry

An inductively coupled plasma distance-of-flight mass spectrometer (ICP-DOFMS) has been coupled with laser-ablation (LA) sample introduction for the elemental analysis of solids. ICP-DOFMS is well suited for the analysis of laser-generated aerosols because it offers both high-speed mass analysis and simultaneous multi-elemental detection. Here, we evaluate the analytical performance of the LA-ICP-DOFMS instrument, equipped with a microchannel plate-based imaging detector, for the measurement of steady-state LA signals, as well as transient signals produced from single LA events. Steady-state detection limits are 1 mg g1, and absolute single-pulse LA detection limits are 200 fg for uranium; the system is shown capable of performing time-resolved single-pulse LA analysis. By leveraging the benefits of simultaneous multi-elemental detection, we also attain a good shot-to-shot reproducibility of 6% relative standard deviation (RSD) and isotope-ratio precision of 0.3% RSD with a 10 s integration time.

Gundlach-Graham, Alexander W.↗

Study of Fast, Near-Infrared Photodetectors for the ITER Core LIDAR Thomson Scattering

A key component for the ITER core LIDAR Thomson Scattering (TS) diagnostic would be a detector with good sensitivity in the 850-1060 nm near infrared (NIR) spectral region. Covering this spectral region becomes necessary if a Nd:YAG laser system operating at {lambda} = 1.06 {mu}m is used as the laser source, which is a very attractive choice in terms of available energy, repetition rate, reliability and cost. In this paper we review the state of the art of two types of detectors available for the above spectral range: the transferred electron (TE) InGaAs/InP hybrid photodiode and the In{sub x}Ga{sub 1-x}As microchannel plate (MCP) image intensifier and we describe the advancements necessary for a possible application in the ITER LIDAR TS. In addition we describe the preliminary characterization of new GaAsP fast MCP photomultipliers (PMTs) suitable for the detection of the visible part of the LIDAR TS spectrum in JET and ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Two-photon polymerization printed lattices as support structures in multi-shell ICF targets: Platform development and initial assessment

Recent interest in fielding direct drive multi-shell targets on the NIF [K. Molvig et al., Phys. Rev. Lett. 116, 255003 (2016) and S. X. Hu et al., Phys. Rev. E 100, 063204 (2019)] has highlighted the need for a low density structure to support the inner shell(s) and to avoid energy loss in the acceleration and collision process. We have developed a two-shell platform to evaluate the use of low density two-photon polymerization (2PP) printed lattices as a support structure between the shells. Here, 2PP structures are an attractive option because they can be produced at densities as low as 5 mg/cc, which is ideal for multi-shell targets, and their 3D structure can be tailored to the user's needs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Emulsion droplets detection suite

The code is a set of Python libraries/scripts that leverage open source computer vision packages like YOLO and SAM2 to identify emulsion droplets in plate reader images and videos of microfluidic device flows.

Reddy, Tyler [LANL]↗

High Intensity Gamma-Ray Source(HIγS) Radiographic Experiments

High Intensity Gamma-ray Source (HIGS) is a Free-Electron Laser (FEL) based Compton back-scattering γ-ray source. The HIGS facility is located on the campus of Duke University and operated by Triangle Universities Nuclear Laboratory (TUNL).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Medical electronics: A need and a challenge

Space programs have led to the development of telemetry pills for diagnosis of diseases of the digestive tract, reusable X-ray image storage plates that require no chemical processing, and muscular augmentation systems for the handicapped. These examples, together with countless other examples of technological innovation that can be drawn from research and development programs supported by government funds, offer a potential opportunity to stimulate growth and to control rising costs in medical electronics.

Dimeoff, J.↗

Optical studies of the regions of the gamma-ray bursts of 19 November, 1978 and 5 March, 1979

Optical studies were made of two well-located gamma-ray burst regions in the Southern Hemisphere using the 1.5 m telescope at the Cerro Tololo Inter-American Observatory in Chile. Multi-filter image tube plates and UBV photometry surveys were made of both regions. The field of the 19 November, 1978 gamma-ray burst shows no early star or star with unusual colors out to several diameters of the nominal error box. The region of the 5 March, 1979 gamma-ray burst, which includes N49, contains several blue giants in the LMC, two of which deserve further study.

Fishman, G. J.↗

The soft X-ray/EUV calibration facility at the University of Colorado

The components of the calibration facility at the University of Colorado are described. The system is capable of analyzing the performance of optical components in the wavelength range from 2.7 to 2500 A. The system uses two light sources: a water-cooled hollow cathode gas discharge source and a soft X-ray source. The 2.2-m grazing incidence monochrometer, slits, large chamber, and computer-controlled manipulator are examined. The NBS aluminum oxide photodiode, a flowing gas proportional counter, and an imaging microchannel plate device are employed to detect the light. The optics, detectors, and data acquisition system are computer controlled. The facility is applicable for evaluating the performance of diffraction gratings, multilayer mirrors, reflective coatings, spectrographs, surface roughness scattering, and absolute detector efficiencies. Examples demonstrating the capabilities of the facility and a diagram of the facility are presented.

Windt, David L.↗

Correlation between low level fluctuations in the x ray background and faint galaxies

A correlation between low-level x-ray fluctuations in the cosmic x-ray background flux and the large numbers of galaxies found in deep optical imaging, to m(sub v) is less than or equal to 24 - 26, is desired. These (faint) galaxies by their morphology and color in deep multi-color CCD images and plate material were optically identified. Statistically significant correlations between these galaxies and low-level x-ray fluctuations at the same positions in multiple deep Einstein HRI observations in PAVO and in a ROSAT PSPC field were searched for. Our aim is to test the hypothesis that faint 'star burst' galaxies might contribute significantly to the cosmic x-ray background (at approximately 1 keV).

Tolstoy, Eline↗

Macromolecular Topography Leaps into the Digital Age

A low-cost, real-time digital topography system is under development which will replace x-ray film and nuclear emulsion plates. The imaging system is based on an inexpensive surveillance camera that offers a 1000x1000 array of 8 im square pixels, anti-blooming circuitry, and very quick read out. Currently, the system directly converts x-rays to an image with no phosphor. The system is small and light and can be easily adapted to work with other crystallographic equipment. Preliminary images have been acquired of cubic insulin at the NSLS x26c beam line. NSLS x26c was configured for unfocused monochromatic radiation. Six reflections were collected with stills spaced from 0.002 to 0.001 degrees apart across the entire oscillation range that the reflections were in diffracting condition. All of the reflections were rotated to the vertical to reduce Lorentz and beam related effects. This particular CCD is designed for short exposure applications (much less than 1 sec) and so has a relatively high dark current leading to noisy raw images. The images are processed to remove background and other system noise with a multi-step approach including the use of wavelets, histogram, and mean window filtering. After processing, animations were constructed with the corresponding reflection profile to show the diffraction of the crystal volume vs. the oscillation angle as well as composite images showing the parts of the crystal with the strongest diffraction for each reflection. The final goal is to correlate features seen in reflection profiles captured with fine phi slicing to those seen in the topography images. With this development macromolecular topography finally comes into the digital age.

Lovelace, J.↗

Automated Guided-Wave Scanning Developed to Characterize Materials and Detect Defects

The Nondestructive Evaluation (NDE) Group of the Optical Instrumentation Technology Branch at the NASA Glenn Research Center has developed a scanning system that uses guided waves to characterize materials and detect defects. The technique uses two ultrasonic transducers to interrogate the condition of a material. The sending transducer introduces an ultrasonic pulse at a point on the surface of the specimen, and the receiving transducer detects the signal after it has passed through the material. The aim of the method is to correlate certain parameters in both the time and frequency domains of the detected waveform to characteristics of the material between the two transducers. The scanning system is shown. The waveform parameters of interest include the attenuation due to internal damping, waveform shape parameters, and frequency shifts due to material changes. For the most part, guided waves are used to gauge the damage state and defect growth of materials subjected to various mechanical or environmental loads. The technique has been applied to polymer matrix composites, ceramic matrix composites, and metal matrix composites as well as metallic alloys. Historically, guided wave analysis has been a point-by-point, manual technique with waveforms collected at discrete locations and postprocessed. Data collection and analysis of this type limits the amount of detail that can be obtained. Also, the manual movement of the sensors is prone to user error and is time consuming. The development of an automated guided-wave scanning system has allowed the method to be applied to a wide variety of materials in a consistent, repeatable manner. Experimental studies have been conducted to determine the repeatability of the system as well as compare the results obtained using more traditional NDE methods. The following screen capture shows guided-wave scan results for a ceramic matrix composite plate, including images for each of nine calculated parameters. The system can display up to 18 different wave parameters. Multiple scans of the test specimen demonstrated excellent repeatability in the measurement of all the guided-wave parameters, far exceeding the traditional point-by-point technique. In addition, the scan was able to detect a subsurface defect that was confirmed using flash thermography This technology is being further refined to provide a more robust and efficient software environment. Future hardware upgrades will allow for multiple receiving transducers and the ability to scan more complex surfaces. This work supports composite materials development and testing under the Ultra-Efficient Engine Technology (UEET) Project, but it also will be applied to other material systems under development for a wide range of applications.

Martin, Richard E.↗