Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Boron-Based Neutron Scintillator Screens for Neutron Imaging

In digital neutron imaging, the neutron scintillator screen is a limiting factor of spatial resolution and neutron capture efficiency and must be improved to enhance the capabilities of digital neutron imaging systems. Commonly used neutron scintillators are based on 6 LiF and gadolinium oxysulfide neutron converters. This work explores boron-based neutron scintillators because 10 B has a neutron absorption cross-section four times greater than 6Li, less energetic daughter products than Gd and 6 Li, and lower γ-ray sensitivity than Gd. These factors all suggest that, although borated neutron scintillators may not produce as much light as 6 Li-based screens, they may offer improved neutron statistics and spatial resolution. This work conducts a parametric study to determine the effects of various boron neutron converters, scintillator and converter particle sizes, converter-to-scintillator mix ratio, substrate materials, and sensor construction on image quality. The best performing boron-based scintillator screens demonstrated an improvement in neutron detection efficiency when compared with a common 6 LiF/ZnS scintillator, with a 125% increase in thermal neutron detection efficiency and 67% increase in epithermal neutron detection efficiency. The spatial resolution of high-resolution borated scintillators was measured, and the neutron tomography of a test object was successfully performed using some of the boron-based screens that exhibited the highest spatial resolution. For some applications, boron-based scintillators can be utilized to increase the performance of a digital neutron imaging system by reducing acquisition times and improving neutron statistics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data Visualization and Animation Lab (DVAL) overview

The general capabilities of the Langley Research Center Data Visualization and Animation Laboratory is described. These capabilities include digital image processing, 3-D interactive computer graphics, data visualization and analysis, video-rate acquisition and processing of video images, photo-realistic modeling and animation, video report generation, and color hardcopies. A specialized video image processing system is also discussed.

Stacy, Kathy↗

RapidEELS: machine learning for denoising and classification in rapid acquisition electron energy loss spectroscopy

Recent advances in detectors for imaging and spectroscopy have afforded in situ, rapid acquisition of hyperspectral data. While electron energy loss spectroscopy (EELS) data acquisition speeds with electron counting are regularly reaching 400 frames per second with near-zero read noise, signal to noise ratio (SNR) remains a challenge owing to fundamental counting statistics. In order to advance understanding of transient materials phenomena during rapid acquisition EELS, trustworthy analysis of noisy spectra must be demonstrated. In this study, we applied machine learning techniques to denoise high frame rate spectra, benchmarking with slower frame rate “ground truths”. The results provide a foundation for reliable use of low SNR data acquired in rapid, in-situ spectroscopy experiments. Such a tool-set is a first step toward both automation in microscopy as well as use of these methods to interrogate otherwise poorly understood transformations.

36 MATERIALS SCIENCE↗

Particle displacement tracking for PIV

A new Particle Imaging Velocimetry (PIV) data acquisition and analysis system, which is an order of magnitude faster than any previously proposed system has been constructed and tested. The new Particle Displacement Tracing (PDT) system is an all electronic technique employing a video camera and a large memory buffer frame-grabber board. Using a simple encoding scheme, a time sequence of single exposure images are time coded into a single image and then processed to track particle displacements and determine velocity vectors. Application of the PDT technique to a counter-rotating vortex flow produced over 1100 velocity vectors in 110 seconds when processed on an 80386 PC.

Wernet, Mark P.↗

Robust Quantitative Measurement of Flows and Transparent or Highly Reflective Objects

The liquid crystal point diffraction interferometer (LCPDI) is a new instrument that has been developed for the measurement of phase objects. The LCPDI uses the compact, robust design of Linnik's point diffraction interferometer and adds to it phase stepping capability for quantitative interferogram analysis. The result is a compact, simple to align, environmentally insensitive interferometer capable of accurately measuring optical wave-fronts. A solid state camera provides very high data density and automated data reduction. The instrument can measure either transparent objects like fluids and lenses, or highly reflective opaque objects like mirrors. In the former case, the refractive index distribution is measured and then related to various properties like temperature, density, chemical composition, or thickness. In the latter case, the measured phase distribution is related to the object shape. The objects measured must be stationary or quasisteady state because the measurement requires the acquisition of several frames of image data during which time the object's properties must not have changed. The data acquisition time depends on the speed of the frame grabber and the required number of data frames. Typically, three to five frames taking 1 to 2 seconds are required. The potential for faster data acquisition exists.

Mercer, Carolyn R.↗

Imaging Modalities Relevant to Intracranial Pressure Assessment in Astronauts: A Case-Based Discussion

Introduction: Intracranial pressure (ICP) elevation has been inferred or documented in a number of space crewmembers. Recent advances in noninvasive imaging technology offer new possibilities for ICP assessment. Most International Space Station (ISS) partner agencies have adopted a battery of occupational health monitoring tests including magnetic resonance imaging (MRI) pre- and postflight, and high-resolution sonography of the orbital structures in all mission phases including during flight. We hypothesize that joint consideration of data from the two techniques has the potential to improve quality and continuity of crewmember monitoring and care. Methods: Specially designed MRI and sonographic protocols were used to image eyes and optic nerves (ON) including the meningeal sheaths. Specific crewmembers multi-modality imaging data were analyzed to identify points of mutual validation as well as unique features of complementary nature. Results and Conclusion: Magnetic resonance imaging (MRI) and high-resolution sonography are both tomographic methods, however images obtained by the two modalities are based on different physical phenomena and use different acquisition principles. Consideration of the images acquired by these two modalities allows cross-validating findings related to the volume and fluid content of the ON subarachnoid space, shape of the globe, and other anatomical features of the orbit. Each of the imaging modalities also has unique advantages, making them complementary techniques.

Sargsyan, Ashot E.↗

An Investigation of Surge in a High-Speed Centrifugal Compressor Using Digital PIV

Compressor stall is a catastrophic breakdown of the flow in a compressor, which con lead to a loss of engine power, large pressure transients in the inlet/nacelle, and engine flameout. The implementation of active or passive strategies for controlling rotating stall and surge can significantly extend the stable operating range of a compressor without substantially sacrificing performance. It is crucial to identify the dynamic changes occurring in the flow field prior to rotating stall and surge in order to control these events successfully. Generally, pressure transducer measurements are made to capture the transient response of a compressor prior to rotating stall. In this investigation, Digital Particle Imaging Velocimetry (DPIV) is used in conjunction with dynamic pressure transducers to capture transient velocity and pressure measurements simultaneously in the nonstationary flow field during compressor surge. DPIV is an instantaneous, planar measurement technique that is ideally suited for studying transient flow phenomena in highspeed turbomachinery and has been used previously to map the stable operating point flow field in the diffuser of a high-speed centrifugal compressor. Through the acquisition of both DPIV images and transient pressure data, the time evolution of the unsteady flow during surge is revealed.

Wernet, Mark P.↗

An Investigation of Surge in a High-Speed Centrifugal Compressor Using Digital PIV

Compressor stall is a catastrophic breakdown of the flow in a compressor, which can lead to a loss of engine power, large pressure transients in the inlet/nacelle and engine flameout. The implementation of active or passive strategies for controlling rotating stall and surge can significantly extend the stable operating range of a compressor without substantially sacrificing performance. It is crucial to identify the dynamic changes occurring in the flow field prior to rotating stall and surge in order to successfully control these events. Generally, pressure transducer measurements are made to capture the transient response of a compressor prior to rotating stall. In this investigation, Digital Particle Imaging Velocimetry (DPIV) is used in conjunction with dynamic pressure transducers to simultaneously capture transient velocity and pressure measurements in the non-stationary flow field during compressor surge. DPIV is an instantaneous, planar measurement technique which is ideally suited for studying transient flow phenomena in high speed turbomachinery and has been used previously to successfully map the stable operating point flow field in the diffuser of a high speed centrifugal compressor. Through the acquisition of both DPIV images and transient pressure data, the time evolution of the unsteady flow during surge is revealed.

Wernet, Mark P.↗

Hyperspectral acquisition with ScanImage at the single pixel level: application to time domain coherent Raman imaging

We present a comprehensive strategy and its practical implementation using the commercial ScanImage software platform to perform hyperspectral point scanning microscopy when a fast time-dependent signal varies at each pixel level. In the proposed acquisition scheme, the scan along the X-axis is slowed down while the data acquisition is maintained at a high pace to enable the rapid acquisition of the time-dependent signal at each pixel level. The ScanImage generated raw 2D images have a very asymmetric aspect ratio between X and Y, the X axis encoding both for space and time acquisition. The results are X-axis macro-pixel where the associated time-dependent signal is sampled to provide hyperspectral information. We exemplified the proposed hyperspectral scheme in the context of time-domain coherent Raman imaging, where a pump pulse impulsively excites molecular vibrations that are subsequently probed by a time-delayed probe pulse. In this case, the time-dependent signal is a fast acousto-optics delay line that can scan a delay of 4.5ps in 25 μ s at each pixel level. With this acquisition scheme, we demonstrate ultra-fast hyperspectral vibrational imaging in the low frequency range [10 cm −1 , 150 cm −1 ] over a 500 μm field of view (64 x 64 pixels) in 130ms (∼ 7.5 frames/s). The proposed acquisition scheme can be readily extended to other applications requiring the acquisition of a fast-evolving signal at each pixel level.

Metais, Samuel↗

AI-enabled high-resolution scanning coherent diffraction imaging

Ptychographic imaging is a powerful means of imaging beyond the resolution limits of typical x-ray optics. Capturing recovered images from raw ptychographic data, however, requires the solution of an inverse problem, namely, phase retrieval. Phase retrieval algorithms are computationally expensive, which precludes real-time imaging. In this work, we propose PtychoNN, an approach to solve the ptychography data inversion problem based on a deep convolutional neural network. We demonstrate how the proposed method can be used to predict real-space structure and phase at each scan point solely from the corresponding far-field diffraction data. Our results demonstrate the practical application of machine learning to recover high fidelity amplitude and phase contrast images of a real sample hundreds of times faster than current ptychography reconstruction packages. Furthermore, by overcoming the constraints of iterative model-based methods, we can significantly relax sampling constraints on data acquisition while still producing an excellent image of the sample. Besides drastically accelerating acquisition and analysis, this capability has profound implications for the imaging of dose sensitive, dynamic, and extremely voluminous samples.

47 OTHER INSTRUMENTATION↗

Towards the usage of quarry blasts as an active seismic source for subsurface characterization and imaging

SUMMARY Active or man-made seismic sources are often used to delineate subsurface geological structures via seismic imaging techniques. Although conventional controlled seismic sources have provided high-resolution subsurface images, the high cost of data acquisition necessitates improved use of cheaper alternative seismic sources for subsurface imaging, such as traffic noise, quarry blasts and earthquakes. Here, we explore the potential use of quarry blasts as an active seismic source for subsurface imaging. The goal of our study is to demonstrate the utility of quarry blasts as seismic sources for investigating subsurface structure with a field experiment in Mill Creek, southern Oklahoma. We deployed a 7455-m-long receiver line of 72 receivers (105 m spacing) extending away from a quarry, with a recording time of 28 d. We analyse similarities between blasts, wave types, origin time and excitation location of quarry blasts, which is important information for using such signal as an active source. Given a relative homogeneous geological condition in the study area, we could not observe clear reflected waves. However, the use of P- and S-wave velocities led to the delineation of a major basement damage zone in the study area, which further demonstrates the viability of quarry blasts as a useful seismic source for subsurface geological imaging.

58 GEOSCIENCES↗

Real-Time, Holographic, Dynamic Image-Storage Device

Solid-state device developed for high-speed acquisition, dynamic storage, and amplification of three-dimensional holographic images. Holograms generated via four-wave mixing in two or more photorefractive crystals (or subelements of single crystal) to create single-crystal or multicrystal oscillator. Apparatus provides dynamic storage of holographic image of object after electronic shutter closed to turn off object beam. Provides capability to store, amplify, process, and transmit time-varying, two-dimensional, spatial information. Developments include sensors, actuators, and optical computers operating at speeds on order of speed of light. Potential in applications in which need for high-speed acquisition and storage of three-dimensional holographic images.

Montgomery, Raymond C.↗

Fundamental research data base

A fundamental research data base was created on a single 9-track 1600 BPI tape containing ground truth, image, and Badhwar profile feature data for 17 North Dakota, South Dakota, and Minnesota agricultural sites. Each site is 5x6 nm in area. Image data has been provided for a minimum of four acquisition dates for each site. All four images have been registered to one another. A list of the order of the files on tape and the dates of acquisition is provided.

Source record↗

iSHELL: a 1–5 micron R = 80,000 Immersion Grating Spectrograph for the NASA Infrared Telescope Facility

iSHELL is a 1.06–5.3 μm high spectral resolution spectrograph built for the 3.2 m NASA Infrared Telescope Facility (IRTF) on Maunakea, Hawaii. Dispersion is accomplished with a silicon immersion grating in order to keep the instrument small enough to be mounted at the Cassegrain focus of the telescope. The white pupil spectrograph produces resolving powers of up to about R ≡ λ/δλ = 80,000 (0."375 slit). Cross-dispersing gratings mounted in a tiltable mechanism allow observers to select different wavelength ranges and, in combination with a slit wheel and Dekker mechanism, slit widths ranging from 0."375 to 4."0 and slit lengths ranging from 5" to 25". One Teledyne 2048 × 2048 HAWAII-2RG array is used in the spectrograph, and one Raytheon 512 × 512 Aladdin 2 array is used in a 1–5 μm slit viewer for object acquisition, guiding, and scientific imaging. iSHELL has been in productive regular use on IRTF since first light in 2016 September. In this paper we discuss details of the science case, design, construction and astronomical use of iSHELL.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantitative order-parameter measurement in lattice-mismatched AlInP using precession electron diffraction

Precession electron diffraction (PED) was used to measure the long-range order parameter in lattice-mismatched AlInP epitaxial films under investigation for solid-state-lighting applications. Both double- and single-variant films grown at 620, 650, and 680°C were analyzed in TEM cross-section. PED patterns were acquired in selected-area-diffraction mode through external microscope control using serial acquisition, which allows inline image processing. The integrated peak intensities from experimental patterns were fit using dynamical simulations of diffraction from the ordered domain structures. Included in the structure-factor calculations were mean atomic displacements of the anions (P) due to ordering, which were found by valence-force-field calculations to have a nearly linear dependence on order parameter. A maximum order parameter of S = 0.36 was measured for a double-variant specimen grown at 650°C.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Total internal reflection enabled wide-field coherent anti-Stokes Raman scattering microscopy

Wide-field coherent anti-Stokes Raman scattering (CARS) microscopy offers an attractive means for the rapid and simultaneous acquisition of vibrationally resolved images across a large field of view. A major challenge in the implementation lies in how to achieve sufficiently strong excitation fields necessary to drive the third-order optical responses over the large focal region. Here, we report a new wide-field CARS microscope enabled by a total internal reflection excitation scheme using a femtosecond Ti:Sapphire oscillator to generate pump and broadband near-infrared Stokes pulses. The spectrally broad Stokes pulse, in combination with its inherent chirp, offers not only access to a wide range of Raman modes spanning ∼ <#comment/> 1000 to ∼ <#comment/> 3500 c m − <#comment/> 1 but also a straightforward means to select vibrational transitions within this range by simply varying the time delay between the pulses. The unique capabilities of this wide-field CARS microscope were validated by acquiring high-quality CARS images from the model and complex biological samples on conventional microscope coverslips.

Doughty, Benjamin (ORCID:0000000164299329)↗

NASA's 91-cm. airborne telescope

The Gerard P. Kuiper Airborne Observatory (KAO), commissioned in May 1975, is the result of the multi-year NASA program of infrared observations from high-flying aircraft. The KAO is a highly modified Lockheed C-141 jet transport, equipped with a 91-cm bent-Cassegrain telescope, as an international facility for research in infrared astronomy. To minimize the effects of aircraft vibration, the telescope is mounted on four pneumatic shock absorbers, and the entire assembly is balanced on the side of a spherical compressed-air bearing, containing a 0.018 mm-thick air film under a pressure of 19 atmospheres. The use of the KAO is not limited to infrared research, its total observable wavelength band extending from the near UV (3000 A) to the millimeter region. Design and technical characteristics of the telescope are discussed, including the image stabilization and target acquisition systems, as well as observational results obtained during the first year of the KAO operation.

Cameron, R. M.↗