Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high resolution spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

High spectral resolution reflectance spectroscopy of minerals

The reflectance spectra of minerals are studied as a function of spectral resolution in the range from 0.2 to 3.0 microns. Selected absorption bands were studied at resolving powers as high as 2240. At resolving powers of approximately 1000, many OH-bearing minerals show diagnostic sharp absorptions at the resolution limit. At low resolution, some minerals may not be distinguishable, but as the resolution is increased, most can be easily identified. As the resolution is increased, many minerals show fine structure, particularly in the OH-stretching overtone region near 1.4 micron. The fine structure can enhance the ability to discriminate between minerals, and in some cases the fine structure can be used to determine elemental composition.

Clark, Roger N.↗

SPDE: Solar Plasma Diagnostic Experiment

The physics of the Solar corona is studied through the use of high resolution soft x-ray spectroscopy and high resolution ultraviolet imagery. The investigation includes the development and application of a flight instrument, first flown in May, 1992 on NASA sounding rocket 36.048. A second flight, NASA founding rocket 36.123, took place on 25 April 1994. Both flights were successful in recording new observations relevant to the investigation. The effort in this contract covers completion of the modifications to the existing rocket payload, its reflight, and the preliminary day reduction and analysis. Experience gained from flight 36.048 led us to plan several payload design modifications. These were made to improve the sensitivity balance between the UV and EUV spectrographs, to improve the scattered light rejection in the spectrographs, to protect the visible light rejection filter for the Normal Incidence X-ray Imager instrument (NIXI), and to prepare one new multilayer mirror coating to the NIXI. We also investigated the addition of a brassboard CCD camera to the payload to test it as a possible replacement for the Eastman type 101-07 film used by the SPDE instruments. This camera was included in the experimeter's data package for the Project Initiation Conference for the flight of NASA Mission 36.123, held in January, 1994, but for programmatic reasons was deleted from the final payload configuration. The payload was shipped to the White Sands Missile Range on schedule in early April. The launch and successful recovery took place on 25 April, in coordination with the Yohkoh satellite and a supporting ground-based observing campaign.

Bruner, Marilyn E.↗

High-Resolution Photoelectron Imaging and Photodetachment Spectroscopy of Cryogenically Cooled IO –

We report a high-resolution photoelectron imaging and photodetachment spectroscopy study of cryogenically-cooled IO - . The high-resolution photoelectron spectra yield a more accurate electron affinity (EA) of 2.3805(5) eV for IO, as well as a more accurate spin-orbit splitting energy between the 2 Π 3/2 and 2 Π 1/2 states of IO as 2093(5) cm -1 . Photodetachment spectroscopy confirmed several excited states for the IO - anion predicted by theoretical calculations, including two valence-type excited states, the repulsive 3 Π state and a shallow bound 1 Π state. More interestingly, we have observed two vibrational resonances which are proposed to be due to a dipole-induced resonant state, about 230 cm -1 above the detachment threshold of IO - .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High Resolution UV Emission Spectroscopy of Molecules Excited by Electron Impact

Photodissociation via discrete line absorption into predissociating Rydberg and valence states is the dominant destruction mechanism of CO and other molecules in the interstellar medium and molecular clouds. Accurate values for the rovibronic oscillator strengths of these transitions and predissociation yields of the excited states are required for input into the photochemical models that attempt to reproduce observed abundances. We report here on our latest experimental results of the electron collisional properties of CO and N2 obtained using the 3-meter high resolution single-scattering spectroscopic facility at JPL.

James, G. K.↗

Hot Spot Evolution Measured by High-Resolution X-Ray Spectroscopy at the National Ignition Facility

Evolution of the hot spot plasma conditions was measured using high-resolution x-ray spectroscopy at the National Ignition Facility. The capsules were filled with DD gas with trace levels of Kr and had either a high-density-carbon (HDC) ablator or a tungsten (W)-doped HDC ablator. Time-resolved measurement of the Kr He β spectra, absolutely calibrated by a simultaneous time-integrated measurement, allows inference of the electron density and temperature through observing Stark broadening and the relative intensities of dielectronic satellites. By matching the calculated hot spot emission using a collisional-radiative code to experimental observations, the hot spot size and areal density are determined. Here these advanced spectroscopy techniques further reveal the effect of W dopant in the ablator on the hot spot parameters for their improved implosion performance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-resolution extreme-ultraviolet spectroscopy of potassium using anti-Stokes radiation

The use of a new extreme-ultraviolet radiation source based on spontaneous anti-Stokes scattering for high-resolution absorption spectroscopy of transition originating from the 3p6 shell of potassium is reported. The region from 546.6 to 536.8 A is scanned at a resolution of about 1.2 Kayser. Within this region, four previously unreported lines are observed.

Rothenberg, J. E.↗

The Space Infrared Interferometric Telescope (SPIRIT): High-resolution Imaging and Spectroscopy in the Far-infrared

We report results of a recently-completed study of SPIRIT, a candidate NASA Origins Probe. SPIRIT is a spatial and spectral interferometer with an operating wavelength range 25 - 400 microns. SPIRIT will provide sub-arcsecond resolution images and spectra with resolution R = 3000 in a 1 arcmin field of view to accomplish three primary scientific objectives: (1) Learn how planetary systems form from protostellar disks, and how they acquire their chemical organization; (2) Characterize the family of extrasolar planetary systems by imaging the structure in debris disks to understand how and where planets form, and why some planets are ice giants and others are rocky; and (3) Learn how high-redshift galaxies formed and merged to form the present-day population of galaxies. Observations with SPIRIT will be complementary to those of the James Webb Space Telescope and the ground-based Atacama Large Millimeter Array. All three observatories could be operational contemporaneously. SPIRIT will pave the way to the 1 km maximum baseline interferometer known as the Submillimeter Probe of the Evolution of Cosmic Structure (SPECS). In addition to the SPIRIT mission concept, this talk will emphasize the importance of dense u-v plane coverage and describe some of the practical considerations associated with alternative interferometric baseline sampling schemes.

Leisawitz, D,↗

The gas environment of the young stellar object GL 2591 studied by infrared spectroscopy

High-resolution M band (4.6 microns) spectroscopy of GL 2591 is presented. Physical structures noted include an absorption feature with an outflow velocity of about 17 km/s, cold gas (identified with the core of the molecular cloud within which the object is embedded), and very broad C-12O lines formed in a neutral wind. The detection of hot low-velocity gas together with warm high-velocity gas suggests the scenario of a warm neutral wind accelerating from an accretion disk.

Mitchell, George F.↗

High-resolution vibrational predissociation spectroscopy of I - ·H 2 O by single-mode CW infrared excitation in a 3D cryogenic ion trap

We describe the integration of a tunable, single-mode, continuous wave infrared laser into a cryogenic ion spectroscopy experiment to measure the rovibrational spectrum of the I - ∙H 2 O complex in the OH stretching region. These upper levels lie about 300 cm -1 above the dissociation threshold. The measurements are carried out by loading the ions in a radiofrequency ion trap at 10 Hz and cooling them to 5 K with pulsed He buffer gas. IR photodissociation (PD) of the I - ∙H 2 O complex is monitored by recording the I - product yield by time-of-flight mass spectrometry as a function of laser wavelength. Very narrow (Δν~75 MHz) rotational lines are observed throughout the spectrum, indicating long (ca. 2 ns) lifetimes for the excited metastable rovibrational levels. Rotational analysis of the band arising from the K”=1 to K’=2 transition of the free OH stretching fundamental yields the structure of the complex for the first time. Over 50% of the trapped ion ensemble in the trap can be photodissociated upon excitation of a single rotational line. This enables very high signal-to-noise in the PD spectrum, and is traced to a mechanism in which the ground state rotational levels are rapidly equilibrated by collisions with the buffer gas.

74 ATOMIC AND MOLECULAR PHYSICS↗

Near-Monochromatic Tuneable Cryogenic Niobium Electron Field Emitter

We report creating, manipulating, and detecting coherent electrons is at the heart of future quantum microscopy and spectroscopy technologies. Leveraging and specifically altering the quantum features of an electron beam source at low temperatures can enhance its emission properties. Here, we describe electron field emission from a monocrystalline, superconducting niobium nanotip at a temperature of 5.9 K. The emitted electron energy spectrum reveals an ultranarrow distribution down to 16 meV due to tunable resonant tunneling field emission via localized band states at a nanoprotrusion’s apex and a cutoff at the sharp low-temperature Fermi edge. This is an order of magnitude lower than for conventional field emission electron sources. The self-focusing geometry of the tip leads to emission in an angle of 3.7°, a reduced brightness of 3.8 × 10 8 A/(m 2 srV), and a stability of hours at 4.1 nA beam current and 69 meV energy width. This source will decrease the impact of lens aberration and enable new modes in low-energy electron microscopy, electron energy loss spectroscopy, and high-resolution vibrational spectroscopy.

36 MATERIALS SCIENCE↗

High Resolution Fission Fragment Spectroscopy with Superconducting Microcalorimeters

Sub-1 AMU mass determination is important for determining fission yields and neutron multiplicity, which are necessary inputs for fission models. Fission models can improve spent nuclear waste stream analysis and nuclear fuel burnup determination. Here, to achieve this goal, we have used superconducting microcalorimeter detectors to directly measure the energy of fission fragments from the spontaneous fission of 252 Cf. With a fiber coupled LED pulser setup we demonstrate that we can reach a relative energy resolution of 0.1% and better for photon pulses with energies above 60 MeV. This instrument, in conjunction with time-of-flight (TOF) measurement, would allow for sub-1 atomic mass unit (AMU) mass determination of fission fragments in a future beamline application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High resolution threshold photoelectron spectroscopy by electron attachment

A system is provided for determining the stable energy levels of a species ion, of an atomic, molecular, or radical type, by application of ionizing energy of a predetermined level, such as through photoionization. The system adds a trapping gas to the gaseous species to provide a technique for detection of the energy levels. The electrons emitted from ionized species are captured by the trapping gas, only if the electrons have substantially zero kinetic energy. If the electrons have nearly zero energy, they are absorbed by the trapping gas to produce negative ions of the trapping gas that can be detected by a mass spectrometer. The applied energies (i.e. light frequencies) at which large quantities of trapping gas ions are detected, are the stable energy levels of the positive ion of the species. SF6 and CFCl3 have the narrowest acceptance bands, so that when they are used as the trapping gas, they bind electrons only when the electrons have very close to zero kinetic energy.

Chutjian, A.↗

High-resolution laser absorption spectroscopy of ozone near 1129.4 cm (-1)

A Beer's Law experiment was performed with a tunable diode laser to determine self broadened line shape parameters of one infrared absorption ozone line in the nu1 band for ten pressures from 0.26 to 6.29 torr at 285 K. The SO2 line positions were used for wavelength calibration. Line shapes were iteratively fitted to the Voigt function at a Doppler width of 29.54 MHz (HWHM) resulting in values for the integrated line strength, (S), of (0.144 +/- 0.007) x 10 to the minus 20th/cm molecule/cu cm, line center frequency, nu sub o, of 1129.426/cm and the Lorentzian contributions to halfwidth. A linear least squares fit of (alpha sub L)5 as a function of pressure yielded a zero intercept of 15.27 +/- 0.29 MHz (rho = 0.99) and a broadening parameter, (alpha sub L)5, of 5.71 +/- 0.29 MHz/Torr. This results in a line width (FWHM) of 0.144 +/- .007/cm at 760 torr and 285 K.

Majorana, L. N.↗

High-resolution Fourier transform spectroscopy of the Meinel system of OH

The infrared spectrum of the hydroxyl radical OH, between 1850 and 9000/cm has been measured with a Fourier transform spectrometer. The source, a hydrogen-ozone diffusion flame, was designed to study the excitation of rotation-vibration levels of the OH Meinel bands under conditions similar to those in the upper atmosphere which produce the nighttime OH airglow emission. Twenty-three bands were observed: nine bands in the Delta upsilon = 1 sequence, nine bands in the Delta upsilon = 2 sequence, and five bands in the Delta upsilon = 3 sequence. A global nonlinear least-squares fit of 1696 lines yielded molecular parameters with a standard deviation of 0.003/cm. Term values are computed, and transition frequencies in the Delta upsilon = 3, 4, 5, 6 sequences in the near-infrared are predicted.

Abrams, Mark C.↗