Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating capacity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Encapsulated Nanoparticle Synthesis and Characterization for Improved Storage Fluids: Preprint

Nanoparticles are typically composed of 50--500 atoms and exhibit properties that are significantly different from the properties of larger, macroscale particles that have the same composition. The addition of these particles to traditional fluids may improve the fluids' thermophysical properties. As an example, the addition of a nanoparticle or set of nanoparticles to a storage fluid may doubleits heat capacity. This increase in heat capacity would allow a sensible thermal energy storage system to store the same amount of thermal energy in half the amount of storage fluid. The benefit is lower costs for the storage fluid and the storage tanks, resulting in lower-cost electricity. The goal of this long-term research is to create a new class of fluids that enable concentrating solarpower plants to operate with greater efficiency and lower electricity costs. Initial research on this topic developed molecular dynamic models that predicted the energy states and transition temperatures for these particles. Recent research has extended the modeling work, along with initiating the synthesis and characterization of bare metal nanoparticles and metal nanoparticles that areencapsulated with inert silica coatings. These particles possess properties that make them excellent candidates for enhancing the heat capacity of storage fluids.

14 SOLAR ENERGY↗

Cost-Optimized Cold Climate Heat Pump Development and Field Test

Cold climate heat pumps (CCHPs) expand the heat pump market to climates where heating demand is dominant. They can achieve more than 70% energy savings compared with electric resistance heating and operate at lower cost than using tank-stored propane to fuel a furnace. A high-efficiency heat pump with a heating seasonal performance factor (HSPF)—as defined by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI 2008)—greater than 10.0 would be more efficient than gas heating in terms of source energy. However, developing a cost-effective CCHP involves some challenges. A typical single-speed, air-source heat pump (ASHP) with an HSPF of 7.7 Btu/Wh does not work well under cold outdoor temperature conditions typical of cold climate locations for four major reasons: 1. Discharge temperature is too high—The low suction pressure and high compression pressure ratio at low ambient temperatures causes high compressor discharge temperatures in excess of the maximum limit for many of the compressors on the market. Furthermore, system charge of a heat pump is usually optimized in the cooling mode, which leads to overcharge conditions in the heating mode, further increasing the discharge temperature. 2. Heating capacity is insufficient if sized to meet the building design cooling load— Heating capacity of a single-speed heat pump decreases with ambient temperature. The heating capacity at -13°F (-25°C) typically decreases to 20%–40% of the rated heating capacity at 47°F (8.3°C) (~equivalent to the rated cooling capacity at 95°F [35°C]). Therefore, a single-speed heat pump, typically sized to match the building design cooling load, cannot provide adequate heating capacity to match the building heating load at low ambient temperatures. The capacity deficit is filled by inefficient resistance heat, thus lowering the system efficiency and significantly increasing power demand. 3. Cyclic loss is significant if sized to meet the building design heating load—If a single-speed heat pump is sized to meet the heating load, it will be significantly oversized relative to the cooling load in many cold climates. This will cause excessive on/off cyclic loss during the cooling and heating operations at moderately low ambient temperatures. Thus, capacity modulation capability (e.g., using a variable-speed or multi-stage compressor) is necessary for a CCHP, which uses its full capacity to meet the peak heating load and partial capacity to meet the cooling and part-load heating loads. 4. Coefficient of performance (COP) is low—Heating COP degrades significantly at low ambient temperatures owing to the large temperature difference between the heat source and sink. A target CCHP should be sized to meet the building design heating load while minimizing the cyclic loss for the cooling and heating operations at moderate ambient temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Suitable low Global Warming Potential (GWP) refrigerants for two-speed Heat Pumps for residential applications based on speed Heat Pumps for residential applications based on simulated performance simulated performance

Cold climate Heat Pumps (CCHPs) using single-speed compressors in tandem have been successfully built and tested to reach its performance metrics with outdoor temperatures as low as -25°C. CCHPs must be designed to alleviate the problems of too high discharge temperatures, low suction pressure and high-pressure ratio at low ambient conditions and insufficient heating capacity relative to the heating capacity at 8.3°C. In this paper we recognize those concerns. Low-GWP refrigerants are screened based on the shape of their T-S saturation boundary. Simulations of the performance of low-GWP refrigerants (R32, R454B, R466A, and R452B) relative to R410A is done using the DOE/ORNL Heat Pump Design Model at the component level. Systemic inefficiency, the root cause of lost work, is addressed by component-level exergy analysis to refine design options. CCHPs using low-GWP refrigerants addresses issues of reducing energy consumption, lowering carbon footprint, and enabling environmentally sustainability. The CCHP was designed to meet a HSPF > 11.0 and SEER > 15.0 having adequate heat pump heating capacity down to -25°C. It is estimated that at least 2.6 million U.S homes using electric furnaces and heat pumps in cold or very old climates with an annual energy consumption of 0.17EJ would benefit by CCHPs.

Ally, Moonis↗

THE POTENTIAL OF NANOPARTICLE ENHANCED IONIC LIQUIDS (NEILS) AS ADVANCED HEAT TRANSFER FLUIDS

Interest in capturing the energy of the sun is rising as demands for renewable energy sources increase. One area of developing research is the use of concentrating solar power (CSP), where the solar energy is concentrated by using mirrors to direct the sunlight towards a collector filled with a heat transfer fluid (HTF). The HTF transfers the collected energy into pressurized steam, which is used to generate energy. The greater the energy collected by the HTF, the more efficent the electrical energy production is, thus the overall efficiency is controlled by the thermal fluid. Commercial HTFs such as Therminol{reg_sign} (VP-1), which is a blend of biphenyl and diphenyl oxide, have a significant vapor pressure, especially at elevated temperatures. In order for these volatile compounds to be used in CSP systems, the system either has to be engineered to prevent the phase change (i.e., volatilization and condensation) through pressurization of the system, or operate across the phase change. Over thirty years ago, a class of low-melting organic compounds were developed with negligible vapor pressure. These compounds are referred to as ionic liquids (ILs), which are organic-based compounds with discrete charges that cause a significant decrease in their vapor pressure. As a class, ILs are molten salts with a melting point below 100 C and can have a liquidus range approaching 400 C, and in several cases freezing points being below 0 C. Due to the lack of an appreciable vapor pressure, volatilization of an IL is not possible at atmospheric pressure, which would lead to a simplification of the design if used as a thermal fluid and for energy storage materials. Though the lack of a vapor pressure does not make the use of ILs a better HTF, the lack of a vapor pressure is a compliment to their higher heat capacity, higher volummetric density, and thus higher volumetric heat capacity. These favorable physical properties give ILs a pontential advantage over the current commerically used thermal fluids. Also within the past decade nanofluids have gained attention for thermal conductivity enhancment of fluids, but little analysis has been completed on the heat capacity effects of the nanoparticle addition. The idea of ILs or nanofluids as a HTF is not new, as there are several references that have proposed the idea. However, the use of ionic liquid nanofluids containing nanomaterials other than carbon nanotubes has never before been studied. Here, for the first time, nano-particle enhanced ILs (NEILs) have been shown to increase the heat capacity of the IL with no adverse side effects to the ILs thermal stability and, only at high nanoparticle loading, are the IL physical properties affected. An increase of volumetric heat capacity translates into a better heat transfer fluid as more energy is stored per volumetric unit in the solar concentrating section, thus more efficency in increased steam pressure. Results show that the properties of the NEIL are highly dependant on the suspended nanomaterial and careful materials selection is required to fully optimize the nanofluid properties.

14 SOLAR ENERGY↗

Bulk thermal capacity determination for Li/BCX and Li/SOClN2 cells

The bulk heat capacities of Li/BCX and Li/SOClN2 cells were determined at 0 and 100 percent depth-of-discharge for 2.0 V cut-off voltage, in the temperature range 0 to 60 C by a method that did not involve the destruction of the cell nor the contact of cell with a liquid. The heat capacities are found to be dependent on state-of-charge, increasing with depth-of-discharge. The Li/BCX DD-cell has a lower heat capacity than a high rate Li/SOCl2 D-cell. The results obtained by this method compare favorably well with results reported in the literature through other methods. The bulk heat capacities of the cells did not change significantly in the temperature range 0 to 60 C.

Kalu, E. E.↗

Next steps in high-repetition-rate laser development for Thomson scattering

Design of a next generation high-rep-rate laser system is underway, aiming for a maximum rep rate of 100 kHz for 1 ms. This will be a "pulse-burst" laser, which is a type of heat-capacity laser. Heat-capacity laser operation is characterized by a burst of pulses of limited duration, with burst length ≤100 ms and pulse rep rate ≥1 kHz. Waste heat accumulates in the laser rod during the burst. This heat is deposited evenly throughout the rod volume, with very little heat removed during the burst, such that temperature rises evenly across the rod radius. Thus beam distortion due to thermal gradients is small. Heat is removed from the rod after the burst, with typically tens of seconds between bursts. Pulse-burst operation of flashlamp pumped Nd:YAG lasers is a cost-effective route to high-rep-rate capability. Pulse-burst laser systems with "fast burst" rep rates in the range of 10–20 kHz have been built for the Thomson scattering diagnostics on MST, NSTX-U, and LHD. For Thomson scattering diagnostic application, the typical requirements are 1064 nm, 1–2 J/pulse, ≤30 ns FWHM pulse, with a top-hat beam profile. A major requirement for this next generation laser system is flexibility in burst sequence programs, ranging from 1 kHz for 100 ms to 100 kHz for 1 ms, and a variety of scenarios in between so that operation can be tailored to plasma experiment requirements. Flashlamp pumping will be used for this next generation laser because it is inexpensive and flexible. A new switch-regulated flashlamp driver will provide improved flashlamp control at lower cost. Additional design issues such as the optimum flashlamp pumping spectrum and optimum Nd doping will be addressed. The use of commercial off-the-shelf components will be maximized in this laser system so that pulse-burst systems can be developed and built by others for new applications.

47 OTHER INSTRUMENTATION↗

Performance Modeling of a Thermoelectric Heat Pump Clothes Dryer with Very High Air Flow

Previous research has shown that a clothes dryer heated by thermoelectric (Peltier) heat pumps can be up to 85% more efficient than a conventional electric-resistance dryer. A previous thermoelectric prototype used a conventional dryer’s air flow of 120 ft3/min (0.06 m3/s) and provided about 1,300 W of thermoelectric heating capacity at a heating coefficient of performance (COP) of approximately 1.2. In this work, the performance of a clothes dryer with a very high air flow rate, up to 300 ft3/min (1.14 m3/s), and only 400 W of thermoelectric heating capacity was investigated using a thermohydraulic model. Key aspects of the model were validated experimentally. Results for dry time and efficiency are presented for various air flow and heating rates.

Boudreaux, Philip↗

Material Properties from ab initio Calculations [Slides]

Summary and Future Direction: Diffusion coefficients - Calculated and compared with experimental viscosity; More work on solid state diffusion coefficients. Heat capacity - Calculated and compared with Ce heat capacity; Need to calculate the solid heat capacity and find more experimental data. Heat of formation - Calculated for one and two Ce atoms; Slab calculations are under way for a surface. Reaction rate - Calculation of a single Ce atom reaction is in progress; Simulations of larger clusters for comparison with ionic reaction experiments. Emissivity and Thermal Conductivity - Single snapshot calculated; Averaging over ionic configurations at different T is in progress.

36 MATERIALS SCIENCE↗

Thermodynamic modeling of MDEA(aq)-NH 3 (aq)-K 2 CO 3 (aq)-CO 2 (aq) using the Extended UNIQUAC model

Here, the development of advanced processes for carbon dioxide capture requires reliable thermodynamic models to ensure accurate process design. This work presents an optimized parameter set of the Extended UNIQUAC model for advanced mixed solvent solutions containing CO 2 -MDEA-NH 3 -K 2 CO 3 in water. The model was parameterized using vapor–liquid equilibrium, pure component saturation pressure, excess enthalpy, heat of absorption, molar heat capacity, apparent molar heat capacity, and solid–liquid equilibrium. These thermal and equilibrium properties cover temperatures between 253.6 K to 600 K and pressures up to 75.6 bar. The current model represents an extension of previous versions that were suitable for modeling aqueous NH 3 and K 2 CO 3 solutions. This parametrization accounts for molecular interactions between MDEA and these two components, which allows for the design of advanced capture processes. This paper demonstrates that the new model parameters are valid within the range of operational conditions typically found in CO 2 capture processes.

42 ENGINEERING↗

Inter-phase heat transfer and energy coupling in turbulent dispersed multiphase flows

Here, the present paper addresses important fundamental issues of inter-phase heat transfer and energy coupling in turbulent dispersed multiphase flows through scaling analysis. In typical point-particle or two-fluid approaches, the fluid motion and convective heat transfer at the particle scale are not resolved and the momentum and energy coupling between fluid and particles are provided by proper closure models. By examining the kinetic energy transfer due to the coupling forces from the macroscale to microscale fluid motion, closure models are obtained for the contributions of the coupling forces to the energy coupling. Due to the inviscid origin of the added-mass force, its contribution to the microscale kinetic energy does not contribute to dissipative transfer to fluid internal energy as was done by the quasi-steady force. Time scale analysis shows that when the particle is larger than a critical diameter, the diffusive-unsteady kernel decays at a time scale that is smaller than the Kolmogorov time scale. As a result, the computationally costly Basset-like integral form of diffusive-unsteady heat transfer can be simplified to a non-integral form. Conventionally, the fluid-to-particle volumetric heat capacity ratio is used to evaluate the relative importance of the unsteady heat transfer to the energy balance of the particles. Therefore, for gas-particle flows, where the fluid-to-particle volumetric heat capacity ratio is small, unsteady heat transfer is usually ignored. However, the present scaling analysis shows that for small fluid-to-particle volumetric heat capacity ratio, the importance of the unsteady heat transfer actually depends on the ratio between the particle size and the Kolmogorov scale. Furthermore, the particle mass loading multiplied by the heat capacity ratio is usually used to estimate the importance of the thermal two-way coupling effect. Through scaling argument, improved estimates are established for the energy coupling parameters of each energy exchange mechanism between the phases.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluating the Conservation of Energy Variables in Simulations of Deep Moist Convection

Abstract It is often assumed in parcel theory calculations, numerical models, and cumulus parameterizations that moist static energy (MSE) is adiabatically conserved. However, the adiabatic conservation of MSE is only approximate because of the assumption of hydrostatic balance. Two alternative variables are evaluated here: MSE − IB and MSE + KE, wherein IB is the path integral of buoyancy ( B ) and KE is kinetic energy. Both of these variables relax the hydrostatic assumption and are more precisely conserved than MSE. This article quantifies the errors that result from assuming that the aforementioned variables are conserved in large-eddy simulations (LES) of both disorganized and organized deep convection. Results show that both MSE − IB and MSE + KE better predict quantities along trajectories than MSE alone. MSE − IB is better conserved in isolated deep convection, whereas MSE − IB and MSE + KE perform comparably in squall-line simulations. These results are explained by differences between the pressure perturbation behavior of squall lines and isolated convection. Errors in updraft B diagnoses are universally minimized when MSE − IB is assumed to be adiabatically conserved, but only when moisture dependencies of heat capacity and temperature dependency of latent heating are accounted for. When less accurate latent heat and heat capacity formulae were used, MSE − IB yielded poorer B predictions than MSE due to compensating errors. Our results suggest that various applications would benefit from using either MSE − IB or MSE + KE instead of MSE with properly formulated heat capacities and latent heats.

54 ENVIRONMENTAL SCIENCES↗

Thermal properties of simulated Hanford waste glasses

Abstract The Hanford Tank Waste Treatment and Immobilization Plant will vitrify the mixed hazardous wastes generated from 45 years of plutonium production at the Hanford Site in Washington State. The molten glasses will be poured into stainless steel containers or canisters and subsequently cooled for storage and disposal. For appropriate facility design and operations to handle such highly energy‐consuming processes, knowledge of the material properties is required. The thermal properties (heat capacity, thermal diffusivity, and thermal conductivity) of representative high‐level and low‐activity waste glasses were studied as functions of temperature in the range of 200°C‐800°C (relevant to the cooling process). Simultaneous differential scanning calorimetry‐thermal gravimetry (DSC‐TGA), Xe‐flash diffusivity, pycnometry, and dilatometry were implemented. The study showed that simultaneous DSC‐TGA would be a reliable method for obtaining the heat capacity of various glasses in the temperature range of interest. Accurate thermal properties from this study were shown to provide a more realistic guideline for capacity and time constraints of the heat removal process when compared to the original conservative design‐basis engineering estimates. The estimates, though useful for design in the absence of measured physical properties, can now be supplanted and the measured thermal properties can be used in design verification activities.

Rodriguez, Carmen P.↗

Particle-number conservation in static-path approximation for thermal superfluid systems

By applying particle-number projection to the static-path approximation (SPA), the heat capacity and the breakdown of pairing correlations are investigated in the thermally excited, superfluid systems {sup 172}Yb, {sup 94}Mo, and {sup 56}Fe. For the heavy nucleus {sup 172}Yb, the heat capacities in both the SPA and the number-projected SPA (NPSPA) exhibit an S shape; the difference between the SPA and NPSPA heat-capacity curves is not very large and the particle-number projection thereby enhances the S shape already seen in the SPA. The temperature at which the S-shape of heat capacity curve occurs parallels the temperature of the breakdown of pairing correlations as indicated by the effective pairing gap. However, for the comparatively lighter nuclei {sup 94}Mo and {sup 56}Fe, the SPA does not produce an S-shaped heat capacity on its own; only after particle-number projection the S shape appears in the heat-capacity curve. For {sup 94}Mo, we compare the NPSPA result with thermal odd-even mass differences, which are regarded as a direct measure of the pairing gap.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Excess entropy and crystallization in Stillinger-Weber and Lennard-Jones fluids

Molecular dynamics simulations are used to contrast the supercooling and crystallization behaviour of monatomic liquids that exemplify the transition from simple to anomalous, tetrahedral liquids. As examples of simple fluids, we use the Lennard-Jones (LJ) liquid and a pair-dominated Stillinger-Weber liquid (SW{sub 16}). As examples of tetrahedral, water-like fluids, we use the Stillinger-Weber model with variable tetrahedrality parameterized for germanium (SW{sub 20}), silicon (SW{sub 21}), and water (SW{sub 23.15} or mW model). The thermodynamic response functions show clear qualitative differences between simple and water-like liquids. For simple liquids, the compressibility and the heat capacity remain small on isobaric cooling. The tetrahedral liquids in contrast show a very sharp rise in these two response functions as the lower limit of liquid-phase stability is reached. While the thermal expansivity decreases with temperature but never crosses zero in simple liquids, in all three tetrahedral liquids at the studied pressure, there is a temperature of maximum density below which thermal expansivity is negative. In contrast to the thermodynamic response functions, the excess entropy on isobaric cooling does not show qualitatively different features for simple and water-like liquids; however, the slope and curvature of the entropy-temperature plots reflect the heat capacity trends. Two trajectory-based computational estimation methods for the entropy and the heat capacity are compared for possible structural insights into supercooling, with the entropy obtained from thermodynamic integration. The two-phase thermodynamic estimator for the excess entropy proves to be fairly accurate in comparison to the excess entropy values obtained by thermodynamic integration, for all five Lennard-Jones and Stillinger-Weber liquids. The entropy estimator based on the multiparticle correlation expansion that accounts for both pair and triplet correlations, denoted by S{sub trip}, is also studied. S{sub trip} is a good entropy estimator for liquids where pair and triplet correlations are important such as Ge and Si, but loses accuracy for purely pair-dominated liquids, like LJ fluid, or near the crystallization temperature (T{sub thr}). Since local tetrahedral order is compatible with both liquid and crystalline states, the reorganisation of tetrahedral liquids is accompanied by a clear rise in the pair, triplet, and thermodynamic contributions to the heat capacity, resulting in the heat capacity anomaly. In contrast, the pair-dominated liquids show increasing dominance of triplet correlations on approaching crystallization but no sharp rise in either the pair or thermodynamic heat capacities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development and Testing of an Advanced Cascaded Thermoelectric Residential Heat Pump

Electricity-driven heat pumps using vapor compression cycle are an energy-efficient solution to replace fossil fuel burning and reduce greenhouse gas emissions for space heating in residential buildings. However, heating capacity and Coefficient of Performance (COP) of heat pumps degrade significantly with increasing temperature difference between ambient and indoor environments. Residents and building owners are hence reluctant to fully embrace electric heat pumps. The use of conventional all-electric heat pumps also causes concern for electric utilities due to an increased winter peak demand arising from the use of supplemental electric resistance heaters. Our research is an attempt to alleviate these concerns by designing and laboratory testing a thermoelectric (TE) heat pump cascaded with a vapor compression cycle to enhance heating capacity and COP. TE modules increase the subcooling in the refrigerant liquid of the vapor compression cycle to enlarge the evaporating capacity and works at an efficiency greater than a conventional electric resistance strip. This results in a simple, affordable, efficient and highly controllable solution to adequately meet space heating needs in dwellings. The laboratory testing of the 3-stage cascaded TE heat pump performed in this research has exhibited a higher heating capacity by above 15%, while maintaining a heating COP of 2.0-3.6 in the ambient temperature range of -18˚C to 8˚C (0˚F to 47 ˚F), which represents more than 60% of winter temperatures observed in US. If successfully commercialized, this technology can advance space-heating electrification by overcoming consumer cost barrier of heat pumps.

Shen, Bo↗

Superconducting Hot-Electron Submillimeter-Wave Detector

A superconducting hot-electron bolometer has been built and tested as a prototype of high-sensitivity, rapid-response detectors of submillimeter-wavelength radiation. There are diverse potential applications for such detectors, a few examples being submillimeter spectroscopy for scientific research; detection of leaking gases; detection of explosive, chemical, and biological weapons; and medical imaging. This detector is a superconducting-transition- edge device. Like other such devices, it includes a superconducting bridge that has a low heat capacity and is maintained at a critical temperature (T(sub c)) at the lower end of its superconducting-transition temperature range. Incident photons cause transient increases in electron temperature through the superconducting-transition range, thereby yielding measurable increases in electrical resistance. In this case, T(sub c) = 6 K, which is approximately the upper limit of the operating-temperature range of silicon-based bolometers heretofore used routinely in many laboratories. However, whereas the response speed of a typical silicon- based laboratory bolometer is characterized by a frequency of the order of a kilohertz, the response speed of the present device is much higher characterized by a frequency of the order of 100 MHz. For this or any bolometer, a useful figure of merit that one seeks to minimize is (NEP)(tau exp 1/2), where NEP denotes the noise-equivalent power (NEP) and the response time. This figure of merit depends primarily on the heat capacity and, for a given heat capacity, is approximately invariant. As a consequence of this approximate invariance, in designing a device having a given heat capacity to be more sensitive (to have lower NEP), one must accept longer response time (slower response) or, conversely, in designing it to respond faster, one must accept lower sensitivity. Hence, further, in order to increase both the speed of response and the sensitivity, one must make the device very small in order to make its heat capacity very small; this is the approach followed in developing the present device.

Karasik, Boris↗

Giant magnetic coercivity in orthorhombic YNi{sub 4}Si-type SmNi{sub 4}Si compound

Magnetic properties, magnetocaloric effect and heat capacity of the YNi{sub 4}Si-type SmNi{sub 4}Si compound have been investigated. SmNi{sub 4}Si exhibits ferromagnetic transition at 17 K. Below ~9 K, the magnetic isotherms of SmNi{sub 4}Si show metamagnetic-like behavior with critical field of 20 kOe at 5 K. Heat capacity measurements of SmNi{sub 4}Si show the electronic heat capacity coefficient γ=94 mJ/(mol K{sup 2}), phonon coefficient β=0.35 mJ/(mol K{sup 4}) and Debye temperature T{sub D}=310 K. The magnetocaloric effect of SmNi{sub 4}Si is calculated in terms of isothermal magnetic entropy change which is obtained by the isothermal magnetization (ΔS{sub m}{sup magn}) and heat capacity measurements (ΔS{sub m}{sup heat}). Both ΔS{sub m}{sup magn} and ΔS{sub m}{sup heat} reach a maximum of –1.0 J/kg K at 17 K for a field change of 50 kOe and they show positive values for a field change of 20 kOe at ~9 K. Below 15 K, SmNi{sub 4}Si shows large magnetic hysteresis with considerable remanence. At 5 K it exhibits giant coercive field of 58 kOe in an applied field of 90 kOe. - Highlights: • YNi{sub 4}Si-type SmNi{sub 4}Si has Curie point at 17 K. • ΔS{sub m}{sup magn} of SmNi{sub 4}Si reaches value of –1.0 J/kg K in 0–50 kOe near Curie point. • ΔS{sub m}{sup magn} of SmNi{sub 4}Si shows value of –0.4 and +0.8 J/kg K at 17 and 9 K in 0–20 kOe. • SmNi{sub 4}Si shows electronic heat capacity the 94 mJ/(mol K{sup 2}) and Debye T{sub D}=310 K. • SmNi{sub 4}Si shows huge magnetic hysteresis with coercive field of 58 kOe at 5 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Temperature-Following Thermal Barrier Coatings for High Efficiency Engines (Final Report)

HRL Laboratories and General Motors (GM), pursued this effort to increase the efficiency of internal combustion engines (ICEs) by developing and implementing temperature-following thermal barrier coatings (TBCs) to decrease heat loss from the combustion chamber. HRL developed microsphere TBCs based on hollow high-temperature alloy spheres with average diameter of 50 μm and wall thickness ~1 μm (microspheres) that achieve unprecedented low thermal conductivity and heat capacity (10X lower than the state of the art) while offering exceptional environmental and mechanical resistance.> In current ICEs, approximately 29% of the fuel’s energy is lost to the cooling system and about 22% goes into moving the car. By limiting heat losses from the combustion chamber with insulating coatings, fuel energy can be redirected into additional piston work and into the exhaust stream. The additional energy that goes into the exhaust stream can be turned into useful work through the use of an exhaust energy recovery device, such as turbocompounding and/or through driving a turbocharger to increase the power density of the engine allowing downsizing. Insulating coatings for piston crowns have been pursued in the past, but previous materials—typically ceramics—exhibited low thermal conductivity but retained high heat capacity. Such materials reduce heat losses but stabilize at a high surface temperature. The high surface temperature heats the incoming gases, which lowers volumetric efficiency and increases propensity for knock, resulting in degraded engine performance. This program developed an innovative new material that combines low thermal conductivity with low heat capacity. These unique properties allow it to follow rapid changes in gas temperature during each combustion cycle. A metallic microsphere TBC has been demonstrated that exhibits increased surface temperature during the combustion period, resulting in reduced heat transfer losses, while still returning to a low surface temperature during the gas exchange period. A 10X lower thermal conductivity and heat capacity than state-of-the-art thermal barrier coatings has been demonstrated. These unprecedented thermal properties are achieved through the coating architecture, which consists of closed pores on the microscale and exhibits a total porosity of 90% to 95%. By selecting a high-temperature nickel alloy as the coating material, the ductility and strength of metals can be harnessed to achieve much better durability and damage tolerance than brittle ceramic coatings can achieve.

33 ADVANCED PROPULSION SYSTEMS↗