Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat utilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Current activated reactive ultrafast joining (CARUJ) of silicon carbide

In this work we propose and demonstrate a novel approach for rapid fabrication of ceramic-ceramic joint assemblies, using sintered Silicon Carbide (SiC) as an initial example. Current Activated Reactive Ultrafast Joining (CARUJ) utilizes resistive heating of carbon-based materials to apply localized heat at or around the joint zone at heating rates of 101– 103 °C/min. CARUJ is used to fabricate SiC-SiC joints with a Si-SiC interface using minimal pressure (1–2 MPa) at time scales considerably shorter (several minutes opposed to hours) than conventional approaches for similar systems. The reaction of an interfacial precursor based on elemental silicon and carbon leads to in-situ SiC formation to produce a continuous and dense bond in a single step. Measured average joint strengths of roughly 15 MPa are achieved when tested in single lap offset (SLO) compressive shear. Optional additions of refractory metals such as molybdenum can be utilized to introduce secondary inclusions such as MoSi 2 within the joint interface. We further demonstrate SiC-SiC joining using Active Brazing Alloys (ABA) and proof of concept joining of tubular geometries. The localized and rapid heat application realizes a versatile material joining technique that could be extended for joining components at the plant site.

36 MATERIALS SCIENCE↗

A proposed concept for the extraction of energy stored in magnetic or electric fields in space

It is known that enormous energy resources associated with electric, magnetic, gravitational, and other fields exist in space. It is also known that the major difficulty in 'tapping' this energy arises from the extremely low density level at which this energy exists. An analytical study has been made of a particular scheme that appears promising for an efficient utilization of some of these energy resources in propulsion. The principle involves the exchange of energy between a fluctuating magnetic field and a velocity field of electrically conducting fluid in turbulent motion located onboard a spacecraft. Under certain conditions the total energy of the turbulent flow field onboard the spacecraft can be increased and this increase appears in the form of Joulean heat. The utilization of the fluctuating part of the magnetic field, in the form of Joulean dissipation (because of its random character) does not introduce any drag on the spacecraft. The application appears promising for flights in the vicinity of Jupiter and other planets. The rate at which energy is gained by the conducting fluid is of the order of 100 watts when the rms value of the fluctuating magnetic field strength is about 1 gauss.

Papailiou, D. D.↗

Radioisotope Power System Cask Trailer Chiller Low Heat Load Study

This report documents the study of the Radioisotope Thermoelectric Generator Transport System (RTGTS) chillers capability to transport a Radioisotope Power System (RPS) with low heat loads in the cask. Tests of the RTGTS chillers included setting the glycol/water (coolant) temperature to a control set point of 40° and 60°F while applying heat loads ranging from 2500 to 0 W heat load. The tests performed showed that the chiller systems could handle the entire range of heat loads. However, a noise/vibration started to occur when the set point was 60°F with low heat loads. Three recommended changes to the RTGTS chillers are recommended with varying implementation windows. The first is an operational change that can be implemented immediately. The RTGTS chillers should have a set point of 40°F when transporting an RPS less than 1500 W. The second is a short-term change (within the next two years) augmenting RPS heat by utilizing one RTGTS onboard heater (2500 W) while transporting an RPS with less than 1500 W which will also require a change to the Instrument and Data Acquisition System (IDAS) to allow monitoring and possible control of power to the onboard heaters. However, if the heater does fail during transport, no emergency actions or immediate repairs will be required due to the chillers’ ability to handle low heat loads. Running a 2500 W heater when transporting low heat loads aids in prolonging the life of the chillers. The remaining recommended long-term change is to replace the current chillers with a new portable or permanently installed chiller system in the next five to ten years. This time frame takes advantage of the proven reliability and durability of the current chillers while the new chillers are phased in and proven to the RPS program.

42 ENGINEERING↗

Heat Pump Water Heater Guide for Small Businesses

This guide is intended for building owners and facility managers interested in electrifying commercial building water heating systems via new building systems or system retrofits. This guide is also a resource for contractors becoming familiar with commercial heat pump water heaters (HPWHs). This guide focuses on integrated air-source HPWH equipment, and background information, best practices, and key considerations are included here. A building owner or facility manager should review project considerations with an engineer or contractor.

decarbonization↗

Comparison of Advanced Residential Water Heating Technologies in the United States

In this study, gas storage, gas tankless, condensing, electric storage, heat pump, and solar water heaters were simulated in several different climates across the United States, installed in both conditioned and unconditioned space and subjected to several different draw profiles. While many pre-existing models were used, new models of condensing and heat pump water heaters were created specifically for this work. In each case modeled, the whole house was simulated along with the water heater to capture any interactions between the water heater and the space conditioning equipment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated Optimization and Control of a Hybrid Gas Turbine/sCO 2 Power System

During phase-I, the project team led by Echogen Power Systems (EPS) had two primary objectives based on investigating the application of gas turbines with supercritical carbon dioxide (sCO 2 ) power cycles. The first objective was to improve the overall efficiency and performance of a hybrid gas turbine/sCO 2 power system through a joint optimization of the two subsystems (gas turbine and sCO 2 power cycle) using non-linear optimization techniques that simultaneously evaluate thermal performance of the combined cycle. The hybrid power system included several points of interaction, including (but not limited to) gas turbine exhaust, fuel heating, inlet chilling and turbine cooling. The second objective was to establish a baseline transient response model of the hybrid power system and a notional microgrid and begin steps to integrate the control systems of the three major elements (gas turbine, sCO 2 cycle and grid controller). The project team established a baseline performance for a combined cycle power plant using a production gas turbine and scaled sCO 2 power cycle only utilizing exhaust heat recovery. Echogen’s non-linear techno-economic optimization code was extended by adding gas turbine component models derived from a in-house developed gas turbine design code. With the two cycles coupled by the gas turbine exhaust, design parameters of both cycles were allowed to vary simultaneously to determine performance opportunity versus isolated designs. Returning to the baseline gas turbine/sCO 2 power cycle transient models: Echogen had in-house developed sCO 2 cycle transient model in GT-Suite system simulation software, and had partnered with Siemens Finspång for gas turbine transient model, and Siemens PTI group to provide micro-grid load profile as well as hybrid power cycle generated load (power and frequency) analysis. The transient model for the SGT-750 Siemens gas turbine was a “black-box” functional mock-up interface (FMI) model developed by Siemens Industrial Turbomachinery in Finspång, Sweden. The SGT-750 is a twin-shaft gas turbine that produces 40 MW electricity with an efficiency of about 40% at ISO conditions. At 100% gas turbine throttle (load), the SGT-750 has average exhaust conditions of 114.6 kg/s and 469.8°C. The transient model for sCO 2 power cycle was developed by Echogen in GT-SUITE 1D system simulation software platform. The basic CO 2 flow circuit has single-shaft turbomachinery with net 11.5 MW electrical power output at design conditions. The power turbine has a double-ended shaft with one end connected to synchronous generator through a fixed-ratio gearbox. The other end of power turbine is connected to the compressor through a continuously variable transmission. The major components of the sCO 2 power cycle modeled include air cooled condenser/cooler, CO 2 compressor, recuperator, two waste heat exchanger coils, power turbine, continuous variable transmission, gearbox and generator. Integration of SGT-750 transient model and sCO 2 power cycle transient model was done in Matlab Simulink. In the integrated model, the gas turbine and sCO 2 power cycle interacted at two points, first one being the gas turbine exhaust gas flow rate and temperature, which were inputs to sCO 2 power cycle model. The second point was the distribution of micro-grid load demand signal between the SGT-750 generator and sCO 2 cycle generator. For a given combined-cycle load demand, the gas turbine load demand was equal to the total demand minus the sCO 2 cycle power generated. In the present study the integrated model was simulated for two cases of grid load demand: (i) for a step change, both positive-step and negative-step, in grid load demand (ii) for a micro-grid load demand curve provided by Siemens PTI group. Finally, the time series plots representing load demand versus integrated system response were presented including the sCO 2 power cycle control system performance plots. The actual generated power and frequency of both the generators, gas turbine and sCO 2 power cycle, was supplied to Siemens PTI group for dynamic grid assessment, results of which are provided in appendices.

03 NATURAL GAS↗

Design complexity and performance analysis in additively manufactured heat exchangers

The main objective of this research is to investigate the tradeoffs between design complexity and thermal performance in additively manufactured metallic heat exchangers. Such heat exchangers have become a favorite topic for investigation in various fields ranging from air conditioning to aircraft gas turbine engines. In particular, high manufacturing cost has emerged as the major drawback in broad applications of manifold-microchannel heat exchanger (MMHXs). The possibility of cost-effective manufacturing has generated wide interest in applying additive manufacturing (AM) for fabricating MMHXs. Furthermore, AM technologies will provide an opportunity for enhanced design and superior heat transfer performance. In this study, innovative MMHXs are designed and fabricated through selective laser melting. An experimental setup was designed to measure pressure drop and heat transfer for the developed MMHXs with a wide range of Reynolds numbers. Furthermore, the coefficient of performance was calculated based on the heat flow rate, air pressure drop, and air flow rate. Measurement results demonstrated that in some scenarios adding more internal features, i.e., increasing design complexity, does not necessarily improve the MMHX performance.

10 SYNTHETIC FUELS↗

Split HPWHs as an Efficient Solution for Multifamily Buildings with In-Unit Water Heaters

A quarter of all housing units in the United States are found in multifamily buildings, but few efficiency innovations have been made to improve electric water heating systems in this building type. Domestic hot water in multifamily buildings can either be provided by a large central water heater or smaller in-unit water heaters. Integrated heat pump water heaters that are installed in single-family homes are often a poor fit for individual multifamily units because the water heaters are often located in small internal closets. This confined space can limit the airflow to the heat pump, and the cold exhaust air can cause discomfort and reduced efficiency. Split CO2 HPWHs separate the tank from the heat pump, which allows for installation location flexibility. Further, CO2 heat pumps can operate under colder ambient conditions, making them a better fit for multifamily units across a wide range of climate regions. As part of a larger project to characterize split HPWH performance, we evaluated the feasibility of installing an additional, parallel tank that could provide hot water to a second housing unit using a single CO2 heat pump. This approach would reduce the first costs of these more expensive units. Based on the high draw volume that we imposed on both tanks, the same heat pump may be able to support more tanks, depending on hot water usage. This paper will describe the split CO2 HPWH technology, how the two-tank system was controlled, and results from our laboratory evaluation.

CO2 HPWH↗

Appalachian Basin Temperature-Depth Maps and Structured Data in support of Feasibility Study of Direct District Heating for the Cornell Campus Utilizing Deep Geothermal Energy

This dataset contains shapefiles and rasters that summarize the results of a stochastic analysis of temperatures at depth in the Appalachian Basin states of New York, Pennsylvania, and West Virginia. This analysis provides an update to the temperature-at-depth maps provided in the Geothermal Play Fairway Analysis of the Appalachian Basin (GPFA-AB) Thermal Quality Analysis (GDR repository 879: https://gdr.openei.org/submissions/879). This dataset improves upon the GPFA-AB dataset by considering several additional uncertainties in the temperature-at-depth calculations, including geologic properties and thermal properties. A Monte Carlo analysis of these uncertain properties and the GPFA-AB estimated surface heat flow was used to predict temperatures at depth using a 1-D heat conduction model. In this data submission, temperatures are provided for depths from 1-5 km in 0.5 km increments. The mean, standard deviation, and selected quantiles of temperatures at these depths are provided as shapefiles with attribute tables that contain the data. Rasters are provided for the mean and standard deviation data. Figures and maps that summarize the data are also provided. For the pixel corresponding to Cornell University, Ithaca, NY, a .csv file containing the 10,000 temperature-depth profiles estimated from the Monte Carlo analysis is provided. These data are summarized in a figure containing violin plots that illustrate the probability of obtaining certain temperatures at depths below Cornell.

15 GEOTHERMAL ENERGY↗

Time-domain theory of transient heat conduction in the local limit

Ultrafast and nanoscale heat conduction demands a unified theoretical framework that rigorously bridges macroscopic transport equations with microscopic material properties derived from statistical physics. Existing empirical generalizations of Fourier's law often lack a solid microscopic foundation, failing to connect observed non-Fourier behavior with underlying atomic-scale mechanisms. In this work, we present a time-domain theory of transient heat conduction rooted in Zwanzig's statistical theory of irreversible processes. Central to this framework is the time-domain transport function $\overleftrightarrow{𝑍}$⁡(𝑡) defined through equilibrium time-correlation functions of heat fluxes. This function generalizes the conventional concept of steady-state thermal conductivity, governing the transition of conduction dynamics from onset second sound type wave propagation at finite speeds to diffusion-dominated behavior across broad temporal and spatial scales. Unlike phonon hydrodynamic models that rely on mesoscopic constructs such as phonon drift velocity, our approach provides a quantitative and microscopic description of intrinsic memory effects in transient heat fluxes and applies universally to bulk materials at any temperature or length scale. By integrating atomistic-scale first-principles calculations with continuum-level macroscopic equations, this framework offers a robust foundation for numerical simulations of transient temperature fields. Furthermore, it facilitates the interpretation and design of transient thermal grating experiments using nanometer-scale heat sources and ultrafast laser systems in the extreme ultraviolet and x-ray wavelength ranges, advancing our understanding of heat dissipation dynamics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Split HPWHs as an Efficient Solution for Multifamily Buildings with In-Unit Water Heaters: Preprint

A quarter of all housing units in the country are found in multifamily buildings but few efficiency innovations have been made to improve electric water heating systems in this building type. Domestic hot water in multifamily buildings can either be provided by a large central water heater or smaller in-unit water heaters. Integrated heat pump water heaters that are installed in single family homes are often a poor fit for individual multifamily units since the water heaters are often located in small internal closets. This confined space can limit the air flow to the heat pump and the cold exhaust air can cause discomfort and reduced efficiency. Split CO2 HPWHs separate the tank from the heat pump, which allows for installation location flexibility. Further, CO2 heat pumps can operate under colder ambient conditions, making them a better fit for multifamily units across a wide range of climate regions. As part of a larger project to characterize split HPWH performance, we evaluated the feasibility of installing an additional, parallel tank that could provide hot water to a second housing unit using a single CO2 heat pump. This approach would reduce the first costs of these more expensive units. Based on the high draw volume that we imposed on both tanks, the same heat pump may be able to support more tanks, depending on hot water usage. This paper will describe the split CO2 HPWH technology, how the two-tank system was controlled, and results from our laboratory evaluation.

CO2 HPWH↗

Energy Model of an Air Source Heat Pump to Explore Performance Improvements under Cold Conditions: A Python Framework: Preprint

Replacing combustion appliances with heat pumps can be part of a strategy to electrify buildings. When their electricity is supplied by renewables, the adoption of heat pumps for space heating may help curb the carbon dioxide emissions inherent to traditional heating systems that burn natural gas or coal. When operating in very cold climates, however, heat pump performance deteriorates, sometimes requiring backup heating supplied by electric resistances or other sources to continue to function. To avoid the use of electric resistances, complementary technologies, like thermal energy storage, solar collectors, or alternative refrigerants, have been explored in recent years. In this study, we present an open-source Python-based numerical model developed to evaluate the annual hourly performance of an air source heat pump (ASHP) operating in the USA. Simulation results include coefficient of performance and heating capacity. The model, validated with experimental results, will be employed in the future to investigate the feasibility of integrating thermal energy storage and other technologies into ASHPs operating in cold climates.

cold climate↗

Refrigerated Warehouse Demand Response Strategy Guide

This guide summarizes demand response measures that can be implemented in refrigerated warehouses. In an appendix, it also addresses related energy efficiency opportunities. Reducing overall grid demand during peak periods and energy consumption has benefits for facility operators, grid operators, utility companies, and society. State wide demand response potential for the refrigerated warehouse sector in California is estimated to be over 22.1 Megawatts. Two categories of demand response strategies are described in this guide: load shifting and load shedding. Load shifting can be accomplished via pre-cooling, capacity limiting, and battery charger load management. Load shedding can be achieved by lighting reduction, demand defrost and defrost termination, infiltration reduction, and shutting down miscellaneous equipment. Estimation of the costs and benefits of demand response participation yields simple payback periods of 2-4 years. To improve demand response performance, it’s suggested to install air curtains and another form of infiltration barrier, such as a rollup door, for the passageways. Further modifications to increase efficiency of the refrigeration unit are also analyzed. A larger condenser can maintain the minimum saturated condensing temperature (SCT) for more hours of the day. Lowering the SCT reduces the compressor lift, which results in an overall increase in refrigeration system capacity and energy efficiency. Another way of saving energy in refrigerated warehouses is eliminating the use of under-floor resistance heaters. A more energy efficient alternative to resistance heaters is to utilize the heat that is being rejected from the condenser through a heat exchanger. These energy efficiency measures improve efficiency either by reducing the required electric energy input for the refrigeration system, by helping to curtail the refrigeration load on the system, or by reducing both the load and required energy input.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis and comparison of wall cooling schemes for advanced gas turbine applications

The relative performance of (1) counterflow film cooling, (2) parallel-flow film cooling, (3) convection cooling, (4) adiabatic film cooling, (5) transpiration cooling, and (6) full-coverage film cooling was investigated for heat loading conditions expected in future gas turbine engines. Assumed in the analysis were hot-gas conditions of 2200 K (3500 F) recovery temperature, 5 to 40 atmospheres total pressure, and 0.6 gas Mach number and a cooling air supply temperature of 811 K (1000 F). The first three cooling methods involve film cooling from slots. Counterflow and parallel flow describe the direction of convection cooling air along the inside surface of the wall relative to the main gas flow direction. The importance of utilizing the heat sink available in the coolant for convection cooling prior to film injection is illustrated.

Colladay, R. S.↗

Heat Pumps and Energy Recovering Ventilators in Northern Alaska

The intended purpose of this project was to bring alternative heat and ventilation options to rural communities off the road system in Northwestern Alaska. Most of the residents of these communities are reliant upon kerosene or other fossil fuels to provide heat to their homes. Our intention was to offer an alternative to using those sources by providing heat pumps to 45 homes in the communities of Elim and Koyuk. When projecting energy use for these units based on the fuel prices at the time, it was discovered that energy costs for heat pumps would equal or slightly exceed the costs of existing kerosene units. Secondly, as part of our E&l grant we installed 45 energy recovery ventilators (ERV’s) in those same homes. This was important given our experience over the years with moisture and comfort issues in most homes within this region. Exhaust-only systems are rarely used due to the high heating costs. Additionally, exhaust-only systems have a potential risk of back drafting due to tight building construction. Balanced systems like this eliminate that risk while improving indoor air quality. Another benefit to these types of systems is the fact that they help transfer heat from a single heat source equally throughout the building. Our overall goal was to offer new technology options to improve these structures and the families that reside in them where, given their location and extreme seasonal temperature swings, they have historically never been offered.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multiscale modeling of microwave-heated multiphase systems

Modeling of microwave heating of multiphase systems requires resolving the electromagnetic field from the single particle to the entire cavity. We introduce a multiscale methodology for computationally affordable simulations of microwave heating of multiphase systems consisting of one phase dispersed in a continuum phase. The methodology homogenizes the original multiphase system, by taking advantage of the large separation of length scales, to calculate the effective permittivity, effective thermal conductivity, and volumetric power absorbed in each phase. The methodology is rigorously assessed against particle-resolved detailed numerical simulations of model systems. We demonstrate a significant reduction in computational cost while retaining the accuracy of detailed simulations. Lastly, the present methodology enables high throughput exploration of novel multiphase system designs utilizing microwave heating.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗