Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “guide tubes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Nuclear Safety [Vol. 30, No. 3, July-September 1989]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 325 Safety of Framatome Advanced Nuclear Steam Supply Systems Designs by J. A. Charles and D. Lange, 333 Book Review of Nuclear Accidents: Intervention Levels for the Protection of the Public by H. B. Piper; ACCIDENT ANALYSIS: 335 Living PRA Computer Systems by S. C. Dinsmore and H.-P. Balfanz, 343 Summary of ICAP Assessments of RELAP5/MOD2 by W. E. Driskell and R. G. Hanson; CONTROL AND INSTRUMENTATION: 352 Thermal Performance Monitoring System at Maanshan Nuclear Power Plant by H.-J. Chao, Y.-P. Lin, G.-H. Jou, L.-Y. Liao, and Y.-B. Chen; DESIGN FEATURES: 358 Warning Systems for Nuclear Power Plant Emergencies by J. H. Sorensen and D. S. Mileti; WASTE AND SPENT FUEL MANAGEMENT: 371 Activities Related to Waste Management Compiled by E G. Silver; OPERATING EXPERIENCES: 382 Steam Generator Tube Performance: Experience with Water-Cooled Nuclear Power Reactors During 1985 by O. S. Tatone and R. L. Tapping, 400 Systems Interaction Analyses: Concepts and Techniques (Part II) by M. D. Muhlheim and G. A. Murphy, 413 Reactor Shutdown Experience Compiled by J. W. Cletcher, 416 Operating U.S. Power Reactors Compiled by E G. Silver; RECENT DEVELOPMENTS: 440 General Administrative Activities Compiled by E G. Silver, 460 Reports, Standards, and Safety Guides by D. S. Queener, 466 Status of Power-Reactor Licensing Activities Compiled by E G. Silver, 470 Proposed Rule Changes as of Mar. 31, 1989; ANNOUNCEMENTS: 334 Proceedings Published, 351 CEC Seminar on Methods and Codes for Assessing the Off-Site Consequences of Nuclear Accidents, 357 Short Course on Multiphase Flow and Heat Transfer: Bases and Applications in A: The Nuclear Power Industry B: The Process Industries, 357 International Conference on Probabilistic Safety Assessment and Management, 478 International Topical Meeting on the Safety, Status, and Future of Non-Commercial Reactors and Irradiation Facilities, 475 The Authors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Initial Testing of Optical Arc Detector Inside 285/300 Fast Wave Antenna Box on DIII-D

Locating arcs within the fast wave current drive system is necessary to improve antenna performance and coupling to the plasma. Previously, there had been no way to observe arcs inside the vacuum vessel in an ICRF antenna on DIII-D. A new diagnostic that uses photomultiplier tubes has been installed for the 2012 run campaign on the 285/300 antenna of the fast wave system. The diagnostic has top and bottom views of the back of the four antenna straps and uses narrow-bandpass visible filters to isolate emission lines of copper (577 nm) and deuterium (656.1 nm). This diagnostic is based on the ORNL filterscope system currently in use on multiple devices. The system will be used to guide fast wave antenna conditioning, plasma operation and provide insight into future antenna upgrades on DIII-D.

Diem, Stephanie J↗

The structure and energy balance of cool star atmospheres

The atmospheric structure and energy balance phenomena associated with magnetic fields in the Sun are reviewed and it is shown that similar phenomena occur in cool stars. The evidence for the weakening or disappearance of transition regions and coronae is discussed together with the appearance of extended cool chromospheres with large mass loss, near V-R = 0.80 in the H-R diagram. Like the solar atmosphere, these atmospheres are not homogeneous and there is considerable evidence for plage regions with bright TR emission lines that overlie dark (presumably magnetic) star spots. The IUE observations are providing important information on the energy balance in these atmospheres that should guide theoretical calculations of the nonradiative heating rate. Recent high dispersion spectra are providing unique information concerning which components of close binary systems are the dominant contributors to the observed emission. A recent unanticipated discovery is that the transition lines are redshifted (an antiwind) in DRa (G2 Ib) and perhaps other stars. Finally, the G and K giants and supergiants are classified into three groups depending on whether their atmospheres are dominated by closed magnetic flux tubes, open field geometries, or a predominately open geometry with a few closed flux tubes embedded.

Linsky, J. L.↗

SU-E-I-80: Beta-Minus Emitting Radiotracers Improves Molecular Endoscopy

Purpose: Molecular Endoscopy using Cerenkov Luminescence can be used to monitor the distribution of many clinically-available PET and SPECT probes for endoscopic applications. A main limitation of Cerenkov is its limited sensitivity to small concentrations of radiotracer when using light guides s. Herein we demonstrate that the use of a high energy beta emitting radioisotope, exemplified here with 90Y provides superior sensitivity to 18F because of its higher light output and its lack of corresponding gamma emission. Methods: A series of phantom experiments were performed to compare the sensitivity and noise of the CLE system for imaging 90Y and 18F. Three vials of known concentrations of 90Y (0.008 μCi, 0.08 μCi, 1 μCi) were placed in centrifuge tubes and isolated from each other. One vial of 18F (100 μCi) was placed in the imaging chamber and imaged over the course of decay (19 hours, 43 minutes, or ∼10 half-lives). Image time-points were formed from 5-minute integrations. Results: Using an SNR of 10 to define the noise-floor, the 90Y minimum detectable activity was 0.056 μCi. To the contrast, the minimum detectable activity for 18F was 11.63 μCi. These data demonstrate a 207-fold improvement in SNR of 90Y compared to 18F, when controlled for activity. Conclusion: This study demonstrated that a pure β- radionuclide such as 90Y be used is superior to 18F for Cerenkov Endoscopy. Further study is needed to demonstrate its utility in preclinical studies, endoscopic applications, intraoperative, and radiotherapy applications.

07 ISOTOPE AND RADIATION SOURCES↗

C-arm Cone Beam Computed Tomographic Needle Path Overlay for Fluoroscopic-Guided Placement of Translumbar Central Venous Catheters

C-arm cone beam computed tomography is an advanced 3D imaging technology that is currently available on state-of-the-art flat-panel-based angiography systems. The overlay of cross-sectional imaging information can now be integrated with real-time fluoroscopy. This overlay technology was used to guide the placement of three percutaneous translumbar inferior vena cava catheters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Hubble Space Telescope fine guidance system operating in the coarse track pointing control mode

The Hubble Space Telescope (HST) Fine Guidance System has set new standards in pointing control capability for earth orbiting spacecraft. Two precision pointing control modes are implemented in the Fine Guidance System; one being a Coarse Track Mode which employs a pseudo-quadrature detector approach and the second being a Fine Mode which uses a two axis interferometer implementation. The Coarse Track Mode was designed to maintain FGS pointing error to within 20 milli-arc seconds (rms) when guiding on a 14.5 Mv star. The Fine Mode was designed to maintain FGS pointing error to less than 3 milli-arc seconds (rms). This paper addresses the HST FGS operating in the Coarse Track Mode. An overview of the implementation, the operation, and both the predicted and observed on orbit performance is presented. The discussion includes a review of the Fine Guidance System hardware which uses two beam steering Star Selector servos, four photon counting photomultiplier tube detectors, as well as a 24 bit microprocessor, which executes the control system firmware. Unanticipated spacecraft operational characteristics are discussed as they impact pointing performance. These include the influence of spherically aberrated star images as well as the mechanical shocks induced in the spacecraft during and following orbital day/night terminator crossings. Computer modeling of the Coarse Track Mode verifies the observed on orbit performance trends in the presence of these optical and mechanical disturbances. It is concluded that the coarse track pointing control function is performing as designed and is providing a robust pointing control capability for the Hubble Space Telescope.

Whittlesey, Richard↗

Further Development of Scaffolds for Regeneration of Nerves

Progress has been made in continuing research on scaffolds for the guided growth of nerves to replace damaged ones. The scaffolds contain pores that are approximately cylindrical and parallel, with nearly uniform widths ranging from tens to hundreds of microns. At the earlier stage of development, experimental scaffolds had been made from agarose hydrogel. Such a scaffold was made in a multistep process in which poly(methyl methacrylate) [PMMA] fibers were used as templates for the pores. The process included placement of a bundle of the PMMA fibers in a tube, filling the interstices in the tube with a hot agarose solution, cooling to turn the solution into a gel, and then immersion in acetone to dissolve the PMMA fibers. The scaffolds were typically limited to about 25 pores per scaffold, square cross sections of no more than about 1.5 by 1.5 mm, and lengths of no more than about 2 mm.

Sakamoto, Jeffrey↗

The KATRIN superconducting magnets: Overview and first performance results

The KATRIN experiment aims for the determination of the effective electron anti-neutrino mass from the tritium beta-decay with an unprecedented sub-eV sensitivity. The strong magnetic fields, designed for up to 6 T, adiabatically guide β-electrons from the source to the detector within a magnetic flux of 191 Tcm 2 . A chain of ten single solenoid magnets and two larger superconducting magnet systems have been designed, constructed, and installed in the 70-m-long KATRIN beam line. The beam diameter for the magnetic flux varies from 0.064 m to 9 m, depending on the magnetic flux density along the beam line. Two transport and tritium pumping sections are assembled with chicane beam tubes to avoid direct "line-of-sight" molecular beaming effect of gaseous tritium molecules into the next beam sections. The sophisticated beam alignment has been successfully cross-checked by electron sources. In addition, magnet safety systems were developed to protect the complex magnet systems against coil quenches or other system failures. The main functionality of the magnet safety systems has been successfully tested with the two large magnet systems. The complete chain of the magnets was operated for several weeks at 70% of the design fields for the first test measurements with radioactive krypton gas. The stability of the magnetic fields of the source magnets has been shown to be better than 0.01% per month at 70% of the design fields. This paper gives an overview of the KATRIN superconducting magnets and reports on the first performance results of the magnets.

47 OTHER INSTRUMENTATION↗

Excitation/Detection Strategies for OH Planar Laser-Induced Fluorescence Measurements in the Presence of Interfering Fuel Signal and Absorption Effects

Planar laser-induced fluorescence (PLIF) excitation/detection methods have been applied to obtain spatial distributions of the hydroxyl [OH] reacting intermediary and hydrocarbon [HC] primary species in laminar and turbulent combustion reactions. In this report, broadband and narrowband excitation/filtering techniques are explored to identify an optimal experimental configuration yielding significant fluorescent signal with low absorption losses. The combustion environments analyzed include 1) a laminar non-premixed methane/air flame and 2) a turbulent, non-premixed Jet-A/air fueled flame within a lean flame tube combustor. Hydrocarbon-based fuel and OH were excited via the R1 (1), R1(10) and R2(7) transitions of the A(sup 2)Epsilon(+) X(sup 2)pi(1,0) band using a broadband Nd:YAG pumped optical parametric oscillator (OPO) and narrowband Nd:YAG/dye laser with ultraviolet frequency extension (UVX) package. Variables tested for influence on fluorescent signal and absorption characteristics were excitation line, laser energy, exciting linewidth, combustion reactants, and test flow conditions. Results are intended to guide the transition from a dye/UVX laser to an OPO system for performing advanced diagnostics of low-emission combustion concepts.

Heath, Christopher M.↗

Interim Report on the Optimization and Feasibility Studies for the Neutron Detection without Helium-3 Project

This report details the results of the work accomplished for the „Neutron Detection without Helium-3‟ project during the 2011 fiscal year. The primary focus of the project during this year was to develop models using alternatives to helium-3 to investigate the possibilities and optimizations for multiplicity counters in safeguards applications by computer simulations. The multiplicity counter with significant capability, the Epithermal Neutron Multiplicity Counter (ENMC), was used as the baseline requirement for alternative technologies, which, if a suitable alternative can be found, should also satisfy systems with less stringent requirements, including coincidence counters. The project is in collaboration with Los Alamos National Laboratory (LANL), and the baseline model of the ENMC that had been developed at LANL with helium-3 as the detector material was used as a starting point. The model was modified to support optimization investigations, and verified with the helium-3 base material. The model was then modified to incorporate boron-trifluoride (BF3) gas, which can be used as a proportional gas similar to helium-3. The BF3 gas however, cannot be operated at very high pressure, and therefore optimization were performed with lower pressures and involved changing the tube size and number. The simulation of this model is very similar in approach to the model with helium-3 where the simulation ends when the neutron is captured in the boron. The reaction products are easily detected in the proportional gas, and the simulation results of counting the number of reactions matches well with experimental data. Next, the tubes were replaced with boron-lined proportional tubes, where the neutron capture material is a thin boron lining inside the tube wall, and which use standard proportional counting gas. For this alternative, the simulation needs to extend beyond the neutron capture, and track the reaction products, which must exit the boron-lining into the counting gas. The reaction products do not always end up in the counting gas, depending on the boron-lining thickness and neutron capture depth. Methods to track the reaction products have been recently implemented into MCNPX and were verified by using several different approaches. The tube number and size were also varied for the boron-lined case. Finally, work has started on a model of an alternative using lithium-6, another material with a high cross-section for thermal neutron capture. The most promising approach is with lithium fluoride in a zinc sulfide (silver activated) scintillator medium. The neutron is captured in the lithium, and the reaction products trigger scintillation light in the zinc sulfide, which is subsequently detected by photo-multipliers by the use of light guides or fibers. The simulations were performed with the focus on determining the efficiency, which is critical when detecting 2 or 3 neutrons in coincidence, as well as the die-away time, which is a measure of the time required to capture neutrons in the system. The die away time is related to the coincident time gate needed for the system which drives the accidental coincident rate, the primary background or noise in this type of measurement. The usual figure of merit for coincidence type systems, the efficiency squared divided by the die-away time, was calculated for each variation simulated.

helium-3 alternatives↗

Optical Microscopy-Guided Laser Ablation Electrospray Ionization Ion Mobility Mass Spectrometry: Ambient Single Cell Metabolomics with Increased Confidence in Molecular Identification

Single cell analysis is a field of increasing interest as new tools are continually being developed to understand intercellular differences within large cell populations. Laser-ablation electrospray ionization mass spectrometry (LAESI-MS) is an emerging technique for single cell metabolomics. Over the years, it has been validated that this ionization technique is advantageous for probing the molecular content of individual cells in situ. Here, we report the integration of a microscope into the optical train of the LAESI source to allow for visually informed ambient in situ single cell analysis. Additionally, we have coupled this ‘LAESI microscope’ to a drift-tube ion mobility mass spectrometer to enable separation of isobaric species and allow for the determination of ion collision cross sections in conjunction with accurate mass measurements. This combined information helps provide higher confidence for structural assignment of molecules ablated from single cells. Here, we show that this system enables the analysis of the metabolite content of Allium cepa epidermal cells with high confidence structural identification together with their spatial locations within a tissue.

59 BASIC BIOLOGICAL SCIENCES↗

Comparison of simulated and experimentally measured detector impulse responses to pulsed x-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-toend performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compressive sensing for nuclear security

Special nuclear material (SNM) detection has applications in nuclear material control, treaty verification, and national security. The neutron and gamma-ray radiation signature of SNMs can be indirectly observed in scintillator materials, which fluoresce when exposed to this radiation. A photomultiplier tube (PMT) coupled to the scintillator material is often used to convert this weak fluorescence to an electrical output signal. The fluorescence produced by a neutron interaction event differs from that of a gamma-ray interaction event, leading to a slightly different pulse in the PMT output signal. The ability to distinguish between these pulse types, i.e., pulse shape discrimination (PSD), has enabled applications such as neutron spectroscopy, neutron scatter cameras, and dual-mode neutron/gamma-ray imagers. In this research, we explore the use of compressive sensing to guide the development of novel mixed-signal hardware for PMT output signal acquisition. Effectively, we explore smart digitizers that extract sufficient information for PSD while requiring a considerably lower sample rate than conventional digitizers. Given that we determine the feasibility of realizing these designs in custom low-power analog integrated circuits, this research enables the incorporation of SNM detection into wireless sensor networks.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modelling and Laboratory Testing of Particle Resuspension and Transport for the Assessment of Terrestrial-Borne Biological Contamination of the Samples on the Mars 2020 Mission

The Mars 2020 mission will land a rover on the surface of Mars that will acquire, encapsulate, and cache scientifically selected samples of martian material for possible return to Earth by a future mission. The samples will be individually encapsulated and sealed in sample tubes. Each sample, and therefore each sample tube, must be kept clean of viable organisms with a terrestrial origin, which may adhere to the rover on their own and/or on other non-biological particles. Therefore, contrary to previous missions to the Red Planet, Mars 2020 is subject to new and more stringent biological, organic and inorganic contamination requirements. This paper reports on the analyses and testing performed to assess the various vectors that can lead to the terrestrial-borne contamination of the samples, focusing on those that are predicted to be the larger contributors. Specifically, the contamination of the sample tubes is expected to be very small prior to the commencement of the mission’s science phase since these tubes are protected by so-called Fluid Mechanical Particle Barriers. Once on the surface of Mars however the sample tubes will be removed from their FMPBs and be subject to contamination from the rover. Of specific interest is the vector by which winds dislodge some particles from the surface of the rover and transport them to the surrounding soil. Naturally, such assessments require multi-disciplinary analyses involving at minimum the physics of particle adhesion and resuspension from surfaces, fluid mechanics and aerosols. Here we provide an overview of these models. We also report on particle resuspension experiments we have performed at the Jet Propulsion Laboratory to both guide and validate the aforementioned physics models.

Steltzner, Adam↗

Comparison of Simulated and Experimentally Measured Detector Impulse Responses to Pulsed X-rays

The Gamma Array Simulation Toolkit (GAST) is a multi-physics software stack comprised of Geant4, MATLAB, and experimentally measured photomultiplier tube (PMT) impulse response waveforms that is used to model and inform the end-to-end performance of radiation detector systems. In order to validate the ability of GAST to predict the impulse response of a modeled detector configuration operated in current mode, experimental measurements using the Nevada National Security Site Transformational Diagnostics and Imaging 2 MeV endpoint energy electron linear accelerator (linac) with a tungsten target were performed. Seven different detector configurations consisting of unique combinations of scintillator material, size, reflectivity conditions, presence or absence of light guide, and PMT were evaluated. The resultant impulse response of each detector configuration was recorded and compared to a GAST simulation that emulated the respective linac experiment conditions. The comparison of the experimental and simulated detector impulse responses indicated that GAST can reliably predict detector impulse responses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

β -decay half-lives and β -delayed neutron emission probabilities for several isotopes of Au, Hg, Tl, Pb, and Bi, beyond N = 126

Background: There have been measurements on roughly 230 nuclei that are β-delayed neutron emitters. They range from 8 He up to 150 La . Apart from 210 Tl, with a branching ratio of only 0.007%, no other neutron emitter has been measured beyond A = 150 . Therefore, new data are needed, particularly in the region of heavy nuclei around N = 126 , in order to guide theoretical models and help understand the formation of the third r-process peak at A ~ 195. Purpose: To measure both β-decay half-lives and neutron branching ratios of several neutron-rich Au, Hg, Tl, Pb, and Bi isotopes beyond N = 126 . Method: Ions of interest were produced by fragmentation of a 238 U beam, selected and identified via the GSI-FRS fragment separator. A stack of segmented silicon detectors (SIMBA) was used to measure ion implants and β decays. An array of 30 3 He tubes embedded in a polyethylene matrix (BELEN) was used to detect neutrons with high efficiency and selectivity. A self-triggered digital system is employed to acquire data and to enable time correlations. The latter were analyzed with an analytical model and results for the half-lives and neutron-branching ratios were derived by using the binned maximum-likelihood method. Results: Twenty new β-decay half-lives are reported for 204-206 Au, 208 – 211 Hg, 211 – 216 Tl , 215 – 218 Pb, and 218 – 220 Bi, nine of them for the first time. Neutron emission probabilities are reported for 210, 211 Hg and 211 – 216 Tl . Conclusions: The new β-decay half-lives are in good agreement with previous measurements on nuclei in this region. Lastly, the measured neutron emission probabilities are comparable to or smaller than values predicted by global models such as relativistic Hartree Bogoliubov plus the relativistic quasi-particle random phase approximation (RHB + RQRPA).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TU-FG-BRB-11: Design and Evaluation of a Robotic C-Arm CBCT System for Image-Guided Proton Therapy

Purpose: To describe the design and performance of a ceiling-mounted robotic C-arm CBCT system for image-guided proton therapy. Methods: Uniquely different from traditional C-arm CBCT used in interventional radiology, the imaging system was designed to provide volumetric image guidance for patients treated on a 190-degree proton gantry system and a 6 degree-of-freedom (DOF) robotic patient positioner. The mounting of robotic arms to the ceiling rails, rather than gantry or nozzle, provides the flexibility in imaging locations (isocenter, iso+27cm in X, iso+100cm in Y) in the room and easier upgrade as technology advances. A kV X-ray tube and a 43×43cm flat panel imager were mounted to a rotating C-ring (87cm diameter), which is coupled to the C-arm concentrically. Both C-arm and the robotic arm remain stationary during imaging to maintain high position accuracy. Source-to-axis distance and source-to-imager distance are 100 and 150cm, respectively. A 14:1 focused anti-scatter grid and a bowtie filer are used for image acquisition. A unique automatic collimator device of 4 independent blades for adjusting field of view and reducing patient dose has also been developed. Results: Sub-millimeter position accuracy and repeatability of the robotic C-arm were measured with a laser tracker. High quality CBCT images for positioning can be acquired with a weighted CTDI of 3.6mGy (head in 200° full fan mode: 100kV, 20mA, 20ms, 10fps)-8.7 mGy (pelvis in 360° half fan mode: 125kV, 42mA, 20ms, 10fps). Image guidance accuracy achieved <1mm (3D vector) with automatic 3D-3D registration for anthropomorphic head and pelvis phantoms. Since November 2015, 22 proton therapy patients have undergone daily CBCT imaging for 6 DOF positioning. Conclusion: Decoupled from gantry and nozzle, this CBCT system provides a unique solution for volumetric image guidance with half/partial proton gantry systems. We demonstrated that daily CBCT can be integrated into proton therapy for pre-treatment position verification.

60 APPLIED LIFE SCIENCES↗

Particle drift in the Earth's plasma sheet

We generalize the derivation of the average gradient/curvature-drift for a flux tube filled with an isotropic distribution of particles at specified kinetic energy. The present treatment is restricted to a two-dimensional magnetic field with zero electric field, but it includes all chaotic and Speiser orbits, which do not correspond to the simple picture of gradient/curvature drift. We assume that particles are evenly distributed throughout the regions of phase space allowed by their energy and canonical momentum. This assumption is closely related but not exactly equivalent to the assumption of isotropic pitch-angle distribution. Our derivation assumes that the maximum Larmor radius is small compared to the scale length for equatorial variations in the flux tube volume, but it does not involve any restrictions on the curvature of the field line. The resulting expression for the drift rate is valid for situations where the particle drift velocity is comparable to the thermal speed in some regions. The apparent implication of this generalized treatment is that the existence of very complex non-adiabatic particle trajectories in the plasma sheet may not invalidate previous estimates of the average rate of particle drift out the sides of the tail, estimates that were made under the assumption of simple guiding-center drifts.

Wolf, R. A.↗