A typical pointed observation in IRAS designed to fit into a 15 minute window

A typical pointed observation in the Infrared Astronomical Satellite (IRAS) was designed to fit into a 15 minute window. Observing constraints, however, did not always permit targets from the scientific program to be observed on exactly 15 minute centers and a few months into the mission it was realized that the automatic scheduling program left times when no observations were being made. In order to use this potentially wasted observing time, a mode of pointed observations, the 'filler' mode, with shorter observation duration was initiated. Locations were picked on an arbitrary grid, spaced relatively uniformly in ecliptic coordinates, and the telescope was pointed to one of these sites whenever a gap potentially occurred. One of us (GXN) was the coordinator of this effort (the FL sub-group). There are a total of 22 FL fields, 13 of which have more than 50 component observations. These 13 fields cover about 30 square degrees. It was proposed to concentrate on one filler field, FL29, a field with 53 coverages which thus had among the deepest coverage of those observed in this mode. This field was also observed extensively at various non-infrared wavelengths by a variety of techniques. Because the IRAS observations of FL29 were made at the limits of the survey sensitivity and at different twist angles it was necessary to make significant technical advances in the methods used in the processing and analyzing the data. In particular, if normal IRAS coaddition procedures were used, the noise resulting from coaddition of the multiple frames did not decrease in the manner expected once significantly different twist angles were included in the coaddition. The technical effort needed to reduce the observations of FL29 was completed and now the noise behavior is understood and well behaved. The reduction of the field FL29 observations is done.

Neugebauer, G.↗

Charging location selection of an incoming electric vehicle for large EV depot infrastructure

As the use of renewable energy resources increases within charging infrastructures, the risk that charging an additional load within the charging infrastructure will create a violation of the applicable grid code also increases. In an embodiment, a charging location is selected for an incoming load based on a load flow analysis, to thereby mitigate the risk of a violation. This selection process may also account for the charging schedule of the load and the capacity of available charging stations (e.g., fast charging vs. slow charging).

Hafiz, Faeza↗

Evaluating power grid model hydropower feasibility with a river operations model

Production cost models (PCMs) simulate dispatch of generators across a large power grid and are used widely by planners to study the reliability of electricity supply. As energy systems transition away from the thermoelectric technologies that have traditionally balanced electricity supply and demand, hydropower and its representation in PCMs is of increasing importance. A limitation of PCMs applied to continental power grids with diverse generation portfolios is that hydropower generation is simulated without full consideration of complex river dynamics, leading to possible misrepresentation of grid flexibility and performance. In addition, data used in PCMs may reflect outdated operating policies. In this paper we propose a hydropower generation feasibility test for PCMs. The approach uses a detailed hydropower model to determine whether the hourly hydropower schedule from a PCM with simplified monthly parameterization can be attained after accounting for realistic river dynamics and operating policies, such as spill requirements and general water movement and balance through a cascade reservoir system. We perform this hydropower generation test for the ‘Big 10’ hydropower system on the Columbia River (part of the Western Interconnect of the United States), revealing 9% overestimation of available hydropower generation in a PCM solution in an average hydrologic year. Our evaluation provides insight on the cost and opportunities for better representing hydropower in PCMs.

54 ENVIRONMENTAL SCIENCES↗

An Integrated Paradigm for the Management of Delivery Risk in Electricity Markets: From Batteries to Insurance and Beyond [Slides]

In wholesale electricity markets today, flexibility from a limited number of distributed energy resources (DERs) is offered daily, and the value of flexibility is not yet recognized for economic hedging of delivery risk. Under a three-year project funded by the ARPA-E PERFORM program, a collaborative team is working towards developing an integrated risk management framework that will leverage flexibility from distributed and bulk resources to cost-effectively and reliably manage delivery risk of intermittent resources. Two concepts are at the core of the proposed integrated risk management framework: (A) flexibility options, which are a novel type of options and enable wholesale electricity market participants to hedge uncertainty by buying flexibility. (B) DER flexibility scores, which provide a way for utilities or aggregators to classify assets in groups with different likelihood of delivering contracted flexibility. This report presentation will focus on the proposed ISO-product "flexibility options," which is complementary to ramp and other products being introduced by ISOs/RTOs to manage net load uncertainties. Participating resources with imbalance risk can buy flexibility options to hedge their production, whereas grid-connected resources that can provide physical flexibility can offer flexibility options. We will present basics of the formulation for a day-ahead ISO market that matches buyers and sellers of this hedge in coordination with existing capabilities to schedule energy and ancillary services, and outline how their settlements mitigate the impact of imbalance risk.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Scalable Approach to Minimize Charging Costs for Electric Bus Fleets

Incorporating battery electric buses into bus fleets faces three primary challenges: a BEB’s extended refuel time, the cost of charging, both by the consumer and the power provider, and large compute demands for planning methods. When BEBs charge, the additional demands on the grid may exceed hardware limitations, so power providers divide a consumer’s energy needs into separate meters even though doing so is expensive for both power providers and consumers. Prior work has developed a number of strategies for computing charge schedules for bus fleets; however, prior work has not worked to reduce costs by aggregating meters. Additionally, because many works use mixed integer linear programs, their compute needs make planning for commercial-sized bus fleets intractable. This work presents a multi-program approach to computing charge plans for electric bus fleets. The proposed method solves a series of subproblems where the solution to the charge problem becomes more refined with each problem, moving closer to the optimal schedule. The results demonstrate how runtimes are reduced by using intermediate subproblems to refine the bus charge solution so that the proposed method can be applied to large bus fleets of 100+ buses. Not only will we demonstrate that runtimes scale linearly with the number of buses but we will also show how the proposed method scales to large bus fleets of over 100 buses while managing the monthly cost of energy.

Mortensen, Daniel (ORCID:0000000276494452)↗

Resource Selection Using Execution and Queue Wait Time Predictions

Computational grids provide users with many possible places to execute their applications. We wish to help users select where to run their applications by providing predictions of the execution times of applications on space shared parallel computers and predictions of when scheduling systems for such parallel computers will start applications. Our predictions are based on instance based learning techniques and simulations of scheduling algorithms. We find that our execution time prediction techniques have an average error of 37 percent of the execution times for trace data recorded from SGI Origins at NASA Ames Research Center and that this error is 67 percent lower than the error of user estimates. We also find that the error when predicting how long applications will wait in scheduling queues is 95 percent of mean queue wait times when using our execution time predictions and this is 57 percent lower than if we use user execution time estimates.

Warren, Smith↗

Resource Selection Using Execution and Queue Wait Time Predictions

Computational grids provide users with many possible places to execute their applications. We wish to help users select where to run their applications by providing predictions of the execution times of applications on space shared parallel computers and predictions of when scheduling systems for such parallel computers will start applications. Our predictions are based on instance based learning techniques and simulations of scheduling algorithms. We find that our execution time prediction techniques have an average error of 37 percent of the execution times for trace data recorded from SGI Origins at NASA Ames Research Center and that this error is 67 percent lower than the error of user estimates. We also find that the error when predicting how long applications will wait in scheduling queues is 95 percent of mean queue wait times when using our execution time predictions and this is 57 percent lower than if we use user execution time estimates.

Smith, Warren↗

On the operational characteristics and economic value of pumped thermal energy storage

Pumped thermal energy storage (PTES) systems use an electrically-driven heat pump to store electricity in the form of thermal energy, and subsequently dispatch the stored thermal energy to generate electricity using a thermodynamic heat engine. Optimal day-ahead operational scheduling and annual value of a PTES system based on Joule-Brayton thermodynamic cycles and two-tank molten salt hot thermal storage is evaluated in this work. Production cost models, which simultaneously optimize commitment and dispatch schedules for an entire set of generators to minimize the cost of satisfying electricity demand, are employed to determine system-optimal operation and day-ahead energy value of the PTES system within each of six hypothetical near-future grid scenarios intended to approximately represent the U.S. Western Interconnection or the Texas Interconnection. Sensitivity to grid scenario (including the contribution of variable renewable energy sources), thermal storage capacity, relative heat pump and heat engine capacities, and startup/shutdown cycling costs are evaluated. PTES energy value and heat engine annual capacity factor increase strongly as the contribution of variable renewable resources increases, heat pump capacity increases relative to heat engine capacity, or PTES cycling costs decrease. Grid scenarios in which the contribution of variable renewable energy is dominated by solar photovoltaics (PV) vs. wind produce inherently different PTES operational patterns. Annual PTES energy value within PV-dominated scenarios increased with storage capacity only up to approximately seven hours of full-load discharge capacity, whereas that within wind-dominated scenarios exhibited a continual increase with storage duration up to at least 16 hours.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Water Use Optimization Toolset Project: Development and Demonstration Phase Draft Report

This report summarizes the results of the development and demonstration phase of the Water Use Optimization Toolset (WUOT) project. It identifies the objective and goals that guided the project, as well as demonstrating potential benefits that could be obtained by applying the WUOT in different geo-hydrologic systems across the United States. A major challenge facing conventional hydropower plants is to operate more efficiently while dealing with an increasingly uncertain water-constrained environment and complex electricity markets. The goal of this 3-year WUOT project, which is funded by the U.S. Department of Energy (DOE), is to improve water management, resulting in more energy, revenues, and grid services from available water, and to enhance environmental benefits from improved hydropower operations and planning while maintaining institutional water delivery requirements. The long-term goal is for the WUOT to be used by environmental analysts and deployed by hydropower schedulers and operators to assist in market, dispatch, and operational decisions.

13 HYDRO ENERGY↗

Implementation and Operation of Power Flow Control Solutions for Transmission Systems

Power-flow controls (PFCs) technologies provide a suite of alternatives to more-efficiently direct the flow of power on the grid, improving flexibility and enabling the grid to be more responsive and resilient. PFCs can be used in many cases to mitigate overloads and consequently defer the installation of grid-expansion projects. They can also be suitable options in situations where new transmission lines cannot be built because of environmental constraints, land use, or other types of restrictions. Other uses include mitigation of loop or unintended flows, forcing of contractual or scheduled flows, reduction of congestion, and mitigation solutions during large maintenance or construction projects. While many studies have demonstrated the potential economic benefits of PFC for different types of applications, the implementation implications of using multiple PFCs for system operation and reliability have not been analyzed in detail. The lack of information and practical experience on these aspects hinders adoption of this technology. One use case would be that multiple PFCs are required to coordinate congestion management. In such cases, multiple PFCs are deployed in a meshed power system to control power flows across a wide area. The challenges are associated with PFC interaction—namely, the self and mutual power-flow sensitivity of each PFC, which must be accounted for in the calculation of the respective operating setpoints. This report analyzes implementation and operation that must be considered in evaluating transmission solutions using PFCs. The report first analyzes attributes with which PFC-based solutions should comply, based on the objective and characteristics of each particular use case. It then describes different approaches for coordinated control of multiple PFC devices for different applications, including options to avoid adverse interactions and reduce risks due to inappropriate coordination. Control and operation are illustrated through case studies performed on both generic and actual power system models. This report provides insights for transmission planners and operation engineers about the implementation of PFC-based transmission solutions; consequently, it will help them make informed decisions about the adoption of the technology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Force Limited Vibration Test of HESSI Imager

The High Energy Solar Spectroscopic Imager (HESSI) is a solar x-ray and gamma-ray observatory scheduled for launch in November 2000. Vibration testing of the HESSI imager flight unit was performed in August 1999. The HESSI imager consists of a composite metering tube, two aluminum trays mounted to the tube on titanium flexure mounts, and nine modulation grids mounted on each tray. The vibration tests were acceleration controlled and force limited, in order to prevent overtesting. The force limited strategy reduced the shaker force and notched the acceleration at resonances. The test set-up, test levels, and results are presented. The development of the force limits is also discussed. The imager successfully survived the vibration testing.

Amato, Deborah↗

Tools And Methods to Analyze Plant Outage Schedule and Assist Schedulers in Improving Outage Resilience

Refueling outages of nuclear power plants (NPPs) are considered one of the most critical phases throughout the plant lifetime. In such instances, tens of thousands of activities (e.g., maintenance, surveillance) are performed in a short amount of time (typically 2-3 weeks unless major backfitting or modernization projects are carried out) by a large number of crews (e.g., electricians, mechanics) that are hired as contractors. As a consequence, a plant outage can be expensive not only in terms of costs (e.g., contractor labor, material), but also in terms of loss generation since the plant is taken off the grid during the full outage duration (an indicative metric is about 1.2M$/day of loss of revenue). Thus, there is a continuous need to decrease the economic impact of outages on plant finances. This can be done by: decreasing the frequency of plant outages (e.g., from 18 to 24 months), reducing the time to complete the outage, and reducing the risk of outage delays. The Optimization of Outage Activities project under the Risk Informed Systems Analysis Pathway (RISA) sponsored by Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) Program focuses on developing tools and methods to support NPPs with outage schedule optimization. The developed tools and methods are designed to analyze plant outage schedule with the goal of identify critical elements in the schedule that might pose a high risk of delays. These methods and tools can be considered resource-centric in the sense that they address outage challenges as a resource optimization problem. In this context, resources are either time and crews; outage delays occurs when either (or both) resources are insufficient to complete the set of tasks assigned at a specific time instant of the outage. This report provides details on how plant resources (time and crews) can be allocated in such a way that delays are minimized. In this respect, two classes of methods have been developed: the first one focuses on the time resource and how variability of the time to complete outage tasks may impact outage delays. The second one integrates available resources to assess when dailies activities should be performed such that the risk of outage delays are minimized.

97 MATHEMATICS AND COMPUTING↗

Energy Management Policies in Distributed Residential Energy Systems

In this paper, we study energy management problems in communities with several neighborhood-level Residential Energy Systems (RESs). We consider control problems from both community level and residential level to handle external changes such as restriction on peak demand and restriction on the total demand from the electricity grid. We propose three policies to handle the problems at community level. Based on the collected data from RESs such as predicted energy load, the community controller analyzes the policies, distribute the results to the RES, and each RES can then control and schedule its own energy load based on different coordination functions. We utilize a framework to integrate both policy analysis and coordination of functions. With the use of our approach, we show that the policies are useful to resolve the challenges of energy management under external changes.

Duan, Sisi↗

Coupling thermal energy storage with a thermally anisotropic building envelope for building demand-side management across various US climate conditions

Here, the thermally anisotropic building envelope (TABE) is a novel active building envelope that enhances energy efficiency and thermal comfort in buildings by transferring heat and cold between building envelopes and hydronic loops. When coupled with thermal energy storage (TES) units, the TABE + TES enables the storage of both heat and cold energy captured by the TABE roof or exterior walls. This stored energy can be later released by the TABE floor for indoor heating and cooling, benefiting both the grid and the end user. This paper evaluates the merits of TABE + TES for building demand-side management across various US climate conditions, focusing on peak load shaving, annual energy savings, and cost savings under time-of-use (TOU) electric rate schedules. Simulations were conducted by integrating time-of-day–informed, rule-based control strategies in MATLAB, TABE components and TES units in COMSOL Multiphysics, and whole-building energy analysis in EnergyPlus. A case study using the US Department of Energy’s prototype single-family detached house model in Birmingham, Alabama; Los Angeles, California; Oak Ridge, Tennessee; and Denver, Colorado, showed that the TABE + TES system achieved (1) 70 % peak load shaving in Los Angeles and Denver and 20 % in Birmingham and Oak Ridge; (2) significant peak electricity savings of 351–497 kWh, reducing peak energy consumption by 38 %–78 %; and (3) annual heating cost savings of 0.79 $\$$/m2–1.17 $\$$/m 2 and cooling cost savings of 0.60 $\$$/m 2 –1.17 $\$$/m 2 using a normal utility rate or low-TOU rate. The benefits of employing the TABE + TES system are even more significant under high TOU rates.

25 ENERGY STORAGE↗

Coordinated platooning with multiple speeds

In a platoon, vehicles travel one after another with small intervehicle distances; trailing vehicles in a platoon save fuel because they experience less aerodynamic drag. This work presents a coordinated platooning model with multiple speed options that integrates scheduling, routing, speed selection, and platoon formation/dissolution in a mixed-integer linear program that minimizes the total fuel consumed by a set of vehicles while traveling between their respective origins and destinations. The performance of this model is numerically tested on a grid network and the Chicago-area highway network. We find that the fuel-savings factor of a multivehicle system significantly depends on the time each vehicle is allowed to stay in the network; this time affects vehicles’ available speed choices, possible routes, and the amount of time for coordinating platoon formation. For problem instances with a large number of vehicles, we propose and test a heuristic decomposed approach that applies a clustering algorithm to partition the set of vehicles and then routes each group separately. When the set of vehicles is large and the available computational time is small, the decomposed approach finds significantly better solutions than does the full model.

33 ADVANCED PROPULSION SYSTEMS↗

The ePIC Simulation Campaign Workflow on the Open Science Grid

The ePIC collaboration is realizing the first experiment of the future Electron-Ion Collider (EIC) at the Brookhaven National Laboratory that will allow for a precision study of the nucleons and the nucleus at the scale of sea quarks and gluons through the study of electron-proton/ion collisions. This paper will discuss the current workflow for running centralized simulation campaigns for ePIC on the Open Science Grid (OSG) infrastructure. This involves monthly releases of ePIC software and container deployments to CVMFS, generation of input datasets in HepMC format according to collaboration-defined policy, using Snakemake in CI/CD for validation and benchmarking, and submitting jobs to the OSG condor scheduler for opportunistic running on available resources. File transfers utilize XrootD, and Rucio is used for data management. The workflow is continuously refined to improve daily throughput (currently 50-100k core hours per day) and minimize job failures. Since May 2023, monthly simulation campaigns employing the workflow have cumulatively used over 20 million core hours on the OSG and produced over 350 TB of simulation data. The campaigns incorporate simulations for the broad science program of the EIC and are actively used for the detector and physics studies in preparation of the Technical Design Report (TDR).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Integrated Platform for Automated Sustainable Demand Response in Smart Grids

Demand Response(DR) is a common practice used by utility providers to regulate energy demand. It is used at periods of high demand to minimize the peak to average consumption ratio. Several methods have been Demand Response(DR) is a common praon using information about the baseline consumption and the consumption during DR. Our goal is to provide a sustainable reduction to ensure the elimination of peaks in demand. The proposed system includes an adaptation mechanism for when the provided solution does not meet the DR requirements. We conducted a series of experiments using consumption data from a real life micro grid to evaluate the efficiency as well as the robustness of our solution.

automated demand response↗