Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid analysis and integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Ensuring electromagnetic compatibility in grid-connected power converters: Challenges, standards, and compliance strategies

In today's rapidly advancing world, electronic devices and systems are fundamental to a wide range of industries, including renewable energy and global telecommunications infrastructure. However, as these devices become more complex and widespread, the risk of electromagnetic interference (EMI) also increases, underscoring the importance of stringent Electromagnetic Compatibility (EMC) requirements for maintaining system integrity. This paper addresses the specific challenges associated with grid-connected power converters (GCPCs), which are critical in integrating renewable energy into existing power grids. It explores the complexities of EMI in the context of GCPCs, particularly given the recent emergence of tailored EMC standards for these systems. The paper also highlights the shortcomings of applying generic or unrelated standards to GCPCs, often leading to inadequate compliance and testing protocols. Through a detailed analysis of existing standards and recent advancements in product-specific EMC requirements, this paper provides a comprehensive overview of the current landscape, offering guidance to stakeholders on navigating the intricate EMC compliance landscape, with a focus on methodologies, testing procedures, and the evolving regulatory environment for GCPCs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distribution Grid Impacts of Community Solar [Slides]

Community solar (CS) projects often face uncertain interconnection costs and fees associated with distribution grid infrastructure upgrades required to connect the project. These costs can determine the economic viability of a CS project, but they are difficult to assess. Cost uncertainty can discourage new projects and prevent communities from accessing the benefits of community solar projects. At the same time, CS deployment strategies hold potential to defer or avoid some distribution costs due to new loads. To mitigate CS interconnection costs, it is important to find least-cost combinations of distribution system infrastructure solutions (transformer upgrades, reconductoring, voltage regulators, storage), and to understand how location of CS projects within a feeder impact distribution grid upgrade costs. This study aims to quantify CS impacts on the distribution grid and provide policy and regulatory insights and CS deployment strategies to address them. It is the first analysis that has systematically studied the technical impacts of community solar projects on a wide range of distribution feeders using state-of-the-art optimization and power flow tools. The analysis employs Berkeley Lab’s novel Least-cost Optimal Distribution Grid Expansion (LODGE) model, a deterministic version of the REPAIR model, that optimally upgrades hundreds or even thousands of distribution circuits or feeders. This is the first application of the LODGE model. LODGE finds the least-cost portfolio of traditional distribution system upgrades to integrate CS in combination with alternative solutions, such as utility-owned storage and downsizing CS capacity. Working with a set of least-cost solutions per feeder allows us to benchmark, compare and find techno-economic trends in CS interconnection.

14 SOLAR ENERGY↗

Beyond Energy Efficiency: A clustering approach to embed demand flexibility into building energy benchmarking

The intermittency of carbon-free renewables and the demand changes associated with the widespread push for electrifying the transportation and building sectors provides an opportunity for buildings to go beyond energy efficiency and push towards providing demand flexibility to the electricity grid. The duality of energy efficiency and demand flexibility is necessary for success in a sustainable and reliable energy transition. Current building energy benchmarking models are limited in their ability to integrate concepts of demand flexibility and/or utilize granular smart meter data. Thus, current benchmarking methods are focused annual energy usage and fail to incorporate how the time of use of energy consumption impacts emissions in a quickly changing energy grid. Without a more comprehensive view of energy usage and associated real-time emissions, current benchmarking methods are unlikely to realize the full decarbonization potential of buildings. New emerging data streams provide an opportunity to develop a new generation of benchmarking energy models that embed dimensions of energy efficiency, grid interactivity, and demand flexibility into their analysis. In this paper, we propose a four-step method for embedding grid interactivity and demand flexibility into building benchmarking models that utilizes emerging building and time-series electricity data streams. We first engineer features to produce a mix-type dataset that encompasses many attributes of grid-interactive and efficient buildings, and then we apply K-medoids using Gower's Distance to produce peer-group clusters. We apply the method to a case study of 306 primary and secondary schools in southern California, USA. The results show that the method effectively clusters buildings by attributes of demand flexibility and energy efficiency. The clustering results reveal patterns in inefficient building operations and demand inflexibility at the building peer group level. In conclusion, the interpretation of clusters can serve as an integrated energy efficiency and demand flexibility benchmarking model and inform performance-specific policy targeting for buildings that go beyond traditional efficiency measures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Techno-Economic and Deployment Analysis of Fossil Fuel-Based Power Generation with Integrated Energy Storage

Most existing coal-fired power plants were designed for sustained operation at full load to maximize efficiency, reliability, and revenues. Depending on plant type and design, these plants can adjust output within a fixed range in response to plant or market conditions. The need for flexibility driven by increased penetration of variable and non-dispatchable power generation such as wind and solar is shifting traditional mission profile of thermoelectric power plants in three ways: more frequent shutdowns when market or grid conditions warrant, more aggressive load ramp rates (rate of output change), and lower minimum sustainable load, which provides a wider operating range and helps avoid costly plant shutdowns. The recent studies have shown that flexibility of a coal-fired power plant can be improved by the energy storage. The objective of this project was to analyze a set of energy storage options (technologies) and determine their impact on flexibility and economics of a representative coal-fired power plant. The effect of five Energy Storage Systems (ESSs) integrated with a coal power plant on plant flexibility and economics was investigated in this study. The results obtained in this project and presented in this report showed that ESS integrated with a thermal power plant improves plant flexibility and participation in the Energy and Ancillary Services markets and also improves plant financial performance.

20 FOSSIL-FUELED POWER PLANTS↗

Electrolyzers in the System Advisor Model (SAM): A Techno-Economic Potential Study

A technoeconomic analysis of grid to low temperature electrolysis (Grid-LTE), photovoltaic to low temperature electrolysis (PV-LTE), concentrating solar power to high temperature electrolysis (CSP-HTSE) and a concentrating solar power with PV to high temperature electrolysis (CSP-PV-HTSE) centralized hydrogen production systems are analyzed to assess the economics of system and to provide a baseline for comparing these technologies against hydrogen production cost targets. A framework integrating the system advisor model (SAM) and US Department of Energy hydrogen production models (H2A) is developed to assess these systems. The hydrogen levelized cost given current and future assumptions for technology cost and performance is evaluated at optimal system configurations. The framework described in this report integrates SAM with H2A electrolyzer technologies and provides analysts a detailed technoeconomic method to analyze concentrating and photovoltaic solar technologies to produce energy that are directly coupled to LTE and HTSEs that use that energy to split water into hydrogen and oxygen. The baseline hydrogen levelized cost (HLCs) for the GRID-LTE, PV-LTE, CSP-HTSE, and CSP-PV-HTSE systems in Daggett, CA are 2.82, 3.86, 3.68, and 2.90 $\$$USD 2016/kg H2 and 2.50, 2.13, 2.84, 2.15 $\$$USD 2016/kg H2 in the 2020 and 2050 scenarios respectively. To achieve the $\$$2/kg H2 target in locations with excellent solar resources, cost parameters values aligned with aggressive R&D targets will need to be achieved for all the systems configurations. In Daggett, PV costs of $\$$0.68 /Wac or moderate ATB PV CAPEX projections result in HLCs of $\$$2 /kg H2. Similarly for PV-MSALT-HTSE systems, $\$$0.60 /Wac result in $\$$2/kg H2. For the MSALT-HTSE systems, better than aggressive 2050 ATB salt tower CAPEX projections would be needed to reach $\$$2/kg H2. Molten salt tower capital costs of $\$$2400/kW would enable $\$$2/kg H2 in 2050.

08 HYDROGEN↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of Control System Functional Capabilities within the IES Plug-and-Play Simulation Environment

The concept of an Integrated Energy System (IES) is meant to combine different energy technologies in synergistic ways to achieve a more secure and economical energy supply. The RAVEN-based HYBRID framework is used to find the optimal installed capacity and the optimal economical dispatch of each component of the IES. A new RAVEN (Risk Analysis Virtual ENvironment) plugin for grid and capacity optimization (HERON) has been developed for optimizing the production variables of the IES given the demand profile. Currently, only the limits that affect the production variables and their corresponding time rates of change are considered (explicit constraints). However, other variables are additionally subject to constraints, but the associated limits are not accounted for (implicit constraints). In particular, for the power dispatch problem, the optimization algorithm takes into account the limits on the electrical power output and the corresponding hourly power variations but does not consider other constraints on process variables whose response effects the service life of the IES. This report describes a scheme that allows accounting for implicit constraints without increasing the size of the optimization problem. The Reference Governor (RG) algorithm is traditionally used for enforcing state and control constraints by modifying the set-point trajectories supplied to the feedback regulators. In our application, the RG is coupled within an iterative loop with the HERON-power dispatcher to generate optimal trajectories that ensure the operational constraints are met. A data-driven procedure to derive a representation of the dynamics of the controlled system was developed. First, the variables that represented the state of the system are selected (PCA-based approach), and then state-space representation matrices are derived from the collected measurements (DMDc algorithm). A preliminary version of the developed workflow based on Linear Time Invariant matrices was assessed by adopting a two-unit test case. More sophisticated versions of this workflow foreseeing the on-line derivation of system matrices will be deployed in FY 2021. Finally, a “plug-and-play” library of controllers and state observers was developed in Dymola. Some aspects of the current configuration of the IES unit components, e.g., the encapsulation of the control schemes into dedicated blocks, are consistent with the “plug-and-play” philosophy. Other features, e.g., the system buses collecting the input and the output variables, are not. For this reason, once listed and described the limits of the current configuration, necessary modifications to the plant model interface are presented. As a test-case, the interfaces of the SES model in the RAVEN-based HYBRID framework were reworked accordingly, and two different control schemes were applied to the same plant model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Recovery Simulator and Analysis Formulation: Mathematical Framework for Enhanced Resilience and Resource Allocation

This report introduces recovery simulator and analysis (RSA), a framework aimed at enhancing the resilience of electrical grids post-disruption. The RSA model leverages an optimization problem formulation that focuses on maximizing the load served (or optionally customers served) through a coordinated and cooptimized recovery of non-black start generation, transmission lines, feeders and substations subject to labor budget constraints. By integrating advanced linear programming techniques, the simulator selects efficient reocovery pathways, optimizing both short-term and long-term grid recovery strategies. The mathematical framework guides decision-making through a comprehensive evaluation of potential recovery actions, factoring in the trade-offs between labor constraints and load (or optionally customer) restoration efficacy. This enables grid operators to simulate diverse outage scenarios and delineate optimal recovery pathways, thereby prioritizing critical repair tasks and ensuring resource allocation is both economical and effective. The intended use case of RSA is to allow planners to explore many recovery scenarios quickly and determine assets most critical across a wide range of scenarios, and therefore strong candidates for hardening or additional investment. RSA might also be used in an operational setting, following a single event, for exploring efficient recovery pathways.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Turbulence-Resolving Simulations of Hurricane Laura (2020): Insights Into Extreme Winds and Eyewall Turbulence

Extreme weather events pose significant risks to coastal and offshore energy infrastructure. In this work, we investigate the structure of mean winds and turbulence near the surface ( z < 300 m) that occurred during Hurricane Laura in 2020 on the US Gulf Coast. To this end, we perform turbulence-resolving simulations (..delta..x = 33.33 m) that encompass the entire eyewall of Hurricane Laura by introducing a novel method that we will refer to as Moving-Mesoscale to Static-LES Integrated Coupling (MOSAIC). The simulation results are validated against surface, boundary-layer, and mid-tropospheric observations. Our analysis of the extreme wind conditions near the surface indicates that the mean wind and turbulence profiles vary greatly at and near the eyewall, resulting in extreme values of mean wind speed (U > 50 m * s-1) and turbulence kinetic energy (k ~ 50 m2 * s-2) at altitudes above 50 m . To investigate in detail the nature of turbulence within the eyewall of the storm, we conduct higher-resolution simulations (..delta..x = 11.11 m) of a portion of the hurricane. We provide a comprehensive statistical description of turbulence in the eyewall region, highlighting the need to employ ..delta..x ~ 10 m grid spacing to capture the integral length-scales near the surface, second- and higher-order central moments (i.e., skewness and kurtosis), and spectral coherence in the flow accurately. These numerical simulations provide the most detailed description of mean winds and turbulent conditions within the eyewall of a historical tropical cyclone to date, illustrating how high-resolution simulations can enhance limited turbulence measurements in hurricanes and giving insight into the extreme conditions threatening offshore and coastal infrastructure.

17 WIND ENERGY↗

Geothermal Energy and Resilience in Arctic Countries

The eight Arctic countries - Iceland, Canada, Denmark (Greenland and the Faroe Islands) Norway, Sweden, Finland, Russia, and the United States (Alaska) - have diverse energy systems, but can be split into two distinct groups based on energy characteristics. The first group includes systems in Europe (Finland, Norway, Sweden, and Iceland), which are heavily grid-connected. The second group includes the United States (Alaska), Canada, Russia, and Greenland, which have grid-connected energy systems in their more densely populated southern regions, but are also defined by the prevalence of remote microgrids. Energy sources for heat and power vary across grid-connected communities in the Arctic nations. The primary energy source for remote communities, on the other hand, is almost exclusively diesel. This is true for both heat and power. Despite these and other key distinctions, Arctic countries share many commonalities with regard to their energy systems. One is a fundamental need for heat. Heat and electric energy are linked in most communities - remote, rural, and urban - and those linked systems are increasingly vulnerable to disruptions. Several of the Arctic countries use baseload renewable energy resources for heat and power. Iceland uses geothermal and hydroelectric; Canada, the United States, Sweden, Norway, and Finland use hydroelectric. Utilization of baseload renewable energy resources on-site for combined heat and power appears to enhance the resilience of communities in Arctic countries with high penetration of those resources. On the other hand, reliance on diesel by remote communities in other Arctic countries may be amplifying vulnerabilities. Although geothermal energy is currently used in all eight Arctic countries, resources are poorly mapped, and details can be difficult to come by. Despite this, geothermal energy provides heat and sometimes electricity at both utility scales and at the microgrid scale. Geothermal electricity is produced in Iceland, Russia, and the United States (Alaska). Direct use of geothermal heat is used in Iceland, Russia, United States, Canada, and Norway. Geo-exchange is used in Sweden, Finland, Norway, Canada, and the United States. In this paper, we reframe geothermal heat and power systems as integrated energy systems, asking the question: are integrated geothermal energy systems - where available and economic - resilient solutions for communities in Arctic countries? We identify resilience attributes of integrated geothermal energy systems, with a focus on microgrids and small-scale applications. Based on the high-level, qualitative analysis presented in this paper, the answer appears to be yes. Further work should prioritize refining our understanding of geothermal resources in Arctic countries, because development of the most economic geothermal resources in Arctic countries has the potential to enhance the energy resilience of its residents, whether in a grid-connected or remote off-grid context.

15 GEOTHERMAL ENERGY↗

Unified analysis of finite-size error for periodic Hartree-Fock and second order Møller-Plesset perturbation theory

Despite decades of practice, finite-size errors in many widely used electronic structure theories for periodic systems remain poorly understood. For periodic systems using a general Monkhorst-Pack grid, there has been no comprehensive and rigorous analysis of the finite-size error in the Hartree-Fock theory (HF) and the second order Møller-Plesset perturbation theory (MP2), which are the simplest wavefunction based method, and the simplest post-Hartree-Fock method, respectively. Such calculations can be viewed as a multi-dimensional integral discretized with certain trapezoidal rules. Due to the Coulomb singularity, the integrand has many points of discontinuity in general, and standard error analysis based on the Euler-Maclaurin formula gives overly pessimistic results. The lack of analytic understanding of finite-size errors also impedes the development of effective finite-size correction schemes. We propose a unified analysis to obtain sharp convergence rates of finite-size errors for the periodic HF and MP2 theories. Our main technical advancement is a generalization of the result of Lyness [Math. Comp. 30 (1976), pp. 1–23] for obtaining sharp convergence rates of the trapezoidal rule for a class of non-smooth integrands. Our result is applicable to three-dimensional bulk systems as well as low dimensional systems (such as nanowires and 2D materials). Our unified analysis also allows us to prove the effectiveness of the Madelung-constant correction to the Fock exchange energy, and the effectiveness of a recently proposed staggered mesh method for periodic MP2 calculations (see X. Xing, X. Li, and L. Lin [J. Chem. Theory Comput. 17 (2021), pp. 4733–4745]). In conclusion, our analysis connects the effectiveness of the staggered mesh method with integrands with removable singularities, and suggests a new staggered mesh method for reducing finite-size errors of periodic HF calculations.

97 MATHEMATICS AND COMPUTING↗

Preliminary Component Design and Cost Estimation of a Novel Electric-Thermal Energy Storage System Using Solid Particles

Energy storage will become indispensable to complement the uncertainty of intermittent renewable resources and to firm the electricity supply as renewable power generation becomes the mainstream new-built energy source and fossil fuel power plants are phased out to meet carbon-neutral utility targets. Current energy storage methods based on pumped storage hydropower or batteries have many limitations. Thermal energy storage (TES) has unique advantages in scale and siting flexibility to provide grid-scale storage capacity. A particle-based TES system is projected to have promising cost and performance characteristics to meet the future growing energy storage needs. This paper introduces the system and components required for particle TES to become technically and economically competitive. The system integrates electric particle heaters, particle TES within insulated concrete silos, and an efficient air-Brayton combined-cycle power system to provide power for storage durations up to several days via low-cost, high-performance storage cycles. Design specifications and cost estimation of major components in a commercial-scale system are presented in this paper. A techno-economic analysis based on preliminary component designs and performance indicates that particle TES integrated with an air-Brayton combined-cycle power system has a path to achieve the targeted levelized cost of storage of 5 ¢/kWh-cycle at a round-trip efficiency of 50% when taking low-cost energy-specific components and leveraging basic assets from existing thermal power plants. The cost model provides insights for further development and economic potentials for long-duration energy storage.

14 SOLAR ENERGY↗

Opening the Door to Grid-Interactive Efficient Buildings with Energy Codes

Building codes represent standard design practice in the construction industry and must continually evolve to account for advancing technologies and innovative practices. Energy codes have historically focused on energy efficiency within buildings and across their systems. However, many of tomorrow's technologies go beyond efficiency and target increased flexibility. These demand flexibility (DF) measures can postpone or reduce building electric load based on price or other grid signals, and include smart appliances, connected lighting, and connected mechanical systems. Expanding codes to enable such grid-interactive efficient building (GEB) has the potential to influence their realization at scale, which will support renewable-energy grid-integration and building-sector decarbonization. However, considering DF measures in code development creates a new set of challenges for codes and the practices contained therein. This paper considers the role of building energy codes in enabling GEB. Specifically, it reviews the status of demand flexibility (DF) measures in current commercial building energy code. It examines the national model code development process and identifies components barring the consideration and inclusion of DF measures - including code scope, characterization and analysis of proposed new prescriptive measures, and accounting for time-of-day and geographic differences in their benefits. The paper presents findings from code development analyses that indicate the cost benefit of DF measures and the limitations associated with current code development conventions. To encourage building flexibility and improved energy resilience moving forward, recommendations are made for removing code development barriers and sanctioning DF measure consideration in future model codes.

Building Energy Codes and Standards, Grid-Interact↗

Enhancing Time Synchronization in Smart Grid With White Rabbit: Theory, Architecture, and Challenges

The smart grid aims to provide economically efficient and sustainable power to consumers with high quality and security. However, the increasing integration of distributed renewable energy sources presents challenges for smart grid protection and control systems. Here, to enhance smart grid operations, this article introduces White Rabbit (WR) as a more precise and accurate time synchronization technique. To explore White Rabbit’s potential applications in the smart grid, this study first explains existing time synchronization techniques and their limitations, followed by an analysis of the role and importance of time synchronization in smart grids. A comprehensive survey is then conducted, covering the theories, principles, implementations, performances, and existing application cases of White Rabbit. The findings suggest that White Rabbit is a promising technique for smart grid deployment. However, several challenges remain on the path to large-scale implementation. These challenges are analyzed in detail, highlighting key areas for future research.

Liu, Yu [University of Tennessee, Knoxville, TN (U↗

Preliminary Process and Instrumentation Design of Advanced Reactor Integration with Refineries and Hydrogen Production Facilities

With the ongoing push to decarbonize energy use and especially greenhouse gas emissions across all sectors, there are incentives to investigate how nuclear reactors may be used to generate clean energy and be used in various energy economies beyond just the electrical grid. Two initial integrations, high temperature steam electrolysis (HTSE) and oil refineries, are investigated in this first DOE Integrated Energy Systems (IES) program detailed industrial integration design report. Increasingly detailed reports are anticipated both for the industries discussed in this report and for additional industries in the future of the program. This report is a robust starting point showing how integration thermodynamic analysis establishes the requirements on the reactor and methods by which those requirements can be evaluated for specific reactor designs. Two Advanced Reactor Demonstration Program awardees are selected as representative designs for their respective technologies: NuScale for light-water reactors (LWRs) and X-Energy for high temperature gas reactors (HTGRs). Other reactor technologies or specific reactor configurations would require specific analysis similar to what is done in this report, thus this report can be a reference point by which to extend this work to other nuclear plant designs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Visualization Within the Department of Energy: NREL IEEE VIS Application Spotlight

This presentation highlights the role of advanced visualization techniques at the National Renewable Energy Laboratory (NREL) in supporting cutting-edge research across diverse energy domains. From immersive analytics and uncertainty visualization to high-resolution and real-time data analysis, NREL's visualization capabilities enable scientists to explore complex datasets more effectively. These tools are critical for advancing research in materials science, renewable energy technologies, biofuels, electric vehicle infrastructure, energy efficiency - from industrial processes to entire communities - and then bringing these innovations to practice through energy systems integration. NREL's visualization tools drive innovation across renewable energy and grid modernization efforts by providing deeper insights and improving decision-making.

grid modernization↗

Simulation of Reverse Osmosis Membrane Compaction Using Material Point Method (MPM)

Access to fresh drinking water in the future requires effective management of industrial wastewater and water purification from available resources. In this study, we present the simulation methodology and the analysis of a Reverse Osmosis (RO) membrane under various pressure conditions using the Material Point Method (MPM). In contrast to other numerical methods, MPM solves the continuum governing equations on material points in a Lagrangian framework. The method does not require a grid connecting the material points hence making it suitable to simulate large deformations during membrane compaction. The time integration is carried out using the explicit Euler method, while the spatial discretization is performed using linear or cubic-spline shape functions. A series of planar images containing detailed pore structures obtained from X-ray tomography experiments is converted to a three-dimensional collection of material points to simulate the membrane. Compressive loads are applied to the top layer of the membrane to simulate the experiments. The membrane deformation and pore size distribution before and after load application are reported and compared with the experimental measurements. The presentation discusses the numerical methods used, the performance of the solver on high-performance computing machines, and the results of membrane compaction in detail.

ENGINEERING,MATHEMATICS AND COMPUTING↗

An Open-Source Decarbonization Analytics Framework: Designing for Low-Carbon Emission Districts and Communities: Preprint

This paper introduces an open-source analytics framework designed to assist in creating low or net-zero carbon buildings and urban districts. Integrated within URBANopt, an open-source platform for energy analysis in districts and communities, this framework equips researchers, architects, engineers, and other stakeholders with tools to evaluate the carbon footprint implications of their design choices. The framework enables the analysis of various scenarios, incorporating both historical and future emission factors, and can span across different climate zones, each with distinct grid and emissions characteristics. The results showcase the framework's capability to evaluate the impact of design upgrades and control strategies on carbon emissions in districts and communities. An illustrative analysis using a hypothetical district in Denver, Colorado, shows reduced emissions from energy efficiency upgrades and control strategies, highlighting the sensitivity in their effects on emissions and energy use.

buildings energy efficiency↗