Lightweight, Fire-Resistant Graphite Composites

Aircraft safety improved with interior paneling made of new laminate with good thermophysical properties. Featuring lightweight graphite composite, laminate more heat-and flame-resistant and produces much less smoke in fire than commonly used epoxy-resin-containing laminates. New laminate prepared without epoxy resin. Graphite unidirectional cloth preimpregnated with blend of vinyl polystyrylpyridine and bismaleimide (VPSP-BMI). Either of two types of VPSP-BMI blend used, depending on method of preparation of chemicals and technique used to fabricate panel.

Kourtides, D. A.↗

Thermo-oxidative stability of graphite fiber/PMR-15 polyimide composites at 350 deg C

A series of graphite fiber/PMR-15 polyimide composites were subjected to isothermal aging at 350 C in flowing air (100 cc/min and 1000 cc/min) over a 520 hr time period. The graphite fibers were analyzed by ISS/SIMS techniques before composite fabrication. Fibers exposed at the surface of the composite due to the isothermal aging process were also analyzed by the ISS/SIMS method. Component and composite weight less studies were also conducted for similarly exposed materials. Optical micrograph investigations of composites to follow the progress of the thermo-oxidative process were also conducted. Flexural and interlaminar shear strengths of the imaged and aged composites were measured. The relationship of component and composite properties as they relate to the thermo-oxidative behavior of the materials was discussed.

Scola, D. A.↗

The 737 graphite composite flight spoiler flight service evaluation

The flight service experience of 111 graphite-epoxy spoilers on 737 transport aircraft and related ground based environmental exposure of graphite-epoxy material specimens is covered. Spoilers have been installed on 28 aircraft representing seven major airlines operating throughout the world. An extended flight service evaluation program of 15 years is presently underway. As of December 1984, a total of 2,092, 155 spoiler flight hours and 2,954,814 spoiler landings had been accumulated by this fleet.

Coggeshall, R. L.↗

Theoretical and experimental investigation of the destruction of graphites in a flow of dissociated air

A method is presented for calculating the heating and erosion of blunt bodies made of graphite in a high-enthalpy flow of dissociated air, assuming chemical equilibrium on the surface and taking account of the thermal effects of combustion and sublimation of graphite. The analysis involves the use of a finite difference scheme to solve an equation of unsteady heat conduction. Attention is given to the equilibrium vaporization of C, C2 and C3 molecules. The calculations agree well with experimental data for a wide range of temperatures and stagnation pressures.

Bovina, T. A.↗

The milling of pristine and brominated P-100 graphite fibers

Techniques were developed for the ball milling of pristine and brominated P-100 graphite fibers. Because of the lubrication properties of graphite, large ball loads (50 percent by volume) were required. Use of 2-propanol as a milling medium enhanced the efficiency of the process. Milled brominated P-100 fibers had resistivities which were indistinguishable from milled pristine P-100 fibers. Apparent loss of bromine from the brominated fibers suggests that bromine would not be the intercalate of choice in applications where milled fibers of this type are required. Other intercalates which do not degas may be more appropriate for a milled fiber application. These same results, however, do provide evidence that bromine molecules leave the fiber surface when removed from overpressure of bromine. While exploring possible solvent media for milling purposes, it was found that brominated fibers are stable in a wide variety of organic solvents.

Dillehay, M. E.↗

New bismaleimide matrix resins for graphite fiber composites

Two new bismaleimide resins based on the N, N'-m-phenylene-bis(m-amino-benzamide) structure have been synthesized and characterized. The mixtures of the two resins gave better handling, processing, mechanical, and thermal properties in graphite composites than did the individual resins. The mechanical strength of the cured graphite composites prepared from the 1:1 copolymer of the two bismaleimide resins was excellent at both ambient and elevated temperatures. The physical and mechanical properties of the composites from the new bismaleimide matrix resin systems are compared with conventional composites based on epoxy and other bismaleimide systems. The copolymer system provides another method for improving bismaleimide resins.

Hsu, M.-T. S.↗

Tribological properties of graphite-fiber-reinforced, partially fluorinated polyimide composites

Graphite-fiber-reinforced polyimide (GFRPI) composites were formulated from three new partially fluorinated polyimides and three types of graphite fiber. Nine composites were molded into pins and evaluated in a pin-on-disk tribometer. Friction coefficients, wear rates, pin wear surface morphology, and transfer film formation were assessed at 25 and 300 C. Also assessed was the effect of sliding speed on friction. Wear was up to two orders of magnitude lower at 25 C and up to one order of magnitude lower at 300 C than with previously formulated NASA GFRPI composites.

Fusaro, R. L.↗

Drop testing and analysis of six-foot diameter graphite-epoxy frames

Graphite-epoxy frames were drop tested onto a concrete floor to simulate crash loadings. The frames have Z-shaped cross-sections typical of designs often proposed for fuselage structure of advanced composite transports. The 6-foot diameter of the frames was chosen to reduce specimen fabrication costs and to facilitate testing. Response of the frames from accelerometer, strain gage, and photographic measurements are presented which characterize the behavior under 25-30 fps vertical impact velocity onto concrete. Failure of the graphite-epoxy frames involved a complete separation through the cross section near the impact point. All damage to the composite frame was confined to an area close to the impact point. Failure of aluminum frames tested for comparison were different from the composite specimens. The aluminum frames yielded (plastic hinges formed) at several locations around the lower portion of the frame without failing completely across the section.

Boitnott, R. L.↗

Carbon monoxide production in low energy oxygen ion bombardment of pyrolytic graphite and Kapton surfaces

The results of an investigtion of the interaction of low energy oxygen ions with pyrolytic graphite and Kapton surface are reported. CO molecules emitted from the surface as a result of the ion bombardment were detected by a mass spectrometer. Because the ion-induced signals were small compared to that arising from the CO background pressure in the vacuum system, the ion beam was modulated and the modulated component of the CO signal measured with a lock-in amplifier. The quantum yield (CO molecules emitted per incident oxygen ion) for graphite rose from 1.9 at 4.5 eV ion energy to 6.6 at 465 eV. Comparable yields were obtained for Kapton. The large size of the yields suggests contributions to the reaction process from the background O2 molecules in the vacuum system.

Horton, C. C.↗

Experimental evaluation of damping of graphite fiber composites

An investigation is described that was conducted to measure the damping of graphite fiber composites such as are to be used on the Hubble Space Telescope. The measurements were made on a composite cylinder under normal atmospheric conditions and in a vacuum chamber with varying thermal conditions. Such composites can outgas under vacuum conditions and this emission of trapped gases may have some influence on the material damping. Some results are presented for the damping coefficient measured under normal atmospheric conditions for a graphite fiber composite. The experimental damping data thus obtained were compared with the least square estimate obtained through a statistical analysis. The statistical analysis was based on a linear mathematical model consisting of a spring in parallel with a dashpot. It is observed that the discrepancy in the damping ratio between logarithmic decrement result and the least square fit is less than 6 percent for all the different tests made on the composite cylinder. Signal-to-noise ratio was maintained to be greater than 10.

Rao, M. D.↗

A heater made from graphite composite material for potential deicing application

A surface heater was developed using a graphite fiber-epoxy composite as the heating element. This heater can be thin, highly electrically and thermally conductive, and can conform to an irregular surface. Therefore it may be used in an aircraft's thermal deicing system to quickly and uniformly heat the aircraft surface. One-ply of unidirectional graphite fiber-epoxy composite was laminated between two plies of fiber glass-epoxy composite, with nickel foil contacting the end portions of the composite and partly exposed beyond the composites for electrical contact. The model heater used brominated P-100 fibers from Amoco. The fiber's electrical resistivity, thermal conductivity and density were 50 micro ohms per centimeter, 270 W/m-K and 2.30 gm/cubic cm, respectively. The electricity was found to penetrate through the composite in the transverse direction to make an acceptably low foil-composite contact resistance. When conducting current, the heater temperature increase reached 50 percent of the steady state value within 20 sec. There was no overheating at the ends of the heater provided there was no water corrosion. If the foil-composite bonding failed during storage, liquid water exposure was found to oxidize the foil. Such bonding failure may be avoided if perforated nickel foil is used, so that the composite plies can bond to each other through the perforated holes and therefore lock the foil in place.

Hung, C. C.↗

The 737 graphite composite flight spoiler flight service evaluation

The ninth flight service report was prepared in compliance with the requirements of Contract NAS1-11668. It covers the flight service experience of 111 graphite-epoxy spoilers on 737 transport aircraft and related ground-based environmental exposure of graphite epoxy material specimens for the period 1 Jan. 1985 through 31 Dec. 1986. Spoilers have been installed on 28 aircraft representing seven major airlines operating throughout the world. An extended flight service evaluation program of 15 years is presently underway. As of 31 Dec. 1986, a total of 3,339,608 spoiler flight-hours and 3,320,952 spoiler landings had been accumulated by this fleet.

Coggeshall, Randy L.↗

A heater made from graphite composite material for potential deicing application

A surface heater was developed using a graphite fiber-epoxy composite as the heating element. This heater can be thin, highly electrically and thermally conductive, and can conform to an irregular surface. Therefore it may be used in an aircraft's thermal deicing system to quickly and uniformly heat the aircraft surface. One-ply of unidirectional graphite fiber-epoxy composite was laminated between two plies of fiber glass-epoxy composite, with nickel foil contacting the end portions of the composite and partly exposed beyond the composites for electrical contact. The model heater used brominated P-100 fibers from Amoco. The fiber's electrical resistivity, thermal conductivity and density were 50 micro ohms per centimenter, 270 W/m-K and 2.30 gm/cubic cm, respectively. The electricity was found to penetrate through the composite in the transverse direction to make an acceptably low foil-composite contact resistance. When conducting current, the heater temperature increase reached 50 percent of the steady state value within 20 sec. There was no overheating at the ends of the heater provided there was no water corrosion. If the foil-composite bonding failed during storage, liquid water exposure was found to oxidize the foil. Such bonding failure may be avoided if perforated nickel foil is used, so that the composite plies can bond to each other through the perforated holes and therefore lock the foil in place.

Hung, Ching-Cheh↗

A study of the damping capacity of graphite epoxy composites in a vacuum

The damping properties of a graphite epoxy composite material (used in the construction of the Hubble Space Telescope) are measured under a variety of conditions in a vacuum chamber to simulate conditions in space. An improved method is proposed which utilizes several points of the response curve near a resonance to estimate the damping ratio and the undamped resonance frequency. The damping of a graphite epoxy tube is monitored for four weeks to study moisture desorption and temperature effects. A significant variation is observed in the damping ratio with temperature.

Rao, Mohan D.↗

C-13 N.M.R. study of charge transfer in alkali metal-ammonia graphite compounds

The usefulness of C-13 NMR spectroscopy and chemical shift for the study of charge transfer in graphite intercalation compounds is demonstrated. A linear relationship is established between the chemical shifts and the square root of the absolute value of the electronic charge per carbon atom. The method is applied to the ternary alkali metal-ammonia-graphite compounds. Weak solvations of electronic charges by ammonia are observed.

Tsang, T.↗

Mechanical and electrical properties of graphite fiber-epoxy composites made from pristine and bromine intercalated fibers

The mechanical and electrical properties of pristine and bromine intercalated graphite fiber-epoxy composites were compared. The two types of composite were similar in terms of tensile modulus, tensile strength, and Poisson's Ratio. However, the interlaminar shear strength of the brominated composite was 18 percent greater than its pristine counterpart. Only slight differences were observed in flexural properties. A five-fold decrease was observed in the electrical resistivity of the brominated composite parallel to the axis of the fibers, resulting in a unidirectional resistivity of about 90 microOmega/cm. Transverse resistivity was unaffected. Both types of composite were subjected to a simulated lightning strike of 10 KJ (at a peak current of 150 kA), and the composite with the intercalated graphite exhibited less damage.

Jaworske, Donald A.↗

Fabrication and testing of fire resistant graphite composite panels

Eight different graphite composite panels were fabricated using four different resin matrices. The resin matrices included Hercules 71775, a blend of vinylpolystyrpyridine and bismaleimide, H795, a bismaleimide, Cycom 6162, a phenolic, and PSP 6022m, a polystyrylpyridine. Graphite panels were fabricated using fabric or unidirectional tape. Described are the processes for preparing these panels and some of their mechanical, thermal and flammability properties. Panel properties are compared with state-of-the-art epoxy fiberglass composite panels.

Roper, W. D.↗

Performance of a small, graphite electrode, multistage depressed collector with a 500-W, continuous wave, 4.8- to 9.6-GHz traveling wave tube

A small, isotropic graphite multistage depressed collector (MDC) and a short permanent magnet refocuser were designed, fabricated, and evaluated in conjunction with a 500-W, continuous-wave (CW), 4.8 to 9.6 GHz traveling wave tube (TWT). A novel performance optimization system and technique were used to optimize the TWT-MDC performance for saturated broad-band operation. The MDC performance was evaluated in both four- and three-stage configurations. Average TWT overall and four-stage collector efficiencies of 43.8 and 82.6 percent, respectively, were obtained for saturated octave-bandwidth operation. The isotropic graphite electrode material performed well, and shows considerable promise. However, considerably more test experience is required before definitive conclusions on its suitability for space and airborne TWT's can be made.

Ramins, Peter↗