At least 325 records · Page 18

Quantum for Energy Systems and Technologies

Quantum information science (QIS) is creating a transformative opportunity to improve processes for energy production, distribution, and consumption. In this presentation, we will show the works that are currently pursued into two major directions, (i) quantum sensing and (ii) quantum computing is undergoing in order to find applications in the areas of carbon captures, critical minerals and gas sensing applications.

Paudel, Hari P.↗

Environmental, Health and Safety Assessment Application of a Heat Integrated, Post-combustion CO2 Capture System Using Monoethanolamine and Hitachi H3-1 Solvent at the E.W. Brown Coal-fired Power Plant

An Environmental Health and Safety (EH&S) Assessment was completed for operation of a pilot scale carbon dioxide (CO2) capture system (CCS) at the Louisville Gas & Electric (LG&E) and Kentucky Utilities (KU) Energy, LLC (LG&E-KU) E. W. Brown Generating Station in Harrodsburg, Mercer County, Kentucky. The pilot system was evaluated using two CO2 capture solvents, monoethanolamine (MEA) and Hitachi’s H3-1 solvent. The purpose of the EH&S Assessment was to determine if there were any unacceptable environmental, health or safety concerns that may prevent operation or environmental permitting of a larger scale pilot scale plant. The assessment included review of process flow diagrams, input and output flow rates for primary materials, literature describing similar processes and chemicals used or created during the process, actual air emission and wastewater test data and air emission calculations. The evaluation included identification of risks related to hazardous chemicals, air emissions, wastewater discharges, solid wastes generated and employee hazards. Most potential EH&S issues that were identified are commonly found and successfully managed at large industrial facilities. No risks were identified that could not be successfully managed or would likely prevent implementation or environmental permitting of the pilot or larger scale plant. Potential exposures and resulting health risks from exposure to low concentrations of nitrosamines generated from degradation of the Hitachi H3-1 and possibly MEA solvents may be a health concern for site workers, but additional investigation is needed to accurately assess this risk. Applying the information gained from operating the pilot plant, performing air emission testing and used solvent testing to a large-scale facility at a commercial coal-fired electric generating plant suggests additional air emission control measures may be necessary to reduce potential site worker health risks and possibly community risks. Depending upon the location and regional air quality, considerable effort may be required to obtain the necessary air permit for construction and operation of a similarly configured large-scale PCCCS facility.

gas separation↗

Environmental, Health and Safety Assessment Application of a Heat Integrated, Post-combustion CO 2 Capture System Using Monoethanolamine and Hitachi H3-1 Solvent at the E.W. Brown Coal-Fired Power Plant

An Environmental Health and Safety (EH&S) Assessment was completed for operation of a pilot scale carbon dioxide (CO 2 ) capture system (CCS) at the Louisville Gas & Electric (LG&E) and Kentucky Utilities (KU) Energy, LLC (LG&E-KU) E. W. Brown Generating Station in Harrodsburg, Mercer County, Kentucky. The pilot system was evaluated using two CO 2 capture solvents, monoethanolamine (MEA) and Hitachi’s H3-1 solvent. The purpose of the EH&S Assessment was to determine if there were any unacceptable environmental, health or safety concerns that may prevent operation or environmental permitting of a larger scale pilot scale plant. The assessment included review of process flow diagrams, input and output flow rates for primary materials, literature describing similar processes and chemicals used or created during the process, actual air emission and wastewater test data and air emission calculations. The evaluation included identification of risks related to hazardous chemicals, air emissions, wastewater discharges, solid wastes generated and employee hazards. Most potential EH&S issues that were identified are commonly found and successfully managed at large industrial facilities. No risks were identified that could not be successfully managed or would likely prevent implementation or environmental permitting of the pilot or larger scale plant. Potential exposures and resulting health risks from exposure to low concentrations of nitrosamines generated from degradation of the Hitachi H3-1 and possibly MEA solvents may be a health concern for site workers, but additional investigation is needed to accurately assess this risk. Applying the information gained from operating the pilot plant, performing air emission testing and used solvent testing to a large-scale facility at a commercial coal-fired electric generating plant suggests additional air emission control measures may be necessary to reduce potential site worker health risks and possibly community risks. Depending upon the location and regional air quality, considerable effort may be required to obtain the necessary air permit for construction and operation of a similarly configured large-scale PCCCS facility.

gas separation↗

Amine Oxidation Catalyzed by NO 2

Amine oxidation is a major risk in the deployment of amine scrubbing for CO2 capture from post-combustion flue gas. Oxidation probably occurs by dissolved oxygen at elevated temperature, Fe(III)/Fe(II) shuttling between the absorber and the stripper, and by NO2 in the absorber. Amine selection, dissolved oxygen removal, and solvent reclaiming mitigate oxidation due to dissolved oxygen and iron shuttle mechanism, but not by NO2. This work examines piperazine (PZ) oxidation by NO2 in a bench-scale high gas flow reactor (HGF). PZ is an effective second-generation solvent with high CO2 capacity, fast capture rate, good thermal stability, and good resistance to oxidation. Flue gas typically contains 0.5–5 ppm NO2 and 10–100 ppm NO. NO2 at 1 ppm in the flue gas appears to cause significant amine oxidation in pilot plant testing. PZ solution can easily absorb NO2, and it is hypothesized that NO2 can catalytically oxidize PZ through free-radical propagation. The issue may not be solved by a NO2 pre-scrubber since the coexistence of NO and O2 in the flue gas will keep producing non-negligible amounts of NO2 in the ductwork and the absorber after the NO2 incoming with the flue gas has been scrubbed. In addition, NO2 may not only oxidize PZ but also the intermediate degradation products, and it is unknown if the existence of dissolved iron influences the oxidation by NO2. Previous workers have also shown that NO2 is the stoichiometric source of nitrosamine. A comprehensive analysis of NO2 oxidation is needed to address solvent management and its health/environmental impact. The new high gas flow (HGF) reactor focuses only on the absorber environment and is simpler to interpret because it does not include oxidation at high temperatures and by dissolved metal catalysts from corrosion. This paper presents the results of HGF experiments and shows evidence to support a hypothesis of amine oxidation catalyzed by NO2, presents the synergic effect of NO2 and iron on amine oxidation, points out the different effects of NO2 in clean and degraded solvents, and demonstrates that NO2 not only can oxidize amines but also their degradation products.

NO2, iron, piperazine (PZ), solvent oxidation, sol↗

Analysis of energetics and economics of sub-ambient hybrid post-combustion carbon dioxide capture

Adsorption of CO 2 from post-combustion flue gas is one of the leading candidates for globally impactful carbon capture systems. In this report, work focused on understanding the opportunities and limitations of sub-ambient CO 2 capture processes utilizing a multistage separation process. A hybrid process design using a combination of pressure-driven separation of CO 2 from flue gas (e.g., adsorption- or membrane-based separation) followed by CO 2 -rich product liquefaction to produce high-purity (>99%) CO 2 at pipeline conditions is considered. The operating pressure of the separation unit is a key cost parameter and also an important process variable that regulates the available heat removal necessary to reach the sub-ambient operating conditions. The economic viability of applying pressure swing adsorption (PSA) processes using fiber sorbent contactors with internal heat management was found to be most influenced by the productivity of the adsorption system, with productivities as high as 0.015 mol CO2 /kg sorb -1 sec -1 being required to reduce costs of capture below $60/ton CO 2 captured. This analysis was carried out using a simplified two-bed process, and thus there is opportunity for further cost reduction with exploration of more complex cycle designs. Three exemplar fiber sorbents (MIL-101(Cr), UiO-66, and zeolite 13X) were considered for application in the sub-ambient process of PSA unit. Among the considered sorbents, zeolite 13X fiber composites were found to perform better at ambient temperatures as compared to sub-ambient. MIL-101(Cr) and UiO-66 fiber composites had improved purity, recovery, and productivity at colder temperatures reducing costs of capture as low as $61/ton CO 2 . Future economic improvement could be achieved by reducing the required operating pressure of the PSA unit and pushing the Pareto frontier closer to the final pipeline requirement via a combination of PSA cycle design and material selection.

42 ENGINEERING↗

Pollution to products: recycling of ‘above ground’ carbon by gas fermentation

Climate crisis and rapid population growth are posing some of the most pressing challenges to mankind and have intensified the need for the deployment of carbon recycling and carbon capture and utilization (CCU) technologies. Gas fermentation offers a solution using carbon-fixing chemolithoautotrophic microorganisms. After a decade of scale up, the technology has recently been commercialized with the first plant operating successfully since 2018 and additional units under construction. Gas fermentation offers unique feedstock and product flexibility when compared to other available gas-to-liquid technologies. Advancements in process technology and synthetic biology enable a broad range of feedstocks including emissions from industry or syngas generated from any biomass resource to be converted into a wide range of molecules realizing a circular economy.

09 BIOMASS FUELS↗

Characterization of Oxy-Coal Swirl Injector

The article presents the design and testing of a coal-slurry swirl-pintle injector for high pressure oxy-coal combustion systems. Pressurized oxy-coal combustion-based systems have the potential to improve efficiency by recovering latent heat of the steam in flue gas and achieve 90% CO2 capture. In oxy-coal combustion, coal is burned in the presence of pure oxygen, which results in higher efficiency and less greenhouse gas in the exhaust. With the advancement of pressurized oxy-coal combustor research, there is a need to investigate injector technology suitable for this unique combustion approach. Effective atomization and mixing of coal-slurry and oxidizer pose a challenge for the efficient burning of coal particles. A swirl-pintle type injector was designed and tested to enhance the atomization of the coal-water slurry spray by adding a swirl to the oxygen flow path. Although pintle type injectors are traditionally used in rocket engines, they present a promising approach in clean coal combustion technology due to higher mixing effectiveness and enhanced performance. The mixing behavior of three pintle injectors with different swirl numbers (S = 0, 0.9, and 1.2) was tested using a high-speed shadow sizing technique. Mixture ratios of 30% (by mass) coal-water slurry were studied. The droplet diameter and dispersion characteristics were determined from shadow images of coal-water spray. The jet breakup length, droplet number, total moment ratio (TMR), and Ohnesorge number were then calculated to compare the performance of different injectors. The paper presents an empirical correlation of the TMR with droplet size and spray regimes. For a pintle injector with S = 1.2 swirler, the droplets diameter was found to be in the range of 1 mm to 12 mm. The jet breakup length was also shorter in comparison to S= 0 and 0.9 injectors. A second atomization zone was also observed at 2 and 5 diameters downstream of injector exist at spray edge and jet core respectively

01 COAL, LIGNITE, AND PEAT↗

Research goals for minimizing the cost of CO 2 capture when using steam methane reforming for hydrogen production

This paper presents a techno-economic assessment of adding state-of-the-art solvent-based CO 2 capture technologies to greenfield steam methane reforming (SMR)-based H 2 production plants and quantifies the impacts of improvements in CO 2 capture technology. Current conventional capture technologies are reviewed, and future technologies in intermediate and long-term scenarios are analyzed. The results show that adding significantly more efficient solvent-based capture technologies leads to an equivalent rate of natural gas consumption as that of a conventional SMR plant without capture, despite capturing most of the CO 2 and producing the same amount of H 2 . Overall, improvements in reboiler duty and reductions in capital costs can significantly reduce the cost of H 2 production and cost of capture. Particularly, the reboiler duty of pre-combustion capture and the capital cost of post-combustion capture have the greatest impact. Based on the results, research goals are suggested. Solvent development is recommended—particularly pre-combustion solvents—for reducing the reboiler duties, and process schemes to reduce the capital costs. Costlier but more efficient solvents can be considered. A sensitivity analysis using natural gas price shows that technological improvements can reduce the impacts of high natural gas prices. The degree of economic feasibility of CO 2 capture increases with improvements to the capture technology.

08 HYDROGEN↗

Krypton Concentration using HZ-PAN

Idaho National Laboratory (INL) has developed and tested engineered sorbents to separate and capture volatile fission products such iodine, xenon (Xe), and krypton (Kr) from off-gas streams. As noble gases, Xe and Kr can be difficult to capture and separate. Historically, cryogenic distillation has been used to execute the separation. However, performing this separation from bulk air streams is expensive and can pose significant hazards. INL has successfully developed two different sorbents for Xe and Kr capture, silver mordenite polyacrylonitrile and hydrogen mordenite polyacrylonitrile (HZ-PAN). Adsorption studies to date successfully separated and captured Kr from carrier gas streams, but those studies focused primarily on initial separation and capture. Successful utilization in a used nuclear fuel (UNF) reprocessing facility, however, requires further concentration of the Kr to minimize long term storage volumes. This study focuses on the concentration of Kr utilizing HZ PAN as the concentrating media. Concentrating Kr during desorption is ideal for two reasons: one, to produce Kr that can be used for commercial and research applications, or two, to minimize the volume of the radioactive gaseous waste stream for disposal. This report investigates the Kr concentrating potential of HZ-PAN by running multiple Kr adsorption-desorption cycles, collecting the desorbed effluent from a saturated HZ-PAN column, and loading it onto a fresh column. This study demonstrates that four adsorption-desorption cycles can transform a 150 ppmv Kr stream into a 37.5% Kr stream, an overall concentration factor of 2497. Each concentration step results in successively smaller volumes desorbed, reducing volume by a factor of approximately 40,000. Depending on the operational goals, during desorption one could collect smaller volume fractions of high concentration Kr (~ 67%). This demonstration should be considered proof-of-concept. Further refinement is necessary to develop optimum operating schemes to integrate into UNF off-gas treatment.

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE↗

Direct Air Capture of CO 2 and Delivery to Photobioreactors for Algal Biofuel Production (Final Report)

A mobile DAC system was designed and constructed to pair with photobioreactors growing algae for biofuel production. The DAC system was designed as a versatile research system, rather than a compact production unit. The system was constructed and mounted on a mobile skid to facilitate transportation to the algae production site. Within the DAC system, CO 2 was captured using amine-loaded monoliths that allow for high CO 2 uptake with low pressure drop. The CO 2 is collected using a Global Thermostat patented temperature/vacuum swing adsorption (TVSA) process. Amine sorbents and process conditions were optimized to produce 10 to >20 g CO 2 .h-1. The stability of the amine sorbents was also studied, with sorbent modifications made to improve stability to degradation by oxidation. An Algenol-developed Spirulina strain (Arthrospira platensis AB2293) was selected as the production cyanobacterial strain. AB2293 cultured was inoculum for outdoor production following PBR installation by Algenol. The PBR system was composed of three independent PBRs, with each PBR composed of four hanging bags internally recirculated by a liquid turnover pump. The PBRs were operated outdoors in Atlanta, GA, and integrated with the DAC system. Algae were grown with similar productivity using DAC-CO 2 as algae grown using pure CO 2 obtained commercially (Airgas). Throughout the experimental duration, no discoloration was observed, and cellular morphology was consistent between the two experimental treatments. An LCA including lifecycle greenhouse gas emissions, full life cycle inventory of the Algenol system and the DAC system and integrated DAC+PBR system was developed. Lifecycle greenhouse gas emissions were calculated for capture of carbon dioxide using input from Global Thermostat and the National Renewable Energy Laboratory. Three scenarios for energy provision were evaluated: a natural gas combined heat and power system sized to meet the electricity requirement, a natural gas combined heat and power system sized to meet the process heat requirements, and a system without on-site power that procures the electricity from the grid. In all three cases, as expected, the major contributor to the emissions is the energy consumption associated with the desorption step of the DAC process. The LCA quantified the reduced potential energy and greenhouse gas emissions of heat and mass integration of DAC and Algenol compared to unintegrated DAC and Algenol systems. A life cycle assessment of the role of sorbent productivity and lifetime was also developed. The development of more robust, oxidation resistant DAC sorbents may enable small reductions in energy requirements and in lifecycle greenhouse gas emissions and other environmental impacts. NREL performed techno-economic analysis (TEA) to identify the integration scenario most likely to achieve a 15% cost reduction target versus the baseline. Heat and mass integration of DAC and the PBR is critical to minimizing the MFSP. The baseline case utilizes no heat and mass integration, and the DAC system provides 100% of the CO 2 required by the photobioreactors (20 tonnes/hr), operating for 12 hours/day capturing 40 tonnes CO 2 /operating hour. The minimum fuel selling price (MFSP) of ethanol calculated from the baseline case was $10.68/gal ethanol. This corresponds with a targeted MFSP of $9.07/gal ethanol (or 15% reduction). This target was achieved by integration Option 2a with the greatest cost reduction of 17.8% (or $8.78/gal) and integration Option 2b with a cost reduction of 16.4% (or $8.93/gal). Reductions in MFSP are attributed to two primary process considerations: (a) CO 2 storage at night reduces the capital expenses associated with DAC (i.e., increasing on-stream time); and (b) distributed DAC scenarios (DAC-PBR integration Options 2a and 2b) make use of boiler and DAC CHP flue gas CO 2 (free). Direct air capture on-stream time was one of the largest contributors to MFSP reduction.

09 BIOMASS FUELS↗

A Membrane Contactor Enabling Energy-Efficient CO 2 Capture from Point Sources with Deep Eutectic Solvents

We demonstrate a scalable and energy-efficient hollow fiber membrane contactor (HFMC)-based process using a green solvent for CO 2 capture. This process uses a deep eutectic solvent (DES) in an HFMC to provide close interfacial interactions and contact between the DES and CO 2 . This approach overcomes disadvantages associated with direct absorption in DES and could potentially be applied to a variety of solvent-based CO 2 capture methods. Commercial low-cost polymer hollow fiber membranes (e.g., microporous polypropylene) were evaluated for CO 2 capture with reline, a prototypical DES. Single-gas measurements showed that the DES-based polypropylene HFMC can capture and separate CO 2 while rejecting N2. From a mixed gas containing 50 mol % N 2 and 50 mol % CO ν , the DES-based HFMC separated CO 2 with a purity of 96.9 mol %. The effect of several process parameters including solvent flow rate, pressure, and temperature on the CO 2 separation performance was studied. The flux of the recovered CO 2 was 67.43 mmole/m 2 /h at a feed pressure of 4 bar. In situ Fourier transform infrared (FTIR) measurements combined with density functional theory (DFT)-based molecular dynamics simulations revealed that reline absorbs CO 2 by physical absorption without forming a new chemical compound, and CO 2 separation by reline occurs via the pressure swing mechanism. This research provides fundamental insights about physical solvent-based separation processes and a pathway toward practical deployment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Economics of CCUS

High level overview of the performance and cost of post-combustion CO2 capture on pulverized coal and natural gas combined cycles in greenfield and retrofit applications. Includes effects of less than 90% capture as well.

Fout, Timothy↗

TEA of a Unique Two-Pathways Process for Post-Combustion CO 2 Capture

A unique two-Pathways process using aqueous sodium glycinate for CO 2 capture from a split flue gas stream emitted from 600 MWe post-combustion coal power plant was developed in Aspen Plus v.10. The split gas flow rate used was 44.75 ton/h and contained 0.0023 mol% SO 2 and 13.33 mol% CO 2 . The process includes a washing unit, a CO 2 absorption unit, a reverse osmosis unit, and a solvent regeneration unit or an ultrafiltration unit. The washing unit uses deionized water to completely remove SO 2 and the CO 2 absorption unit uses SGS to capture at least 90 mol% of the CO 2 in the split flue gas stream. Upon CO 2 and SGS reactions, the resulting liquid products exhibit phase-separation into CO 2 -lean phase and CO 2 -rich phase, allow two distinct pathways. Pathway (i) is to regenerate mostly the CO 2 -rich phase, collect the released CO 2 , and compress it for sequestration purposes. Pathway (ii) is to send the liquid stream from the CO 2 absorption unit to the ultrafiltration unit to separate the solid nanomaterials. The hydraulics and mass transfer characteristics in the washing and CO 2 absorption units were obtained; and techno-economic analysis (TEA) for Pathways (i) and (ii), including Capital Expenditure (CAPEX), Operating Expenditure (OPEX), and Levelized Cost of CO 2 Captured (LCOC), were calculated and compared. The simulation results revealed that the CAPEX, OPEX, and LCOC for Pathway (i) were ($\$12,039,251$), (261 dollar/h), and (54.01 dollar/ton-CO 2 captured), respectively, and those for Pathway (ii) were ($\$5,908,000$), (237.2 dollar/h), and (39.90 dollar/ton-CO 2 captured), respectively. Moreover, in Pathway (ii), 8.19 ton/h of CO 2 were captured to produce 15.62 ton/h NaHCO 3 nanomaterials, which were sold to offset the overall process cost. The LCOC values indicate that Pathway (ii) is more cost-effective than Pathway (i) because LCOC values for Pathway (ii) are much lower than those for Pathway (i).COC values for Pathway (ii) are much lower than those for Pathway (i).

20 FOSSIL-FUELED POWER PLANTS↗

A Process with Decoupled Absorber Kinetics and Solvent Regeneration through Membrane Dewatering and In-Column Heat Transfer (Final Report)

This report summarizes the work conducted on project DE-FE0031604 where University of Kentucky Center for Applied Energy (UK CAER) has validated its intensified CO 2 capture process through substantial enhancements to the kinetics of the absorption process and energy reductions by absorber temperature profile modification, dewatering and heat integration technologies for achieving significant capital and operating cost reductions. To address DOE’s objective of improving post-combustion CO 2 capture technology and reducing associated cost, UK CAER employed an intensified process which combined three key aspects targeted at overcoming inherent limitations or barriers in the conventional CO 2 capture and desorption process. The process designed to be independent of the type of solvent used, included (1) the use of 3-D printed two-channel structured packing material to control the temperature profile and increase the CO 2 absorption rate in the absorber, (2) a zeolite membrane dewatering unit for dewatering of the carbon-rich solvent to decouple solvent concentration needs for CO 2 absorption and desorption, and (3) a rich-split feed with two-phase flow heat transfer prior to the stripper that provided a secondary point of vapor generation to provide energy savings in steam extraction and solvent regeneration. The project was executed over two budget periods. This involved testing of individual process components which included the advanced heat transfer packing and the dewatering membrane on UK CAER’s 30 liter per minute (L/min) CO 2 (3” Column) capture bench unit with simulated flue gas in the first budget period. Subsequent scaled-up testing of these components together with the split-feed configuration were also tested in UK CAER’s 0.1 MWth CO 2 capture unit with coal-derived flue gas in the second-budget period. Long term studies were done during this period to assess process and solvent performance over extended duration. Project partners Lawrence Livermore National Laboratory (LLNL) and Media & Process Technology (MPT) led the development efforts for the advanced packing material and dewatering membrane respectively. Data from the long term testing was used as input for an environmental, health and safety (EH&S) assessment for the process and scaled technology performed by ALL4 LLC. Trimeric Corporation also completed a techno-economic analysis (TEA) for the UK CAER technology which was compared to the DOE reference Case B12B. Tests on the 3” column capture unit showed that the advanced heat transfer packing could be used to lower the bulge temperature in the absorber, and this was also proven in the scaled testing in the 0.1 MWth CO 2 capture unit. The bulge temperature could be lowered by >10 °C, changing the temperature profile in the absorber, and showed potential to enhance absorption with the ability to tailor the profile to provide conditions suitable for a solvent’s properties and kinetics. Conditions for short term evaluation of a 19” zeolite dewatering membrane on the 3” column capture unit yielded desirable fluxes and sustained rejection rates of >80%. However, for the scaled testing of six membrane modules consisting of 21 parts of 31-inch-long membrane tubes in each bundle (surface area 0.3 m 2 ), over a more extended duration, similar rejection rates could not be achieved. With the split-feed of the rich stream to the stripper, improved heat recovery minimized waste heat exiting the top of the stripper. The stripper exhaust temperatures could be reduced by >10 °C; reducing the amount of water vaporization contributed to lowering the regeneration energy by ~ 15%. The energy benefit could be sustained from the long term monitoring of the solvent performance. The solvent properties were not significantly impacted over the long-term operations. The benefits of the UK CAER process demonstrated experimentally were mostly validated from the TEA comparing a commercial scale application of the technology to DOE reference Case B12B. The cost of CO 2 capture for the UK CAER technology was estimated to be ~$34.97/tonne of CO 2 captured; a reduction of 23% compared to Case B12B. The increase in cost of electricity was also shown to be 16% lower than that of Case B12B. The total parasitic demand was also shown to be 11% lower. The key drivers for the benefits are a result of the process intensification approaches employed in the UK CAER technology for enhanced solvent performance, effective heat recovery and improved energy performance. The EH&S assessment did not find any major environmental concerns or barriers to the full scale implementation of the technology.

20 FOSSIL-FUELED POWER PLANTS↗

Advances in systems metabolic engineering of autotrophic carbon oxide-fixing biocatalysts towards a circular economy

High levels of anthropogenic CO 2 emissions are driving the warming of global climate. If this pattern of increasing emissions does not change, it will cause further climate change with severe consequences for the human population. On top of this, the increasing accumulation of solid waste within the linear economy model is threatening global biosustainability. The magnitude of these challenges requires several approaches to capture and utilize waste carbon and establish a circular economy. Microbial gas fermentation presents an exciting opportunity to capture carbon oxides from gaseous and solid waste streams with high feedstock flexibility and selectivity. Here we discuss available microbial systems and review in detail the metabolism of both anaerobic acetogens and aerobic hydrogenotrophs and their ability to utilize C1 waste feedstocks. More specifically, we provide an overview of the systems-level understanding of metabolism, key metabolic pathways, scale-up opportunities and commercial successes, and the most recent technological advances in strain and process engineering. Finally, we also discuss in detail the gaps and opportunities to advance the understanding of these autotrophic biocatalysts for the efficient and economically viable production of bioproducts from recycled carbon.

59 BASIC BIOLOGICAL SCIENCES↗

DECOVALEX-2023: Task A Final Report

Task A, also known as HGFrac, examines the fracturing processes that may occur in the Callovo-Oxfordian claystone (COx) in the context of the high-level (HLW) and intermediate-level long-lived (ILW-LL) radioactive waste repository in France. Understanding these processes and improving numerical models to reproduce them will aid in the design, optimization, and safety of the repository. Heat and gas fracturing are studied in two independent subtasks following a stepwise approach: laboratory tests/benchmark exercises, in-situ experiment, and finally, an application case. The in-situ heater experiment aimed to thermally induce a hydraulic fracture; temperature and pore pressure were monitored to detect any evidence of fracturing. The in-situ gas injection experiment aimed to study the effect of the stress orientation and gas injection kinetics on the gas fracturing process. The occurrence of fracturing was monitored by gas pressure measured in the injection interval. In both experiments, the excavation-induced fracture network around the heater/injection boreholes played an important role in the reduction of the compressive stress state, leading to both a tensile and shear failure response of the COx. During the first two years of the project, the research teams working on each task developed and/or proposed numerical approaches for reproducing the occurrence of fracturing in the in-situ experiments. The failure criteria were defined by reproducing the measurements from laboratory extension tests for the heat fracturing subtask. In the gas fracturing subtask, their approaches were used for simulating several benchmark exercises, and an inter-comparison between models was carried out. In both tasks, the developed approaches were compared with a simplified approach considering poro-elasticity for the mechanical behaviour of the COx. Most of the developed approaches are based on a continuous medium that takes into account variations in hydraulic properties due to mechanical degradation, such as plastic deformation or damage. Other approaches implicitly modelled weak planes or embedded discontinuities to reproduce fracture propagation. The potential for fracture initiation was also studied through of a discrete approach. In the second half of the project, the research teams mainly focused on interpretative modelling of two in-situ experiments and a blind prediction exercise to test their respective approaches. The models developed by the research teams were also applied at the repository scale to evaluate fracture initiation in a case study under vi unfavourable conditions, particularly in terms of spacing between High-Level Waste cells. The results showed that the poro-elasticity approach could be an efficient tool for understanding the main processes occurring in the COx. One example is the explicit representation of the excavation-induced fracture network around the boreholes, which yielded acceptable results compared to the measurement data. However, advanced approaches were needed to evaluate the potential increase of the excavation-induced fracture network extend and better understand fracture initiation. The stress analyses carried out by the teams revealed that hydraulic boundary conditions had a strong impact on fracture initiation in the heater experiment. Furthermore, in most cases, the results required higher pore pressure increments to reach fracturing than those measured in the experiment. This implies that the measurements may have been biased by the packer’s capacity to fully isolate the piezometric chambers, leading to lower pressures. On the contrary, there was no agreement on the fracturing mode, as some reported either shear or tensile fracturing, while others reported a combination of the two modes. In the case of gas fracturing, the research teams were limited to the comparison of a single point, which complicated their task. Nonetheless, the numerical results were able to reproduce the measurements and capture processes such as longitudinal gas flow through the excavation-induced fracture network, as suggested by some evidence in the observation piezometric chambers. The numerical models also agreed with the measurements in the sense of higher probability of developing along the injection borehole than radially towards the sound rock. The approaches developed by the research teams showed that they are capable of analysing and reproducing fracture initiation in the COx. However, areas of future work should focus on the fracture propagation and fracture aperture, which were out of the scope of this task. To this end, additional data must be gathered for the parameter characterisation and validation of the numerical models. Nonetheless, various approaches showed promising results as they were able to reproduce fracture development under certain conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Molecular-Level Overhaul of y-Aminopropyl Aminosilicone/Triethylene Glycol Post-Combustion CO2-Capture Solvents

Capturing carbon dioxide (CO2) from post-combustion gas streams is an energy-intensive process that is required prior to either converting or sequestering CO2. There are a few commercial offerings of 1st and 2nd generation aqueous amine technologies, however the cost of capturing CO2 with these technologies remains high. To decrease costs of capture, researchers are designing efficient solvent systems with the goal of being drop-in replacements for 1st and 2nd generation infrastructure. One approach has seen the development of water-lean solvents that aim to increase efficiency by reducing the water content in solution. Water-lean solvents such as GE’s GAP/TEG are promising technologies, with potential to halve the parasitic load to a coal-fired power plant, only if the intrinsically high solution viscosities and hydrolysis of the siloxane moieties could be mitigated. We present here, an integrated multidisciplinary approach to overhaul the GAP/TEG solvent system at the molecular level to mitigate hydrolysis while also reducing viscosity. We present molecular-level insights into chemical speciation of CO2-containing ions, showing that co-solvents and diluents have a negligible effect on reducing viscosity and are not needed. This finding allowed for the design of singlecomponent siloxane-free diamine derivatives with site-specific incorporation of selective chemical moieties for direct placement and orientation of hydrogen bonding to reduce viscosity. Ultimately, we present new single-component diamine formulations less susceptible to hydrolysis that exhibit up to a 98% reduction in viscosity compared to the initial GAP/TEG formulation.

Cantu Cantu, David↗