Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “functional performance testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Meshless Local Petrov-Galerkin (MLPG) Method with Orthogonal Polynomials for Euler-Bernoulli Beam Problems

In this paper, the feasibility of orthogonal polynomials in the meshless local Petrov Galerkin method (MLPG) method is studied. The orthogonal polynomials, Chebyshev and Legendre polynomials, are used in this MLPG method as trial functions. The test functions used were power functions with smooth derivatives at their ends. The performance of these methods is studied by applying these methods to Euler-Bernoulli beam problems. The MLPG-Galerkin and Legendre methods passed all the patch tests for simple beam problems. Next the formulations are tested on complex beam problems such as beams with partial loadings and continuous beam problems. Problems with load discontinuities and additional supports require special attention. Near discontinuities, judicious choice of number of nodes and nodal placements are needed to obtain accurate deflections, slopes, moments and shear forces. As polynomial functions are used, the large number of nodes can create a transformation matrix that is ill-conditioned, resulting in problems with the inversion of the matrix. The conditioning worsens as the number of nodes are increased beyond 20. Quadruple precision was needed for models to obtain accurate solutions. Even with quadruple precision the accuracy of the method suffers as the number of nodes is increased beyond 20. This appears to be a drawback of the MLPG-Chebyshev and MLPG-Legendre methods.

Raju, Ivatury S.↗

DVA as a Diagnostic Test for Vestibulo-Ocular Reflex Function

The vestibulo-ocular reflex (VOR) stabilizes vision on earth-fixed targets by eliciting eyes movements in response to changes in head position. How well the eyes perform this task can be functionally measured by the dynamic visual acuity (DVA) test. We designed a passive, horizontal DVA test to specifically study the acuity and reaction time when looking in different target locations. Visual acuity was compared among 12 subjects using a standard Landolt C wall chart, a computerized static (no rotation) acuity test and dynamic acuity test while oscillating at 0.8 Hz (+/-60 deg/s). In addition, five trials with yaw oscillation randomly presented a visual target in one of nine different locations with the size and presentation duration of the visual target varying across trials. The results showed a significant difference between the static and dynamic threshold acuities as well as a significant difference between the visual targets presented in the horizontal plane versus those in the vertical plane when comparing accuracy of vision and reaction time of the response. Visual acuity increased proportional to the size of the visual target and increased between 150 and 300 msec duration. We conclude that dynamic visual acuity varies with target location, with acuity optimized for targets in the plane of rotation. This DVA test could be used as a functional diagnostic test for visual-vestibular and neuro-cognitive impairments by assessing both accuracy and reaction time to acquire visual targets.

Wood, Scott J.↗

Digital 8-DPSK Modem For Trellis-Coded Communication

Digital real-time modem processes octuple differential-phase-shift-keyed trellis-coded modulation. Intended for use in communicating data at rate up to 4.8 kb/s in land-mobile satellite channel (Rician fading) of 5-kHz bandwidth at carrier frequency of 1 to 2 GHz. Modulator and demodulator contain digital signal processors performing modem functions. Design flexible in that functions altered via software. Modem successfully tested and evaluated in both laboratory and field experiments, including recent full-scale satellite experiment. In all cases, modem performed within 1 dB of theory. Other communication systems benefitting from this type of modem include land mobile (without satellites), paging, digitized voice, and frequency-modulation subcarrier data broadcasting.

Jedrey, T. C.↗

An Independent Orbit Determination Simulation for the OSIRIS-REx Asteroid Sample Return Mission

After arriving at the near-Earth asteroid (101955) Bennu in late 2018, the OSIRIS-REx spacecraft will execute a series of observation campaigns and orbit phases to accurately characterize Bennu and ultimately collect a sample of pristine regolith from its surface. While in the vicinity of Bennu, the OSIRIS-REx navigation team will rely on a combination of ground-based radiometric tracking data and optical navigation (OpNav) images to generate and deliver precision orbit determination products. Long before arrival at Bennu, the navigation team is performing multiple orbit determination simulations and thread tests to verify navigation performance and ensure interfaces between multiple software suites function properly. In this paper, we will summarize the results of an independent orbit determination simulation of the Orbit B phase of the mission performed to test the interface between the OpNav image processing and orbit determination software packages.

Orbit↗

EOS-AM1 Nickel Hydrogen Cell Interim Life Test Report

This paper reports the interim results of the Earth Observing System AM-1 project (EOS-AM-1) nickel hydrogen cell life test being conducted under contract to National Aeronautics and Space Administration (NASA) Goddard Space Flight Center (GSFC) at the Lockheed Martin Missiles and Space (LMMS) facility in East Windsor, NJ; and at COMSAT Labs., Clarksburg, MD. The purpose of the tests is to verify that the EOS-AM-l cell design can meet five years of real-time Low Earth Orbit (LEO) cycling. The tests include both real-time LEO and accelerated stress tests. At LMMS, the first real-time LEO simulated 99 minute orbital cycle started on February 7, 1994 and the test has been running continuously since that time, with 13000 LEO cycles completed as of September 2, 1996. Each cycle consists of a 64 minute charge (VT at 1.507 volts per cell, 1.06 C/D ratio, followed by 0.6 ampere trickle charge) and a 35 minute constant power discharge at 177 watts (22.5% DOD). At COMSAT, the accelerated stress test consists of 90 minute orbital cycles at 60% DOD with a 30 minute discharge at 60 amperes and a 60 minute charge at 40 ampercs (VT at 1.54 volts per cell to 1.09 C/D ratio, followed by 0.6 ampere trickle charge). The real-time LEO life test battery consists of seven, 50AH (nameplate rating) Eagle-Picher, Inc. (EPI) Mantech cells manufactured into three, 3-cell pack assemblies (there are two place holder cells that are not part of the life test electrical circuit). The test pack is configured to simulate the conductive thermal design of the spacecraft battely, including: conductive aluminum sleeves, 3-cell pack aluminum baseplate, and honeycomb panel all mounted to a liquid (-5 C) cold plate. The entire assembly is located in a thermal chamber operating at +3 C. The accelerated stress test unit consists of five cells mounted in machined aluminum test sleeves and is operating at +10 C. The real-time LEO life test battery has met all performance requirements through the first 13,000 cycles, including: end of charge and discharge cell voltages and voltage gradients; end of chalge and discharge cell pressures; within cell and between cell temperature gradients; discharge capacity; current and power levels; and all chalge parameters. The accelerated stress test battely has completed over 5900 cycles as of 9/11/96. This paper reports both battery performances as a function of cycle life, with individual cell performance comparisons repolted for selected cycles in both tests.

Bennett, C. W.↗

A full-scale wind tunnel investigation of a helicopter bearingless main rotor

A helicopter bearingless main rotor was tested. Areas of investigation included aeroelastic stability, aerodynamic performance, and rotor loads as a function of collective pitch setting, RPM, airspeed and shaft angle. The rotor/support system was tested with the wind tunnel balance dampers installed and, subsequently, removed. Modifications to the rotor hub were tested. These included a reduction in the rotor control system stiffness and increased flexbeam structural damping. The primary objective of the test was to determine aeroelastic stability of the fundamental flexbeam/blade chordwise bending mode. The rotor was stable for all conditions. Damping of the rotor chordwise bending mode increases with increased collective pitch angle at constant operating conditions. No significant decrease in rotor damping occured due to frequency coalescence between the blade chordwise fundamental bending mode and the support system.

Warmbrodt, W.↗

The Effect of Transfer Line Length and Heat Rejection Temperature Distribution on the Thales Linear Pulse Tube (LPT) Cryocoolers

Four Thales LPT9310 and four Thales LPT9510 commercial off-the-shelf (COTS) cryocoolers were parametrically performance tested. The LPT9310 coolers had transfer lines of various lengths while the LPT9510 coolers all had the same transfer line geometry. The LPT9510 test results revealed unit-tounit thermodynamic performance variation, quantified the effect of compressor temperature on thermodynamic performance and quantified the heat flow distribution between the compressor and expander as a function of their temperature distribution. The LPT9310 test results revealed the optimal drive frequency as a function of transfer line length, quantified the effect of heat rejection temperature distribution on thermodynamic performance and enabled the development and verification of a thermodynamic performance prediction tool that accounted for cold tip temperature, heat lift, heat rejection temperature and transfer line length.

Rodriguez, J.I.↗

Phenomena associated with bench and thermal-vacuum testing of super conductors - Heat pipes.

Test failures of heat pipes occur when the functional performance is unable to match the expected design limits or when the power applied to the heat pipe (in the form of heat) is distributed unevenly through the system, yielding a large thermal gradient. When a thermal gradient larger than expected is measured, it normally occurs in the evaporator or condenser sections of the pipe. Common causes include evaporator overheating, condenser dropout, noncondensable gas formation, surge and partial recovery of evaporator temperatures, masking of thermal profiles, and simple malfunctions due to leaks and mechanical failures or flaws. Examples of each of these phenomena are described along with corresponding failure analyses and corrective measures.

Marshburn, J. P.↗

In-flight measured human pilot describing function and remnant for pitch attitude control

Flight tests have been performed with a variable pitch-rate-command/attitude-hold flight control system in a Beechoraft Queen air-80 aircraft. Some results of in-flight measured runs for two pilots controlling typical easy and difficult dynamics are presented together with the initial results of the same tracking experiment performed on a ground-based flight simulator. Results are compared with results of other investigators using fixed-base flight simulators.

Mooij, H. A.↗

Parametric performance of circumferentially grooved heat pipes with homogeneous and graded-porosity slab wicks at cryogenic temperatures

A recently developed, potentially high-performance nonarterial wick has been extensively tested. This slab wick has an axially varying porosity which can be tailored to match the local stress imposed on the wick. The purpose of the tests was to establish the usefulness of the graded-porosity slab wick at cryogenic temperatures between 110 K and 260 K, with methane and ethane as working fluids. For comparison, a homogeneous (i.e., uniform porosity) slab wick was also tested. The tests included: (1) maximum heat pipe performance as a function of fluid inventory, (2) maximum performance as a function of operating temperature, (3) maximum performance as a function of evaporator elevation, and (4) influence of slab wick orientation on performance. The experimental data was compared with theoretical predictions obtained with the computer program GRADE.

Groll, M.↗

Prediction and verification of creep behavior in metallic materials and components for the space shuttle thermal protection system

A method of analysis was developed for predicting permanent cyclic creep deflections in stiffened panel structures. This method uses creep equations based on cyclic tensile creep tests and a computer program to predict panel deflections as a function of mission cycle. Four materials were investigated - a titanium alloy (Ti-6Al-4V), a cobalt alloy (L605), and two nickel alloys (Rene'41 and TDNiCr). Steady-state and cyclic creep response data were obtained by testing tensile specimens fabricated from thin gage sheet (0.025 and 0.63 cm nominal). Steady-state and cyclic creep equations were developed which describe creep as a function of time, temperature and load. Tests were also performed on subsize (6.35 x 30.5 cm) rib and corrugation stiffened panels. These tests were used to correlate creep responses between elemental specimens and panels. The panel response was analyzed by use of a specially written computer program.

Davis, J. W.↗

Estimating crop proportions from remotely sensed data

The classification/pixel-count method for estimating the proportion of wheat in each segment is theoretically biased even if all distributional assumptions are met. Alternative ways to estimate crop proportions are examined and their performance testing is considered. Topics covered include general linear functional estimates, the method of moments, and maximum likelihood estimators.

Feiveson, A. H.↗

Visual-Accommodation Trainer/Tester

Ophthalmic instrument tests and helps develop focusing ability. Movable stage on a fixed base permits adjustment of effective target position as perceived by subject. Various apertures used to perform tests and training procedures. Ophthalmic instrument provides four functions: it measures visual near and far points; provides focus stimulus in vision research; measures visual-accommodation resting position; can be used to train for volitional control of person's focus response.

Randle, Robert J., Jr.↗

Integrated heat pipe-thermal storage system performance evaluation

An integrated thermal energy storage (TES) system, developed as a part of an organic Rankine cycle solar dynamic power system is described, and the results of the performance verification tests of this TES system are presented. The integrated system consists of potassium heat-pipe elements that incorporate TES canisters within the vapor space, along with an organic fluid heater tube used as the condenser region of the heat pipe. The heat pipe assembly was operated through the range of design conditions from the nominal design input of 4.8 kW to a maximum of 5.7 kW. The performance verification tests show that the system meets the functional requirements of absorbing the solar energy reflected by the concentrator, transporting the energy to the organic Rankine heater, providing thermal storage for the eclipse phase, and allowing uniform discharge from the thermal storage to the heater.

Keddy, E.↗

Smart command recognizer (SCR) - For development, test, and implementation of speech commands

The SCR, a rapid prototyping system for the development, testing, and implementation of speech commands in a flight simulator or test aircraft, is described. A single unit performs all functions needed during these three phases of system development, while the use of common software and speech command data structure files greatly reduces the preparation time for successive development phases. As a smart peripheral to a simulation or flight host computer, the SCR interprets the pilot's spoken input and passes command codes to the simulation or flight computer.

Simpson, Carol A.↗

Cardiovascular response to lower body negative pressure stimulation before, during, and after space flight

BACKGROUND: It is well known that space travel cause post-flight orthostatic hypotension and it was assumed that autonomic cardiovascular control deteriorates in space. Lower body negative pressure (LBNP) was used to assess autonomic function of the cardiovascular system. METHODS: LBNP tests were performed on six crew-members before and on the first days post-flight in a series of three space missions. Additionally, two of the subjects performed LBNP tests in-flight. LBNP mimics fluid distribution of upright posture in a gravity independent way. It causes an artificial sequestration of blood, reduces preload, and filtrates plasma into the lower part of the body. Fluid distribution was assessed by bioelectrical impedance and anthropometric measurements. RESULTS: Heart rate, blood pressure, and total peripheral resistance increased significantly during LBNP experiments in-flight. The decrease in stroke volume, the increased pooling of blood, and the increased filtration of plasma into the lower limbs during LBNP indicated that a plasma volume reduction and a deficit of the interstitial volume of lower limbs rather than a change in cardiovascular control was responsible for the in-flight response. Post-flight LBNP showed no signs of cardiovascular deterioration. The still more pronounced haemodynamic changes during LBNP reflected the expected behaviour of cardiovascular control faced with less intravascular volume. In-flight, the status of an intra-and extravascular fluid deficit increases sympathetic activity, the release of vasoactive substances and consequently blood pressure. Post-flight, blood pressure decreases significantly below pre-flight values after restoration of volume deficits. CONCLUSION: We conclude that the cardiovascular changes in-flight are a consequence of a fluid deficit rather than a consequence of changes in autonomic signal processing.

manned↗