Nickel-Graphite Composite Compliant Interface and/or Hot Shoe Material

Next-generation high-temperature thermoelectric-power-generating devices will employ segmented architectures and will have to reliably withstand thermally induced mechanical stresses produced during component fabrication, device assembly, and operation. Thermoelectric materials have typically poor mechanical strength, exhibit brittle behavior, and possess a wide range of coefficient of thermal expansion (CTE) values. As a result, the direct bonding at elevated temperatures of these materials to each other to produce segmented leg components is difficult, and often results in localized microcracking at interfaces and mec hanical failure due to the stresses that arise from the CTE mismatch between the various materials. Even in the absence of full mechanical failure, degraded interfaces can lead to increased electrical and thermal resistances, which adversely impact conversion efficiency and power output. The proposed solution is the insertion of a mechanically compliant layer, with high electrical and thermal conductivity, between the low- and high-temperature segments to relieve thermomechanical stresses during device fabrication and operation. This composite material can be used as a stress-relieving layer between the thermoelectric segments and/or between a thermoelectric segment and a hot- or cold-side interconnect material. The material also can be used as a compliant hot shoe. Nickel-coated graphite powders were hot-pressed to form a nickel-graphite composite material. A freestanding thermoelectric segmented leg was fabricated by brazing the compliant pad layer between the high-temperature p- Zintl and low-temperature p-SKD TE segments using Cu-Ag braze foils. The segmented leg stack was heated in vacuum under a compressive load to achieve bonding. The novelty of the innovation is the use of composite material that re duces the thermomechanical stresses en - countered in the construction of high-efficiency, high-temperature therm - o-electric devices. The compliant pad enables the bonding of dissimilar thermoelectric materials while maintaining the desired electrical and thermal properties essential for efficient device operation. The modulus, CTE, electrical, and thermal conductances of the composite can be controlled by varying the ratio of nickel to graphite.

Firdosy, Samad A.↗

Multilayer Dielectric Transmissive Optical Phase Modulator

A multilayer dielectric device has been fabricated as a prototype of a low-loss, low-distortion, transmissive optical phase modulator that would provide as much as a full cycle of phase change for all frequency components of a transmitted optical pulse over a frequency band as wide as 6.3 THz. Arrays of devices like this one could be an alternative to the arrays of mechanically actuated phase-control optics (adaptive optics) that have heretofore been used to correct for wave-front distortions in highly precise optical systems. Potential applications for these high-speed wave-front-control arrays of devices include agile beam steering, optical communications, optical metrology, optical tracking and targeting, directional optical ranging, and interferometric astronomy. The device concept is based on the same principle as that of band-pass interference filters made of multiple dielectric layers with fractional-wavelength thicknesses, except that here there is an additional focus on obtaining the desired spectral phase profile in addition to the device s spectral transmission profile. The device includes a GaAs substrate, on which there is deposited a stack of GaAs layers alternating with AlAs layers, amounting to a total of 91 layers. The design thicknesses of the layers range from 10 nm to greater than 1 micrometer. The number of layers and the thickness of each layer were chosen in a computational optimization process in which the wavelength dependences of the indices of refraction of GaAs and AlAs were taken into account as the design was iterated to maximize the transmission and minimize the group-velocity dispersion for a wavelength band wide enough to include all significant spectral components of the pulsed optical signal to be phase modulated.

Keys, Andrew Scott↗

Thermo-economic analysis of a solid oxide fuel cell-gas turbine hybrid with commercial off-the-shelf gas turbine

The thermodynamic and economic performance of a natural gas-fueled solid oxide fuel cell (SOFC)-gas turbine (GT) hybrid system with a commercial off-the-shelf GT is investigated. Until today, commercial GTs are primarily engineered for the direct use of energy dense fuels, such as natural gas, and the integration of commercial GTs into a SOFC-GT hybrid remains challenging. In this work technically feasible and economically viable GT operating modes are identified to gauge the technology’s competitiveness on the free market. Steady state, full load operating conditions were established for various GT operating modes: I) constant spool speed operation, II) variable spool speed operation and III) partially closed compressor inlet guide vanes. For each GT operating mode, the performance was investigated over a range of SOFC fuel utilization factors, while considering physical constraints inside the SOFC, such as local temperature gradients in flow direction as well as overall cell temperature differences. The results of the thermodynamic evaluation served as inputs for the economic analysis of the SOFC-GT hybrid power plant. The results show that the integration of an off-the-shelf GT not only results in a significant derating of the GT, but also substantially impacts the SOFC operation, the main power producer in this SOFC-GT hybrid. To maximize the SOFC power output it is desirable operate the GT in a region of high air mass flow rates and low pressure ratios, which increases the number of stacks that can be accommodated and reduces the SOFC cooling requirement. The lowest costs of electricity are obtained at constant spool speed operation, while the highest efficiencies are reached at variable spool speed operation. Critical for the integration of off-the-shelf GTs, which historically have been designed for natural gas, is the surge margin. The largest surge margins are obtained by closing the compressor inlet guide vanes. Furthermore, higher SOFC fuel utilization factors are shown to increase the surge margin as the turbine firing temperature is decreased.

25 ENERGY STORAGE↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Marine Hydrokinetic Tidal Turbine

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset is part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with other energy technologies. This dataset contains inputs and outputs from simulations of a floating marine hydrokinetic turbine over approximately half a tidal cycle (~6.6 hours). Inflow conditions were derived from field measurements in Alaska’s Cook Inlet and represent a tidal environment in which the current speed ramps from near 0 m/s to a peak of 3 m/s and back. The original acoustic doppler current profiler dataset is publicly available on the Marine and Hydrokinetic Data Repository. In a full tidal cycle, the flow reverses and the rotor would reorient; this reversal was not modeled. In the Cook Inlet campaign , turbulence intensity was similar in both directions. Two inflow cases are included. In the first case, labeled “raw” in the files, the measured current time series was used directly in the InflowWind module of OpenFAST. Speed and direction were applied as a function of time and elevation, uniformly in the horizontal direction. With full spatial coherence, this approach captures high turbulent variability and results in pronounced power fluctuations, so it is considered a conservative, near-worst-case representation of loading. In the second case, labeled “average” in the files, a 30-minute moving average was applied to extract the slowly varying mean speed. The residual fluctuations about this mean were used to generate spatially varying, full-field turbulence inputs with TurbSim, giving a more physically realistic representation of the inflow across the rotor disk. Two random realizations were used to produce distinct inflow conditions for two OpenFAST simulations representing a two-turbine array. The same turbulence intensity is applied across the full time series, producing larger fluctuations at the start and end, where the mean speed is low. The second case is the more appropriate framework for performance and power assessment but overpredicts turbulence at lower flow speeds and underpredicts it at higher speeds. As the floating platform moves and the rotor changes its x-position, Taylor’s frozen turbulence hypothesis used by InflowWind assumes a constant rather than a time-varying mean velocity, introducing some inaccuracy in the velocity plane sampling. The turbine modeled is the 500-kW Reference Model 1, a horizontal-axis two-bladed hydrokinetic turbine on a four-column floating semisubmersible substructure . Simulations were performed using OpenFAST v4.1 with the Reference Open Source Controller (ROSCO) v2.10. All input files required to reproduce the simulations are included. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel . This unit supports up to 2.5 MW, but NLR has only a single 1.25-MW stack. The datasets report hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. The system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operating current of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The simulated tidal turbine time series data was translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz. Each zip file represents a single tidal electrolysis experiment and is named: {technology}_{inflow method}_{number of 500 kW tidal turbines connected} For instance, “tidal-500kW-RM1_average_2.zip” is a 6-hour experiment using the 500-kW tidal reference model, scaled by 2x (1-MW) to better match the electrolyzer maximum of 1.25MW, fed with the 30-minute moving average current case. Each zip folder contains the following files: A .csv file of raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. A .csv file combines all tidal profiles as "combined_tidal_experiments.csv." A separate experiment, “characterization_200.zip,” shows the MC250 electrolyzer steady-state response with 30-minute load steps over 5 hours and is accessible with this entry.

08 HYDROGEN↗

A CFD Analysis of Hydrogen Leakage During On-Pad Purge in the ORION/ARES I Shared Volume

A common open volume is created by the stacking of the Orion vehicle onto the Ares I Upper Stage. Called the Shared Volume, both vehicles contribute to its gas, fluid, and thermal environment. One of these environments is related to hazardous hydrogen gas. While both vehicles use inert purge gas to mitigate any hazardous gas buildup, there are concerns that hydrogen gas may still accumulate and that the Ares I Hazardous Gas Detection System will not be sufficient for monitoring the integrated volume. This Computational Fluid Dynamics (CFD) analysis has been performed to examine these topics. Results of the analysis conclude that the Ares I Hazardous Gas Detection System will be able to sample the vent effluent containing the highest hydrogen concentrations. A second conclusion is that hydrogen does not accumulate under the Orion Service Module (SM) avionics ring as diffusion and purge flow mixing sufficiently dilute the hydrogen to safe concentrations. Finally the hydrogen concentrations within the Orion SM engine nozzle may slightly exceed the 1 percent volume fraction when the entire worse case maximum full leak is directed vertically into the engine nozzle.

Ajmani, Kumud↗

High temporal frequency data from a four turbine, blade-resolved wind farm simulation with ExaWind

The data was generated with ExaWind (https://github.com/Exawind) which couples AMR-Wind (https://github.com/Exawind/amr-wind/), Nalu-Wind (https://github.com/Exawind/nalu-wind), TIOGA (https://github.com/Exawind/tioga), and OpenFAST (https://github.com/OpenFAST/openfast). This is a large-scale simulation of a blade-resolved wind farm using the ExaWind software stack. ExaWind couples together a background flow solver, AMR-Wind, and a near-body solver, Nalu-Wind, through an overset technique from the TIOGA application. Another application, OpenFAST, handles the structural dynamics of the turbine blades and towers, which informs the fluid-structure interaction of the wind turbines with the flow solvers. This particular simulation includes four blade-resolved wind turbines operating in a turbulent atmospheric boundary layer. The AMR-Wind solver uses 500 million cells and is being solved on 256 AMD GPUs of the Oakridge Leadership Computing Facility Frontier supercomputer. Each turbine is assigned its own Nalu-Wind solver with over 13 million elements per turbine and solved using 448 CPU cores, for a total of 1792 CPU cores. For each node, 56 cores contain Nalu-Wind, while 8 cores correspond to AMR-Wind operations on the GPUs. Consequently, ExaWind is entirely utilizing the CPUs and the GPUs of the nodes concurrently. The data used in the visualization is full flow field data output from the simulation. It is lossy-compressed to a specific accuracy using ZFP and written to disk every 16 time-steps to enable real-time flow visualization. The flow fields are sampled at a high temporal frequency to enable real-time, 24fps visualization. The flow fields are sampled every 12 simulation time steps (every 0.04132s).

17 WIND ENERGY↗

H I Depletion Begins Well Beyond the Virial Radius: A FAST Stacking Study of 36 Galaxy Clusters to 5 × R 200

Abstract We present a stacking study of the neutral atomic hydrogen (H i ) content in and around 36 local galaxy clusters at z < 0.07, using a combination of the FAST All Sky H i survey (FASHI) and the extensive spectroscopic catalog mainly from the Dark Energy Spectroscopic Instrument (DESI). We employ spectral stacking techniques to probe the average H i mass and HI-to-stellar mass ratio ( M HI / M * ) for member galaxies down to stellar masses of M * ∼ 10 9 M ⊙ , spanning a projected cluster-centric distance of up to 5 R 200 . Our analysis reveals a pronounced environmental effect; both M HI and M HI / M * decrease steadily toward the cluster center, dropping by ∼0.5 dex on average from the outskirts to the core. Crucially, we find that M HI / M * of galaxies remain lower than the field galaxies even at the 5 R 200 . This provides direct, statistical evidence for substantial gas stripping and preprocessing in the cluster outskirts, likely occurring in infalling groups and large-scale filaments. By further splitting the sample by g − r color, we show that the H i deficiency persists at fixed galaxy color; even the bluest cluster members exhibit ∼0.5 dex lower M HI / M * than field galaxies of similar color, reflecting environmental effects on the cold gas reservoir prior to full optical transformation. The total H i mass within clusters and their outskirts agrees broadly with predictions from cosmological simulations. Our results underscore the critical role of the extended cluster environment in quenching galaxies by depleting their cold gas reservoirs well before they enter the dense cluster core.

Cheng, Cheng [Chinese Academy of Sciences South Am↗

Active and Passive Radiative Transfer Modeling of the Olympic Mountains Experiment

Sensor forward models are an important tool for interpreting remote sensing observations of geophysical phenomena. By implementing a three-dimensional framework, we can simulate and analyze observations from various sensors on disparate platforms. To demonstrate our model framework, we simulate observations from the Olympic Mountains Experiment (OLYMPEX). The use of cloud model simulations allows us to understand sensor response to cloud ice, falling snow, and other processes and features, and the application of model tools to observations allows us to quantify precipitation.MIIST 3D Forward ModelThe Multi-Instrument Inverse Solver Testbed(MIIST) uses the Atmospheric Radiative TransferSimulator (ARTS) for solving the vector radiativetransfer (RT) equation in up to three spatialdimensions within a spherical geometry• Gas absorptiono Line-by-line calculationso Fast transmittance tables• Hydrometeor scattering solverso Discrete ordinateo RT4 (Evans, 1D)o Radar Single Scattering (1D or 3D)o Monte Carlo (3D)Scattering TablesHigh-fidelity hydrometeor scatteringtables are necessary for accurateand consistent forward modeling ofmulti-frequency observations• Requires full Stokes matriceso And absorption vector• Randomly oriented particleso Discrete Dipole Approximationo Characteristic Basis Function Method(coming soon)• Horizontally-oriented plateso Invariant Imbedding T-matrix MethodCloud Resolving SimulationsCloud resolving simulations (e.g.,NU-WRF) supply output consistentwith ARTS needs• Atmospheric Informationo Temperatureo Pressure / heighto Water vapor• Hydrometeor Profileso ARTS architecture ripe for explicit binmicrophysics• Examples use Morrison 2M schemeThe Olympic Mountains Experiment (OLYMPEX)Validation for GPM of mid-latitudefrontal systems approaching nearcoastalmountains from the ocean• Large collection of ground-based andairborne sensorso Radarso Radiometerso In situ• Contemporaneous with RADEXo Two sets of radar at same frequenciesRadiometer Simulation (3 km NUWRF, 20151203, 15:00)2018.12.14 7Simulate 166 GHz polarizationdifference• Corresponds to the presence of aligned icecrystals• Look at trends for both simulations andobservations• Simulations can tolerate lower resolutiono Larger domainSimulations from Observations: OLYMPEXSimulate sensor response usinggeophysical retrievals as input• Single frequency radar retrievals• Multiple scattering enhancementapparent at W band• Spatially dependent phenomenonModeling Application: 1D Retrievals03 December 2015• DC-8 and ER-2 flightso Focus on APR-3 (DC-8)• Citationo Stacked microphysics legso Qualitative comparisonso Range of frozen habitso Presence of supercooledliquid cloudsResults• Retrievals match probeso Good qualitative match• Bands of increasedreflectivity correspond tolarge Dm and highaggregate fraction• Significant amounts ofsupercooled liquid water

Adams, Ian S.↗

Modeling Offshore Wind Farm Performance in Coastal Low-Level Jets Using Coupled Mesoscale-Microscale Large Eddy Simulations

Accurately predicting wind farm reliability under complex offshore atmospheric conditions remains a key challenge, particularly during noncanonical meteorological events such as coastal low-level jets (LLJs). LLJs, characterized by strong nonmonotonic vertical shear and directional veer, depart significantly from the simplified inflow assumptions embedded in conventional design standards, low-fidelity engineering models, and microscale large eddy simulations of the atmospheric boundary layer. In this work, we use the virtual wind farm framework—an exascale, graphics processing unit–accelerated large eddy simulation platform coupled with high-fidelity aeroservoelastic turbine models and advanced mesoscale-microscale coupling via the ExaWind software stack—to investigate turbine responses under realistic LLJ forcing. Simulations are performed over the U.S. North Atlantic offshore domain with the use of meteorological inputs from New York State Energy Research and Development Authority buoy data, focusing on a representative LLJ case impacting the International Energy Agency 15 MW reference turbine. Our results show that LLJs can cause up to 50% power deficits in downstream turbine rows and significantly amplify low-speed shaft and tower loads through nonlinear coupling between complex inflow characteristics and turbine structural dynamics. Two primary mechanisms drive these load amplifications: (1) unique LLJ inflow features—including veer and vertical/lateral shear—and (2) the downstream evolution of the flow under stable thermal stratification, which suppresses turbulence mixing and alters wake recovery. These mechanisms produce streamwise variations in turbine loading not captured by standard hub height–based metrics or existing design load case (DLC) definitions. This study highlights the critical role of rotor-scale flow gradients in driving fatigue and system-level aeroelastic responses, challenging current DLC and control strategies. We advocate the integration of full-flow field, environment-aware wind inputs into load modeling and control algorithms. By leveraging exascale computing to resolve mesoscale-microscale coupling, this work lays the groundwork for next-generation offshore wind turbine design and operation in meteorologically complex marine environments.

17 WIND ENERGY↗

Device Voltage Stress from Ground Leakage Current in Medium-Voltage Solid-State Transformer

Grounding related issues are critical for safe and reliable operation of solid-state transformer (SST) in medium-voltage (MV) applications, e.g., solar photovoltaic and energy storage integration, date center, electric vehicle fast charging, etc. This article presents for the first time the issue of additional device voltage stress due to grounding-loop current in current-source SST, using the soft-switching solid-state transformer (S4T) as an example. The S4T features single-stage isolated AC-AC, AC-DC, or DC-DC conversion with full-range ZVS, derived from flyback converter or current-source converter (CSC). However, the flyback operation for CSC-based SST means that magnetizing current flows through the reverse-blocking devices on only one side of the medium-frequency transformer (MFT) at a time. Then, the voltages across the devices, especially those on the other side of the MFT, can be influenced by parasitic current. A parasitic model of a modular S4T (M-S4T) prototype is developed from direct measurements and datasheets. Using the developed parasitic model and equivalent circuits, the causes of the voltage stress are analyzed. A voltage-stress mitigation scheme of connecting additional grounding capacitors is proposed. Damping resistors are also installed to damp out the grounding-loop resonance. A robust parameter design of the proposed scheme is given. The existence of the voltage stress issue and the effectiveness of the proposed scheme are verified experimentally on an MV SiC M-S4T prototype with inherent parameter variations among the five modules in the prototype. Here, both single-module and stacked-module operation are demonstrated during steady state and dynamic conditions up to 4 kV peak.

42 ENGINEERING↗

The eROSITA Final Equatorial-Depth Survey (eFEDS)

Here, we investigate the physical properties – such as the stellar mass (M * ), star-formation rate, infrared (IR) luminosity (L IR ), X-ray luminosity (L X ), and hydrogen column density (N H ) – of mid-IR (MIR) galaxies and active galactic nuclei (AGN) at z < 4 in the 140 deg 2 field observed by eROSITA on SRG using the Performance-and-Verification-Phase program named the eROSITA Final Equatorial Depth Survey (eFEDS). By cross-matching the WISE 22 μm (W4)-detected sample and the eFEDS X-ray point-source catalog, we find that 692 extragalactic objects are detected by eROSITA. We have compiled a multiwavelength dataset extending from X-ray to far-IR wavelengths. We have also performed (i) an X-ray spectral analysis, (ii) spectral-energy-distribution fitting using X-CIGALE, (iii) 2D image-decomposition analysis using Subaru Hyper Suprime-Cam images, and (iv) optical spectral fitting with QSFit to investigate the AGN and host-galaxy properties. For 7088 WISE 22 μm objects that are undetected by eROSITA, we have performed an X-ray stacking analysis to examine the typical physical properties of these X-ray faint and probably obscured objects. We find that (i) 82% of the eFEDS–W4 sources are classified as X-ray AGN with log L X > 42 erg s –1 ; (ii) 67 and 24% of the objects have log(L IR /L ⊙ ) > 12 and 13, respectively; (iii) the relationship between L X and the 6 μm luminosity is consistent with that reported in previous works; and (iv) the relationship between the Eddington ratio and N H for the eFEDS–W4 sample and a comparison with a model prediction from a galaxy-merger simulation indicates that approximately 5.0% of the eFEDS–W4 sources in our sample are likely to be in an AGN-feedback phase, in which strong radiation pressure from the AGN blows out the surrounding material from the nuclear region. Thanks to the wide area coverage of eFEDS, we have been able to constrain the ranges of the physical properties of the WISE 22 μm-selected sample of AGNs at z < 4, providing a benchmark for forthcoming studies on a complete census of MIR galaxies selected from the full-depth eROSITA all-sky survey.

79 ASTRONOMY AND ASTROPHYSICS↗

Stacking the odds in favor of a space propulsion jackpot

When faced with a variety of technical options to solve a problem, program planners often try to identify one potential winner, then channel their resources into this option. The more scarce their resources are perceived to be, the more likely they are to fall into this trap of illogic. The real ideal solution could well be an optimum combination of options, not just one. Many propulsion opportunities are tantalizing solutions to the potentially high cost of travelling to other planets. Among these opportunities, nuclear thermal rockets (NTR), nuclear electric propulsion (NEP), and asteroid derived propellants stand out as high-payoff modest-challenge options, as near term as they are resolved to be made. But which to choose? Or should higher risk higher payoff technology be opted for, such as fusion? The approach advocated here, technoflex, is one that addresses NTR, NEP, and asteroid propellants in harmony rather than in isolation. Technoflex is technology rich, and option flexible. Technoflex should cost roughly the same as a classic phased technology elimination approach. The synergistic benefits amongst these three options, how they can be efficiently pursued together, and how they can fit with longer range technologies are stressed. Even if no single option reaches its highest expectations, the combinations of any two partial winners would still give big dividends. These combinations are cheap propellants in space, dual mode high thrust/low thrust, or versatile propellant NTR. The triple payoff is excellent, even if all three options would pan out below expectations. If only one option reaches its potential, it could make the other two still worth their investment. If all three options meet full expectations, the triple payoff is a space propulsion jackpot which makes concern about the initial investment ludicrous as well as open up the solar system to expedient exploration.

Willoughby, Alan J.↗

Outdoor Deployment Data for a Four-Terminal GaAs//Si Tandem Solar Mini-Module

This dataset contains the complete outdoor measurement and analysis data for a mechanically stacked, four-terminal (4T) gallium arsenide (GaAs)//silicon (Si) tandem solar mini-module deployed from October 2019 to January 2021 at the Solar Radiation Research Laboratory (SRRL) in Golden, Colorado, USA. The data support a performance modeling and degradation analysis framework for tandem photovoltaic devices, as described in the accompanying publication. The dataset includes: (1) current–voltage (J–V) characteristics of each sub-cell measured approximately every five minutes, with extracted performance parameters; (2) spectral irradiance from an EKO MS-710 WISER spectroradiometer, along with derived spectral mismatch ratios (SMR) and average photon energy (APE); (3) one-minute resolution meteorological data from the co-located SRRL weather station and GPS-derived precipitable water vapor (PWV); (4) pre-deployment laboratory characterization (external quantum efficiency, J–V curves, standard test conditions parameters); (5) outdoor-extracted temperature and PWV correction coefficients; and (6) PVcircuit equivalent-circuit simulation outputs used for model validation. Degradation rates of −4.1 ± 0.2 %/year (GaAs) and −2.5 ± 0.9 %/year (Si) were determined using a filtering and normalization methodology adapted for fixed-tilt tandem modules. All data are provided in open, portable formats (Apache Parquet, CSV, JSON) to enable full reproducibility of the published analysis.

14 SOLAR ENERGY↗

Drag of Several Gunner's Enclosures at High Speeds, Special Report

The drag of several types of gunner's turrets, windshields, blisters, and other protuberances, including projecting guns, was investigated at speeds from 75 to 440 miles per hour in the NACA 8-foot high-speed wind tunnel. The various gunner's enclosures were represented by 1/10 and 1/7 full-size models on a midwing-fuselage combination representative of bomber types. Most of the usual types of retractable turrets are very poor aerodynamically; they caused wind drag increments, dependent upon the size of the turret relative to the fuselage and upon the speed, up to twice the drag of the fuselage alone. A large streamline blister sufficient to enclose completely one type of rotating cylindrical turret caused a drag increment of approximately one-half that of the turret and at the same time provided space adequate for two gunners rather than for one gunner. A large portion of the drag increments for some types of turret appeared to be due to adverse effects on the fuselage flow caused by the turret rather than by the direct drag of the turret.

Stack, John↗

Highly Scalable Matching Pursuit Signal Decomposition Algorithm

Matching Pursuit Decomposition (MPD) is a powerful iterative algorithm for signal decomposition and feature extraction. MPD decomposes any signal into linear combinations of its dictionary elements or atoms . A best fit atom from an arbitrarily defined dictionary is determined through cross-correlation. The selected atom is subtracted from the signal and this procedure is repeated on the residual in the subsequent iterations until a stopping criterion is met. The reconstructed signal reveals the waveform structure of the original signal. However, a sufficiently large dictionary is required for an accurate reconstruction; this in return increases the computational burden of the algorithm, thus limiting its applicability and level of adoption. The purpose of this research is to improve the scalability and performance of the classical MPD algorithm. Correlation thresholds were defined to prune insignificant atoms from the dictionary. The Coarse-Fine Grids and Multiple Atom Extraction techniques were proposed to decrease the computational burden of the algorithm. The Coarse-Fine Grids method enabled the approximation and refinement of the parameters for the best fit atom. The ability to extract multiple atoms within a single iteration enhanced the effectiveness and efficiency of each iteration. These improvements were implemented to produce an improved Matching Pursuit Decomposition algorithm entitled MPD++. Disparate signal decomposition applications may require a particular emphasis of accuracy or computational efficiency. The prominence of the key signal features required for the proper signal classification dictates the level of accuracy necessary in the decomposition. The MPD++ algorithm may be easily adapted to accommodate the imposed requirements. Certain feature extraction applications may require rapid signal decomposition. The full potential of MPD++ may be utilized to produce incredible performance gains while extracting only slightly less energy than the standard algorithm. When the utmost accuracy must be achieved, the modified algorithm extracts atoms more conservatively but still exhibits computational gains over classical MPD. The MPD++ algorithm was demonstrated using an over-complete dictionary on real life data. Computational times were reduced by factors of 1.9 and 44 for the emphases of accuracy and performance, respectively. The modified algorithm extracted similar amounts of energy compared to classical MPD. The degree of the improvement in computational time depends on the complexity of the data, the initialization parameters, and the breadth of the dictionary. The results of the research confirm that the three modifications successfully improved the scalability and computational efficiency of the MPD algorithm. Correlation Thresholding decreased the time complexity by reducing the dictionary size. Multiple Atom Extraction also reduced the time complexity by decreasing the number of iterations required for a stopping criterion to be reached. The Course-Fine Grids technique enabled complicated atoms with numerous variable parameters to be effectively represented in the dictionary. Due to the nature of the three proposed modifications, they are capable of being stacked and have cumulative effects on the reduction of the time complexity.

Christensen, Daniel↗

Induction and Stabilization of Columnar Mesophases in Fluorinated Polycyclic Aromatic Hydrocarbons by Arene‐Perfluoroarene Interactions

Abstract The straightforward synthesis of several Fluorinated Polycyclic Aromatic Hydrocarbons by the efficient, transition‐metal‐free, arene fluorine nucleophilic substitution reaction is described, and the full investigation of their liquid crystalline and optical properties reported. The key precursors for this study, i. e. 2,2’‐dilithio‐4,4′,5,5′‐tetraalkoxy‐1,1’‐biphenyl derivatives, were obtained in two steps from the highly selective Scholl oxidative homo‐coupling of 3,4‐dialkoxy‐1‐bromobenzene, followed by quantitative double‐lithiation. In situ room temperature nucleophilic annulation with either perfluorobenzene or perfluoronaphthalene leads to 1,2,3,4‐tetrafluoro‐6,7,10,11‐tetraalkxoytriphenylenes and 9,10,11,12,13,14‐hexafluoro‐2,3,6,7‐tetraalkoxybenzo[f]tetraphenes, respectively, in good yields. Exploiting the same strategy, subsequent double annulations resulted in the formation of 9,18‐difluoro‐2,3,6,7,11,12,15,16‐octa(alkoxy)tribenzo[f,k,m]tetraphenes and 9,10,19,20‐tetrafluoro‐2,3,6,7,12,13,16,17‐octakis(hexyloxy)tetrabenzo[a,c,j,l]tetracenes, respectively. Despite the presence of only four alkoxy chains, the polar “Janus” mesogens display a columnar hexagonal mesophase over broad temperature ranges, with higher mesophase stability than the archetypical 2,3,6,7,10,11‐hexa(alkoxy)triphenylenes and their hydrogenated counterparts. The improvement or induction of mesomorphism is attributed to efficient antiparallel face‐to‐face π‐stacking driven by the establishment of non‐covalent perfluoroarene‐arene intermolecular interactions. The larger lipophilic discotic π‐extended compounds also exhibit columnar mesomorphism, over similar temperature ranges and stability than their hydrogenated homologs. Finally, these fluorinated molecules form stringy gels in various solvents, and show interesting solvatochromic emission properties in solution as well as strong emission in thin films and gels.

Chemistry↗

Effect of electrode rinse solutions on the electrodialysis of concentrated salts

The data presented indicate that modest attention to the chemistry of the electrode rinse solution can yield as much as 56% improvement in process efficiency. When operating electrodialysis (ED) with salt concentrations greater than 10,000 mg/l (as NaCl) the amperage can be relatively high even at low voltages. To maximize the overall rate of ion transport from diluate to concentrate, there is a need to minimize resistances in the electrode cells since these can represent as much as 30% of the total resistances in the entire process and in this particular ED unit, represented resistance roughly equivalent to that within the membrane stack. This work describes the performance of a 10-cell pair, 200 cm 2 (0.02 m 2 ) per membrane, pilot ED unit operated in batch mode at 5 V potential. The feedstock to the stack was varied from 0.5% to 6% NaCl. Results from Volt-amp profiles (2.0–15 V) were used as the rationale for choosing the preferred electrode rinse solution, 90 g/l (kg/m 3 ) disodium sulfate at pH 12.5. The recommended solution of 30 g/l (kg/m 3 ) disodium sulfate at neutral pH was tested against stronger solutions (60, 90, and 120 g/l (kg/m 3 ) disodium sulfate) at neutral pH and with 1 g/l (kg/m 3 ) sodium hydroxide added to yield solutions at pH 12.5. There were stark differences in the performance of the ED unit between the solutions at pH 7 and those at pH 12.5. The slopes of the Volt-amp profiles improved indicating less resistance to ion flow at pH 12.5. Most of the difference can be attributed to the greater conductivity of sodium hydroxide compared to disodium sulfate, where even a modest addition of 1 g/l (kg/m 3 ) sodium hydroxide increased the conductivity of the solution between 8 and 20% depending on the concentration of disodium sulfate. Most notably, the initiation voltage was 2.39 ± 0.08 V with solutions at pH 7 and 1.99 V ± 0.04 V when the rinse solutions were around pH 12.5, a difference of around 0.42 V. Since the full batch runs were performed at 5.0 V, this 0.42 V differential represented a loss of 8% in process efficiency. A series of tests showed a shift in initiation voltage occurred between pH 11.5 and 12.5. Nernst equations for water electrolysis are coupled with a simple flux model that estimates the concentration of hydroxide and hydronium ions at the electrode surfaces. This model indicates that the potential demanded by the electrodes is directly linked to the current. Furthermore, there is a steep drop in the potential demanded by the anode when there is sufficient hydroxide available to generate oxygen from hydroxide as opposed to generation from water. The voltage demand is minimal at pH 12.5 and reflective of the reference standard voltage (just over 1.23 V predicted at 0.1 amps). However, the flux model predicts that the voltage demanded by the electrodes at pH 7 is 1.61 V at 0.1 amps (the lowest amperage measurable with the power pack). In conclusion, comparing this result to the reference standard (E 0 = -1.23 V) yields a satisfactory explanation for the observed difference below reference standard of 0.42 V.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

FEED Study of Carbon Capture Inc. DAC and CarbonCure Utilization Using United States Steel's Gary Works Waste Plant

Direct Air Capture (DAC) has been proposed as a means of reducing atmospheric concentrations of CO2. While DAC has been evaluated through lab-scale, bench-scale, and small-scale pilot units, large-scale deployment has not been achieved. Feasibility studies are one tool to understand the potential design, operation, performance, and impact of commercial-scale DAC. This paper presents the results of a feasibility study for a passive DAC system deployed at >100,000 tpy scale in three different regions across the U.S. and awarded to Carbon Collect by the U.S. Department of Energy National Energy Technology Laboratory (DOE NETL). The MechanicalTree™technology has been designed and engineered by Carbon Collect based on the concept initially developed at Arizona State University Center for Negative Carbon Emissions. It uses a tower of stacked, sorbentcontaining disks supported by a lifting mechanism, exposed to the air to capture CO2 during the adsorption phase. The disks are then lowered into a regeneration chamber for vacuum and steam regeneration to produce CO2 product during the desorption step. The modular tree design allows large installations with repeatable, mass-manufactured units connected to common utilities such as steam supply, vacuum, and CO2 processing for compression and geologic storage. The passive DAC system eliminates the equipment and energy of forced air fans by using natural air circulation to contact the sorbent with the CO2 in the air. Because of this, the performance is dependent on the wind speed in addition to the temperature and relative humidity. Performance and flow rate fluctuations were incorporated into equipment and facility design with considerations for turndown to 10% of maximum rated flow to allow operation in all seasons. The feasibility study was undertaken to evaluate the technology in different regions and climates. Three locations were selected for this study representing different climates: Alabama (hot and humid), California (hot and arid), and Wyoming (continental). For each region, the adsorption/desorption cycle was optimized including tuning the heat integration and cycle timings. The performance of individual trees was then scaled to the full facility with the same design of more than 20,000 trees common between all regions. The installations had expected average CO2 capture rates of between 330,000 and 485,000 tonnes of CO2 per year depending on the climate. The initial engineering design for the facility at each location was performed with cost and performance estimates for the trees, carbon purification and compression, and the balance of plant. To supply thermal and electrical energy for the facility, carbon-free or low-carbon power must be considered. Options for low-carbon, continuous thermal and electrical energy were considered. The best-performing option from those considered was identified to be an electrically-heated molten salt energy storage system, powered by an on-site photovoltaic field. During molten salt thermal discharge, steam is produced from heat exchange with the molten salt and used to generate power in a steam turbine as well as steam for regenerating the DAC carbon trees. The thermal and electrical supply and analysis is presented in the context of low-carbon power for carbon removal. Modelling and economics of transportation and geologic storage of the CO2 is considered and presented for each location. The results of the feasibility study are incorporated into the presented techno-economic and life-cycle assessments. This work is intended to provide an understanding of the performance, cost, and impact of capturing CO2 at the commercial scale and the impact of climate and regional siting on the considered passive DAC system.