Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fringe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Waveguide detuning caused by transverse magnetic fields on a simulated in-line 6 MV linac

Purpose: Due to the close proximity of the linear accelerator (linac) to the magnetic resonance (MR) imager in linac-MR systems, it will be subjected to magnet fringe fields larger than the Earth's magnetic field of 5x10{sup -5} T. Even with passive or active shielding designed to reduce these fields, some magnitude of the magnetic field is still expected to intersect the linac, causing electron deflection and beam loss. This beam loss, resulting from magnetic fields that cannot be eliminated with shielding, can cause a detuning of the waveguide due to excessive heating. The detuning, if significant, could lead to an even further decrease in output above what would be expected strictly from electron deflections caused by an external magnetic field. Thus an investigation of detuning was performed through various simulations. Methods: According to the Lorentz force, the electrons will be deflected away from their straight course to the target, depositing energy as they impact the linac copper waveguide. The deposited energy would lead to a heating and deformation of the copper structure resulting in resonant frequency changes. PARMELA was used to determine the mean energy and fraction of total beam lost in each linac cavity. The energy deposited into the copper waveguide from the beam losses caused by transverse magnetic fields was calculated using the Monte Carlo program DOSRZnrc. From the total energy deposited, the rise in temperature and ultimately the deformation of the structure was estimated. The deformed structure was modeled using the finite element method program COMSOL MULTIPHYSICS to determine the change in cavity resonant frequency. Results: The largest changes in resonant frequency were found in the first two accelerating cavities for each field strength investigated. This was caused by a high electron fluence impacting the waveguide inner structures coupled with their low kinetic energies. At each field strength investigated, the total change in accelerator frequency was less than a manufacturing tolerance of 10 kHz and is thus not expected to have a noticeable effect on accelerator performance. Conclusions: The amount of beam loss caused by magnetic fringe fields for a linac in a linac-MR system depends on the effectiveness of its magnetic shielding. Despite the best efforts to shield the linac from the magnetic fringe fields, some persistent magnetic field is expected which would result in electron beam loss. This investigation showed that the detuning of the waveguide caused by additional electron beam loss in persistent magnetic fields is not a concern.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High energy x-ray phase contrast CT using glancing-angle grating interferometers

Purpose: The authors present initial progress toward a clinically compatible x-ray phase contrast CT system, using glancing-angle x-ray grating interferometry to provide high contrast soft tissue images at estimated by computer simulation dose levels comparable to conventional absorption based CT. Methods: DPC-CT scans of a joint phantom and of soft tissues were performed in order to answer several important questions from a clinical setup point of view. A comparison between high and low fringe visibility systems is presented. The standard phase stepping method was compared with sliding window interlaced scanning. Using estimated dose values obtained with a Monte-Carlo code the authors studied the dependence of the phase image contrast on exposure time and dose. Results: Using a glancing angle interferometer at high x-ray energy (∼45 keV mean value) in combination with a conventional x-ray tube the authors achieved fringe visibility values of nearly 50%, never reported before. High fringe visibility is shown to be an indispensable parameter for a potential clinical scanner. Sliding window interlaced scanning proved to have higher SNRs and CNRs in a region of interest and to also be a crucial part of a low dose CT system. DPC-CT images of a soft tissue phantom at exposures in the range typical for absorption based CT of musculoskeletal extremities were obtained. Assuming a human knee as the CT target, good soft tissue phase contrast could be obtained at an estimated absorbed dose level around 8 mGy, similar to conventional CT. Conclusions: DPC-CT with glancing-angle interferometers provides improved soft tissue contrast over absorption CT even at clinically compatible dose levels (estimated by a Monte-Carlo computer simulation). Further steps in image processing, data reconstruction, and spectral matching could make the technique fully clinically compatible. Nevertheless, due to its increased scan time and complexity the technique should be thought of not as replacing, but as complimentary to conventional CT, to be used in specific applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-G-BRD-09: Novel MRI Compatible Electron Accelerator for MRI-Linac Radiotherapy

Purpose: MRI guided radiotherapy is a rapidly growing field; however current linacs are not designed to operate in MRI fringe fields. As such, current MRI- Linac systems require magnetic shielding, impairing MR image quality and system flexibility. Here, we present a bespoke electron accelerator concept with robust operation in in-line magnetic fields. Methods: For in-line MRI-Linac systems, electron gun performance is the major constraint on accelerator performance. To overcome this, we propose placing a cathode directly within the first accelerating cavity. Such a configuration is used extensively in high energy particle physics, but not previously for radiotherapy. Benchmarked computational modelling (CST, Darmstadt, Germany) was employed to design and assess a 5.5 cell side coupled accelerator with a temperature limited thermionic cathode in the first accelerating cell. This simulation was coupled to magnetic fields from a 1T MRI model to assess robustness in magnetic fields for Source to Isocenter Distance between 1 and 2 meters. Performance was compared to a conventional electron gun based system in the same magnetic field. Results: A temperature limited cathode (work function 1.8eV, temperature 1245K, emission constant 60A/K/cm{sup 2}) will emit a mean current density of 24mA/mm{sup 2} (Richardson’s Law). We modeled a circular cathode with radius 2mm and mean current 300mA. Capture efficiency of the device was 43%, resulting in target current of 130 mA. The electron beam had a FWHM of 0.2mm, and mean energy of 5.9MeV (interquartile spread of 0.1MeV). Such an electron beam is suitable for radiotherapy, comparing favourably to conventional systems. This model was robust to operation the MRI fringe field, with a maximum current loss of 6% compared to 85% for the conventional system. Conclusion: The bespoke electron accelerator is robust to operation in in-line magnetic fields. This will enable MRI-Linacs with no accelerator magnetic shielding, and minimise painstaking optimisation of the MRI fringe field. This work was supported by US (NIH) and Australian (NHMRC & Cancer Institute NSW) government research funding. In addition, I would like to thank cancer institute NSW and the Ingham Institute for scholarship support.

60 APPLIED LIFE SCIENCES↗

X-ray Moiré deflectometry using synthetic reference images

Moiré fringe deflectometry with grating interferometers is a technique that enables refraction-based x-ray imaging using a single exposure of an object. To obtain the refraction image, the method requires a reference fringe pattern (without the object). Our study shows that, in order to avoid artifacts, the reference pattern must be exactly matched in phase with the object fringe pattern. In experiments, however, it is difficult to produce a perfectly matched reference pattern due to unavoidable interferometer drifts. We present a simple method to obtain matched reference patterns using a phase-scan procedure to generate synthetic Moiré images. As a result, the method will enable deflectometric diagnostics of transient phenomena such as laser-produced plasmas and could improve the sensitivity and accuracy of medical phase-contrast imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Modelling Curvilinear Beamline Effects on Beam- and Spin-Dynamics in the Fermilab Muon g-2 Storage Ring.

A model of the Fermilab Muon g-2 Experiment storage ring is developed with the BMAD simulation library for beam- and spin-dynamics studies. Particular focus is given to the electrostatic quadrupoles, the plates of which follow the curvature of the particle design trajectory of the magnetically uniform storage ring. To model these, standard electric multipoles and a novel method based on cylindrical harmonics are investigated and found to accurately match the electric field maps produced for the bulk and fringe regions of the curved quadrupoles respectively, despite these methods being specifically for straight beamlines. The toroidal multipole description is then developed, to include curvature and longitudinal field variations (to model the fringe field regions). Various combinations of the different descriptions (including use of the field maps) are used for the bulk and fringe fields of the quadrupoles, and the toroidal multipoles are found to provide the best agreement with the measured tunes of the storage ring. Two integrators are also developed, based on the method of Wu, Forest and Robin. The first of these describes motion in a uniform magnetic dipole field with arbitrary electric field, and produces results comparable to those of the adaptive-step fourth-order Runge–Kutta integrator implemented in BMAD, suitable for tracking over thousands of turns. The second is a generalisation of the first to arbitrary magnetic vector potentials superimposed on that of the uniform dipole, with arbitrary electric fields, and was also found to agree with the Runge–Kutta integrator. Simulations of antimuon storage for 2000 turns of the storage ring were performed, where losses were studied along with the evolution of beam polarisation. The storage losses, important for reducing the systematic error in the measurement of the muon g-2, were found to be largely due to collimator shape. The correlation between momentum and spin precession frequency reflect the effects expected from the electric field correction in the T-BMT equation, on the order of 10 -6 . Particle injection was also studied, for various injection angles, quadrupole strengths and strengths of injection kick, and in the cases where experimental data was provided, the model was found to be consistent with the experiment.

43 PARTICLE ACCELERATORS↗

Measurements of the Dielectric Properties of Thin High-Explosive Samples Using a Parallel Plate Test Fixture

This report presents results of a study of the dielectric properties of several high explosive materials, including Composition B, C-4, Detasheet, Semtex 1A, Semtex 1H, and Semtex 10. The capacitance and dispersion of samples up to ten mm thick were measured at 24 and 65°C using a parallel plate test fixture. In this configuration, capacitance is proportional to the real component of the complex dielectric constant (or permittivity) of the material, while the dispersion is equal to the imaginary component of the dielectric constant divided by the real component. Measurements were performed at two temperatures to determine whether these dielectric properties might be used to monitor moderate temperature changes within these materials using an external fringing field capacitor. It was found that the real dielectric constant of the high explosives generally changed by only about 1% on heating from 24 to 65°C, and that the externally measured capacitance is therefore not a reliable parameter for monitoring temperature changes in these explosives. Temperature- based changes in the dispersion were often 20% or greater, and for several materials (e.g., Composition B, Detasheet) the temperature and dispersion showed good correlation as the temperature of the explosive was cycled up and down. It is thus possible that for some high explosives the externally measured dispersion is a useful parameter for monitoring temperature changes. However, other factors may limit the usefulness of this technique, including the need to have the plates of a fringing field capacitor in direct contact with the high explosive to obtain measurements, and the limited penetration depth of the fringing field into the explosive material.

36 MATERIALS SCIENCE↗

Silicon Consortium Project: No-Go on Moir Interferometry for Measuring SEI Strain as a Probe for Calendar Life Testing

Silicon is a promising candidate as a next generation anode to replace or complement graphite electrodes due to its high energy density and low lithiation potential. When silicon is lithiated, it experiences over 300% expansion which stresses the silicon as well as its solid electrolyte interphase (SEI) leading to poor performance. The use of nano-sized silicon has helped to mitigate volume expansion and stress in the silicon, yet the silicon SEI is still both mechanically and chemically unstable. Identifying the mechanical failure mechanism of the SEI will help enhance calendar and cycle life performance through improved SEI design. In situ moiré interferometry was investigated to try and track the in-plane strain in the SEI and silicon electrode for this purpose. Moiré can detect on the order of 10 nm changes in displacement and is therefore a useful tool in the measurement of strain. As the sample undergoes small deformations, large changes in the moiré fringe allow for measurements of displacement below the diffraction limit of light. Figure 1a shows how the moiré fringe changes as the sample grating deforms. As the sample contracts or expands, the frequency of the moiré fringe changes, and this change is proportional to the strain in the sample.

36 MATERIALS SCIENCE↗

Search for Q ~0 Order near a Forbidden Bragg Position in Bi 2.1 Sr 1.9 CaCu 2 O 8+x with Resonant Soft X-ray Scattering

Identifying what broken symmetries are present in the cuprates has become a major area of research. Many authors have reported evidence for so-called “Q ~ 0” order that involves broken inversion, mirror, chiral, or time-reversal symmetry that is uniform in space. Not all these observations are well understood and new experimental probes are needed. Here we use resonant soft x-ray scattering (RSXS) to search for Q ~ 0 order in Bi 2.1 Sr 1.9 CaCu 2 O 8+x (Bi-2212) by measuring the region of a forbidden Bragg peak, (0,0,3), which is normally extinguished by symmetry but may become allowed on resonance if valence band order is present. Using circularly polarized light, we found that this reflection becomes allowed on the CuL 3 resonance for temperatures T c < T < T*, though remains absent in linear polarization and at other temperatures. This observation suggests the existence of spatially uniform valence band order near the pseudogap temperature. In addition, we observed periodic oscillations in the specular reflectivity from the sample surface that resemble thin film interference fringes, though no known film is present. These fringes are highly resonant, appear in all polarizations, and exhibit a period that depends on the location where the beam strikes the sample surface. We speculate that these fringes arise from interaction between some intrinsic valence band instability and extrinsic structural surface morphologies of the material. Our study supports the existence of some kind of Q ~ 0 broken symmetry state in Bi-2212 at intermediate temperatures. Further studies using a microfocused beam, which could disentangle microscopic effects from macroscopic heterogeneities, are needed to ascertain the universality of the effect.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A simplified holographic-interferometry technique for real-time flow visualization and analysis

A holographic-interferometry technique for flow visualization and analysis that produces real-time moire fringes is described from both experimental and application considerations. It has three chief advantages: real-time data for continuous observation and photography, ease of optical adjustment, and capability of using ordinary-glass test-section windows without affecting the results. A theoretical discussion is presented describing the formation of the fringes in holographic terms and then comparing this result to that which is obtained from a conventional moire approach. A discussion on obtaining density information from the fringe pattern is also included.

Long, S. A.↗

Apparatus for providing a servo drive signal in a high-speed stepping interferometer

An analog voltage approximately linearly proportional to a desired offset from the present null position of a moving mirror in an interferometer is applied to the mirror moving means. As the mirror moves to the next null position, as determined by the analog voltage, the fringes of a laser reference interference pattern are detected. At the occurrence of each fringe the analog voltage is reduced proportionally so that when the next null position is reached, this driving analog is effectively zero. A binary up/down counter, by its internal count, causes a digital/analog converter to supply the analog voltage to the mirror moving means. Fringe detection and direction of movement logic cause the binary up/down counter to be decremented from its offset count as the mirror is moved to the new null position. Undesirable movement of the mirror due to vibration or other sources causes a correcting drive signal to be applied to the mirror moving means that is proportional to the distance of movement.

Schindler, R. A.↗

Laser angle measurement system

The design and fabrication of a laser angle measurement system is described. The instrument is a fringe counting interferometer that monitors the pitch attitude of a model in a wind tunnel. A laser source and detector are mounted above the mode. Interference fringes are generated by a small passive element on the model. The fringe count is accumulated and displayed by a processor in the wind tunnel control room. Optical and electrical schematics, system maintenance and operation procedures are included, and the results of a demonstration test are given.

Pond, C. R.↗

Measurement potential of laser speckle velocimetry

Laser speckle velocimetry, the measurement of fluid velocity by measuring the translation of speckle pattern or individual particles that are moving with the fluid, is described. The measurement is accomplished by illuminating the fluid with consecutive pulses of Laser Light and recording the images of the particles or the speckles on a double exposed photographic plate. The plate contains flow information throughout the image plane so that a single double exposure may provide data at hundreds or thousands of points in the illuminated region of the fluid. Conventional interrogation of the specklegram involves illuminating the plate to form Young's fringes, whose spacing is inversely proportional to the speckle separation. Subsequently the fringes are digitized and analyzed in a computer to determine their frequency and orientation, yielding the velocity magnitude and orientation. The Young's fringe technique is equivalent to performing a 2-D spatial correlation of the double exposed specklegram intensity pattern, and this observation suggests that correlation should be considered as an alternative processing method. The principle of the correlation technique is examined.

Adrian, R. J.↗

Holographic interferometry of transparent media using light scattered by embedded test objects

Fringe formation and localization in holographic interferometry of transparent media are discussed for configurations in which light enters the medium and is scattered back through it by an embedded diffuse object. Fringe order numbers are doubled, and the fringe localization region is translated and compressed by a factor of two. The results are applicable to tomographic reconstruction of aerodynamic density fields around opaque test objects.

Prikryl, I.↗

Interferometric angle monitor

Two mutually coherent light beams formed from a single monochromatic light source were directed to a reflecting surface of a rotatable object. They were reflected into an imaging optical lens having a focal plane optically at infinity. A series of interference fringes were formed in the focal plane which were translated linearly in response to angular rotation of the object. Photodetectors were located adjacent the focal plane to detect the fringe translation and output a signal in response to the translation. The signal was fed to a signal processor which was adapted to count the number of fringes detected and develop a measure of the angular rotation and direction of the object.

Minott, P. O.↗

Multiple telescope infrared interferometry

The advantages of multiple telescope infrared interferometry are discussed in detail, using the 10 micron region as a specific example. Scale and seeing considerations are addressed, taking into account analytically the distorting effect of turbulent air and discussing the effect of water vapor on seeing. The usefulness of fringe phase determination to determine the intensities in the radiation field, and the effect of atmospheric fluctuations on their use, are considered. Astrometry by means of interferometry is extensively covered, with examples such as a plot of the fringe phase of o Ceti as a function of time compared with a theoretical fringe phase of the star with a fixed best-fit baseline. The sensitivity of an interferometer involving two receiving telescopes is considered. Finally, an example of a telescope design for 10-micron interferometry is described and depicted.

Townes, C. H.↗

Analysis and testing of a new method for drop size and velocity measurements using laser light scatter interferometry

Drop size and velocity can be measured simultaneously using an optical system which is the same as a laser Doppler velocimeter except that three detectors are located at selected spacings behind the receiver aperture. Drops passing through the intersection of the two beams scatter light which produces an interferrence fringe pattern. The temporal frequency of the fringe pattern is the Doppler difference frequency which is linearly proportional to the drop velocity while the spatial frequency is linearly related to the drop diameter. The spacing of the fringes is also dependent upon the light wavelength, beam intersection angle, drop refractive index (unless reflected light is measured), and the location of the receiver. The theoretical analysis was verified, signal phase processing methods were evaluated, and the effects of signal quality upon the measurements were investigated.

Bachalo, W. D.↗

Isopachic contouring of opaque plates

Contour maps of change of thickness of opaque plates subjected to external loads are obtained using holographic interferometry in conjunction with the moire effect. A simple holographic-interferometry arrangement is used first to obtain contour maps of the out-of-plane displacements of the two sides of the object. Carrier patterns of equal magnitude but opposite signs are added to these contours. Superposition of the reconstructed holograms of the two sides produces a pattern of additive-moire fringes, which are contours of change of thickness. Effects of midplane warpage of the loaded specimen are cancelled. Sensitivity is lambda/2 per fringe order, contrast of the isopachic-fringe pattern is excellent, and the process is compatible with a mechanical-testing-machine environment.

Post, D.↗

Brewster-Plate Spoiler for Laser Spectrometer

Oscillating Brewster plate reduces effects of unwanted interference fringes on absorption-spectroscopic measurements obtained with tuned diode lasers. Plate modulates optical-path length past several resonance peaks causing interference fringes to pass by rapidly and become blurred. Thus, fringe effects averaged out over time. Technique used at other wavelengths from ultraviolet to infrared and in spectrometers with short or long optical paths, including those with retroreflectors or multipass cells.

Webster, C. R.↗