Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “frequency measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Measurement of a radial flow profile with eddy current flow meters and deep neural networks

Eddy current flow meters (ECFMs) measure flows of conductive fluids. Recent interest in ECFMs has increased due to applications in advanced nuclear reactors. ECFMs are well suited for such applications, as they can provide non-invasive measurements of flow in fluids that are often difficult to measure. Traditionally, ECFMs are operated using an alternating current at a single frequency, limiting ECFMs to measure average fluid velocities, blockages, or voids. Here, we expand the capabilities of ECFMs by measuring the fluid radial velocity profile of liquid mercury. To accomplish this, we made several ECFM sensitivity measurements at a range of frequencies. Different frequencies vary the electromagnetic skin depth of the device. By adjusting frequencies, we probed the fluid velocity at various radial locations and constructed a flow-velocity profile. The relationship between the ECFM measurements and velocity profile is nonlinear and requires solving an inverse problem. Using electromagnetic finite-element simulations to train a deep neural network (DNN), we created a model that provides a stable general relationship between the sensitivity measurements of an ECFM and the fluid velocity profile. Using ECFM measurements of liquid mercury, our DNN model calculates a flow profile that agrees well with computational fluid dynamics (CFD) simulations. This technique has potential to improve flow monitoring for optimization, safe operation of conductive fluid loops, and/or validating complex CFD models.

47 OTHER INSTRUMENTATION↗

Eulerian and Lagrangian second-order statistics of superfluid 4 He grid turbulence

Here, we use particle-tracking velocimetry to study Eulerian and Lagrangian second-order statistics of superfluid 4 He grid turbulence. The Eulerian energy spectra at scales larger than the mean distance between quantum vortex lines behave classically with close to Kolmogorov-1941 scaling and are almost isotropic. The Lagrangian second-order structure functions and frequency power spectra, measured at scales comparable with the intervortex distance, demonstrate a sharp transition from nearly classical behavior to a regime dominated by the motion of quantum vortex lines. Employing the homogeneity of the flow, we verify a set of relations that connect various second-order statistical objects that stress different aspects of turbulent behavior, allowing a multifaceted analysis. We use the two-way bridge relations between Eulerian energy spectra and second-order structure functions to reconstruct the energy spectrum from the known second-order velocity structure function and vice versa. The Lagrangian frequency spectrum reconstructed from the measured Eulerian spectrum using the Eulerian-Lagrangian bridge differs from the measured Lagrangian spectrum in the quasiclassical range, which calls for further investigation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Topological quantum computation on a chiral Kondo chain

We describe the chiral Kondo chain model based on the symplectic Kondo effect and demonstrate that it has a quantum critical ground state populated by non-Abelian anyons. We show that the fusion channel of two arbitrary anyons can be detected by locally coupling the two anyons to an extra single channel of chiral current and measuring the corresponding conductance at a finite frequency. Based on such measurements, we propose that the chiral Kondo chain model with symplectic symmetry can be used for the implementation of measurement-only topological quantum computations, and it possesses several distinct features favorable for such applications. Furthermore, the sources and effects of errors in the proposed system are analyzed and possible material realizations are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Forced Oscillation Source Location in Power Systems Using MVMD-assisted DEF in TF Plane

Fast and accurate forced oscillation source location (FOSL) is critical for mitigating forced oscillations in power systems. Here, to overcome the shortcomings of traditional dissipating energy flow (DEF) in decomposing the forced oscillation components from the measurement responses, a multivariate variational mode decomposition (MVMD)-assisted FOSL is proposed in this paper to locate the forced oscillation sources from measurements in time-frequency (TF) plane. The multi-channel measurement matrix of each generator is formed, then the multi-channel modes are decomposed from the formed multi-channel measurement matrix using the MVMD. Further, the intrinsic mode functions (IMFs) associated with the forced oscillation mode are distinguished from the decomposed modes according to the relative energy weights. With the distinguished IMFs, the MVMD-assisted DEF calculation method is developed to locate the forced oscillation source. Finally, the performance of the proposed method is evaluated using the simulation data of the WECC 179-bus test system and IEEE-NASPI Oscillation Source Location Contest as well as the actual PMU data of ISO New England. The results validated the effectiveness and accuracy of the proposed method in the FOSL.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Vibrational and electronic properties of Np 2 O 5 from experimental spectroscopy and first principles calculations

High-valence actinide oxides are critical to understanding the behavior of 5f-electrons, yet their structural and electronic properties remain poorly understood due to challenges in synthesis and handling. We report the first Raman spectroscopic study of single-crystalline Np 2 O 5 and the first scanning tunneling spectroscopy (STS) measurement on any neptunium-containing material. Hydrothermally synthesized crystals were structurally verified by X-ray diffraction. Raman spectra revealed sharply resolved vibrational features, including previously unreported low-frequency modes. STS measurements revealed a band gap of 1.5 eV. Density functional theory (DFT) enables vibrational mode assignments, reveals neptunium-dominated low-frequency phonons, oxygen-dominated high-frequency modes, and predicts an indirect band gap of 1.68 eV. This predicted value is in excellent agreement with the experimentally measured STS gap. This combined Raman, DFT, and STS approach provides a robust framework for correlating lattice dynamics and electronic structure in actinide materials, providing benchmark data for Np 2 O 5 , and opening new avenues for probing structure–property relationships in complex f-electron materials.

36 - MATERIALS SCIENCE↗

Probing local electron temperature and density inside a sheared flow stabilized Z-pinch using portable optical Thomson scattering

We report the first optical Thomson scattering measurements inside a high electron temperature (≳1 keV) and moderate electron density (mid 10 16 cm –3 ) plasma. This diagnostic has been built to provide critical plasma parameters, such as electron temperature and density, for Advanced Research Projects Agency-Energy-supported fusion-energy concepts. It uses an 8 J laser at 532 nm in 1.5 ns to measure the high frequency feature of the Thomson scattering profile at 17 locations along the probe axis. It is able to measure electron density from 5 × 10 17 cm –3 to several 10 19 cm –3 and electron temperatures from tens of eV to several keV. Here, in this paper, we describe the design, deployment, and analysis on the sheared flow stabilized Z-pinch machine at Zap Energy named FuZE. The probe beam is aimed at an axial distance of 20 cm from the central electrode and is timed within the temporal envelope of neutron emission. The high temperature and moderate density plasmas generated on FuZE lie in an unconventional regime for Thomson scattering as they are between tokamaks and laser-produced plasmas. We described the analysis considerations in this regime, show that the electron density was below 5 × 10 16 cm –3 at all times during these measurements, and present a sample shot where the inferred electron temperature varied from 167 ± 16 eV to 700 ± 85 eV over 1.6 cm.

47 OTHER INSTRUMENTATION↗

FAST.Farm load validation for single wake situations at alpha ventus

The main objective of the presented work is the validation of the simulation tool FAST.Farm for the calculation of power and structural loads in single wake situations; the basis for the validation is the measurement database of the operating offshore wind farm alpha ventus. The approach is described in detail and covers the calibration of the aeroelastic turbine model, transfer of environmental conditions to simulations, and comparison between simulations and adequately filtered measurements. It is shown that FAST.Farm accurately predicts power and structural load distributions over wind direction with discrepancies of less than 10 % for most of the cases compared to the measurements. Additionally, the frequency response of the structure is investigated, and it is calculated by FAST.Farm in good agreement with the measurements. In general, the calculation of fatigue loads is improved with a wake-added turbulence model added to FAST.Farm in the course of this study.

17 WIND ENERGY↗

In-situ measurements of chemically and radiatively important atmospheric gases from the Advanced Global Atmospheric Gas Experiment (AGAGE) and affiliated stations.

In the ALE/GAGE/AGAGE global network program, continuous high frequency gas chromatographic measurements of four biogenic/anthropogenic gases (methane, CH4; nitrous oxide, N2O; hydrogen, H2; and carbon monoxide, CO) and several anthropogenic gases that contribute to stratospheric ozone destruction and/or to the greenhouse effect have been carried out at five globally distributed sites for several years. The program, which began in 1978, is divided into three parts associated with three changes in instrumentation: the Atmospheric Lifetime Experiment (ALE), which used Hewlett Packard HP5840 gas chromatographs; the Global Atmospheric Gases Experiment (GAGE), which used HP5880 gas chromatographs; and the present Advanced GAGE (AGAGE). AGAGE uses two types of instruments: a gas chromatograph with multiple detectors (GC-MD), and a gas chromatograph with mass spectrometric analysis (GC-MS). Beginning in January 2004, an improved cryogenic preconcentration system (Medusa) replaced the absorption-desorption module in the GC-MS systems at Mace Head and Cape Grim; this provided improved capability to measure a broader range of volatile perfluorocarbons with high global warming potentials. The Medusa GC-MS systems were subsequently used at other AGAGE stations (Trinidad Head, Barbados, American Samoa, Zeppelin, Jungfraujoch, and Goan) after the initial setup at Mace Head and Cape Grim. More information may be found at the AGAGE home page: https://agage.mit.edu/instruments.Compared to the previous version (https://data.ess-dive.lbl.gov/view/doi:10.3334/CDIAC/ATG.DB1001), the latest update (Agage_gcmd_gcms_data_2021_04_07_tar.gz) includes 6 months of new data through the end of March 2020. Two new compounds, HCFC-132b, and HCFC-133a, are also included in this version. For a complete list of released compounds and used standard scales, please see “AGAGE_scale_2021_v1.pdf” file. Additional information can also be found on the AGAGE website (https://agage.mit.edu).

54 ENVIRONMENTAL SCIENCES↗

The dataset of in-situ measurements of chemically and radiatively important atmospheric gases from the Advanced Global Atmospheric Gas Experiment (AGAGE) and affiliated stations (2023R1)

In the ALE/GAGE/AGAGE global network program, continuous high frequency gas chromatographic measurements of four biogenic/anthropogenic gases (methane, CH4; nitrous oxide, N2O; hydrogen, H2; and carbon monoxide, CO) and several anthropogenic gases that contribute to stratospheric ozone destruction and/or to the greenhouse effect have been carried out at five globally distributed sites for several years. The program, which began in 1978, is divided into three parts associated with three changes in instrumentation: the Atmospheric Lifetime Experiment (ALE), which used Hewlett Packard HP5840 gas chromatographs; the Global Atmospheric Gases Experiment (GAGE), which used HP5880 gas chromatographs; and the present Advanced GAGE (AGAGE). AGAGE uses two types of instruments: a gas chromatograph with multiple detectors (GC-MD), and a gas chromatograph with mass spectrometric analysis (GC-MS). Beginning in January 2004, an improved cryogenic preconcentration system (Medusa) replaced the absorption-desorption module in the GC-MS systems at Mace Head and Cape Grim; this provided improved capability to measure a broader range of volatile perfluorocarbons with high global warming potentials. The Medusa GC-MS systems were subsequently used at other AGAGE stations (Trinidad Head, Barbados, American Samoa, Zeppelin, Jungfraujoch, and Goan) after the initial setup at Mace Head and Cape Grim. More information may be found on the AGAGE home page: https://agage.mit.edu/instruments.Data from the AGAGE and affiliated stations (total of 10 sites) between August 1993 and June 2022 are provided in “Agage_gcmd_gcms_data_2023_07_24.tar.gz” (compressed tar file). The metadata file has information on each station and currently released species. The standard scales used in archived species are listed in "AGAGE_scale_2023_v1.pdf". Additional information can be found on the AGAGE website (https://agage.mit.edu).

54 ENVIRONMENTAL SCIENCES↗

The dataset of in-situ measurements of chemically and radiatively important atmospheric gases from the Advanced Global Atmospheric Gas Experiment (AGAGE) and affiliated stations (2023R2)

In the ALE/GAGE/AGAGE global network program, continuous high frequency gas chromatographic measurements of four biogenic/anthropogenic gases (methane, CH4; nitrous oxide, N2O; hydrogen, H2; and carbon monoxide, CO) and several anthropogenic gases that contribute to stratospheric ozone destruction and/or to the greenhouse effect have been carried out at five globally distributed sites for several years. The program, which began in 1978, is divided into three parts associated with three changes in instrumentation: the Atmospheric Lifetime Experiment (ALE), which used Hewlett Packard HP5840 gas chromatographs; the Global Atmospheric Gases Experiment (GAGE), which used HP5880 gas chromatographs; and the present Advanced GAGE (AGAGE). AGAGE uses two types of instruments: a gas chromatograph with multiple detectors (GC-MD), and a gas chromatograph with mass spectrometric analysis (GC-MS). Beginning in January 2004, an improved cryogenic preconcentration system (Medusa) replaced the absorption-desorption module in the GC-MS systems at Mace Head and Cape Grim; this provided improved capability to measure a broader range of volatile perfluorocarbons with high global warming potentials. The Medusa GC-MS systems were subsequently used at other AGAGE stations (Trinidad Head, Barbados, American Samoa, Zeppelin, Jungfraujoch, and Goan) after the initial setup at Mace Head and Cape Grim. More information may be found on the AGAGE home page: https://agage.mit.edu/instruments.Data from the AGAGE and affiliated stations (total of 10 sites) between August 1993 and December 2022 are provided in “Agage_gcmd_gcms_data_2023_11_15.tar.gz” (compressed tar file). The metadata file has information on each station and currently released species. The standard scales used in archived species are listed in "AGAGE_scale_2023_v2.pdf". Additional information can be found on the AGAGE website (https://agage.mit.edu).

54 ENVIRONMENTAL SCIENCES↗

The dataset of in-situ measurements of chemically and radiatively important atmospheric gases from the Advanced Global Atmospheric Gas Experiment (AGAGE) and affiliated stations (2024R1)

In the ALE/GAGE/AGAGE global network program, continuous high frequency gas chromatographic measurements of four biogenic/anthropogenic gases (methane, CH4; nitrous oxide, N2O; hydrogen, H2; and carbon monoxide, CO) and several anthropogenic gases that contribute to stratospheric ozone destruction and/or to the greenhouse effect have been carried out at five globally distributed sites for several years. The program, which began in 1978, is divided into three parts associated with three changes in instrumentation: the Atmospheric Lifetime Experiment (ALE), which used Hewlett Packard HP5840 gas chromatographs; the Global Atmospheric Gases Experiment (GAGE), which used HP5880 gas chromatographs; and the present Advanced GAGE (AGAGE). AGAGE uses two types of instruments: a gas chromatograph with multiple detectors (GC-MD), and a gas chromatograph with mass spectrometric analysis (GC-MS). Beginning in January 2004, an improved cryogenic preconcentration system (Medusa) replaced the absorption-desorption module in the GC-MS systems at Mace Head and Cape Grim; this provided improved capability to measure a broader range of volatile perfluorocarbons with high global warming potentials. The Medusa GC-MS systems were subsequently used at other AGAGE stations (Trinidad Head, Barbados, American Samoa, Zeppelin, Jungfraujoch, and Goan) after the initial setup at Mace Head and Cape Grim. More information may be found on the AGAGE home page: https://agage.mit.edu/instruments.Data from the AGAGE and affiliated stations (total of 10 sites) between August 1993 and June 2023 are provided in “Agage_gcmd_gcms_data_2024_07_11.tar.gz” (compressed tar file). The metadata file has information on each station and currently released species. The standard scales used in archived species are listed in "AGAGE_scale_2024_v1.pdf". Additional information can be found on the AGAGE website (https://agage.mit.edu).Update: Dec. 4, 20241. The Cape Grim H2_PDD data are updated in this release ((H2_PDD values in previous release are wrong due to coding error). All other data in this release are the same as previous version ("Agage_gcmd_gcms.data.2024_07_11.tar.gz")2. The latest data are saved in "Agage_gcmd_gcms.data.2024_12_04.tar.gz"

54 ENVIRONMENTAL SCIENCES↗

Measuring Orbit Responses with Oscillating Trajectories in the Fermilab Linac

Recording changes in beam transverse positions re-ported by Beam Position Monitors (BPMs) in response to a beam deflection by an upstream dipole corrector (orbit response) is a powerful tool for analysis of accelerator optics and assisting with machine tuning. In the Fermilab Linac, orbit responses are recorded by oscillating the currents of up to 19 correctors, providing faster, drift-resistant measurements through frequency-domain analysis. This report describes the technique, including error estimations and consistency checks and shows an example of the measurements.

Shemyakin, Alexander V. [Fermilab] (ORCID:00000001↗

Sequence Impedance Measurement of Utility-Scale Wind Turbines and Inverters – Reference Frame, Frequency Coupling, and MIMO/SISO Forms

Sequence impedance responses with or without considering frequency coupling in both MIMO and SISO forms are increasingly used for the stability analysis of three-phase power electronic systems; however, many aspects of sequence impedance measurement are not fully explored. It is not clear if the sequence impedance has a reference frame similar to the dq impedance. If so, the role of the grid voltage angle estimation in aligning the sequence impedance reference frame has not been discussed. Additionally, existing methods for measuring the sequence impedance with frequency coupling are complicated, are not feasible for large wind turbines and inverters, and provide the sequence impedance responses in only either MIMO or SISO form. This paper presents a sequence impedance measurement method that considers the frequency coupling, performs reference frame alignment, demonstrates the impact of the grid voltage angle estimation, and obtains the sequence impedance response in both MIMO and SISO forms. This paper demonstrates the proposed method and practical problems associated with the sequence impedance measurement of utility-scale wind turbines and inverters on a 1.9-MW Type III wind turbine and a 2.2-MVA inverter using an impedance measurement system built around a 7-MW/13.8-kV grid simulator and a 5-MW dynamometer.

17 WIND ENERGY↗

Simulations of wavelength-multiplexed holography for single-shot spatiotemporal characterization of NIF’s advanced radiographic capability (ARC) laser

We simulate the use of a newly developed single-shot wavelength-multiplexed holography-based diagnostic, STRIPED FISH, to fully characterize the as-delivered laser pulses of the National Ignition Facility’s Advanced Radiographic Capability (NIF-ARC) laser. To that end, we have performed simulations of the NIF-ARC pulse incorporating (a) a time-integrated spatial-profile measurement and a complete temporal-intensity-and-phase measurement using a frequency resolved optical gating, but without any spatiotemporal pulse characterizations, and (b) simulated first-order spatiotemporal distortions, which could be measured on a single shot if a STRIPED FISH device were deployed.

47 OTHER INSTRUMENTATION↗

Triple-frequency radar retrieval of microphysical properties of snow

Abstract. An algorithm based on triple-frequency (X, Ka, W) radar measurements that retrieves the size, water content and degree of riming of ice clouds is presented. This study exploits the potential of multi-frequency radar measurements to provide information on bulk snow density that should underpin better estimates of the snow characteristic size and content within the radar volume. The algorithm is based on Bayes' rule with riming parameterised by the “fill-in” model. The radar reflectivities are simulated with a range of scattering models corresponding to realistic snowflake shapes. The algorithm is tested on multi-frequency radar data collected during the ESA-funded Radar Snow Experiment For Future Precipitation Mission. During this campaign, in situ microphysical probes were mounted on the same aeroplane as the radars. This nearly perfectly co-located dataset of the remote and in situ measurements gives an opportunity to derive a combined multi-instrument estimate of snow microphysical properties that is used for a rigorous validation of the radar retrieval. Results suggest that the triple-frequency retrieval performs well in estimating ice water content (IWC) and mean mass-weighted diameters obtaining root-mean-square errors of 0.13 and 0.15, respectively, for log 10IWC and log 10Dm. The retrieval of the degree of riming is more challenging, and only the algorithm that uses Doppler information obtains results that are highly correlated with the in situ data.

54 ENVIRONMENTAL SCIENCES↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-Induced Spectral Diffusion of T Centers in Silicon Nanophotonic Devices

Color centers in silicon are emerging as spin-photon interfaces operating at telecommunication wavelengths. The nanophotonic device integration of silicon color centers via ion implantation leads to significant optical-linewidth broadening, which makes indistinguishable photon generation challenging. Here, we study the optical spectral diffusion of T centers in a silicon photonic crystal cavity. We investigate the linewidth-broadening timescales and origins by measuring the temporal correlations of the resonance frequency under different conditions. Spectral hole-burning measurements reveal no spectral broadening at short timescales from 102 ns to 725 ns. We probe broadening at longer timescales using a check pulse to herald the T-center frequency and a probe pulse to measure the frequency after a wait time. The optical resonance frequency is stable up to 3 ms in the dark. Laser pulses below the silicon band gap applied during the wait time lead to linewidth broadening. Our observations establish laser-induced processes as the dominant spectral-diffusion mechanism for T centers in devices and inform materials and feedback strategies for indistinguishable photon generation.

Zhang, Xueyue↗

Precise $\textit{Q}$-value measurements of 112,113 Ag and 115 Cd with the Canadian Penning trap for evaluation of potential ultralow $\textit{Q}$-value $\textit{β}$ decays

Background: An ultralow $\textit{Q}$-value $\textit{β}$ decay can occur from a parent nuclide to an excited nuclear state in the daughter such that $Q_{\text{UL}}$ 1 keV. These decay processes are of interest for nuclear $\textit{β}$-decay theory and as potential candidates in neutrino mass determination experiments. To date, only one ultralow $\textit{Q}$-value $\textit{β}$ decay has been observed—that of 115 In with $Q_β$ = 147(10) eV. A number of other potential candidates exist, but improved mass measurements are necessary to determine if these decay channels are energetically allowed and, in fact, ultralow. Purpose: To perform precise $\textit{β}$-decay $\textit{Q}$-value measurements of 112,113 Ag and 115 Cd and to use them in combination with nuclear energy level data for the daughter isotopes 112,113 Cd and 115 In to determine if the potential ultralow $\textit{Q}$-value $\textit{β}$-decay branches of 112,113 Ag and 115 Cd are energetically allowed and 1 keV. Method: The Canadian Penning Trap at Argonne National Laboratory was used to measure the cyclotron frequency ratios of singly charged 112,113 Ag and 115 Cd ions with respect to their daughters 112,113 Cd and 115 In. From these measurements, the ground-state to ground-state $\textit{β}$-decay $\textit{Q}$ values were obtained. Results: The 112 Ag → 112 Cd, 113 Ag → 113 Cd, and 115 Cd → 115 In $\textit{β}$-decay $\textit{Q}$ values were measured to be $Q_β$( 112 Ag) = 3990.16(22) keV, $Q_β$( 113 Ag) = 2085.7(4.6) keV, and $Q_β$( 115 Cd) = 1451.36(34) keV. These results were compared to energies of excited states in 112 Cd at 3997.75(14) keV, 113 Cd at 2015.6(2.5) and 2080(10) keV, and 115 In at 1448.787(9) keV, resulting in precise $Q_{\text{UL}}$ values for the potential decay channels of –7.59(26) keV, 6(11) keV, and 2.57(34) keV, respectively. Conclusion: The potential ultralow $\textit{Q}$-value decays of 112 Ag and 115 Cd have been ruled out. 113 Ag is still a possible candidate until a more precise measurement of the 2080(10) keV, 1/2+ state of 113 Cd is available. In the course of this work we have found the ground state mass of 113 Ag reported in the 2020 Atomic Mass Evaluation [Wang et al., Chin. Phys. C 45, 030003 (2021)] to be lower than our measurement by 69(17) keV (a 4σ discrepancy).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗