Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fourier transforms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Two-dimensional Fourier transform electronic spectroscopy at a conical intersection

We report measurement and modeling of two-dimensional (2D) electronic spectra of a silicon naphthalocyanine (SiNc) in benzonitrile, a system for which the polarization anisotropy reveals passage through a square-symmetric Jahn-Teller conical intersection in ∼100 fs [D. A. Farrow, W. Qian, E. R. Smith, A. A. Ferro, and D. M. Jonas, J. Chem. Phys. 128, 144510 (2008)]. The measured 2D Fourier transform (FT) spectra indicate loss of electronic coherence on a similar timescale. The 2D spectra arising from femtosecond vibronic dynamics through the conical funnel are modeled by full non-adiabatic treatment of the coupled electronic and vibrational dynamics for a pair of un-damped Jahn-Teller active vibrations responsible for both electronic decoherence and population transfer. Additional damped Jahn-Teller active modes that can cause only decoherence or population transfer are treated with analytical response functions that can be incorporated into the numerical non-adiabatic calculation by exploiting symmetry assignment of degenerate vibronic eigenstates to one of two electronic states. Franck-Condon active totally symmetric modes are incorporated analytically. The calculations reveal that these conical intersection dynamics alone are incapable of destroying the coherence of the initially prepared wavepacket on the experimentally observed timescale and predict an unobserved recurrence in the photon echo slice at ∼200 fs. Agreement with the experimental two-dimensional electronic spectra necessitates a role for totally symmetric vibrational dynamics in causing the echo slice to decay on a ∼100 fs timescale. This extended model also reproduces the ∼100 fs ultrafast electronic anisotropy decay in SiNc when an “asymmetric solvation mode” with a small stabilization energy of ∼2 cm{sup −1} is included. Although calculations show that inhomogeneities in the energy gap between excited states can broaden the anti-diagonal 2D lineshape, the anti-diagonal width is dominated by totally symmetric vibrational motions in SiNc. For this shallow conical intersection, the non-adiabatic dynamics destroy electronic coherence more slowly than they destroy electronic alignment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spatio-temporal Fourier Transformer for Long-term Dynamics Prediction (StFT) v1.0

We propose a novel machine learning model spatio-temporal Fourier transformer (StFT) to emulate long-term dynamics of multi-scale and multi-physics systems. Our method StFT overcomes the limitations of rapid error accumulation, particularly in long-term forecasting of systems characterized by complex and coupled dynamics. StFT achieves outstanding accuracy and computational efficiency by effectively capturing multi-scale interactions, and quantify the uncertainties inherent in the predictions. Our model leverages a structured hierarchy of StFT blocks, and explicitly captures dynamics across both macro- and micro- spatial scales. Evaluations conducted on three benchmark datasets (plasma, fluid, and atmospheric dynamics) demonstrate the advantages of our approach over state-of-the-art ML methods.

Bai, Zhe [Lawrence Berkeley National Laboratory (L↗

Double passing the Kitt Peak 1-m Fourier transform spectrometer

Attention is given to a simple technique for performing the conversion of the Kitt Peak 1-m Fourier transform spectrometer's dual input/output optical configuration to a double pass configuration that improves spectral resolution by a factor of 2. The modification is made by placing a flat mirror in the output beam from each cat's eye, retroreflecting the beams back through the cat's eyes to the first beam splitter. A single detector is placed at the second input port, which then becomes the instrument's output.

Jennings, D. E.↗

Applications of asynoptic space - Time Fourier transform methods to scanning satellite measurements

A method proposed by Salby (1982) for computing the zonal space-time Fourier transform of asynoptically acquired satellite data is discussed. The method and its relationship to other techniques are briefly described, and possible problems in applying it to real data are outlined. Examples of results obtained using this technique are given which demonstrate its sensitivity to small-amplitude signals. A number of waves are found which have previously been observed as well as two not heretofore reported. A possible extension of the method which could increase temporal and longitudinal resolution is described.

Lait, Leslie R.↗

Experimental geometry for simultaneous beam characterization and sample imaging allowing for pink beam Fourier transform holography or coherent diffractive imaging

One consequence of the self-amplified stimulated emission process used to generate x rays in free electron lasers (FELs) is the intrinsic shot-to-shot variance in the wavelength and temporal coherence. In order to optimize the results from diffractive imaging experiments at FEL sources, it will be advantageous to acquire a means of collecting coherence and spectral information simultaneously with the diffraction pattern from the sample we wish to study. We present a holographic mask geometry, including a grating structure, which can be used to extract both temporal and spatial coherence information alongside the sample scatter from each individual FEL shot and also allows for the real space reconstruction of the sample using either Fourier transform holography or iterative phase retrieval.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High Mass Analysis with a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer: From Inorganic Salt Clusters to Antibody Conjugates and Beyond

Analysis of proteins and complexes under native mass spectrometric (MS) and solution conditions was typically performed using time-of-flight (ToF) analyzers, due to their routine high m/z transmission and detection capabilities. However, over recent years, the ability of Orbitrap-based mass spectrometers to transmit and detect a range of high molecular weight species is well documented. Herein, we describe how a 15 Tesla Fourier transform ion cyclotron resonance mass spectrometer (15 T FT-ICR MS) is more than capable of analyzing a wide range of ions in the high m/z scale (>5000), in both positive and negative instrument polarities, ranging from the inorganic cesium iodide salt clusters; a humanized IgG1k monoclonal antibody (mAb; 148.2 kDa); an IgG1-mertansine drug conjugate (148.5 kDa, drug-to-antibody ratio; DAR 2.26); an IgG1-siRNA conjugate (159.1 kDa; ribonucleic acid to antibody ratio; RAR 1); the membrane protein aquaporin-Z (97.2 kDa) liberated from a C8E4 detergent micelle; the empty MSP1D1-nanodisc (142.5 kDa) and the tetradecameric chaperone protein complex GroEL (806.2 kDa; GroEL dimer at 1.6 MDa). We also investigate different regions of the FT-ICR MS that impact ion transmission and desolvation. Finally, we demonstrate how the transmission of these species and resultant spectra are highly consistent with those previously generated on both quadrupole-ToF (Q-ToF) and Orbitrap instrumentation. This article serves as an impactful example of how FT-ICR mass analyzers are competitive to Q-ToFs and Orbitraps for high mass detection at high m/z.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Grazing incidence angle based sensing approach integrated with fiber-optic Fourier transform infrared (FO-FTIR) spectroscopy for remote and label-free detection of medical device contaminations

Contamination of medical devices has become a critical and prevalent public health safety concern since medical devices are being increasingly used in clinical practices for diagnostics, therapeutics and medical implants. The development of effective sensing methods for real-time detection of pathogenic contamination is needed to prevent and reduce the spread of infections to patients and the healthcare community. In this study, a hollow-core fiber-optic Fourier transform infrared spectroscopy methodology employing a grazing incidence angle based sensing approach (FO-FTIR-GIA) was developed for detection of various biochemical contaminants on medical device surfaces. We demonstrated the sensitivity of FO-FTIR-GIA sensing approach for non-contact and label-free detection of contaminants such as lipopolysaccharide from various surface materials relevant to medical device. The proposed sensing system can detect at a minimum loading concentration of approximately 0.7 μg/cm{sup 2}. The FO-FTIR-GIA has the potential for the detection of unwanted pathogen in real time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-resolved Fourier-transform infrared emission spectroscopy of Ag in the (1300-3600)-cm{sup -1} region: Transitions involving f and g states and oscillator strengths

We report on a study of the emission spectra of Ag vapor in a vacuum (10{sup -2} Torr) formed in ablation of an Ag metal target by a high-repetition rate (1.0 kHz) pulsed nanosecond ArF laser ({lambda}=193 nm, output energy of 15 mJ). The time-resolved infrared emission spectrum of Ag was recorded in the 1300- to 3600-cm{sup -1} spectral region using the Fourier transform infrared spectroscopy technique with a resolution of 0.02 cm{sup -1}. The time profiles of the measured lines have maxima at 5-6 {mu}s after a laser shot and display nonexponential decay with a decay time of 3-7 {mu}s. The lines reported here are given with an uncertainty of 0.0005-0.016 cm{sup -1}. The line classification is performed using relative line strengths expressed in terms of transition dipole matrix elements calculated with the help of the Fues model potential; these calculations show agreement with the large experimental and calculated data sets available in the literature. In addition to these data we also calculate transition probabilities and line and oscillator strengths for a number of transitions in the 1300- to 5000-cm{sup -1} range between (4d{sup 10})nl{sub j} states of Ag.

74 ATOMIC AND MOLECULAR PHYSICS↗

On the Use of Fourier Transform Infrared (FT-IR) Spectroscopy and Synthetic Calibration Spectra to Quantify Gas Concentrations in a Fischer-Tropsch Catalyst System

One possible origin of prebiotic organic material is that these compounds were formed via Fischer-Tropsch-type (FTT) reactions of carbon monoxide and hydrogen on silicate and oxide grains in the warm, inner-solar nebula. To investigate this possibility, an experimental system has been built in which the catalytic efficiency of different grain-analog materials can be tested. During such runs, the gas phase above these grain analogs is sampled using Fourier transform infrared (FT-IR) spectroscopy. To provide quantitative estimates of the concentration of these gases, a technique in which high-resolution spectra of the gases are calculated using the high-resolution transmission molecular absorption (HITRAN) database is used. Next, these spectra are processed via a method that mimics the processes giving rise to the instrumental line shape of the FT-IR spectrometer, including apodization, self-apodization, and broadening due to the finite resolution. The result is a very close match between the measured and computed spectra. This technique was tested using four major gases found in the FTT reactions: carbon monoxide, methane, carbon dioxide, and water. For the ranges typical of the FTT reactions, the carbon monoxide results were found to be accurate to within 5% and the remaining gases accurate to within 10%. These spectra can then be used to generate synthetic calibration data, allowing the rapid computation of the gas concentrations in the FTT experiments.

Infrared Spectroscopy↗

Exploring Biosignatures Associated with Thenardite by Geomatrix-Assisted Laser Desorption/Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry (GALDI-FTICR-MS)

Geomatrix-assisted laser desorption/ionization (GALDI) in conjunction with a Fourier transform ion cyclotron resonance mass spectrometer (FTICR-MS) has been employed to determine how effectively bio/organic molecules associated with the mineral thenardite (Na2SO4) can be detected. GALDI is based on the ability of the mineral host to assist desorption and ionization of bio/organic molecules without additional sample preparation. When glycine was mixed with thenardite, glycine was deprotonated to produce C2H4NO-2 at m/z 74.025. The combination of stearic acid with thenardite produced a complex cluster ion at m/z 390.258 in the negative mode, which was assigned a composition ofC18H39O7Na-. Anatural sample of thenardite from Searles Lake in California also produced a peak at m/z 390.260. The bio/organic signatures in both the laboratory-based and natural samples were heterogeneously dispersed as revealed by chemical imaging. The detection limits for the stearic acid and thenardite combination were estimated to be 3 parts per trillion or~7 zeptomoles (10-21) per laser spot. Attempts to improve the signal-to-noise ratio by co-adding FTICR-MS data predetermined to contain the biosignatures of interest revealed problems due to a lack of phase coherence between data sets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimal Control for Fourier Transform on Qudits

In this work, we develop a protocol to find the optimal control pulse for implementing the Quantum Fourier Transform (QFT) on qudit-based hardware. We focus on two types of controls: (1) qubit-qudit dispersive coupling with qubit and qudit drives, and (2) qubit-qudit system with tunable coupling and qubit drive. We observe that for both systems, the minimum gate time grows linearly as a function of the size of the logical space. We find that the latter system supports faster pulses, requiring 45% shorter pulse time.

Ha, Triet↗

Observation of Potential Contaminants in Processed Biomass Using Fourier Transform Infrared Spectroscopy

With rapidly increased interests in biomass, diverse chemical and biological processes have been applied for biomass utilization. Fourier transform infrared (FTIR) analysis has been used for characterizing different types of biomass and their products, including natural and processed biomass. During biomass treatments, some solvents and/or catalysts can be retained and contaminate biomass. In addition, contaminants can be generated by the decomposition of biomass components. Herein, we report FTIR analyses of a series of contaminants, such as various solvents, chemicals, enzymes, and possibly formed degradation by-products in the biomass conversion process along with poplar biomass. This information helps to prevent misunderstanding the FTIR analysis results of the processed biomass.

09 BIOMASS FUELS↗

Fourier transform spectrometry for fiber-optic sensor systems

An integrated-optic Mach-Zehnder interferometer is used as a Fourier transform spectrometer to analyze the input and output spectra of a temperature-sensing thin-film etalon. This type of spectrometer has an advantage over conventional grating spectrometers because it is better suited for use with time-division-multiplexed sensor networks. In addition, this spectrometer has the potential for low cost due to its use of a component that could be manufactured in large quantities for the optical communications industry.

Beheim, Glenn↗

A comprehensive review of diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) techniques in protonic ceramic cells (PCCs): Current status and future perspective

Protonic ceramic cells (PCCs) have emerged as a promising technology for power generation, energy storage, and value-added chemical synthesis, offering benefits such as fuel flexibility, low emissions, and efficient operation at intermediate temperatures (300–600 ​°C). Recently, significant breakthroughs in materials and manufacturing methods have markedly enhanced the performance of PCCs. However, establishing a fundamental understanding of their electrocatalytic reactions has gained less attention. As a fast and cost-effective method for physicochemical fingerprinting, diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) has proven to be a surface-sensitive analytical tool for structural and functional studies. This review critically examines the most up-to-date applications of DRIFTS for characterizing key components of PCCs, including oxygen electrodes, protonic electrolytes, and hydrogen electrodes for different applications, with a focus on revealing hydration properties and catalytic reactions, and guiding rational material design. The challenges for advancing DRIFTS, including quantitative capabilities and operando applications for PCC investigations, are highlighted and strategies to tackle these challenges are discussed. Ultimately, this review underscores the critical role of DRIFTS in accelerating the development of high-performance and durable PCCs for next-generation energy solutions, offering methodologies and insights broadly applicable to a wide range of electrochemical energy conversion and storage technologies.

Diffuse Reflectance Infrared Fourier Transform Spe↗

Characterization of Sequentially Extracted Soil Organic Matter by Electrospray Ionization and Atmospheric Pressure Photoionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry

Soil organic matter (SOM) is a complex mixture of small molecules and biopolymers that are active in various biogeochemical processes. However, the chemical diversity of biopolymer-derived SOM remains poorly explored. Identifying this diversity is important because global environmental changes may well alter SOM chemistry, as field experiments are beginning to show. Here, organic solvent-extractable (DcMe-SOM), base-hydrolyzable (KOH Hy -SOM), and CuO-oxidizable (CuO Ox -SOM) SOM fractions from a forest with a long-term nitrogen addition experiment were sequentially extracted and characterized by Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) coupled with negative-ion electrospray ionization (ESI) or atmospheric pressure photoionization (APPI). From DcMe-SOM to CuO Ox -SOM, the total number of assigned formulas, average O/C ratio, aromaticity, and unsaturation degree of SOM continuously increased, while the average m/z and H/C ratio decreased. Moreover, the dominant chemical category shifted from lipid-like components to phytochemical- and protein-like components. Complementary to ESI, APPI effectively facilitated detection of additional compounds with low polarity. With long-term nitrogen addition, the average m/z, unsaturation degree, aromaticity, and oxidation state of SOM increased, and more aromatic nitrogen-containing formulas were detected in CuOOx-SOM. Our study demonstrates that chronic nitrogen deposition in forests alters both the small molecules and biopolymers of SOM fundamentally.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coolant Pump Predictive Data Analytics from Signatures Generated by the Recursive Short Time Fast Fourier Transform

Although a nuclear reactor is a hostile environment for sensors and signal transmissions, the reactor core is amenable to acoustic communication. An acoustic measurement infrastructure installed at the Advanced Test Reactor (ATR) nozzle trench area records acoustic signals that can capture reactor operating states. The distinct states produce unique signatures that can be identified and tracked using data processing and data analytics. The infrastructure relies on acoustic transmission through ATR in-pile structural components, piping, and coolant that transmit acoustically modified signals generated by the coolant pumps. This paper will discuss results from using the Recursive Short Time Fast Fourier Transform (RSTFFT) technique used to process acoustic signals and provide signatures that are identified and monitored by analytics. The RSTFFT is applied to ATR data to understand the vibration levels and signatures for different operating regimes as displayed by the spectrogram. The combination of coolant pumps for normal and high-power operation generate unique signatures. These acoustic signatures are used to develop machine learning approaches to automatically classify operating regimes. Two machine-learning models, Support Vector Machines and Linear Discriminant Analysis, were developed to classify two event classes. Class 1 is a normal steady-state operation, and Class 2 is any event that is due to start up, shut down, or other actions. Both types of machine learning models had over a 96% prediction accuracy for the two classes. These results lay the foundation for predictive analytic frameworks that can be leveraged by ATR to optimize operations and maintenance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ARM West Antarctic Radiation Experiment (AWARE) Fourier Transform Infrared Filter Sampling Systems Field Campaign Report

West Antarctica is one of the most rapidly warming regions in the world (Bromwich et al. 2013; Steig et al. 2009) and the warming can directly cause sea level rise (King et al. 2012). In situ measurements are needed to examine and quantify the meteorological conditions in order to precisely understand the effect of warm air and clouds on the West Antarctic Ice Shelf (WAIS). The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) West Antarctic Radiation Experiment (AWARE) is designed to collect measurements with advanced cloud and aerosol instrumentation at West Antarctica. The Fourier Transform Infrared (FTIR) filter sampling systems were deployed as part of the ARM West Antarctic Radiation Experiment (AWARE) campaign to measure organic aerosol characteristics at McMurdo Station. As a coastal station at the southern end of Ross Island, McMurdo Station has a meteorological relationship with the WAIS via circulation patterns in the Ross and Amundsen Seas. Thirteen months of continuous observations of aerosol particle composition extended from December 2016 to January 2017. Filter samples were collected at McMurdo on pre-scanned Teflon filters (Teflon, Pall Inc., 37mm diameter) behind PM1 sharp-cut cyclones (SCC2.229 PM1, BGI Inc). Samples were collected each week with approximately 50-90 m3 air filtered per sample. Samples were frozen and transported below 0°C to the Scripps laboratory for FTIR spectroscopy analysis. A Bruker Tensor 27 FTIR spectrometer with a deuterated triglycine sulfate (DTGS) detector (Bruker, Waltham, MA) was used to scan the filters both before and after sampling. An automated algorithm (Takahama et al. 2013) was applied to quantify the mass of the organic functional groups. Four groups (alkane, amine, alcohol, and carboxylic acid) had absorption peaks above the limits of quantification, and the sum of the mass of the four functional groups is the quantified organic mass (OM). Absorption peaks for other groups (organosulfate, organonitrate, aromatic, and alkene group) were identified and fit but they were below the limit of quantification for more than 90% of the samples and are excluded. Similar FTIR measurements has been conducted in dozens of field campaigns around the world, including arctic regions (Russell et al. 2011). Local particle emissions from airports, diesel generators, and local transportation affected all aerosol measurements at various times during this project. The ARM Aerosol Measurement Science Group is aware of the issue and is working to develop algorithms to flag the data. This influence is evident in the FTIR measurements as it is associated with specific chemical signatures. DOE and the National Science Foundation, which manages the U.S. Antarctic Program, supported this collaboration for AWARE.

ARM West Antarctic Radiation Experiment, Fourier T↗

Fourier-transform infrared spectroscopy for rapid screening and live-cell monitoring: application to nanotoxicology

A significant challenge to realize the full potential of nanotechnology for therapeutic and diagnostic applications is to understand and evaluate how live-cells interact with an external stimulus, e.g., a nanosized particle (NSP), and the toxicity and broad risk associated with these stimuli. NSPs are increasingly used in medicine with largely undetermined hazards in complex cell dynamics and environments. It is difficult to capture the complexity and dynamics of these interactions by following an omics-based approach exclusively, which are expensive and time-consuming. Additionally, this approach needs destructive sampling methods. Live-cell attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectrometry is well suited to provide noninvasive approach to provide rapid screening of cellular responses to potentially toxic NSPs or any stimuli. Herein we review the technical basis of the approach, the instrument configuration and interface with the biological media, and various effects that impact the data, data analysis, and toxicity. Our preliminary results on live-cell monitoring show promise for rapid screening the NSPs.

nanosized particle, toxicity, in vitro, spectrosco↗