Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “forensics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

The electronic Raman scattering spectrum of PuO 2

Here the Raman spectrum of PuO 2 was measured up to 13,000 cm –1 with three different laser excitation wavelengths spanning the resonance (405 nm), near-resonance (457 nm), and preresonance (514 nm) energy range. Approximately 26 never-before-seen bands were observed between 3500 and 13,000 cm –1 . Given the very high energy of the Raman shifts of these bands and the relative insensitivity of their spectral position to the interrogating laser wavelength, they are believed to arise from an electronic origin. These bands are present in both freshly calcined and radiolytically aged PuO 2 , although a broad luminescence is observed in the aged material, which obscures many of the high frequency features. In situ laser annealing of the material attenuated this luminescence and allowed for clear observation of these never-before-seen spectral features. Discovery of these high-energy bands presents a new way of identifying PuO 2 for nuclear nonproliferation and forensics purposes.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Isotopic analysis of sub-nanogram neodymium loads using new ATONA™ amplifiers

The long-term gains of the ATONA™ amplifiers are shown to have less than 1 ppm variability. Repeat measurements of the JNdi-1 reference material demonstrate the ability of the ATONA™ amplification technology to make measurements of 143 Nd/ 144 Nd ratios with 23 ppm external reproducibility on 100-pg loads. The effect of increasing integration time on analytical reproducibility is also displayed as increasing integration time from 10 to 30s reduced the external measurement uncertainty from 37 to 23 ppm. These measurements represent an improvement of more than a factor of 3 in external measurement reproducibility relative to previously published 143 Nd/ 144 Nd measurements of 100-pg loads. Furthermore, this new technology will allow for the measurement of smaller samples for precise isotope ratios and open new avenues of research in the geological and nuclear forensic communities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Complete resolution across the neodymium/samarium isotopic envelope with a liquid sampling‐atmospheric pressure glow discharge — Orbitrap mass spectrometer

Rationale Nd and Sm isotope ratios play an important role in geological dating and as nuclear forensic signatures; however, the overlap of the respective 144, 148, 150 Nd/Sm isobars requires prior separations to be performed before analysis on typical MS platforms. The work presented here overcomes these isobaric interferences using ultrahigh‐mass resolution to alleviate interference without prior chemical separations. Methods A liquid sampling‐atmospheric pressure glow discharge ion source was coupled to a standard, QExactive Focus Orbitrap mass spectrometer, providing a mass resolution of ~80 k. A Spectroswiss FTMS booster X2 data acquisition package was used to collect extended transients, providing much higher mass resolution; ~230 k and ~600 k are employed here for Nd and Sm isotopes. Results While the standard Orbitrap resolution is far greater than typical “atomic” MS platforms, it was insufficient to alleviate all isobars. The use of a resolution of ~230 k resulted in baseline separation across the entire isotopic envelope for both Nd and Sm. Isotope ratios obtained from Nd:Sm mixtures using high‐resolution were equivalent to those found for individual‐element solutions, while isotope ratios obtained at a resolution of ~80 k (standard for the OEM data system) showed large deviations. Conclusions Use of ultrahigh‐resolution is an attractive alternative to extensive chemical separations to alleviate severe isobaric interferences. Sufficient mass resolution greatly reduces/eliminates the need for sample manipulations (separations) before analysis while reducing costs and total analysis times.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Prospects for Surrogate Neutron Capture Measurements with Radioactive Ion Beams and GODDESS

Neutron capture reactions are responsible for the synthesis of almost all of the elements heavier than iron through the slow s-process, that proceeds close to the line of stability, and the rapid r-process, with very neutron-rich waiting points. Uncertainties in (n,γ) rates in neutron rich nuclei, especially near closed neu- tron shells, can have significant impact [1] on the predictions of final abundances for different astrophysical scenarios for the r process. Understanding (n,γ) rates on neutron-rich fission fragments is also important for nuclear forensics and stockpile stewardship science. Ratkiewicz et al. [2 and references therein] has recently demonstrated that the (d,pγ) reaction is a valid surrogate for (n,γ), where the formation of the compound nucleus from the breakup of the deuteron has been calculated in a reaction model and the subsequent measured gamma-decay probabilities are reproduced with standard level density and strength functions in a Bayesian approach. In parallel to the surrogate validation efforts, we have demonstrated that the (d,pγ) reaction can be measured in inverse kinematics with Gammasphere ORRUBA: Dual Detectors for Experimental Structure Studies (GODDESS) [3] where the Gammasphere array of Compton-suppressed HPGe detectors is coupled to the Oak Ridge Rutgers University Barrel Array of position-sensitive silicon strip detectors. During the commissioning campaign we measured the (d,pγ) reaction with 134 Xe and 95 Mo beams, the latter to demonstrate the surrogate method in inverse kinematics. The present talk will present preliminary results from this campaign including γ-decay probabilities and prospects for surrogate (n,γ) measurements with 143 Ba fission-fragment beams.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Column separation of tetravalent cerium fission products from trivalent rare earth radio-isotopes

Rapid and efficient isolation of individual rare earth element (REE) radioisotopes from complex mixtures is necessary to support the fields of nuclear forensics, medical isotope production and nuclear physics measurements. The separations must be robust and generate sufficiently high purity samples for subsequent radiological analysis. Current methodologies utilize a laborious two step Ce(IV)-iodate precipitation followed by Ce(IV)-nitrate di-(2-ethylhexyl)phosphoric acid/n-heptane extraction. This work reports an alternative method to isolate Ce fission product isotopes equilibrated with milligrams of cold carrier, from the remaining REE’s using a Ce(IV)/LN-resin (Eichrom Technologies) based separation. Optimization of Ce(IV) loading, REE(III) elution volume and subsequent Ce(III) stripping step utilized 166m Ho tracer. Mixed fission product experiments provided a further test of this LN-resin method, with analysis of purified 141/144 Ce, 147 Nd and 91 Y. Overall, while decontamination factors were lower for the LN-resin method, (vs. the combined precipitation/extraction) the simplicity of the technique and the satisfactory fission product analysis results point to the efficacy of this method.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Collaborative Study for Certification of Trace Elements in Uranium Ore Concentrate CRMs UCLO-1, UCHI-1, and UPER-1

Trace impurity patterns are important nuclear forensic signatures in uranium ore concentrates (UOCs) and Certified Reference Materials (CRMs) are used to validate the analysis methods employed by end users. Herein, we discuss the certification campaign for three new UOC CRMs from the National Research Council Canada: UCLO-1 (https://doi.org/10.4224/crm.2020.uclo-1), UCHI-1 (https://doi.org/10.4224/crm.2020.uchi-1), and UPER-1 (https://doi.org/10.4224/crm.2020.uper-1). This study involved 15 laboratories from 10 countries, using sector-field and (triple) quadrupole inductively-coupled plasma mass spectrometry to analyze 64 trace element impurities. We discuss the importance of the acids used for sample digestion, difficulties analyzing in a high uranium matrix, and data combination and uncertainty evaluation for this large dataset.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Alpha/beta-gated gamma–gamma spectroscopy of mixed fission products for trace analysis

This experiment demonstrated that some hard-to-detect fission products can be quantified directly from mixed fission product samples using advanced radio-emission spectroscopy techniques. A gamma/gamma coincidence detector was combined with a custom liquid scintillation counter to evaluate the benefits of alpha and beta coincident and anti-coincident analysis of mixed fission product samples. Reduction factors in the minimum detectable activity (MDA) relative to traditional gamma counting were quantified for a set of radionuclides. For isotopes like 91Y, 144Ce, 147Nd, and 153Sm MDA reductions of factors of 1-2 were observed using optimized beta thresholds. Using beta anti-coincidence counting reductions of factors 3-5 were observed for isotopes like 89Sr, 95mNb, 115Cd, and 137Cs and factors of 5-7 for isotopes like 235U using alpha coincidence counting. The selectivity of gamma/gamma coincidence and reduction in backgrounds using beta gating were also demonstrated with 136Cs and 153Sm. The improvements observed in the detection sensitivity of fission products and actinides achieved by combining time-correlated radiation signatures is significant and of value to applications such as nuclear fission physics, environmental monitoring for nuclear waste, reactor accidental releases, and nuclear forensics.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Fission neutron activations of stainless steel and its corresponding elemental components

Characterizing neutron activation of stainless steel is a critical task for many applications, and yet little activation data is available for this alloy. To address the need, a series of neutron activation experiments have been performed using the Flattop critical assembly at the National Criticality Experiments Research Center. Several experimental conditions were probed for complete understanding of the neutron environment, including foil composition and position within the assembly. The experimental results reported here will aid in the production of stainless steel benchmarks for a range of nuclear data applications including those used in nuclear forensics analysis.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Noble gas constraints on spent fuel irradiation histories

Fission gas isotopic compositions are sensitive to a variety of reactor operating parameters that include the neutron flux, neutron fluence at different neutron energies, and operating temperature. Measurements of fission gas isotopic compositions thus have potential to constrain reactor simulations for nuclear forensics and safeguards applications. In this paper, we present Kr and Xe isotope measurements from a suite of samples obtained from locations that span the axial length a fuel pin with a well-characterized irradiation history and compare these data to spatially resolved reactor simulations. Here, we observed positive correlations between fluence sensitive isotopic ratios and burnup and between a flux sensitive ratio and power, although some discrepancies are observed between the measured data and model predictions. These differences may be due to simplifications in the model and/or inaccuracies in the cross sections. A much broader measurement to model comparison is required to better understand the discrepancies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison of microprecipitation methods for polonium source preparation for alpha spectrometry

Detection of radioactive isotopes of polonium is important for understanding natural processes, management and assessment of radioactive waste, and nuclear forensics applications. Further, the most common methods for preparation of polonium samples for alpha spectrometry are electrodeposition and spontaneous deposition which are time consuming. Here, we compare three approaches utilizing rapid microprecipitation from bismuth phosphate, copper sulfide, or tellurium alongside traditional spontaneous deposition methods. From these experiments, results show that copper sulfide microprecipitation recoveries are similar to spontaneous deposition on silver and less time consuming with an approximate five-fold decrease in preparation time, including in the presence of complex matrices like seawater.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Machine learning for fundamental spectroscopic and thermodynamic data of actinides and lanthanides

Accurately modeling optical spectra with absolute radiometric intensities is vital for nuclear forensics applications that depend on characterizing optical emissions from energetic nuclear phenomena. This requires precise knowledge of the individual atomic transition probabilities, known as Einstein A-coefficients, for each emission line. Obtaining these values theoretically or experimentally is often impractical due to the complex electronic structures and the number of transitions involved in atoms relevant to nuclear applications. In this study, we explore the use of machine learning to predict the Einstein A coefficients for atomic transitions. Seven models were evaluated that ranged from deep learning to decision tree algorithms, and found that gradient boosting performed best, specifically the Extreme Gradient Boosting (XGB) architecture, achieving a precision of 86% across transitions of 36 elements. Furthermore, the model was cross-validated using published transition probabilities reported in the literature and applied to estimate Pu plasma temperatures from a previous experiment conducted at Savannah River National Laboratory.

Atomic spectroscopy↗

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup↗

Evaluation of dried blood spot sampling for verification of exposure to chemical threat agents

Abstract Purpose Exposure to chemical threat agents (CTAs), including nerve agents, the vesicating agent sulfur mustard, and opioids, remains a significant threat to warfighter and civilian populations. Definitive analytical methods to verify exposure to CTAs require shipping refrigerated or frozen biomedical samples to reference laboratories for analysis. Logistical and financial burdens arise as the transport of biomedical samples is subject to strict restrictions and complex packaging, which, if done incorrectly, can lead to sample deterioration. The use of dried blood spot (DBS) sampling could provide operational improvements for collecting, storing, and shipping important forensic samples. Therefore, this effort focuses on developing DBS techniques with Mitra® 30-µL volumetric absorptive microsampling (VAMS®) devices for use in CTA exposure verification. Methods VAMS® devices were loaded and dried with human whole blood that was exposed to the metabolites pinacolyl methylphosphonic acid (PMPA), ethyl methylphosphonic acid (EMPA), 1,1’sulfonylbis[2-(methylsulfinyl)ethane] (SBMSE), norfentanyl, norcarfentanil, norsufentanil, and norlofentanil. Following extraction from the VAMS® devices, metabolites were detected using liquid chromatography-tandem mass spectrometry (LC–MS/MS). The methods were validated for performance by assessing sensitivity, precision, accuracy, and recovery. Results These methods were sensitive to 1 ng/mL for SBMSE, 0.5 ng/mL for PMPA, EMPA, and norfentanyl; 0.1 ng/mL for norlofentanil, and 0.05 ng/mL for norsufentanil and norcarfentanil. All methods met acceptable precision and accuracy criteria with favorable recovery. Conclusions These results demonstrated the utility of VAMS® in stabilizing human whole blood and show promise as an improved collection method for verification of exposure to various CTAs.

Toxicology↗

Understanding neutron capture processes in uranium deposits using combined U-Sm-Nd isotopic compositions

Valuable insights into the history and evolution of a geologic deposit can be found by investigating neutron capture reactions. Thermal neutron capture reactions occur within both the samarium (Sm) and the uranium (U) systems, where 149 Sm and 235 U can capture neutrons to become 150 Sm and 236 U, respectively. Although largely unexplored, paired measurements of 150 Sm and 236 U could be important for understanding neutron capture effects within uranium ore bodies, and such measurements are potentially useful in nuclear forensics for assessing a material's provenance or mineral exploration. In this work, we refined measurement procedures of Sm isotope compositions utilizing MC-ICPMS. While geologic reference materials were found to have indistinguishable Sm isotope compositions, we found significant isotope variations consistent with nuclear field shift among synthetic Sm standards. Here, this observation highlights that future high-precision Sm isotope investigations need to carefully evaluate synthetic standard(s) against geologic reference materials until an unfractionated and agreed-upon standard is identified. Here, we applied this method to a set of nine uranium ores from the South Australian Beverley North uranium deposits. Although 236 U excesses had been previously reported for these U ores, we found no measurable isotopic shifts in 149 Sm- 150 Sm at the current level of precision (±5 parts per million). One possible explanation for this disparity in the observed neutron capture signatures between U and Sm is that the source(s) of the U and Sm in these ores may be decoupled. This is consistent with the finding that these ores have variable 143 Nd/ 144 Nd, thus demonstrating that diverse sources were involved in the formation of the Beverley North deposits. Alternatively, this deposit may be too young (<50Ma) to have accumulated measurable neutron capture effects in Sm to be detected with the methods employed here.

Mineral exploration↗

Determination of the 161 Tb half-life

There is significant interest in the use of terbium radioisotopes for applications in cancer therapy and diagnosis. Of these, 161 Tb, a medium energy beta- and prolific auger emitter, is being investigated as a potential alternative to 177 Lu. The higher proportion of conversion electron and Auger electron emissions, and variety of low-energy gammas make 161 Tb an attractive targeted theranostic. As a product of nuclear fission, 161 Tb is also of importance to nuclear forensics. The current evaluated half-life of 6.89(2) d has a standard uncertainty that contributes significantly to the standard uncertainty of decay calculated activity determination. Furthermore, the accuracy of this evaluated half-life has been called into question by measurements reported recently at the Institute of Radiation Physics (IRP), Switzerland. In this work, the half-life of 161 Tb was measured at three independent laboratories located in the United Kingdom and United States of America for a total of five determinations using three independent measurement techniques. In conclusion, the half-life determined for 161 Tb of 6.9637(29) d confirms the observed 1 % relative increase observed by IRP, though the reported half-lives in this work and at IRP are significantly different (ζ-score = 3.1).

half-life↗

Use of Compton suppression gamma ray spectrometry to determine 239 Pu

We report 239 Pu has been characterized by gamma-ray spectroscopy for a level higher than the usual environmental ones typically needing alpha spectrometry, ICP-MS or TIMS. The higher activities typically have applications in reprocessing, safeguards verification, and nuclear forensics. For activities of hundreds of Bq/g, it is possible to use gamma ray spectrometry for 239 Pu characterization. A soil reference standard of 185 Bq/g (75 ng/g) was measured on a 79% efficient HPGe with a digital Compton suppression system. The ratios of the counting statistics for suppressed and unsuppressed uncertainties for various 239 Pu photopeaks were determined. The effects of self-attenuation on the low energy gamma rays were evaluated, and it was determined that Compton suppression was an effective characterization method of 239 Pu after accounting for self-attenuation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A global metagenomic map of urban microbiomes and antimicrobial resistance

We present a global atlas of 4,728 metagenomic samples from mass-transit systems in 60 cities over 3 years, representing the first systematic, worldwide catalog of the urban microbial ecosystem. This atlas provides an annotated, geospatial profile of microbial strains, functional characteristics, antimicrobial resistance (AMR) markers, and genetic elements, including 10,928 viruses, 1,302 bacteria, 2 archaea, and 838,532 CRISPR arrays not found in reference databases. We identified 4,246 known species of urban microorganisms and a consistent set of 31 species found in 97% of samples that were distinct from human commensal organisms. Profiles of AMR genes varied widely in type and density across cities. Cities showed distinct microbial taxonomic signatures that were driven by climate and geographic differences. These results constitute a high-resolution global metagenomic atlas that enables discovery of organisms and genes, highlights potential public health and forensic applications, and provides a culture-independent view of AMR burden in cities.

59 BASIC BIOLOGICAL SCIENCES↗

High-dimensional isotomics, part 2: Observations of over 100 constraints on methionine's isotome

The abundances of different isotopic forms of a compound, or isotopologues, will vary based on its physical and chemical history. The number of isotopologues increases combinatorically with the size of a molecule, and even small molecules such as amino acids have thousands of potentially observable isotopic variants. However, due to the analytical challenges of separating and observing isotopologues, only a few dimensions of isotopic diversity are routinely measured. Overcoming these challenges requires both an experimental method to observe many isotopic properties and a theoretical framework for interpreting these experiments. In Part 1, we presented such a theoretical framework; here, we demonstrate an experimental method, which we apply to methionine. Our approach uses a Q Exactive HF Orbitrap to perform several “M + N experiments”, where a sample is ionized, a subset of its isotopologues with cardinal mass N daltons greater than the unsubstituted isotopologue is selected and fragmented, and the proportions of all detectable isotopic forms of those fragment ions are quantified. We perform M + 1, M + 2, M + 3, and M + 4 experiments of a methionine sample and standard where the sample has a 100 ‰ enrichment of 13C at the methyl carbon relative to the natural 13C abundance at that position in the standard, and is otherwise identical to the standard. We observe isotopic forms of 8 fragment ion species for each version of the M + N experiment. With the assistance of a forward model of expected mass spectra, we identify isotopic peaks for each fragment ion based on observed mass and abundance, screen these for data quality, and quantify abundances for 146 unique isotopic peaks at precisions of ≈ 0.3–3 ‰. We present our direct observations and use them to reconstruct the concentrations of 19 individual singly, doubly, and triply-substituted isotopologues; doing so gives fewer constraints and broader error bars than working with the direct observations, but may be more interpretable for some applications. We also examine possibilities for measuring additional peaks, which are primarily limited by the detection limit of the Orbitrap-IRMS method. We then suggest some possible uses of our direct measurements for chemical forensics and hypothesis testing. Furthermore, our results demonstrate the diversity of isotopic constraints currently observable and interpretable for organic molecules.

58 GEOSCIENCES↗