Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flux analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Synthesis and characterization of rhenium chalcogenides for nuclear waste management

A new synthetic approach to binary rhenium (Re) chalcogenides was investigated to aid in the preparation of analogous technetium (Tc) compounds for Tc waste management efforts. The Boron-Chalcogen Mixture (BCM) method was utilized for the first time to prepare polycrystalline powders of ReS 2 , ReSe 2 , and Re 2 Te 5 using a perrhenate, NaReO4, as a rhenium source. Single crystals of ReS 2 were also synthesized using the combined BCM and molten flux methods by adding a K 2 CO 3 flux to the reagent mixture. Thermal analysis using TGA/DSC revealed negligible changes from ambient temperature up to ∼300 °C followed by the oxidation of the Re chalcogenides. High Temperature PXRD was used to investigate the crystallinity of ReS 2 at various temperatures revealing an increase in crystallinity up to 275 °C followed by a decrease in crystallinity due to oxidation. The research presented herein demonstrates a significant step towards technetium waste treatment efforts.

Boron chalcogen mixture (BCM) method↗

Vacuum-ultraviolet light source for enhanced production of metastable krypton and xenon beams

Here, we demonstrate excitation of metastable krypton and xenon beams using a vacuum ultraviolet lamp and directly compare the performance of this method to metastable excitation based on a radio-frequency-driven plasma discharge. In our apparatus, lamp-based metastable excitation outperforms the plasma discharge across a wide range of beam flux values relevant for atom trap trace analysis (ATTA). Moreover, we do not observe significant degradation in lamp performance after over 160 h of operation. We find that lamp-based excitation is particularly advantageous at the smallest and largest beam fluxes tested, demonstrating the utility of this approach both for improving krypton ATTA and for enabling the detection of radioactive xenon isotopes using ATTA. Finally, we demonstrate an additional enhancement to lamp-based metastable excitation efficiency and stability by applying an external magnetic field.

Metastable noble gases↗

Using atmospheric observations to quantify annual biogenic carbon dioxide fluxes on the Alaska North Slope

The continued warming of the Arctic could release vast stores of carbon into the atmosphere from high-latitude ecosystems, especially from thawing permafrost. Increasing uptake of carbon dioxide (CO 2 ) by vegetation during longer growing seasons may partially offset such release of carbon. However, evidence of significant net annual release of carbon from site-level observations and model simulations across tundra ecosystems has been inconclusive. To address this knowledge gap, we combined top-down observations of atmospheric CO 2 concentration enhancements from aircraft and a tall tower, which integrate ecosystem exchange over large regions, with bottom-up observed CO 2 fluxes from tundra environments and found that the Alaska North Slope is not a consistent net source nor net sink of CO 2 to the atmosphere (ranging from ₋6 to +6 Tg C yr -1 for 2012–2017). Our analysis suggests that significant biogenic CO 2 fluxes from unfrozen terrestrial soils, and likely inland waters, during the early cold season (September–December) are major factors in determining the net annual carbon balance of the North Slope, implying strong sensitivity to the rapidly warming freeze-up period. At the regional level, we find no evidence of the previously reported large late-cold-season (January–April) CO 2 emissions to the atmosphere during the study period. Despite the importance of the cold-season CO 2 emissions to the annual total, the interannual variability in the net CO 2 flux is driven by the variability in growing season fluxes. During the growing season, the regional net CO 2 flux is also highly sensitive to the distribution of tundra vegetation types throughout the North Slope. This study shows that quantification and characterization of year-round CO 2 fluxes from the heterogeneous terrestrial and aquatic ecosystems in the Arctic using both site-level and atmospheric observations are important to accurately project the Earth system response to future warming.

54 ENVIRONMENTAL SCIENCES↗

Assessing plasma face component thermal response to rotating 3D magnetic fields for SPARC tokamak

Thermal response simulations of plasma-facing components (PFCs) in the SPARC tokamak, performed with the HEAT code, show that three-dimensional (3D) heat loads resulting from stationary n=1 perturbations require highly radiative scenarios, with up to 95% of the power crossing the separatrix (P SOL ) being radiated, to maintain PFC temperatures within acceptable operational limits, whereas the application of slowly rotating 3D fields substantially reduces the thermal loads. The HEAT module, developed to predict heat loads from non-axisymmetric plasmas, is extended to model time-dependent heat flux patterns generated by rotating 3D fields, and a comprehensive thermal analysis is performed on PFCs subjected to both the maximum and minimum power loads, as well as to rotating heat flux distributions, to evaluate the temperature evolution for varying perturbation amplitudes and rotation frequencies. The extension of this analysis to 3D fields with toroidal mode number n=2 shows that this configuration leads to weaker localized heat flux peaks relative to the n=1 case, enabling safe operation with less than 80% of the power radiated when static 3D fields of low amplitude are applied, while using slowly rotating fields at higher amplitudes. These results indicate that n=2 perturbations are generally less detrimental to divertor power exhaust, emphasizing the strong dependence of divertor power exhaust on the characteristics of the applied 3D fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lowering the barrier to access information-rich transient kinetic data for machine learning methods

Transient kinetic data contain a wealth of information about intrinsic features of a catalyst as well as the reaction mechanism. Currently, high volume transient data is underutilized, and data science methods could both increase the value of information that can be extracted from this data, integrate experimental with theoretical data sources, and accelerate the pace of catalyst technology advancement. Transient kinetic characterizations with simple probe molecules exhibiting reversible adsorption, irreversible adsorption and bulk-surface diffusion are presented as training components for similar experiments with more complex surface reactions. In conclusion, by increasing the availability and accessibility of transient kinetic data through details of its structure and acquisition, we aim to decrease the barrier for data scientists to apply machine learning methods to this valuable data source.

Catalysis↗

Barriers and variable spacing enhance convective cooling and increase power output in solar PV plants

When the temperature of solar photovoltaic (PV) modules rises, efficiency drops and module degradation accelerates. Thus, it is beneficial to reduce module operating temperatures. Previous studies of solar power plants have illustrated that incoming flow characteristics, turbulent mixing, and array geometry can strongly impact convective cooling, as measured by the convective heat transfer coefficient h. In the fields of heat transfer and plant canopy flow, previous work has shown that system-scale arrangement modifications—e.g., variable spacing, barriers, or windbreaks—can passively alter the flow, enhance turbulent mixing, and influence convection. However, researchers have not yet explored how variable spacing or barriers might enhance convective cooling in solar power plants. Here, high-resolution large-eddy simulations model the air flow and heat transfer through solar power plant arrangements modified with missing modules and barrier walls. We then perform a control volume analysis to evaluate the net heat flux and compute h, which quantifies the influence of these spatial modifications on convective cooling and, thus, module temperature and power output. Installing barrier walls yields the greatest improvements, increasing h by 3.4%, reducing module temperature by an estimated 2.5 °C, and boosting power output by an estimated 1.4% on average. These findings indicate that incorporating variable spacing or barrier-type elements into PV plant designs can reduce module temperature and, thus, improve PV performance and service life.

14 SOLAR ENERGY↗

Testing predictions of electron scale turbulent pedestal transport in two DIII-D ELMy H-modes

In this study, we present linear and nonlinear gyrokinetic analyses in the pedestal region of two DIII-D ELMy H-mode discharges using the CGYRO code. The otherwise matched discharges employ different divertor configurations to investigate the impact of varying recycling and particle source on pedestal profiles. Linear gyrokinetic simulations find electrostatic ion-scale instabilities (ion temperature gradient and trapped electron modes, ITG-TEM) are present just inside the top of the pedestal with growth rates that are enhanced significantly by parallel velocity shear. In the sharp gradient region, E x B shearing rates are comparable or larger than ion scale growth rates, suggesting the suppression of ITG-TEM modes in this region. Instead, the electron temperature profiles are found to be correlated with and just above the electron temperature gradient (ETG) instability thresholds. Using gradients varied within experimental uncertainties, nonlinear electron-scale gyrokinetic simulations predict electron heat fluxes from ETG turbulence, that when added to neoclassical ion thermal transport simulated by NEO, account for 30-60% of the total experimental heat flux. In addition, the neoclassical electron particle flux is found to contribute significantly to the experimental fluxes inferred from SOLPS-ITER analysis. Additional nonlinear gyrokinetic simulations are run varying input gradients to develop a threshold-based reduced model for ETG transport, finding a relatively simple dependence on η e = L ne /L Te . Predictive transport simulations are used to validate this pedestal-specific ETG model, in conjunction with a model for neoclassical particle transport. In both discharges, the predicted electron temperatures are always overpredicted, indicative of the insufficient stiffness in the ETG pedestal model to account for all of the experimental electron thermal transport. In the case of the closed divertor discharge with lower particle source, the predicted electron density is close to the experiment, consistent with the magnitude of neoclassical particle transport in that discharge. However, the density profiles are overpredicted in the open divertor discharge (larger particle source), due to insufficient model transport. In conclusion, the implications for other mechanisms accounting for the remainder of transport in the sharp gradient region in the two discharges are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Vortices in spin-0 superfluids carry magnetic flux

Vortices in spin-0 superfluids generically carry magnetic fields inside their cores, so that even neutral superfluid vortices may be thought of as magnetic flux tubes. We give a systematic analysis of this ‘vortex magnetic effect’ using effective field theory, clarifying earlier literature on the subject. Furthermore, our analysis shows that in superfluid helium-4 the vortex magnetic effect may be large enough to be experimentally detectable.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Shrub Expansion Simulations at Trail Valley Creek Tundra site using E3SM Land Model (ELM) Arctic-focused Version

The warming of the Arctic is causing substantial compositional, structural, and functional changes in tundra vegetation including shrub and densification in parts of the Arctic. Assessing the impact of these changes in vegetation composition on the Arctic’s carbon and energy budgets is important to constrain projected local and global surface-atmosphere exchanges. We conduct a sensitivity analysis of the projected surface energy fluxes, soil carbon pools, and carbon dioxide fluxes (net ecosystem exchange, gross primary production, and ecosystem respiration) between present day and 2100 to different shrub expansion rates and air temperature increases under future emission scenarios (intermediate – RCP4.5, and high – RCP8.5) using the Arctic-focused version of the Energy Exascale Earth System Model (E3SM) Land Model (ELM). We focus on Trail Valley Creek (TVC), a mineral upland tundra site located in the western Canadian Arctic, which is experiencing tall shrub densification and expansion. In this study, we run TVC under two different warming scenarios RCP4.5 and RCP 8.5 and simulate different shrubification rates projected until year 2100. In this repository, we include all the forcing, input, parameters, and output data corresponding to all the simulations performed. flmd.csv includes a detailed description of the datasets files.

54 ENVIRONMENTAL SCIENCES↗

Boiling-Water Reactor Testing Capability in the Advanced Test Reactor

I-Loop is an irradiation facility that is currently being installed at the Advanced Test Reactor. It is a two-loop test facility capable of performing Light Water Reactor (LWR) irradiations in prototypic coolant conditions. The two loops are being installed to be capable of both Boiling Water Reactor (BWR) and Pressurized Water Reactor (PWR) pressure, temperature, and chemistry environments. Each loop is nominally dedicated as a BWR or PWR for simplicity of operations. In-reactor water loop testing that an I-Loop provides is key to the deployment of new accident tolerant fuel technologies and other advanced LWR fuel concepts. Currently, pressurized water loops are the only testing facilities available to test BWR fuel concepts. Their test environments are non-prototypic at higher pressure/temperature and at single-phase fluid flow conditions. This void in the LWR test bed capabilities is one that the I-Loop is uniquely situated to provide. This report discusses the mechanical design, thermal hydraulic calculations, and neutronic calculations of a proposed standard experiment of accident tolerant BWR fuel concepts. Mechanical design examines the geometry and features of the main components. Thermal hydraulic calculations examine the modeling and results of the two-phase flow options available. Lastly, neutronic calculations examine the Monte Carlo analysis of enrichment, heat rates, and flux spectrum.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-performance Generic Neutrino Detection in a LArTPC near the Earth's Surface with the MicroBooNE Detector

Large Liquid Argon Time Projection Chambers (LArTPCs) are being increasingly adopted in neutrino oscillation experiments because of their superb imaging capabilities through the combination of both tracking and calorimetry in a fully active volume. Active LArTPC neutrino detectors at or near the Earth's surface, such as the MicroBooNE experiment, present a unique analysis challenge because of the large flux of cosmic-ray muons and the slow drift of ionization electrons. We present a novel Wire-Cell-based high-performance generic neutrino-detection technique implemented in MicroBooNE. The cosmic-ray background is reduced by a factor of 1.4$\times10^{5}$ resulting in a 9.7% cosmic contamination in the selected neutrino candidate events, for visible energies greater than 200~MeV, while the neutrino signal efficiency is retained at 88.4% for $\nu_{\mu}$ charged-current interactions in the fiducial volume in the same energy region. This significantly improved performance compared to existing reconstruction algorithms, marks a major milestone toward reaching the scientific goals of LArTPC neutrino oscillation experiments operating near the Earth's surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of Neutron Irradiation on the Bond Strength of Steel Embedded in Concrete

The structural integrity of the concrete biological shield (CBS) in light water reactors (LWRs) exposed to long-term radiation raises the question of the effects of fast-neutron and gamma irradiation on the bond properties of embedded carbon-steel reinforcement in concrete, which is critical to the transfer of in-service and accidental loads. The design and execution of a first-of-a-kind irradiation experiment conducted in the LVR-15 test reactor (Czech Republic) are presented along with preliminary post-irradiation examination and testing results. Preliminary analysis shows that the fast neutron flux affects the radiation-induced volumetric of concrete aggregate, that the gamma irradiation induces shrinkage of the chemically bonded water in cementitious hydrates and that the bond strength of steel in concrete at the tested irradiation conditions decreases moderately.

Le Pape, Yann↗

A coupled ground heat flux–surface energy balance model of evaporation using thermal remote sensing observations

Abstract. One of the major undetermined problems in evaporation (ET) retrieval using thermal infrared remote sensing is the lack of a physically based ground heat flux (G) model and its integration within the surface energy balance (SEB) equation. Here, we present a novel approach based on coupling a thermal inertia (TI)-based mechanistic G model with an analytical surface energy balance model, Surface Temperature Initiated Closure (STIC, version STIC1.2). The coupled model is named STIC-TI. The model is driven by noon–night (13:30 and 01:30 local time) land surface temperature, surface albedo, and a vegetation index from MODIS Aqua in conjunction with a clear-sky net radiation sub-model and ancillary meteorological information. SEB flux estimates from STIC-TI were evaluated with respect to the in situ fluxes from eddy covariance measurements in diverse ecosystems of contrasting aridity in both the Northern Hemisphere and Southern Hemisphere. Sensitivity analysis revealed substantial sensitivity of STIC-TI-derived fluxes due to the land surface temperature uncertainty. An evaluation of noontime G (Gi) estimates showed 12 %–21 % error across six flux tower sites, and a comparison between STIC-TI versus empirical G models also revealed the substantially better performance of the former. While the instantaneous noontime net radiation (RNi) and latent heat flux (LEi) were overestimated (15 % and 25 %), sensible heat flux (Hi) was underestimated (22 %). Overestimation (underestimation) of LEi (Hi) was associated with the overestimation of net available energy (RNi−Gi) and use of unclosed surface energy balance flux measurements in LEi (Hi) validation. The mean percent deviations in Gi and Hi estimates were found to be strongly correlated with satellite day–night view angle difference in parabolic and linear pattern, and a relatively weak correlation was found between day–night view angle difference versus LEi deviation. Findings from this parameter-sparse coupled G–ET model can make a valuable contribution to mapping and monitoring the spatiotemporal variability of ecosystem water stress and evaporation using noon–night thermal infrared observations from future Earth observation satellite missions such as TRISHNA, LSTM, and SBG.

Bhattacharya, Bimal K.↗

Liquid lithium divertor analysis using coupled plasma material interaction model

A liquid lithium divertor can improve performance of future fusion devices by creating efficient power exhaust and improving the energy confinement via pumping of the hydrogen isotopes. In addition, significantly higher heat fluxes can be handled if controlled vapor shielding is used to redistribute the divertor heat flux over a wider area. Design and optimization of such a system calls for an analysis model which includes a strong two-way coupling between the plasma and divertor material. The incoming plasma heat and particle flux will affect the divertor surface temperature, which is a defining factor of the lithium evaporative and sputtered flux going into the plasma. Results of the coupled model based on the plasma edge code SOLPS-ITER and the computational fluid dynamics (CFD) code ANSYS-CFX will be presented for different configurations. An analytical slab flow model is used as a heat transfer boundary condition for SOLPS, defining particle flux from the wall via calculation of the surface temperature. At the final step, results of the SOLPS analysis are verified using a 3D CFD magnetohydrodynamics (MHD) analysis which uses heat and particle flux from SOLPS as a boundary condition. In addition to plasma heat flux, both analytical and CFD temperature models include several plasma material interaction effects, such as lithium evaporation, condensation and sputtering based on deuterium target flux. New adatom sputtering model based on the available experimental data is presented. Analytical model is expanded to include free surface axisymmetric configurations. Results of parametric studies of the divertor configurations with different lithium inlet temperature and velocity will be presented leading to the optimal design resulting in the lowest possible lithium contamination in the core.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Validation and moisture content sensitivity analysis of cross-laminated timber wall assemblies in EnergyPlus

Cross-laminated timber buildings are becoming more common in North America, with many numerical studies showing potential energy savings. However, no studies have validated any EnergyPlus heat transfer algorithms or quantified their accuracy in simulating CLT in building envelopes. This study empirically validates the heat flux predictions for each of EnergyPlus's heat transfer algorithms (Conduction Transfer Functions (CTF), Effective Moisture Penetration Depth (EMPD), Conduction Finite Difference (CondFD), and Heat and Moisture Transfer (HAMT)) for two different CLT ply thicknesses with both summer and winter boundary conditions measured in controlled lab experiments. It also evaluates the model sensitivity of heat flux and heating and cooling loads to moisture content. The 1D validation shows that the HAMT model is the most accurate among all algorithms. All EnergyPlus's heat flux predictions are accurate independent of CLT plate thickness for summer conditions. However, the three constant property algorithms (CTF, EMPD, and CondFD) underpredict heat flux throughout the whole day during winter conditions. The 1D sensitivity analysis indicates that elevated moisture content can increase peak heat fluxes through the material by up to 20 %. Finally, the whole building model sensitivity analysis shows increased heating load and slight cooling load variation due to increased moisture content when using constant property models. The analysis shows significantly lower peak thermal demand (7 % lower heating and 6 % lower cooling) and monthly thermal load (8 % less cooling and 6 % less heating) predictions when using HAMT vs a constant property model.

42 ENGINEERING↗

Antiprotons and Elementary Particles over a Solar Cycle: Results from the Alpha Magnetic Spectrometer

We present results over an 11-year Solar cycle of cosmic antiprotons based on 1.1 × 10 6 events in the rigidity range from 1.00 to 41.9 GV. The $\bar{𝑝}$ fluxes exhibit distinct properties. The magnitude of the $\bar{𝑝}$ flux temporal variation is significantly smaller than those of 𝑝, 𝑒 − , and 𝑒 + . A hysteresis between the $\bar{𝑝}$ fluxes and the 𝑝 fluxes is observed, whereas the $\bar{𝑝}$ and 𝑒 − fluxes show a linear correlation. With a model-independent analysis, we found a universal relation between the shape of the rigidity spectrum and the magnitude of flux temporal variation over an 11-year Solar cycle for both positively and negatively charged particles. The simultaneous results on $\bar{𝑝}$ and 𝑝, 𝑒 − , and 𝑒 + provide unique information for understanding particle transport in the Solar System as a function of mass, charge, and spectral shape.

cosmic ray composition & spectra↗