Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flexible electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18

Direct synthesis of biaxially textured nickel disilicide thin films by magnetron sputter deposition on low-cost metal tapes for flexible silicon devices

Nickel silicides are widely used as contact materials for electronic devices based on silicon (Si). However, they have been predominantly fabricated by annealing separate Ni and Si phases which leads to phase and structural complexity. In this letter, direct epitaxial growth of a single-phase nickel disilicide (NiSi 2 ) thin film by sputter deposition of NiSi 2 is achieved on low-cost and flexible Hastelloy tapes which offers a promising route to fabricate low-cost, flexible electronic devices. Biaxially textured titanium nitride (TiN) is applied as the seeding layer and the diffusion barrier under NiSi 2 . An epitaxial relationship of (001)$\langle$100$\rangle$NiSi 2 ∥ (001)$\langle$110$\rangle$TiN is observed with an extra-large lattice mismatch (~10.3%) between NiSi 2 and TiN. Both the bonding similarity and the passivation effect by hydrogen promote the epitaxial growth of NiSi 2 on TiN. The flat and smooth NiSi 2 thin film consists of grains with a size of 50–100 nm. An epitaxially grown Si film on NiSi 2 further demonstrates the potential of manufacturing high-performance Si flexible electronics with NiSi 2 /TiN/Hastelloy as the direct contact through this approach.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Methylxanthine Drug Monitoring with Wearable Sweat Sensors

Drug monitoring plays crucial roles in doping control and precision medicine. It helps physicians tailor drug dosage for optimal benefits, track patients' compliance to prescriptions, and understand the complex pharmacokinetics of drugs. Conventional drug tests rely on invasive blood draws. While urine and sweat are attractive alternative biofluids, the state-of-the-art methods require separate sample collection and processing steps and fail to provide real-time information. In this paper, a wearable platform equipped with an electrochemical differential pulse voltammetry sensing module for drug monitoring is presented. A methylxanthine drug, caffeine, is selected to demonstrate the platform's functionalities. Sweat caffeine levels are monitored under various conditions, such as drug doses and measurement time after drug intake. Elevated sweat caffeine levels upon increasing dosage and confirmable caffeine physiological trends are observed. This work leverages a wearable sweat sensing platform toward noninvasive and continuous point-of-care drug monitoring and management.

47 OTHER INSTRUMENTATION↗

Asymmetric Flexible MXene-Reduced Graphene Oxide Micro-Supercapacitor

Current microfabrication of micro–supercapacitors often involves multistep processing and delicate lithography protocols. In this study, simple fabrication of an asymmetric MXene–based micro–supercapacitor that is flexible, binder–free, and current–collector–free is reported. Here, the interdigitated device architecture is fabricated using a custom–made mask and a scalable spray coating technique onto a flexible, transparent substrate. The electrode materials are comprised of titanium carbide MXene (Ti 3 C 2 T x ) and reduced graphene oxide (rGO), which are both 2D layered materials that contribute to the fast ion diffusion in the interdigitated electrode architecture. This MXene–based asymmetric micro–supercapacitor operates at a 1 V voltage window, while retaining 97% of the initial capacitance after ten thousand cycles, and exhibits an energy density of 8.6 mW h cm –3 at a power density of 0.2 W cm –3 . Further, these micro–supercapacitors show a high level of flexibility during mechanical bending. Utilizing the ability of Ti 3 C 2 T x – MXene electrodes to operate at negative potentials in aqueous electrolytes, it is shown that using Ti 3 C 2 T x as a negative electrode and rGO as a positive one in asymmetric architectures is a promising strategy for increasing both energy and power densities of micro–supercapacitors.

36 MATERIALS SCIENCE↗

Pressure‐Induced Emission (PIE) and Phase Transition of a Two‐dimensional Halide Double Perovskite (BA) 4 AgBiBr 8 (BA=CH 3 (CH 2 ) 3 NH 3 + )

Abstract Two‐dimensional (2D) halide perovskites have attracted significant attention due to their compositional flexibility and electronic diversity. Understanding the structure–property relationships in 2D double perovskites is essential for their development for optoelectronic applications. In this work, we observed the emergence of pressure‐induced emission (PIE) at 2.5 GPa with a broad emission band and large Stokes shift from initially nonfluorescent (BA) 4 AgBiBr 8 (BA=CH 3 (CH 2 ) 3 NH 3 + ). The emission intensity increased significantly upon further compression up to 8.2 GPa. Moreover, the band gap narrowed from the starting 2.61 eV to 2.19 eV at 25.0 GPa accompanied by a color change from light yellow to dark yellow. Analysis of combined in situ high‐pressure photoluminescence, absorption, and angle‐dispersive X‐ray diffraction data indicates that the observed PIE can be attributed to the emission from self‐trapped excitons. This coincides with [AgBr 6 ] 5− and [BiBr 6 ] 3− inter‐octahedral tilting which cause a structural phase transition. High‐pressure study on (BA) 4 AgBiBr 8 sheds light on the relationship between the structure and optical properties that may improve the material's potential applications in the fields of pressure sensing, information storage and trademark security.

Fang, Yuanyuan↗

Pressure‐Induced Emission (PIE) and Phase Transition of a Two‐dimensional Halide Double Perovskite (BA) 4 AgBiBr 8 (BA=CH 3 (CH 2 ) 3 NH 3 + )

Abstract Two‐dimensional (2D) halide perovskites have attracted significant attention due to their compositional flexibility and electronic diversity. Understanding the structure–property relationships in 2D double perovskites is essential for their development for optoelectronic applications. In this work, we observed the emergence of pressure‐induced emission (PIE) at 2.5 GPa with a broad emission band and large Stokes shift from initially nonfluorescent (BA) 4 AgBiBr 8 (BA=CH 3 (CH 2 ) 3 NH 3 + ). The emission intensity increased significantly upon further compression up to 8.2 GPa. Moreover, the band gap narrowed from the starting 2.61 eV to 2.19 eV at 25.0 GPa accompanied by a color change from light yellow to dark yellow. Analysis of combined in situ high‐pressure photoluminescence, absorption, and angle‐dispersive X‐ray diffraction data indicates that the observed PIE can be attributed to the emission from self‐trapped excitons. This coincides with [AgBr 6 ] 5− and [BiBr 6 ] 3− inter‐octahedral tilting which cause a structural phase transition. High‐pressure study on (BA) 4 AgBiBr 8 sheds light on the relationship between the structure and optical properties that may improve the material's potential applications in the fields of pressure sensing, information storage and trademark security.

Fang, Yuanyuan↗

Polylactic acid (PLA)-based multifunctional and biodegradable nanocomposites and their applications

Polylactic acid (PLA)-based nanocomposites are emerging as multifunctional, biodegradable materials, offering sustainable alternatives to petroleum-based plastics. This review examines recent advancements in PLA nanocomposites, focusing on enhanced mechanical strength, thermal stability, and biodegradability achieved through nanofillers like metallic particles, carbon-based materials, and ceramics. Techniques such as in situ polymerization, melt mixing, and electrospinning enable application-specific improvements. PLA's limitations, including brittleness and low barrier properties, are addressed to support diverse applications: in packaging (e.g., extended shelf life), biomedicine (e.g., degradable implants), and electronics (e.g., flexible devices). Despite challenges with filler dispersion and thermal resistance, continued innovations expand PLA's potential across multiple industries, contributing to a sustainable, circular economy.

Biodegradable polymers↗

Increased fracture depth range in controlled spalling of (100)-oriented germanium via electroplating

Controlled spalling in (100)-oriented germanium using a nickel stressor layer shows promise for semiconductor device exfoliation and kerfless wafering. Demonstrated spall depths of 7-60 um using DC sputtering to deposit the stressor layer are appropriate for the latter application but spall depths < 5 um may be required to minimize waste for device applications. This work investigates the effect of tuning both electroplating current density and electrolyte chemistry on the residual stress in the nickel and on the achievable spall depth range for the Ni/Ge system as a lower-cost, higher-throughput alternative to sputtering. By tuning current density and electrolyte phosphorous concentration, it is shown that electroplating can successfully span the same range of spalled thicknesses as has previously been demonstrated by sputtering and can reach sufficiently high stresses to enter a regime of thickness (<7 um) appropriate to minimize substrate consumption for device applications.

14 SOLAR ENERGY↗

Magnetic La 0.7 Sr 0.3 MnO 3 Membranes Synthesized by Etching a Sr 3 Al 2 O 6 Sacrificial Layer Using an Intermediary Manganite Protection Layer

The integration of perovskite oxides onto flexible substrates has witnessed significant advancements owing to the development of an epitaxial lift-off technique utilizing a Sr 3 Al 2 O 6 sacrificial layer. However, Sr 3 Al 2 O 6 is susceptible to instability in both air and high-temperature oxygen atmospheres, potentially leading to degradation during the growth of the functional oxide layer. In this study, we investigate the use of an oxygen-deficient La 0.7 Sr 0.3 MnO 3 as capping layer, and demonstrate its ability to stabilize Sr 3 Al 2 O 6 films in ambient air. We successfully synthesized freestanding La 0.7 Sr 0.3 MnO 3 membranes by etching this sacrificial layer and transferring them onto flexible polymer substrates. Importantly, the magnetic properties of the La 0.7 Sr 0.3 MnO 3 films are preserved in these membranes. Furthermore, our results underline that employing a thin manganite capping layer ensures both high structural quality and the preservation of functional properties in the resulting membranes.

Deposition↗

Correlation of Spatiotemporal Dynamics of Polarization and Charge Transport in Blended Hybrid Organic–Inorganic Perovskites on Macro- and Nanoscales

Progress in flexible organic electronics necessitates a full understanding of how local inhomogeneities impact electronic and ionic conduction pathways and underlie macroscopic device characteristics. In this work, we used frequency- and time-resolved macro- and nanoprobe measurements to study spatiotemporal characteristics of multiscale charge transport dynamics in a series of ternary-blended hybrid organic inorganic perovskites (HOIPs) (MA 0.95– x FA x Cs 0.05 PbI 3 ). We show that A-site cation composition defines charge transport mechanisms across broad temporal (10 2 –10 –6 s) and spatial (millimeters–picometers) scales. Ab initio molecular dynamic simulations suggest that insertion of FA results in a dynamic lattice, improved ion transport, and dipole screening. We demonstrate that correlations between macro- and nanoscale measurements provide a pathway for accessing distribution of relaxation in nanoscale polarization and charge transport dynamics of ionically conductive functional perovskites.

36 MATERIALS SCIENCE↗

A Wearable Electrochemical Platform for Noninvasive Simultaneous Monitoring of Ca 2+ and pH

Homeostasis of ionized calcium in biofluids is critical for human biological functions and organ systems. Measurement of ionized calcium for clinical applications is not easily accessible due to its strict procedures and dependence on pH. pH balance in body fluids greatly affects metabolic reactions and biological transport systems. Here, we demonstrate a wearable electrochemical device for continuous monitoring of ionized calcium and pH of body fluids using a disposable and flexible array of Ca 2+ and pH sensors that interfaces with a flexible printed circuit board. This platform enables real-time quantitative analysis of these sensing elements in body fluids such as sweat, urine, and tears. Accuracy of Ca 2+ concentration and pH measured by the wearable sensors is validated through inductively coupled plasma-mass spectrometry technique and a commercial pH meter, respectively. Our results show that the wearable sensors have high repeatability and selectivity to the target ions. Real-time on-body assessment of sweat is also performed, and our results indicate that calcium concentration increases with decreasing pH. Finally, this platform can be used in noninvasive continuous analysis of ionized calcium and pH in body fluids for disease diagnosis such as primary hyperparathyroidism and kidney stones.

47 OTHER INSTRUMENTATION↗

Flexible Quasi-Two-Dimensional CoFe 2 O 4 Epitaxial Thin Films for Continuous Strain Tuning of Magnetic Properties

Epitaxial thin films of CoFe 2 O 4 (CFO) have successfully been transferred from a SrTiO 3 substrate onto a flexible polyimide substrate. By bending the flexible polyimide, different levels of uniaxial strain are continuously introduced into the CFO epitaxial thin films. Unlike traditional epitaxial strain induced by substrates, the strain from bending will not suffer from critical thickness limitation, crystalline quality variation, and substrate clamping, and more importantly, it provides a more intrinsic and reliable way to study strain-controlled behaviors in functional oxide systems. It is found that both the saturation magnetization and coercivity of the transferred films can be changed over the bending status and show a high accord with the movement of the curvature bending radius of the polyimide substrate. Lastly, this reveals that the mechanical strain plays a critical role in tuning the magnetic properties of CFO thin films parallel and perpendicular to the film plane direction.

36 MATERIALS SCIENCE↗

Roll-to-Roll Gravure Printed Electrochemical Sensors for Wearable and Medical Devices

As recent developments in noninvasive biosensors spearhead the thrust toward personalized health and fitness monitoring, there is a need for high throughput, cost-effective fabrication of flexible sensing components. Toward this goal, in this paper we present roll-to-roll (R2R) gravure printed electrodes that are robust under a range of electrochemical sensing applications. We use inks and electrode morphologies designed for electrochemical and mechanical stability, achieving devices with uniform redox kinetics printed on 150 m flexible substrate rolls. We show that these electrodes can be functionalized into consistently high performing sensors for detecting ions, metabolites, heavy metals, and other small molecules in noninvasively accessed biofluids, including sensors for real-time, in situ perspiration monitoring during exercise. This development of robust and versatile R2R gravure printed electrodes represents a key translational step in enabling large-scale, low-cost fabrication of disposable wearable sensors for personalized health monitoring applications.

42 ENGINEERING↗

Nicotine Monitoring with a Wearable Sweat Band

The tobacco epidemic is a public health threat that has taken a heavy toll of lives around the globe each year. Smoking affects both the smokers and those who are exposed to secondhand smoke, and careful tracking of exposure can be key to mitigating the potential hazards. For smokers, the variation of chemical compositions between commercial cigarettes has led to ambiguity in estimating the health risks, both for active smokers and others involuntarily exposed to tobacco smoke and byproducts. In this regard, sweat possesses an attractive opportunity to monitor smoke exposure due to sweat's abundance in biomolecules and its great accessibility. In this paper, we present a wearable sweat band to monitor nicotine, a prominent ingredient in cigarettes, as a viable way to quantitatively assess a wearer's exposure to smoking. Both smokers and normal subjects are tested to demonstrate the use of this device for smoke-related health monitoring. Our results exhibit confirmable and elevated nicotine levels in sweat for subjects inhaling cigarette smoke. This continuous and personalized sweat sensing device is leverage to monitor smoke pollution for a potentially broad population.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wearable Microsensor Array for Multiplexed Heavy Metal Monitoring of Body Fluids

A flexible and wearable microsensor array is described for simultaneous multiplexed monitoring of heavy metals in human body fluids. Zn, Cd, Pb, Cu, and Hg ions are chosen as target analytes for detection via electrochemical square wave anodic stripping voltammetry (SWASV) on Au and Bi microelectrodes. The oxidation peaks of these metals are calibrated and compensated by incorporating a skin temperature sensor. High selectivity, repeatability, and flexibility of the sensor arrays are presented. Human sweat and urine samples are collected for heavy metal analysis, and measured results from the microsensors are validated through inductively coupled plasma mass spectrometry (ICP-MS). Real-time on-body evaluation of heavy metal (e.g., zinc and copper) levels in sweat of human subjects by cycling is performed to examine the change in concentrations with time. Finally, this platform is anticipated to provide insightful information about an individual's health state such as heavy metal exposure and aid the related clinical investigations.

47 OTHER INSTRUMENTATION↗

A Wearable Microfluidic Sensing Patch for Dynamic Sweat Secretion Analysis

Wearable sweat sensing is a rapidly rising research area driven by its promising potential in health, fitness, and diagnostic applications. Despite the growth in the field, major challenges in relation to sweat metrics remain to be addressed. These challenges include sweat rate monitoring for its complex relation with sweat compositions and sweat sampling for sweat dynamics studies. Here, we present a flexible microfluidic sweat sensing patch that enhances real-time electrochemical sensing and sweat rate analysis via sweat sampling. The device contains a spiral-patterned microfluidic component that is embedded with ion-selective sensors and an electrical impedance-based sweat rate sensor on a flexible plastic substrate. The patch is enabled to autonomously perform sweat analysis by interfacing the sensing component with a printed circuit board that is capable of on-site signal conditioning, analysis, and transmission. Progressive sweat flow in the microfluidic device, governed by the pressure induced by the secreted sweat, enhances sweat sampling and electrochemical detection via a defined sweat collection chamber and a directed sweat route. The characteristic of the sweat rate sensor is validated through a theoretical simulation, and the precision and accuracy of the flow rate is verified with a commercial syringe pump and a Macroduct sweat collector. On-body simultaneous monitoring of ion (H + , Na + , K + , Cl – ) concentration and sweat rate is also demonstrated for sensor functionality. This sweat sensing patch provides an integrated platform for a comprehensive sweat secretion analysis and facilitates physiological and clinical investigations by closely monitoring interrelated sweat parameters.

47 OTHER INSTRUMENTATION↗

Aerosol jet printed capacitive strain gauge for soft structural materials

Soft structural textiles, or softgoods, are used within the space industry for inflatable habitats, parachutes and decelerator systems. Evaluating the safety and structural integrity of these systems occurs through structural health monitoring systems (SHM), which integrate non-invasive/non-destructive testing methods to detect, diagnose, and locate damage. Strain/load monitoring of these systems is limited while utilizing traditional strain gauges as these gauges are typically stiff, operate at low temperatures, and fail when subjected to high strain that is a result of high loading classifying them as unsuitable for SHM of soft structural textiles. For this work, a capacitance based strain gauge (CSG) was fabricated via aerosol jet printing (AJP) using silver nanoparticle ink on a flexible polymer substrate. Printed strain gauges were then compared to a commercially available high elongation resistance-based strain gauge (HE-RSG) for their ability to monitor strained Kevlar straps having a 26.7?kN (6?klbf) load. Dynamic, static and cyclic loads were used to characterize both types of strain monitoring devices. Printed CSGs demonstrated superior performance for high elongation strain measurements when compared to commonly used HE-RSGs, and were observed to operate with a gauge factor of 5.2 when the electrode arrangement was perpendicular to the direction of strain.

36 MATERIALS SCIENCE↗

Superconducting properties in tantalum decorated three-dimensional graphene and carbon structures

We present here the results on superconducting properties in tantalum thin films (100 nm thick) deposited on three-dimensional graphene (3DG) and carbon structures. A superconducting transition is observed in both composite thin films with a superconducting transition temperature of 1.2 K and 1.0 K, respectively. We have further measured the magnetoresistance at various temperatures and differential resistance dV/dI at different magnetic fields in these two composite thin films. In both samples, a much large critical magnetic field (∼2 T) is observed and this critical magnetic field shows linear temperature dependence. Finally, an anomalously large cooling effect was observed in the differential resistance measurements in our 3DG-tantalum device when the sample turns superconducting. Our results may have important implications in flexible superconducting electronic device applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗