Optimal Matched Filter in the Low-number Count Poisson Noise Regime and Implications for X-Ray Source Detection

Detection of templates (e.g., sources) embedded in low-number count Poisson noise is a common problem in astrophysics. Examples include source detection in X-ray images, γ-rays, UV, neutrinos, and search for clusters of galaxies and stellar streams. However, the solutions in the X-ray-related literature are sub-optimal in some cases by considerable factors. Using the lemma of Neyman–Pearson, we derive the optimal statistics for template detection in the presence of Poisson noise. We demonstrate that, for known template shape (e.g., point sources), this method provides higher completeness, for a fixed false-alarm probability value, compared with filtering the image with the point-spread function (PSF). In turn, we find that filtering by the PSF is better than filtering the image using the Mexican-hat wavelet (used by wavdetect). For some background levels, our method improves the sensitivity of source detection by more than a factor of two over the popular Mexican-hat wavelet filtering. This filtering technique can also be used for fast PSF photometry and flare detection; it is efficient and straightforward to implement. We provide an implementation in MATLAB. The development of a complete code that works on real data, including the complexities of background subtraction and PSF variations, is deferred for future publication.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of subsurface soil moisture variability and atmospheric conditions on methane gas migration in shallow subsurface

We report a major concern resulting from the increased use and production of natural gas has been how to mitigate fugitive greenhouse gas emissions (predominantly methane) from natural gas infrastructure (e.g., leaky shallow pipelines). Subsurface migration and atmospheric loading of methane from pipeline leakage is controlled by source configurations and subsurface soil conditions (e.g., soil heterogeneity and soil moisture) and are further affected by atmospheric conditions (e.g., wind and temperature). However, the transport and attenuation of methane under varying subsurface and atmospheric conditions are poorly understood, making it difficult to estimate leakage fluxes from methane concentration measurements at and above the soil surface. Based on a series of controlled bench-scale experiments using a large porous media tank interfaced with an open-return wind tunnel, this study investigated multiphase processes controlling migration of methane from a point source representing a buried pipeline leaking at fixed flow rate (kg/s) under various saturation and soil-texture conditions. In addition, potential effects of atmospheric boundary controls, wind (0.5 and 2.0 m s -1 ) and temperature (22 and 35 °C), were also examined. Results showed the distinct effects of soil heterogeneity and, to a varying degree, of soil moisture on surface methane concentrations. In addition, results also showed the pronounced effects of wind and, to a lesser degree, of temperature on surface methane concentrations in the presence of varying soil and moisture conditions. The observed subsurface methane profiles were simulated using the multiphase transport simulator TOUGH2-EOS7CA. Observed agreement between measured and simulated data demonstrates that for the conditions studied, multiphase migration of a multicomponent gas mixture (including methane) under density-dependent flow can be adequately represented with a Fickian advection-diffusion (or dispersion) model (ADM) framework. The dominant effect of saturation over the soil texture, could also be inferred from numerical characterization.

09 BIOMASS FUELS↗

Bug fixes / enhancements to Parallel tempering Markov chain Monte Carlo sampler (PTMCMCSampler) v3

Markov chain Monte Carlo sampler useful for a variety of problems for optimization, numerical integration, and generating draws from a probability distribution. They are often used in physical and mathematical problems, especially when it is difficult or impossible to use other approaches. This disclosure is for new bug fixes and enhancements to an existing open source library that is already in the public domain under the MIT license. https://github.com/jellis18/PTMCMCSampler

Forrer, Mark↗

LCLS Heavy Met Outgassing Tests

A Heavy Met that is 95% tungsten, 3% nickel and 2% iron and sintered to 100% density and is Ultra High Vacuum (UHV) compatible is proposed for use as the X-ray slit in the Front End Enclosure and the Fixed Mask for the Linac Coherent Light Source (LCLS). The Heavy Met was tested in the LLNL Vacuum Sciences and Engineering Lab (VSEL) to determine its outgassing rate and its overall compatibility with the vacuum requirements for LCLS.

43 PARTICLE ACCELERATORS↗

Anderson acceleration with approximate calculations: Applications to scientific computing

Here we provide rigorous theoretical bounds for Anderson acceleration (AA) that allow for approximate calculations when applied to solve linear problems. We show that, when the approximate calculations satisfy the provided error bounds, the convergence of AA is maintained while the computational time could be reduced. We also provide computable heuristic quantities, guided by the theoretical error bounds, which can be used to automate the tuning of accuracy while performing approximate calculations. For linear problems, the use of heuristics to monitor the error introduced by approximate calculations, combined with the check on monotonicity of the residual, ensures the convergence of the numerical scheme within a prescribed residual tolerance. Motivated by the theoretical studies, we propose a reduced variant of AA, which consists in projecting the least-squares used to compute the Anderson mixing onto a subspace of reduced dimension. The dimensionality of this subspace adapts dynamically at each iteration as prescribed by the computable heuristic quantities. We numerically show and assess the performance of AA with approximate calculations on: (i) linear deterministic fixed-point iterations arising from the Richardson's scheme to solve linear systems with open-source benchmark matrices with various preconditioners and (ii) non-linear deterministic fixed-point iterations arising from non-linear time-dependent Boltzmann equations.

97 MATHEMATICS AND COMPUTING↗

Singularity-free solutions for anisotropic charged fluids with Chaplygin equation of state

We extend the Krori-Barua analysis of the static, spherically symmetric, Einstein-Maxwell field equations and consider charged fluid sources with anisotropic stresses. The inclusion of a new variable (tangential pressure) allows the use of a nonlinear, Chaplygin-type equation of state with coefficients fixed by the matching conditions at the boundary of the source. Some physical features are briefly discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of genetic diversity, agronomic traits, and anthracnose resistance in the NPGS Sudan Sorghum Core collection

The United States Department of Agriculture (USDA) National Plant Germplasm System (NPGS) sorghum core collection contains 3011 accessions randomly selected from 77 countries. Genomic and phenotypic characterization of this core collection is necessary to encourage and facilitate its utilization in breeding programs and to improve conservation efforts. In this study, we examined the genome sequences of 318 accessions belonging to the NPGS Sudan sorghum core set, and characterized their agronomic traits and anthracnose resistance response. We identified 183,144 single nucleotide polymorphisms (SNPs) located within or in proximity of 25,124 annotated genes using the genotyping-by-sequencing (GBS) approach. The core collection was genetically highly diverse, with an average pairwise genetic distance of 0.76 among accessions. Population structure and cluster analysis revealed five ancestral populations within the Sudan core set, with moderate to high level of genetic differentiation. In total, 171 accessions (54%) were assigned to one of these populations, which covered 96% of the total genomic variation. Genome scan based on Tajima’s D values revealed two populations under balancing selection. Phenotypic analysis showed differences in agronomic traits among the populations, suggesting that these populations belong to different ecogeographical regions. A total of 55 accessions were resistant to anthracnose; these accessions could represent multiple resistance sources. Genome-wide association study based on fixed and random model Circulating Probability (farmCPU) identified genomic regions associated with plant height, flowering time, panicle length and diameter, and anthracnose resistance response. Integrated analysis of the Sudan core set and sorghum association panel indicated that a large portion of the genetic variation in the Sudan core set might be present in breeding programs but remains unexploited within some clusters of accessions. The NPGS Sudan core collection comprises genetically and phenotypically diverse germplasm with multiple anthracnose resistance sources. Population genomic analysis could be used to improve screening efforts and identify the most valuable germplasm for breeding programs. The new GBS data set generated in this study represents a novel genomic resource for plant breeders interested in mining the genetic diversity of the NPGS sorghum collection.

59 BASIC BIOLOGICAL SCIENCES↗

Low- Z polymer sample supports for fixed-target serial femtosecond X-ray crystallography

X-ray free-electron lasers (XFELs) offer a new avenue to the structural probing of complex materials, including biomolecules. Delivery of precious sample to the XFEL beam is a key consideration, as the sample of interest must be serially replaced after each destructive pulse. The fixed-target approach to sample delivery involves depositing samples on a thin-film support and subsequent serial introduction via a translating stage. Some classes of biological materials, including two-dimensional protein crystals, must be introduced on fixed-target supports, as they require a flat surface to prevent sample wrinkling. A series of wafer and transmission electron microscopy (TEM)-style grid supports constructed of low- Z plastic have been custom-designed and produced. Aluminium TEM grid holders were engineered, capable of delivering up to 20 different conventional or plastic TEM grids using fixed-target stages available at the Linac Coherent Light Source (LCLS). As proof-of-principle, X-ray diffraction has been demonstrated from two-dimensional crystals of bacteriorhodopsin and three-dimensional crystals of anthrax toxin protective antigen mounted on these supports at the LCLS. In conclusion, the benefits and limitations of these low- Z fixed-target supports are discussed; it is the authors' belief that they represent a viable and efficient alternative to previously reported fixed-target supports for conducting diffraction studies with XFELs.

59 BASIC BIOLOGICAL SCIENCES↗

An InGaAs detector based radiation thermometer and fixed-point blackbodies for temperature scale realization at NIM

In this paper, we describe an InGaAs detector based radiation thermometer (IRT) and new design of fixed-point blackbodies, including Sn, Zn, Al and Cu, for the establishment of a temperature scale from 200 °C to 1085 °C at the National Institute of Metrology of China. The construction and calibration of the IRT with the four fixed-point blackbodies are described. Characteristics of the IRT, such as the size-of-source effect, the amplifier performance and its stability are determined. The design of the four fixed-points, with 10 mm diameter of aperture and 0.9999 emissivity, is described. The uncertainty of the scale realization is elaborated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tunable Soft X-Ray Oscillators

A concept for a tunable soft x-ray free electron laser (FEL) photon source is presented and studied numerically. The concept is based on echo-enabled harmonic generation (EEHG), wherein two modulator-chicane sections impose high harmonic structure with much greater efficacy as compared to conventional high harmonic FELs that use only one modulator-chicane section. The idea proposed here is to replace the external laser power sources in the EEHG modulators with FEL oscillators, and to combine the bunching of the beam with the production of radiation. Tunability is accomplished by adjusting the magnetic chicanes while the two oscillators remain at a fixed frequency. This scheme eliminates the need to develop coherent sources with the requisite power, pulse length, and stability requirements by exploiting the MHz bunch repetition rates of FEL continuous wave (CW) sources driven by superconducting (SC) linacs. We present time-dependent GINGER simulation results for an EEHG scheme with an oscillator modulator at 43 nm employing 50percent reflective dielectric mirrors and a second modulator employing an external, 215-nm drive laser. Peak output of order 300 MW is obtained at 2.7 nm, corresponding to the 80th harmonic of 215 nm. An alternative single-cavity echo-oscillator scheme based on a 13.4 nm oscillator is investigated with time-independent simulations that a 180-MW peak power at final wavelength of 1.12 nm. Three alternate configurations that use separate bunches to produce the radiation for EEHG microbunching are also presented. Our results show that oscillator-based soft x-ray FELs driven by CWSC linacs are extremely attractive because of their potential to produce tunable radiation at high average power together with excellent longitudinal coherence and narrow spectral bandwidth.

43 PARTICLE ACCELERATORS↗

Device for collecting chemical compounds and related methods

A device for sampling chemical compounds from fixed surfaces and related methods are disclosed. The device may include a vacuum source, a chamber and a sorbent material. The device may utilize vacuum extraction to volatilize the chemical compounds from the fixed surfaces so that they may be sorbed by the sorbent material. The sorbent material may then be analyzed using conventional thermal desorption/gas chromatography/mass spectrometry (TD/GC/MS) instrumentation to determine presence of the chemical compounds. The methods may include detecting release and presence of one or more chemical compounds and determining the efficacy of decontamination. The device may be useful in collection and analysis of a variety of chemical compounds, such as residual chemical warfare agents, chemical attribution signatures and toxic industrial chemicals.

47 OTHER INSTRUMENTATION↗

Devices for collecting chemical compounds

A device for sampling chemical compounds from fixed surfaces and related methods are disclosed. The device may include a vacuum source, a chamber and a sorbent material. The device may utilize vacuum extraction to volatilize the chemical compounds from a fixed surface so that they may be sorbed by the sorbent material. The sorbent material may then be analyzed using conventional thermal desorption/gas chromatography/mass spectrometry (TD/GC/MS) instrumentation to determine presence of the chemical compounds. The methods may include detecting release and presence of one or more chemical compounds and determining the efficacy of decontamination. The device may be useful in collection and analysis of a variety of chemical compounds, such as residual chemical warfare agents, chemical attribution signatures and toxic industrial chemicals.

47 OTHER INSTRUMENTATION↗

Design Characteristics to Eliminate the Need for Parameter Optimization in Nanoflow ESI-MS

The sampling efficiency in electrospray ionization-mass spectrometry (ESI-MS) can be improved by decreasing the liquid flow rate to the nanoflow regime, where it is possible to draw a large fraction of the ESI plume into the mass spectrometer. This mode of operation is typically more difficult than ESI-MS at higher flow rates because it requires careful optimization of a number of parameters to achieve optimal sampling efficiency. In this work, we screened the relative impact on signal intensity and spray stability of factors that included sprayer position, spray electrode protrusion, sprayer tip shape, spray angle relative to the MS inlet, nebulizer gas flow rate, ESI potential, and means for generating the electric field to initiate electrospray. Based on the screening results, we explore the possibility of providing fixed optimal values for many of the key source parameters to eliminate much of the tuning that is required for conventional nanoflow sources. This approach has potential to greatly simplify nanoflow ESI-MS, while providing optimized sensitivity, stability, and robustness, with decreased variability between analyses. .

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Numerical solution of the Stratonovich- and Ito–Euler equations: Application to the stochastic piston problem

We consider a piston with a velocity perturbed by Brownian motion moving into a straight tube filled with a perfect gas at rest. The shock generated ahead of the piston can be located by solving the one-dimensional Euler equations driven by white noise using the Stratonovich or Ito formulations. We approximate the Brownian motion with its spectral truncation and subsequently apply stochastic collocation using either sparse grid or the quasi-Monte Carlo (QMC) method. In particular, we first transform the Euler equations with an unsteady stochastic boundary into stochastic Euler equations over a fixed domain with a time-dependent stochastic source term. We then solve the transformed equations by splitting them up into two parts, i.e., a ‘deterministic part’ and a ‘stochastic part’. Numerical results verify the Stratonovich–Euler and Ito–Euler models against stochastic perturbation results, and demonstrate the efficiency of sparse grid and QMC for small and large random piston motions, respectively. The variance of shock location of the piston grows cubically in the case of white noise in contrast to colored noise reported in [1], where the variance of shock location grows quadratically with time for short times and linearly for longer times.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Commissioning and first results of scanning type EXAFS beamline (BL-09) at INDUS-2 synchrotron source

An Energy Scanning X-ray Absorption Fine Structure spectroscopy beamline has recently been installed and commissioned at BL-09 bending magnet port of INDUS-2 synchrotron source, Indore. The beamline uses an UHV compatible fixed exit double crystal monochromator (DCM) with two Si (111) crystals. Two grazing incidence cylindrical mirrors are also used in this beamline; the pre-mirror is used as a collimating mirror while the post mirror is used for vertical focusing and higher harmonic rejection. In this beamline it is possible to carry out EXAFS measurements both in transmission and fluorescence mode on various types of samples, using Ionization chamber detectors and solid state drift detector respectively. In this paper, results from first experiments of the Energy Scanning EXAFS beamline are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Model for Hybrid Systems for Production Cost Modeling Studies Considering Ancillary Services

This paper introduces a model for simulating hybrid plants participating in energy and ancillary services for bulk power system studies. The model considers a hybrid plant comprised of a renewable energy source, a thermal power unit, a storage unit, fixed power loads, or any combination of these technologies. The model focuses on Production Cost Modeling (PCM) studies under the assumption of centralized dispatch. We present an example case study to illustrate the use of the model in a single-stage production cost model similar to those conducted by planning agencies. We explore the allocation of behind-the-meter ancillary services products and total energy participation to hybrid plant sub-assets and the resulting impacts on the system's ancillary service allocation. The model is implemented and simulated in a unit commitment problem in the RTS test system, which was modified to include a hybrid plant asset.

ancillary services↗

DISARM: Target Electronic Device Informed Mitigation of Software Runtime Side-Channel Vulnerabilities

Program runtime/timing attacks exploit variations in a program’s execution times to extract sensitive information from the program (e.g. encryption keys, sensitive variable data, intellectual property). State-of-the-art solutions to runtime side-channel attacks attempt to balance the execution time of the sensitive code for different control flow paths to eliminate the timing leakage. However, during the mitigation process, most techniques do not consider the underlying hardware/device on which the target program is supposed to run on. This can lead to over-fixing (unnecessary extra operations), under-fixing (not solving the imbalance properly), and even failures. Here, we propose DISARM, a joint hardware-software methodology (unlike any existing solution) for mitigating runtime side-channel vulnerabilities that utilizes timing values from real embedded devices to generate targeted software fixes. We implement DISARM to support C/C++/Java source codes and validate it across 22 standard benchmarks. DISARM outperforms state-of-the-art solutions such as PENDULUM and DifFuzzaR in terms of execution time overhead, code size overhead, and correctness on five different embedded/edge devices.

Timing/runtime side-channel↗

TH-A-18C-09: Ultra-Fast Monte Carlo Simulation for Cone Beam CT Imaging of Brain Trauma

Purpose: Application of cone-beam CT (CBCT) to low-contrast soft tissue imaging, such as in detection of traumatic brain injury, is challenged by high levels of scatter. A fast, accurate scatter correction method based on Monte Carlo (MC) estimation is developed for application in high-quality CBCT imaging of acute brain injury. Methods: The correction involves MC scatter estimation executed on an NVIDIA GTX 780 GPU (MC-GPU), with baseline simulation speed of ~1e7 photons/sec. MC-GPU is accelerated by a novel, GPU-optimized implementation of variance reduction (VR) techniques (forced detection and photon splitting). The number of simulated tracks and projections is reduced for additional speed-up. Residual noise is removed and the missing scatter projections are estimated via kernel smoothing (KS) in projection plane and across gantry angles. The method is assessed using CBCT images of a head phantom presenting a realistic simulation of fresh intracranial hemorrhage (100 kVp, 180 mAs, 720 projections, source-detector distance 700 mm, source-axis distance 480 mm). Results: For a fixed run-time of ~1 sec/projection, GPU-optimized VR reduces the noise in MC-GPU scatter estimates by a factor of 4. For scatter correction, MC-GPU with VR is executed with 4-fold angular downsampling and 1e5 photons/projection, yielding 3.5 minute run-time per scan, and de-noised with optimized KS. Corrected CBCT images demonstrate uniformity improvement of 18 HU and contrast improvement of 26 HU compared to no correction, and a 52% increase in contrast-tonoise ratio in simulated hemorrhage compared to “oracle” constant fraction correction. Conclusion: Acceleration of MC-GPU achieved through GPU-optimized variance reduction and kernel smoothing yields an efficient (<5 min/scan) and accurate scatter correction that does not rely on additional hardware or simplifying assumptions about the scatter distribution. The method is undergoing implementation in a novel CBCT dedicated to brain trauma imaging at the point of care in sports and military applications. Research grant from Carestream Health. JY is an employee of Carestream Health.